201 resultados para Image texture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

White-light cystoscopy and cytology are the standard tools to diagnose bladder cancer. White-light cystoscopy is excellent to detect macroscopic exophytic tumors, but its sensitivity is poor for flat tumors such as carcinoma in situ. Use of fluorescence cystoscopy during transurethral bladder resection improve tumor detection, particulary for carcinoma in situ. Fluorescence cystoscopy reduce residual tumor rate, especially for voluminous and multifocal tumors with consecutive lower recurrence. Fluorescence is now recommended to diagnose and treat bladder cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kinetics of crystal growth and equilibrium domains in eclogite of the Sesia Zone, Western Alps Darbellay Bastien Institut de Minéralogie et Géochimie Résumé grand public Comme toute matière, la roche est sensible à son environnement et cherche à s'adapter pour acquérir un état stable (état d'équilibre). Les changements des conditions physiques (température et pression) vont ainsi impliquer des modifications dans la roche. Le métamorphisme est l'étude de ces changements. Les minéraux qui constituent la roche peuvent modifier, leur structure, leur chimie ou être remplacer par d'autres minéraux plus stables. Il est ainsi crucial de déterminer les processus responsables et limitant de la croissance minérale. Trois processus permettent la croissance ; (1) la dissolution des éléments du réactant, (2) le transport de ces éléments vers le site de croissance, (3) l'incorporation de ces éléments dans la nouvelle structure. Cette thèse se focalise sur les structures des minéraux de haute pression (forme, zonation chimique, structure interne) pour essayer de déterminer les facteurs importants à l'origine de leur état final. Les zones d'étude se situent dans la zone de Sésia. La première partie traite de la problématique liée à l'incorporation d'un élément dans une structure minérale. A l'image de la croissance humaine, les irrégularités minéralogiques permettent de mettre en lumière un dysfonctionnement de la croissance due à un excès ou à une carence d'un élément. Bien dosé, cet élément est cependant essentiel à la croissance. Les zoisites (épidotes) des métabasites de la région de Cima di Bonze montrent une zonation chimique en sablier. Dans cette zonation la teneur en fer excède la capacité maximum que peut contenir la structure orthorhombique de la zoisite. Des défauts de structure permettent l'accommodation de cet excès. La zoisite peut ainsi adapter sa structure pour permettre l'incorporation d'une relativement grande quantité de fer. Les études précédentes montraient, pour des conditions similaires, la formation de deux épidotes distinctes. La deuxième partie se penche sur la compétition entre le minéral qui fait sa croissance et les minéraux (réactants) qui l'entourent. Les métapélites de la région du Monte Mucrone contiennent des grenats atollaires. Des études détaillées de la texture et de la zonation chimique du grenat ainsi qu'une modélisation thermodynamique ont permis de mieux cerner les facteurs importants responsables de la forme atollaire. Cette structure est obtenue par un changement du comportement de la croissance du grenat le long d'un chemin P-T hercynien. Dans un premier stade, le grenat croît rapidement et consume peu le quartz de la matrice. La croissance se fait ainsi le long des jointures des grains de quartz. Dans un second temps, les changements de conditions PT donnent une croissance lente du grenat et une forte consommation du quartz. Le grenat peut ainsi développer sa forme dodécaédrale classique. La troisième partie s'intéresse aux distances de transport par diffusion d'un élément (ici l'argon) durant la haute pression. Pour ce faire, un profile d'âges 40Ar/39Ar sur biotite a été mesuré depuis un veine de haute pression riche en argon jusque dans son encaissant (granitoïd du Monte Mucrone). Le profile montre une répartition des âges suivant une courbe de diffusion. Le transport se fait sur une longueur de deux centimètre avec l'aide d'un fluide. Il est réduit à une échelle millimétrique quand la phase fluide disparaît. Cette étude montre ainsi les difficultés de transport des éléments durant la haute pression ne permettant pas un rééquilibrage de la roche à grande échelle. Kinetics of crystal growth and equilibrium domains in eclogite of the Sesia Zone, Western Alps Darbellay Bastien Institut de Minéralogie et Géochimie Résumé de thèse Les processus de croissance (diffusion des éléments et les réactions d'interface) et les conditions dans lesquelles les minéraux grandissent (température, pression, fluide, composition chimique de la roche), déterminent la texture ainsi que la zonation des minéraux. Cette thèse se focalise, par le biais de textures peu communes, sur trois différents processus impliqués dans la croissance minérale à haute pression (Zone de Sésia, Alpes de l'Ouest, Italie). L'incorporation d'un élément dans une structure minérale ne peut se faire que dans des sites en accord avec la taille et la charge ionique de l'élément. De plus, la balance de charge doit être maintenue dans le minéral. La régularité de la structure cristalline fixe ainsi une limite maximum de concentration d'un élément donné. Les zoisites provenant des métabasites de la région de Cima di Bonze montrent des zonations en sablier caractérisées par une concentration anormale en fer. La zonation se marque par une différente teinte de biréfringence et par un plus grand angle d'extinction que le reste de la zoisite. Une inter-croissance de clinozoisite à l'intérieur de la structure orthorhombique de la zoisite peut ainsi être suspectée. Les analyses XRD (diffraction des rayons x) ainsi que les analyses Raman ne confirment pas cette suspicion. Seules les analyses TEM (microscope à électrons transmis) montrent des défauts de structure pouvant être interprétés comme des modules de clinozoisite. Ils ne peuvent cependant pas être considérés comme une phase thermodynamique. Un nouveau trou d'immiscibilité entre deux zoisite (X ep= 0.1 and Xep = 0.15) a ainsi pu être établi. Dans les métapélites la région du Monte Mucrone, des grenats fortement zonés montrent une évolution texturale singulière. Ils présentent une forme initiale de `champignon' qui se développe pour former une structure atollaire finale. L'étude conjuguée de la structure 3D et des zonations, ainsi que l'établissement d'un model thermodynamique, indiquent que ces structures proviennent de deux épisodes de croissances : (1) La croissance du grenat durant un chemin prograde hercynien (de 525 °C et 6.2 kbar à 640 °C et 9 kbar) permet la formation des textures atollaires. Elles sont le résultat d'une croissance poecilitique initiale suivie d'une croissance idiomorphique du grenat. (2) La structure est rendue plus complexe par la cristallisation d'un grenat homogène tout autour ainsi qu'à l'intérieur du grenat hercynien durant la haute pression alpine (550 °C and 20 kbar). L'arrivée de l'eau durant la haute pression facilite le transport d'éléments et permet une cristallisation rapide du grenat. La diffusion peut être un facteur limitant de la croissance minéralogique. Elle a aussi une grande importance pour la géochronologie. Une veine de haute pression à l'intérieur du granitoïde du Monte Mucrone a été étudiée dans le but de déterminer la distance de diffusion de l'argon. Le profile d'âges 40Ar/39Ar sur biotites, établi de la veine vers le métagranitoïde, suit une courbe de diffusion. Les âges sont élevés proche de la veine (800 Ma) puis décroissent jusqu'à des âges homogènes (170-150 Ma) à deux centimètres de la veine. La présence de fluide, marqué par de hautes concentrations en chlore, permet une diffusion centimétrique. Cependant, la distance est réduite à une échelle millimétrique quand le fluide est absent. Les très faibles distances de diffusion préservent les âges pré-alpins et impliquent un événement géologique pour les âges de 170-150 Ma. Kinetics of crystal growth and equilibrium domains in eclogite of the Sesia Zone, Western Alps Darbellay Bastien Institut de Minéralogie et Géochimie Thesis abstract Rock textures and zonings are the consequence of growth processes (element diffusion and interface reaction) steered by the environment in which they grew (pressure, differential stress, temperature, fluid and rock composition). The thesis presented here focuses on three different topics, each of it dealing with aspects of mineral growth processes during subduction, in a high-pressure environment. All studies were conducted in the Sesia Zone of the Western European Alps, Italy. The first study addresses the crystallography and geochemistry of element incorporation in zoisite, one of the major hydrous minerals found in subduction zone rocks. Elements can be incorporated into a mineral structure only on crystallographic sites that offer enough space for the ion and the overall charge balance has to be maintained. Element concentrations are hence limited. Incorporation of some elements produces complex