94 resultados para MEASURING DEVICES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical implants, like cardiovascular devices, improve the quality of life for countless individuals but may become infected with bacteria like Staphylococcus aureus. Such infections take the form of a biofilm, a structured community of bacterial cells adherent to the surface of a solid substrate. Every biofilm begins with an attractive force or bond between bacterium and substratum. We used atomic force microscopy to probe experimentally forces between a fibronectin-coated surface (i.e., proxy for an implanted cardiac device) and fibronectin-binding receptors on the surface of individual living bacteria from each of 80 clinical isolates of S. aureus. These isolates originated from humans with infected cardiac devices (CDI; n = 26), uninfected cardiac devices (n = 20), and the anterior nares of asymptomatic subjects (n = 34). CDI isolates exhibited a distinct binding-force signature and had specific single amino acid polymorphisms in fibronectin-binding protein A corresponding to E652D, H782Q, and K786N. In silico molecular dynamics simulations demonstrate that residues D652, Q782, and N786 in fibronectin-binding protein A form extra hydrogen bonds with fibronectin, complementing the higher binding force and energy measured by atomic force microscopy for the CDI isolates. This study is significant, because it links pathogenic bacteria biofilms from the length scale of bonds acting across a nanometer-scale space to the clinical presentation of disease at the human dimension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To evaluate the impact of mobile devices and apps on the daily clinical activity of young radiation oncologists. Methods. A web-based questionnaire was sent to 382 young (≤40 years) members of the Italian Association of Radiation Oncology (AIRO). The 14 items investigated the diffusion of mobile devices (smartphones and/or tablets), their impact on daily clinical activity, and possible differences perceived by the participants over time. Results. A total of 158 questionnaires were available for statistical evaluation (response rate 41%). Up to 75% of respondents declared they used an electronic device during their clinical activity. Conversely, 82% considered the impact of smartphones/tables on daily practice low to moderate. Daily device use increased significantly from 2009 to 2012, with high daily use rates rising from 5% to 39.9%. Fulfillment of professional needs was declared by less than 42% of respondents and compliance with app indications by 32%. Almost all physicians desired in 2012 a comprehensive website concerning a variety of apps covering radiation oncologists' needs. Conclusions. Mobile devices are widely used by young Italian radiation oncologists in their daily clinical practice, while the indications so obtained are not always followed. Nevertheless, it would be important to verify the consistency of information found within apps, in order to avoid potential errors that might be detrimental to patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Profiling microRNA (miRNA) expression is of widespread interest given the critical role of miRNAs in many cellular functions. Profiling can be achieved via hybridization-based (microarrays), sequencing-based, or amplification-based (quantitative reverse transcription-PCR, qPCR) technologies. Among these, microarrays face the significant challenge of accurately distinguishing between mature and immature miRNA forms, and different vendors have developed different methods to meet this challenge. Here we measure differential miRNA expression using the Affymetrix, Agilent, and Illumina microarray platforms, as well as qPCR (Applied Biosystems) and ultra high-throughput sequencing (Illumina). We show that the differential expression measurements are more divergent when the three types of microarrays are compared than when the Agilent microarray, qPCR, and sequencing technology measurements are compared, which exhibit a good overall concordance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: General practitioners play a central role in taking deprivation into consideration when caring for patients in primary care. Validated questions to identify deprivation in primary-care practices are still lacking. For both clinical and research purposes, this study therefore aims to develop and validate a standardized instrument measuring both material and social deprivation at an individual level. Methods: The Deprivation in Primary Care Questionnaire (DiPCare-Q) was developed using qualitative and quantitative approaches between 2008 and 2011. A systematic review identified 199 questions related to deprivation. Using judgmental item quality, these were reduced to 38 questions. Two focus groups (primary-care physicians, and primary-care researchers), structured interviews (10 laymen), and think aloud interviews (eight cleaning staff) assured face validity. Item response theory analysis was then used to derive the DiPCare-Q index using data obtained from a random sample of 200 patients who were to complete the questionnaire a second time over the phone. For construct and criterion validity, the final 16 questions were administered to a random sample of 1,898 patients attending one of 47 different private primary-care practices in western Switzerland (validation set) along with questions on subjective social status (subjective SES ladder), education, source of income, welfare status, and subjective poverty. Results: Deprivation was defined in three distinct dimensions (table); material deprivation (eight items), social deprivation (five items) and health deprivation (three items). Item consistency was high in both the derivation (KR20 = 0.827) and the validation set (KR20 = 0.778). The DiPCare-Q index was reliable (ICC = 0.847). For construct validity, we showed the DiPCare-Q index to be correlated to patients' estimation of their position on the subjective SES ladder (rs = 0.539). This position was correlated to both material and social deprivation independently suggesting two separate mechanisms enhancing the feeling of deprivation. Conclusion: The DiPCare-Q is a rapid, reliable and validated instrument useful for measuring both material and social deprivation in primary care. Questions from the DiPCare-Q are easy