309 resultados para Inertial Measurement Unit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Half of the patients with end-stage heart failure suffer from persistent atrial fibrillation (AF). Atrial kick (AK) accounts for 10-15% of the ejection fraction. A device restoring AK should significantly improve cardiac output (CO) and possibly delay ventricular assist device (VAD) implantation. This study has been designed to assess the mechanical effects of a motorless pump on the right chambers of the heart in an animal model. METHODS: Atripump is a dome-shaped biometal actuator electrically driven by a pacemaker-like control unit. In eight sheep, the device was sutured onto the right atrium (RA). AF was simulated with rapid atrial pacing. RA ejection fraction (EF) was assessed with intracardiac ultrasound (ICUS) in baseline, AF and assisted-AF status. In two animals, the pump was left in place for 4 weeks and then explanted. Histology examination was carried out. The mean values for single measurement per animal with +/-SD were analysed. RESULTS: The contraction rate of the device was 60 per min. RA EF was 41% in baseline, 7% in AF and 21% in assisted-AF conditions. CO was 7+/-0.5 l min(-1) in baseline, 6.2+/-0.5 l min(-1) in AF and 6.7+/-0.5 l min(-1) in assisted-AF status (p<0.01). Histology of the atrium in the chronic group showed chronic tissue inflammation and no sign of tissue necrosis. CONCLUSIONS: The artificial muscle restores the AK and improves CO. In patients with end-stage cardiac failure and permanent AF, if implanted on both sides, it would improve CO and possibly delay or even avoid complex surgical treatment such as VAD implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on advanced dual-wavelength digital holographic microscopy (DHM) methods, enabling single-acquisition real-time micron-range measurements while maintaining single-wavelength interferometric resolution in the nanometer regime. In top of the unique real-time capability of our technique, it is shown that axial resolution can be further increased compared to single-wavelength operation thanks to the uncorrelated nature of both recorded wavefronts. It is experimentally demonstrated that DHM topographic investigation within 3 decades measurement range can be achieved with our arrangement, opening new applications possibilities for this interferometric technique. ©2008 COPYRIGHT SPIE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The medulla oblongata (MO) contains a high density of glycinergic synapses and a particularly high concentration of glycine. The aims of this study were to measure directly in vivo the neurochemical profile, including glycine, in MO using a spin-echo-based (1)H MRS sequence at TE?=?2.8 ms and to compare it with three other brain regions (cortex, striatum and hippocampus) in the rat. Glycine was quantified in MO at TE?=?2.8 ms with a Cramér-Rao lower bound (CRLB) of approximately 5%. As a result of the relatively low level of glycine in the other three regions, the measurement of glycine was performed at TE?=?20 ms, which provides a favorable J-modulation of overlapping myo-inositol resonance. The other 14 metabolites composing the neurochemical profile were quantified in vivo in MO with CRLBs below 25%. Absolute concentrations of metabolites in MO, such as glutamate, glutamine, ?-aminobutyrate, taurine and glycine, were in the range of previous in vitro quantifications in tissue extracts. Compared with the other regions, MO had a three-fold higher glycine concentration, and was characterised by reduced (p?<?0.001) concentrations of glutamate (-50?±?4%), glutamine (-54?±?3%) and taurine (-78?±?3%). This study suggests that the functional specialisation of distinct brain regions is reflected in the neurochemical profile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leaders must scan the internal and external environment, chart strategic and task objectives, and provide performance feedback. These instrumental leadership (IL) functions go beyond the motivational and quid-pro quo leader behaviors that comprise the full-range-transformational, transactional, and laissez faire-leadership model. In four studies we examined the construct validity of IL. We found evidence for a four-factor IL model that was highly prototypical of good leadership. IL predicted top-level leader emergence controlling for the full-range factors, initiating structure, and consideration. It also explained unique variance in outcomes beyond the full-range factors; the effects of transformational leadership were vastly overstated when IL was omitted from the model. We discuss the importance of a "fuller full-range" leadership theory for theory and practice. We also showcase our methodological contributions regarding corrections for common method variance (i.e., endogeneity) bias using two-stage least squares (2SLS) regression and Monte Carlo split-sample designs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional U-Pb ages on zircon and monazite demonstrate that granites and gabbros intruded during a short time span of 5 Ma between 293 and 288 Ma in several polycyclic basement units of the Western Austroalpine domain. This bimodal activity reflects increasing underplating of an upwelling mantle at the base of a thinning post-Variscan continental crust.