147 resultados para Measurement,


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of our study was to present a new headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable to the routine determination of hydrogen sulfide (H(2)S) concentrations in biological and gaseous samples. The primary analytical drawback of the GC/MS methods for H(2)S measurement discussed in the literature was the absence of a specific H(2)S internal standard required to perform quantification. Although a deuterated hydrogen sulfide (D(2)S) standard is currently available, this standard is not often used because this standard is expensive and is only available in the gas phase. As an alternative approach, D(2)S can be generated in situ by reacting deuterated chloride with sodium sulfide; however, this technique can lead to low recovery yield and potential isotopic fractionation. Therefore, N(2)O was chosen for use as an internal standard. This method allows precise measurements of H(2)S concentrations in biological and gaseous samples. Therefore, a full validation using accuracy profile based on the β-expectation tolerance interval is presented. Finally, this method was applied to quantify H(2)S in an actual case of H(2)S fatal intoxication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strong platelet activation results in a redistribution of negatively charged phospholipids from the cytosolic to the outer leaflet of the cellular membrane. Annexin V has a high affinity to negatively charged phospholipids and can be used to identify procoagulant platelets. Formaldehyde fixation can cause factitious Annexin V binding. Our aim was to evaluate a method for fixing platelets avoiding additional Annexin V binding. We induced expression of negatively charged phospholipids on the surface of a fraction of platelets by combined activation with convulxin and thrombin in the presence of Annexin V-fluorescein isothiocyanate and calcium. Aliquots of resting and activated platelets were fixed with a low concentration, calcium-free formaldehyde solution. Both native platelets and fixed platelets were analyzed by flow cytometry immediately and after a 24-h storage at 4°C. We observed that the percentage of Annexin V positive resting platelets ranged from 1.5 to 9.3% for the native samples and from 0.4 to 12.8% for the fixed samples (P=0.706, paired t-test). The amount of Annexin V positive convulxin/thrombin activated platelets varied from 12.9 to 35.4% without fixation and from 15.3 to 36.3% after formalin fixation (P=0.450). After a 24-h storage at 4°C, Annexin V positive platelets significantly increased both in the resting and in the convulxin/thrombin activated samples of native platelets (both P<0.001), while results for formalin fixed platelets did not differ from baseline values (P=0.318 for resting fixed platelets; P=0.673 for activated fixed platelets). We conclude that platelet fixation with a low concentration, calcium-free formaldehyde solution does not alter the proportion of Annexin V positive platelets. This method can be used to investigate properties of procoagulant platelets by multicolor flow-cytometric analysis requiring fixation steps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring the performance is a crucial task for elite sports during both training and competition. Velocity is the key parameter of performance in swimming, but swimming performance evaluation remains immature due to the complexities of measurements in water. The purpose of this study is to use a single inertial measurement unit (IMU) to estimate front crawl velocity. Thirty swimmers, equipped with an IMU on the sacrum, each performed four different velocity trials of 25 m in ascending order. A tethered speedometer was used as the velocity measurement reference. Deployment of biomechanical constraints of front crawl locomotion and change detection framework on acceleration signal paved the way for a drift-free integration of forward acceleration using IMU to estimate the swimmers velocity. A difference of 0.6 ± 5.4 cm · s(-1) on mean cycle velocity and an RMS difference of 11.3 cm · s(-1) in instantaneous velocity estimation were observed between IMU and the reference. The most important contribution of the study is a new practical tool for objective evaluation of swimming performance. A single body-worn IMU provides timely feedback for coaches and sport scientists without any complicated setup or restraining the swimmer's natural technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT. A dual-wavelength digital holographic microscope to measure absolute volume of living cells is proposed. The optical setup allows us to reconstruct two quantitative phase contrast images at two different wavelengths from a single hologram acquisition. When adding the absorbing dye fast green FCF as a dispersive agent to the extracellular medium, cellular thickness can be univocally determined in the full field of view. In addition to the absolute cell volume, the method can be applied to derive important biophysical parameters of living cells including osmotic membrane water permeability coefficient and the integral intracellular refractive index (RI). Further, the RI of transmembrane flux can be determined giving an indication about the nature of transported solutes. The proposed method is applied to cultured human embryonic kidney cells, Chinese hamster ovary cells, human red blood cells, mouse cortical astrocytes, and neurons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed.¦METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy.¦RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months.¦CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paracaspase MALT1 is a Cys-dependent, Arg-specific protease that plays an essential role in the activation and proliferation of lymphocytes during the immune response. Oncogenic activation of MALT1 is associated with the development of specific forms of B-cell lymphomas. Through specific cleavage of its substrates, MALT1 controls various aspects of lymphocyte activation, including the activation of transcriptional pathways, the stabilization of mRNAs, and an increase in cellular adhesion. In lymphocytes, the activity of MALT1 is tightly controlled by its inducible monoubiquitination, which promotes the dimerization of MALT1. Here, we describe both in vitro and in vivo assays that have been developed to assess MALT1 activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: TIDratio indirectly reflects myocardial ischemia and is correlated with cardiacprognosis. We aimed at comparing the influence of three different softwarepackages for the assessment of TID using Rb-82 cardiac PET/CT. Methods: Intotal, data of 30 patients were used based on normal myocardial perfusion(SSS<3 and SRS<3) and stress myocardial blood flow 2mL/min/g)assessed by Rb-82 cardiac PET/CT. After reconstruction using 2D OSEM (2Iterations, 28 subsets), 3-D filtering (Butterworth, order=10, ωc=0.5), data