zoning, including hourglass like patterns, which are the focus of the first contribution. Zoisites from Cima di Bonze (Sesia Zone) show spectacular hourglass zoning defined by Fe-content variations. The hourglass zones have a distinct birefringence and a different extinction angle than the regular part of the zoisite. We show by detailed XRD (X-ray diffraction) and confocal Raman analyses that the high Fe-zones are nevertheless zoisite, and not clinozoisite as one might expect. High resolution TEM (transmission electron microscopy) analyses show planar defects on (100) that can be interpreted as small-scale clinozoisite modules. However, these clinozoisites cannot be interpreted as a distinctive thermodynamic phase and the entire mineral has to be considered as zoisite. The miscibility gap between two zoisites (Xep = 0.1 and Xep = 0.15) can be then definite at 550 ± 50°C and 14 to 20 Kbar. Strongly zoned garnets in quartz rich metapelite from the Monte Mucrone area (Sesia Zone) show evolution form 3D mushroom to atoll structure. The second contribution presents textural investigations, garnet zoning and thermodynamic modeling that demonstrate that atoll garnets are the result of two distinctive growth events. (1) Garnet atoll structure is already formed during a prograde Hercynian path from 525 °C and 6.2 kbar to 640 °C and 9 kbar. It results in an initial poikilitic growth followed by a final idiomorphic growth event. (2) Alpine HP garnet are homogenous (550 °C and 20 kbar) and grew around and also inside the Hercynian garnet. Lack of prograde Alpine garnet and fast growth of the HP garnet is explained by the absence of water during much of the prograde path. Water saturation was only observed towards the end, close towards the peak metamorphic conditions. Diffusion could be a limiting factor for crystal growth. It has also a great importance in geochronology. HP vein inside the metagranitoide of the Monte Mucrone (~300 Ma) was investigated to determine argon diffusion scales during high-pressure metamorphism. 40Ar/39Ar biotite ages profile from the vein toward the metagranodiorite show a diffusion curve: old ages (800 Ma) located close to the vein decrease until homogenous 170-150 Ma ages are obtained, two centimeter away from the vein. Centimeter-scale diffusion occurs with help of a fluid phase marked by high chlorine concentrations. Argon diffusion is reduced to a millimeter scale when free fluid is absent. Very short diffusion distance permits to preserve pre-Alpine ages. The 170-150 Ma ages are considered to be geologic meaningful, probably resulting from the extensional tectonics linked to opening of the Tethian ocean.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS: The current gold standard in Barrett's esophagus monitoring consists of four-quadrant biopsies every 1-2 cm in accordance with the Seattle protocol. Adding brush cytology processed by digital image cytometry (DICM) may further increase the detection of patients with Barrett's esophagus who are at risk of neoplasia. The aim of the present study was to assess the additional diagnostic value and accuracy of DICM when added to the standard histological analysis in a cross-sectional multicenter study of patients with Barrett's esophagus in Switzerland. METHODS: One hundred sixty-four patients with Barrett's esophagus underwent 239 endoscopies with biopsy and brush cytology. DICM was carried out on 239 cytology specimens. Measures of the test accuracy of DICM (relative risk, sensitivity, specificity, likelihood ratios) were obtained by dichotomizing the histopathology results (high-grade dysplasia or adenocarcinoma vs. all others) and DICM results (aneuploidy/intermediate pattern vs. diploidy). RESULTS: DICM revealed diploidy in 83% of 239 endoscopies, an intermediate pattern in 8.8%, and aneuploidy in 8.4%. An intermediate DICM result carried a relative risk (RR) of 12 and aneuploidy a RR of 27 for high-grade dysplasia/adenocarcinoma. Adding DICM to the standard biopsy protocol, a pathological cytometry result (aneuploid or intermediate) was found in 25 of 239 endoscopies (11%; 18 patients) with low-risk histology (no high-grade dysplasia or adenocarcinoma). During follow-up of 14 of these 18 patients, histological deterioration was seen in 3 (21%). CONCLUSION: DICM from brush cytology may add important information to a standard biopsy protocol by identifying a subgroup of BE-patients with high-risk cellular abnormalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of bone mineral density (BMD) for