to use when investigating patients' social history and could improve clinicians' ability to detect underlying social distress related to deprivation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility of intravoxel incoherent motion (IVIM) perfusion measurements in the brain with currently available imaging systems. MATERIALS AND METHODS: We acquired high in-plane resolution (1.2 × 1.2 mm(2) ) diffusion-weighted images with 16 different values of b ranging from 0 to 900 s/mm(2) , in three orthogonal directions, on 3T systems with a 32-multichannel receiver head coil. IVIM perfusion maps were extracted by fitting a double exponential model of signal amplitude decay. Regions of interest were drawn in pathological and control regions, where IVIM perfusion parameters were compared to the corresponding dynamic susceptibility contrast (DSC) parameters. RESULTS: Hyperperfusion was found in the nonnecrotic or cystic part of two histologically proven glioblastoma multiforme and in two histologically proven glioma WHO grade III, as well as in a brain metastasis of lung adenocarcinoma, in a large meningioma, and in a case of ictal hyperperfusion. A monoexponential decay was found in a territory of acute ischemia, as well as in the necrotic part of a glioblastoma. The IVIM perfusion fraction f correlated well with DSC CBV. CONCLUSION: Our initial report suggests that high-resolution brain perfusion imaging is feasible with IVIM in the current clinical setting. J. Magn. Reson. Imaging 2014;39:624-632. © 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plants forming a rosette during their juvenile growth phase, such as Arabidopsis thaliana (L.) Heynh., are able to adjust the size, position and orientation of their leaves. These growth responses are under the control of the plants circadian clock and follow a characteristic diurnal rhythm. For instance, increased leaf elongation and hyponasty - defined here as the increase in leaf elevation angle - can be observed when plants are shaded. Shading can either be caused by a decrease in the fluence rate of photosynthetically active radiation (direct shade) or a decrease in the fluence rate of red compared with far-red radiation (neighbour detection). In this paper we report on a phenotyping approach based on laser scanning to measure the diurnal pattern of leaf hyponasty and increase in rosette size. In short days, leaves showed constitutively increased leaf elevation angles compared with long days, but the overall diurnal pattern and the magnitude of up and downward leaf movement was independent of daylength. Shade treatment led to elevated leaf angles during the first day of application, but did not affect the magnitude of up and downward leaf movement in the following day. Using our phenotyping device, individual plants can be non-invasively monitored during several days under different light conditions. Hence, it represents a proper tool to phenotype light- and circadian clock-mediated growth responses in order to better understand the underlying regulatory genetic network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to develop a computerized method to screen for potentially avoidable hospital readmissions using routinely collected data and a prediction model to adjust rates for case mix. We studied hospital information system data of a random sample of 3,474 inpatients discharged alive in 1997 from a university hospital and medical records of those (1,115) readmitted within 1 year. The gold standard was set on the basis of the hospital data and medical records: all readmissions were classified as foreseen readmissions, unforeseen readmissions for a new affection, or unforeseen readmissions for a previously known affection. The latter category was submitted to a systematic medical record review to identify the main cause of readmission. Potentially avoidable readmissions were defined as a subgroup of unforeseen readmissions for a previously known affection occurring within an appropriate interval, set to maximize the chance of detecting avoidable readmissions. The computerized screening algorithm was strictly based on routine statistics: diagnosis and procedures coding and admission mode. The prediction was based on a Poisson regression model. There were 454 (13.1%) unforeseen readmissions for a previously known affection within 1 year. Fifty-nine readmissions (1.7%) were judged avoidable, most of them occurring within 1 month, which was the interval used to define potentially avoidable readmissions (n = 174, 5.0%). The intra-sample sensitivity and specificity of the screening algorithm both reached approximately 96%. Higher risk for potentially avoidable readmission was associated with previous hospitalizations, high comorbidity index, and long length of stay; lower risk was associated with surgery and delivery. The model offers satisfactory predictive performance and a good medical plausibility. The proposed measure could be used as an indicator of inpatient care outcome. However, the instrument should be validated using other sets of data from various hospitals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dual-energy X-ray absorptiometry (DXA) is commonly used in the care of patients for diagnostic classification of osteoporosis, low bone mass (osteopenia), or normal bone density; assessment of fracture risk; and monitoring changes in bone density over time. The development of other technologies for the evaluation of skeletal health has been associated with uncertainties regarding their applications in clinical practice. Quantitative ultrasound (QUS), a technology for measuring properties of bone at peripheral skeletal sites, is more portable and less expensive than DXA, without the use of ionizing radiation. The proliferation of QUS devices that are technologically diverse, measuring and reporting variable bone parameters in different ways, examining different skeletal sites, and having differing levels of validating data for association with DXA-measured bone density and fracture risk, has created many challenges in applying QUS for use in clinical practice. The International Society for Clinical Densitometry (ISCD) 2007 Position Development Conference (PDC) addressed clinical applications of QUS for fracture risk assessment, diagnosis of osteoporosis, treatment initiation, monitoring of treatment, and quality assurance/quality control. The ISCD Official Positions on QUS resulting from this PDC, the rationale for their establishment, and recommendations for further study are presented here.