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Intravoxel incoherent motion MRI has been proposed as an alternative method to measure brain perfusion. Our aim was to evaluate the utility of intravoxel incoherent motion perfusion parameters (the perfusion fraction, the pseudodiffusion coefficient, and the flow-related parameter) to differentiate high- and low-grade brain gliomas. MATERIALS AND METHODS: The intravoxel incoherent motion perfusion parameters were assessed in 21 brain gliomas (16 high-grade, 5 low-grade). Images were acquired by using a Stejskal-Tanner diffusion pulse sequence, with 16 values of b (0-900 s/mm(2)) in 3 orthogonal directions on 3T systems equipped with 32 multichannel receiver head coils. The intravoxel incoherent motion perfusion parameters were derived by fitting the intravoxel incoherent motion biexponential model. Regions of interest were drawn in regions of maximum intravoxel incoherent motion perfusion fraction and contralateral control regions. Statistical significance was assessed by using the Student t test. In addition, regions of interest were drawn around all whole tumors and were evaluated with the help of histograms. RESULTS: In the regions of maximum perfusion fraction, perfusion fraction was significantly higher in the high-grade group (0.127 ± 0.031) than in the low-grade group (0.084 ± 0.016, P < .001) and in the contralateral control region (0.061 ± 0.011, P < .001). No statistically significant difference was observed for the pseudodiffusion coefficient. The perfusion fraction correlated moderately with dynamic susceptibility contrast relative CBV (r = 0.59). The histograms of the perfusion fraction showed a "heavy-tailed" distribution for high-grade but not low-grade gliomas. CONCLUSIONS: The intravoxel incoherent motion perfusion fraction is helpful for differentiating high- from low-grade brain gliomas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tamoxifen (tam) is a widely used endocrine therapy in the treatment of early and advanced stage breast cancer in women and men. It is a pro-drug having weak affinity with the estrogen receptor and needs to be converted to its main metabolite, endoxifen (endox), to have full anticancer activity. Cytochrome 2D6 (CYP2D6) plays a major role in the metabolism of tamoxifen to endoxifen. It is genetically highly polymorphic and its activity influences profoundly the synthesis of endoxifen and potentially the efficacy of tamoxifen treatment. Genotyping is currently the most widely used approach in studies and also in clinical practice to categorize patients as poor- (PM), intermediate- (IM), extensive- (EM) and ultra rapid-metabolizers (UM). Some clinicians already use genotyping in order to tailor the endocrine therapy of their patients. Owing to the large inter-individual variations in concentrations of the active moitey due to genetic and non-genetic influences renders the predictive value of the test uncertain for an individual patient. A significant number of patients classified as EM or IM by genotyping have indeed relatively low endoxifen levels similar to PMs1. This suggests that genotyping is probably not the opti ma l meth o d f or predi cti ng end oxif en l evels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper describes how to integrate audience measurement and site visibility as the main research approaches in outdoor advertising research in a single concept. Details are portrayed on how GPS is used on a large scale in Switzerland for mobility analysis and audience measurement. Furthermore, the development of a software solution is introduced that allows the integration of all mobility data and poster location information. Finally a model and its results is presented for the calculation of coverage of individual poster campaigns and for the calculation of the number of contacts generated by each billboard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The blood pressure (BP), heart rate (HR), and humoral effects of single intravenous (i.v.) doses of the angiotensin-converting enzyme (ACE) inhibitor captopril was investigated in five normotensive healthy volunteers. Each subject received at 1-week intervals a bolus dose of either captopril (1, 5, and 25 mg) or its vehicle. The study was conducted in a single-blind fashion, and the order of treatment phases was randomized. The different doses of captopril had no acute effect on BP and HR. They induced a dose-dependent decrease in plasma ACE activity and plasma angiotensin II levels. The angiotensin-(1-8) octapeptide was isolated by solid-phase extraction and high-performance liquid chromatography (HPLC) prior to radioimmunoassay (RIA). All three doses of captopril reduced circulating angiotensin II levels within 15 min of drug administration. Only with the 25-mg dose was the angiotensin II concentration below the detection limit at 15 min and still significantly reduced 90 min after drug administration. Simultaneous and progressive decreases in plasma aldosterone levels were observed both with ACE inhibition and during vehicle injection, but the relative fall was more pronounced after captopril administration. No adverse reaction was noticed. These results demonstrate that captopril given parenterally blocks the renin-angiotensin system in a dose-dependent manner. Only with the dose of 25 mg was the inhibition of plasma-converting enzyme activity and the reduction of plasma angiotensin II sustained for at least 1 1/2 h.