fracture discrimination may be improved by considering bone microarchitecture. Texture parameters such as trabecular bone score (TBS) or mean Hurst parameter (H) could help to find women who are at high risk of fracture in the non-osteoporotic group. The purpose of this study was to combine BMD and microarchitectural texture parameters (spine TBS and calcaneus H) for the detection of osteoporotic fractures. Two hundred and fifty five women had a lumbar spine (LS), total hip (TH), and femoral neck (FN) DXA. Additionally, texture analyses were performed with TBS on spine DXA and with H on calcaneus radiographs. Seventy-nine women had prevalent fragility fractures. The association with fracture was evaluated by multivariate logistic regressions. The diagnostic value of each parameter alone and together was evaluated by odds ratios (OR). The area under curve (AUC) of the receiver operating characteristics (ROC) were assessed in models including BMD, H, and TBS. Women were also classified above and under the lowest tertile of H or TBS according to their BMD status. Women with prevalent fracture were older and had lower TBS, H, LS-BMD, and TH-BMD than women without fracture. Age-adjusted ORs were 1.66, 1.70, and 1.93 for LS, FN, and TH-BMD, respectively. Both TBS and H remained significantly associated with fracture after adjustment for age and TH-BMD: OR 2.07 [1.43; 3.05] and 1.47 [1.04; 2.11], respectively. The addition of texture parameters in the multivariate models didn't show a significant improvement of the ROC-AUC. However, women with normal or osteopenic BMD in the lowest range of TBS or H had significantly more fractures than women above the TBS or the H threshold. We have shown the potential interest of texture parameters such as TBS and H in addition to BMD to discriminate patients with or without osteoporotic fractures. However, their clinical added values should be evaluated relative to other risk factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a novel approach for the analysis of illicit tablets based on their visual characteristics. In particular, the paper concentrates on the problem of ecstasy pill seizure profiling and monitoring. The presented method extracts the visual information from pill images and builds a representation of it, i.e. it builds a pill profile based on the pill visual appearance. Different visual features are used to build different image similarity measures, which are the basis for a pill monitoring strategy based on both discriminative and clustering models. The discriminative model permits to infer whether two pills come from the same seizure, while the clustering models groups of pills that share similar visual characteristics. The resulting clustering structure allows to perform a visual identification of the relationships between different seizures. The proposed approach was evaluated using a data set of 621 Ecstasy pill pictures. The results demonstrate that this is a feasible and cost effective method for performing pill profiling and monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies at high magnetic fields using the phase of gradient-echo MR images have shown the ability to unveil cortical substructure in the human brain. To investigate the contrast mechanisms in phase imaging, this study extends, for the first time, phase imaging to the rodent brain. Using a 14.1 T horizontal bore animal MRI scanner for in vivo micro-imaging, images with an in-plane resolution of 33 microm were acquired. Phase images revealed, often more clearly than the corresponding magnitude images, hippocampal fields, cortical layers (e.g. layer 4), cerebellar layers (molecular and granule cell layers) and small white matter structures present in the striatum and septal nucleus. The contrast of the phase images depended in part on the orientation of anatomical structures relative to the magnetic field, consistent with bulk susceptibility variations between tissues. This was found not only for vessels, but also for white matter structures, such as the anterior commissure, and cortical layers in the cerebellum. Such susceptibility changes could result from variable blood volume. However, when the deoxyhemoglobin content was reduced by increasing cerebral blood flow (CBF) with a carbogen breathing challenge, contrast between white and gray matter and cortical layers was not affected, suggesting that tissue cerebral blood volume (and therefore deoxyhemoglobin) is not a major source of the tissue phase contrast. We conclude that phase variations in