were automatically processed, and then manually processed fordefining identical basal and apical limits on both stress and rest images.TIDratio were determined with Myometrix®, ECToolbox® and QGS®software packages. Comparisons used ANOVA, Student t-tests and Lin concordancetest (ρc). Results: All of the 90 processings were successfullyperformed. TID ratio were not statistically different between software packageswhen data were processed automatically (P=0.2) or manually (P=0.17). There was a slight, butsignificant relative overestimation of TID with automatic processing incomparison to manual processing using ECToolbox® (1.07 ± 0.13 vs 1.0± 0.13, P=0.001)and Myometrix® (1.07 ± 0.15 vs 1.01 ± 0.11, P=0.003) but not using QGS®(1.02 ±0.12 vs 1.05 ± 0.11, P=0.16). The best concordance was achieved between ECToolbox®and Myometrix® manual (ρc=0.67) processing.Conclusion: Using automatic or manual mode TID estimation was not significantlyinfluenced by software type. Using Myometrix® or ECToolbox®TID was significantly different between automatic and manual processing, butnot using QGS®. Software package should be account for when definingTID normal reference limits, as well as when used in multicenter studies. QGS®software seemed to be the most operator-independent software package, whileECToolbox® and Myometrix® produced the closest results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring school efficiency is a challenging task. First, a performance measurement technique has to be selected. Within Data Envelopment Analysis (DEA), one such technique, alternative models have been developed in order to deal with environmental variables. The majority of these models lead to diverging results. Second, the choice of input and output variables to be included in the efficiency analysis is often dictated by data availability. The choice of the variables remains an issue even when data is available. As a result, the choice of technique, model and variables is probably, and ultimately, a political judgement. Multi-criteria decision analysis methods can help the decision makers to select the most suitable model. The number of selection criteria should remain parsimonious and not be oriented towards the results of the models in order to avoid opportunistic behaviour. The selection criteria should also be backed by the literature or by an expert group. Once the most suitable model is identified, the principle of permanence of methods should be applied in order to avoid a change of practices over time. Within DEA, the two-stage model developed by Ray (1991) is the most convincing model which allows for an environmental adjustment. In this model, an efficiency analysis is conducted with DEA followed by an econometric analysis to explain the efficiency scores. An environmental variable of particular interest, tested in this thesis, consists of the fact that operations are held, for certain schools, on multiple sites. Results show that the fact of being located on more than one site has a negative influence on efficiency. A likely way to solve this negative influence would consist of improving the use of ICT in school management and teaching. Planning new schools should also consider the advantages of being located on a unique site, which allows reaching a critical size in terms of pupils and teachers. The fact that underprivileged pupils perform worse than privileged pupils has been public knowledge since Coleman et al. (1966). As a result, underprivileged pupils have a negative influence on school efficiency. This is confirmed by this thesis for the first time in Switzerland. Several countries have developed priority education policies in order to compensate for the negative impact of disadvantaged socioeconomic status on school performance. These policies have failed. As a result, other actions need to be taken. In order to define these actions, one has to identify the social-class differences which explain why disadvantaged children underperform. Childrearing and literary practices, health characteristics, housing stability and economic security influence pupil achievement. Rather than allocating more resources to schools, policymakers should therefore focus on related social policies. For instance, they could define pre-school, family, health, housing and benefits policies in order to improve the conditions for disadvantaged children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Awareness of being monitored can influence participants' habitual physical activity (PA) behavior. This reactivity effect may threaten the validity of PA assessment. Reports on reactivity when measuring the PA of children and adolescents have been inconsistent. The aim of this study was to investigate whether PA outcomes measured by accelerometer devices differ from measurement day to measurement day and whether the day of the week and the day on which measurement started influence these differences. METHODS: Accelerometer data (counts per minute [cpm]) of children and adolescents (n = 2081) pooled from eight studies in Switzerland with at least 10 h of daily valid recording were investigated for effects of measurement day, day of the week, and start day using mixed linear regression. RESULTS: The first measurement day was the most active day. Counts per minute were significantly higher than on the second to the sixth day, but not on the seventh day. Differences in the age-adjusted means between the first and consecutive days ranged from 23 to 45 cpm (3.6%-7.1%). In preschoolchildren, the differences almost reached 10%. The start day significantly influenced PA outcome measures. CONCLUSIONS: Reactivity to accelerometer measurement of PA is likely to be present to an extent of approximately 5% on the first day and may introduce a relevant bias to accelerometer-based studies. In preschoolchildren, the effects are larger than those in elementary and secondary schoolchildren. As the day of the week and the start day significantly influence PA estimates, researchers should plan for at least one familiarization day in school-age children and randomly assign start days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of the blood pressure by the physician remains an essential step in the evaluation of cardiovascular risk. Ambulatory measurement and self-measurement of blood pressure are ways of counteracting the "white coat" effect which is the rise in blood pressure many patients experience in the presence of doctors. Thus, it is possible to define the cardiovascular risk of hypertension and identify the patients with the greatest chance of benefiting from antihypertensive therapy. However, it must be realised that normotensive subjects during their everyday activities and becoming hypertensive in the doctor's surgery, may become hypertensive with time, irrespective of the means used to measure blood pressure. These patients should be followed up regularly even if the decision to treat has been postponed.