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les systèmes d'assistance ventriculaire sont apparus durant la dernière décade comme une approche thérapeutique efficace du traitement de l'insuffisance cardiaque terminale, en particulier dans le contexte de manque de donneurs d'organes. Néanmoins, et ceci malgré les progrès techniques majeurs, les taux de complications restent élevés et sont en partie liés à la configuration géométrique, en particulier le site d'implantation de la cannule de sortie à l'aorte thoracique. Bien que l'anastomose à l'aorte descendante permette une chirurgie moins invasive, les bénéfices de cette technique sont toujours controversés, comparée à la méthode standard de l'aorte ascendante, en raison du risque thrombo-embolique possiblement augmenté et des modifications hémodynamiques induites au niveau de l'arc aortique. Dans ce travail, nous comparons in silico en terme de débit et pression les deux possibilités anastomotiques. Nous développons un réseau de modèles mathématiques unidimensionnels, et l'appliquons à diverses situations cliniques, pour différents stades d'insuffisance cardiaque et de vitesses de rotation de la machine. Les données initiales sont obtenues grâce à un modèle OD (c'est-à-dire qui dépend uniquement du temps mais pas de l'espace) du système cardiovasculaire comprenant une assistance circulatoire, validé avec des données cliniques. Les simulations réalisées montrent que les deux méthodes sont similaires, en terme de débit et courbes de pression, ceci pour tous les cas cliniques étudiés. Ces résultats numériques soutiennent la possibilité d'utiliser la technique d'anastomose à l'aorte thoracique descendante, permettant une chirurgie moins invasive. Sur un plan plus fondamental, le système cardiovasculaire peut être simulé par le biais de multiples modèles de niveau de complexité différents, au prix d'un coût computationnel toujours plus élevé. Nous évaluons les avantages de modèles géométriques à plusieurs échelles (uni- et tridimensionnelle) avec données provenant de patients, comparés à des modèles simplifiés. Les résultats montrent que ces modèles de dimensions hétérogènes apportent un bénéfice important en terme de ressources de calcul, tout en conservant une précision acceptable. En conclusion, ces résultats encourageant montrent la relevance des études numériques dans le domaine médical, tant sur le plan fondamental et la compréhension des mécanismes physiopathologiques, que sur le plan applicatif et le développement de nouvelles thérapeutiques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to analyze the debris captured in the distal protection filters used during carotid artery stenting (CAS). Background: CAS is an option available to high-risk patients requiring revascularization. Filters are suggested for optimal stroke prevention during CAS. Methods: From May 2005 to June 2007, filters from 59 asymptomatic patients who underwent CAS were collected and sent to a specialized laboratory for light-microscope and histological analysis. Peri- and postprocedural outcomes were assessed during 1-year follow-up. Results: On the basis of biomedical imaging of the filter debris, the captured material could not be identified as embolized particles from the carotid plaque. On histological analysis the debris consisted mainly of red blood cell aggregates and/ or platelets, occasionally accompanied by granulocytes. We found no consistent histological evidence of embolized particles originating from atherosclerotic plaques. Post-procedure, three neurological events were reported: two (3.4%) transient ischemic attacks (TIA) and one (1.7%) ipsilateral minor stroke. Conclusion: The filters used during CAS in asymptomatic patients planned for cardiac surgery often remained empty. These findings may be explained by assuming that asymptomatic patients feature a different atherosclerotic plaque composition or stabilization through antiplatelet medication. Larger, randomized trials are clearly warranted, especially in the asymptomatic population. © 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have started to use media data to measure party positions and issue salience. The aim of this article is to compare and cross-validate this alternative approach with the more commonly used party manifestos, expert judgments and mass surveys. To this purpose, we present two methods to generate indicators of party positions and issue salience from media coverage: the core sentence approach and political claims analysis. Our cross-validation shows that with regard to party positions, indicators derived from the media converge with traditionally used measurements from party manifestos, mass surveys and expert judgments, but that salience indicators measure different underlying constructs. We conclude with a discussion of specific research questions for which media data offer potential advantages over more established methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In spite of numerous applications of carbon nanofibers (CNFs) in a variety of fields, the potential release of airborne CNF during their special application, which could lead to workers or end-users exposure, has not been well investigated. In this study, the potential release of CNF from an organic vapour respirator cartridge was evaluated by carbon analysis and microscopy analysis. The cartridge consisted of an AC (Activated Carbon)/CNF composite adsorbent and different types of particulate filters. The composite adsorbent CNF were prepared by chemical vapour deposition (CVD). Air was passed through the prepared cartridge for 12 hours at 12 l/min and particles were collected on sampling filters suitable for measuring organic and elemental carbon (OC/EC) by carbon analysis based on the NIOSH 5040 method. Breakthrough of CNFs was also checked by scanning and transmission electron microscopy (SEM/TEM). This study found only minimal amounts of released elemental carbon while passing the air through the cartridge. Meanwhile TEM photos showed a few CNF structures for AC/CNF composite adsorbents which were not in the critical range in terms of length, aspect ratio, or number. [Authors]