gradient-echo images are likely due to susceptibility shifts of non-vascular origin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography. MATERIALS AND METHODS: Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were performed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software. RESULTS: Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 kV; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 kV; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 kV; 240 mA; mean, 25 sections) was 2.4 mSv. CONCLUSION: CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. OBJECTIVE: To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. MATERIALS AND METHODS: Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. RESULTS: The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. CONCLUSION: Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The trabecular bone score (TBS) is a gray-level textural metric that can be extracted from the two-dimensional lumbar spine dual-energy X-ray absorptiometry (DXA) image. TBS is related to bone microarchitecture and provides skeletal information that is not captured from the standard bone mineral density (BMD) measurement. Based on experimental variograms of the projected DXA image, TBS has the potential to discern differences between DXA scans that show similar BMD measurements. An elevated TBS value correlates with better skeletal microstructure; a low TBS value correlates with weaker skeletal microstructure. Lumbar spine TBS has been evaluated in cross-sectional and longitudinal studies. The following conclusions are based upon publications reviewed in this article: 1) TBS gives lower values in postmenopausal women and in men with previous fragility fractures than their nonfractured counterparts; 2) TBS is complementary to data available by lumbar spine DXA measurements; 3) TBS results are lower in women who have sustained a fragility fracture but in whom DXA does not indicate osteoporosis or even osteopenia; 4) TBS predicts fracture risk as well as lumbar spine BMD measurements in postmenopausal women; 5) efficacious therapies for osteoporosis differ in the extent to which they influence the TBS; 6) TBS is associated with fracture risk in individuals with conditions related to reduced bone mass or bone quality. Based on these data, lumbar spine TBS holds promise as an emerging technology that could well become a valuable clinical tool in the diagnosis of osteoporosis and in fracture risk assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Type 2 diabetes is associated with increased fracture risk but paradoxically greater bone mineral density (BMD). Trabecular bone score (TBS) is derived from the texture of the spine dual x-ray absorptiometry (DXA) image and is related to bone microarchitecture and fracture risk, providing information independent of BMD. OBJECTIVE: This study evaluated the ability of lumbar spine TBS to account for increased fracture risk in diabetes. DESIGN AND SETTING: We performed a retrospective cohort study using BMD results from a large clinical registry for the province of Manitoba, Canada. Patients: We included 29,407 women 50 years old and older with baseline DXA examinations, among whom 2356 had diagnosed diabetes. MAIN OUTCOME MEASURES: Lumbar spine TBS was derived for each spine DXA examination blinded to clinical parameters and outcomes. Health service records were assessed for incident nontraumatic major osteoporotic fractures (mean follow-up 4.7 years). RESULTS: Diabetes was associated with higher BMD at all sites but lower lumbar spine TBS in unadjusted and adjusted models (all P < .001). The adjusted odds ratio (aOR) for a measurement in the lowest vs the highest tertile was less than 1 for BMD (all P < .001) but was increased for lumbar spine TBS [aOR 2.61, 95% confidence interval (CI) 2.30-2.97]. Major osteoporotic fractures were identified in 175 women (7.4%) with and 1493 (5.5%) without diabetes (P < .001). Lumbar spine TBS was a BMD-independent predictor of fracture and predicted fractures in those with diabetes (adjusted hazard ratio 1.27, 95% CI 1.10-1.46) and without diabetes (hazard ratio 1.31, 95% CI 1.24-1.38). The effect of diabetes on fracture was reduced when lumbar spine TBS was added to a prediction model but was paradoxically increased from adding BMD measurements. CONCLUSIONS: Lumbar spine TBS predicts osteoporotic fractures in those with diabetes, and captures a larger portion of the diabetes-associated fracture risk than BMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.