107 resultados para Hospitals -- Repair an reconstruction -- Spain -- Gandia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The objective of this study was to investigate the additional burdens in terms of pain, prolongation of surgery and morbidity which is added to elective caesarean section if umbilical hernia suture repair is performed simultaneously. Secondly, patient's satisfaction and hernia recurrence rate were assessed. METHODS: Consecutive women with symptomatic umbilical hernia undergoing internal or external suture repair during elective caesarean were included in this retrospective cohort-control study. Data on post-operative pain, duration of surgery and morbidity of a combined procedure were collected. These patients were matched 1:10 to women undergoing caesarean section only. Additionally, two subgroups were assessed separately: external and internal suture hernia repair. These subgroups were compared for patient's satisfaction, cosmesis, body image and recurrence rate. RESULTS: Fourteen patients with a mean age of 37 years were analysed. Internal suture repair (n = 7) prolonged caesarean section by 20 min (p = 0.001) and external suture repair (n = 7) by 34 min (p < 0.0001). Suture repair did not increase morphine use (0.38 ± 0.2 vs. 0.4 ± 02 mg/kg body weight), had no procedure-related morbidity and prolonged hospitalization by 0.5 days (p = 0.01). At a median follow-up of 37 (5-125) months, two recurrences in each surgical technique, internal and external suture repair, occurred (28 %). Body image and cosmesis score showed a higher level of functioning in internal suture repair (p = 0.02; p = 0.04). DISCUSSION: Despite a high recurrence rate, internal suture repair of a symptomatic umbilical hernia during elective caesarean section should be offered to women if requested. No additional morbidity or scar is added to caesarean section. Internal repair is faster, and cosmetic results are better, additional skin or fascia dissection is avoided, and it seems to be as effective as an external approach. Yet, women must be informed on the high recurrence rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although active personal dosemeters (APDs) are not used quite often in hospital environments, the possibility to assess the dose and/or dose rate in real time is particularly interesting in interventional radiology and cardiology (IR/IC) since operators can receive relatively high doses while standing close to the primary radiation field.A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. This paper reports on tests performed with APDs on phantoms using an X-ray facility in a hospital environment and APDs worn by interventionalists during routine practice in different European hospitals.The behaviour of the APDs is more satisfactory in hospitals than in laboratories with respect to the influence of the tube peak high voltage and pulse width, because the APDs are tested in scattered fields with dose equivalent rates generally lower than 1 Sv.h(-1).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Résumé Malgré l'apparition de nouvelles techniques chirurgicales dites « sans tension », l'antalgie post-opératoire après cure de hernie inguinale reste un défi pour les anesthésiologistes. Récemment on a suggéré que l'addition de ketamine ou d'un anti-inflammatoire non-stéroïdien (AINS) à un anesthésique local pourrait améliorer et prolonger l'analgésie postopératoire. Le but de cette étude, à laquelle ont participé 36 patients ASA I-II, était d'évaluer si la coadministration de S(+) ketamine ou de ketorolac renforcerait les effets analgésiques de la bupivacaïne après cure ambulatoire de hernie inguinale sous anesthésie générale. L'analgésie a consisté en une infiltration de la plaie associé à un bloc inguinal avec soit 30 ml de bupivacaïne 0,5 % (n=12), soit 27 ml de bupivacaïne 0,5 % + 3 ml de S(+) ketamine (75 mg) (n=12), soit 28 ml de bupivacaïne 0,5 % + 2 ml de ketorolac (60 mg) (n=12). La prise orale d'antalgique en phase postopératoire était standardisée. L'intensité des douleurs a été évaluée au moyen d'une échelle visuelle analogique (EVA), d'un score verbal d'estimation et par algométrie de pression respectivement 2, 4, 6, 24 et 48 heures après l'intervention. Les trois groupes de patients ont présenté le score de douleur évalué par EVA le plus élevé à 24 heures, score significativement différent de ceux mesurés à 6 et 48 heures (P <0.05). A part une sensation de douleurs significativement moindre (score verbal d'estimation) dans le groupe ketorolac à 24 et 48 heures et seulement à 48 heures dans le groupe ketamine, il n'y avait aucune autre différence entre les groupes pour la durée de l'étude (48 heures) en ce qui concerne les scores de douleur, les seuils de douleur à la pression ou la prise postopératoire d'antalgiques « de secours ». En conclusion, l'addition de S(+) ketamine ou de ketorolac, n'améliore que marginalement l'effet analgésique de la bupivacaïne. Ceci peut-être mis en relation avec la technique de cure de hernie « sans tension » induisant un bas niveau de douleur postopératoire. Abstract Objective: The aim of the study was to assess whether coadministration of S(±) ketamine or ketorolac would enhance or prolong local analgesic effect of bupivacaine after inguinal hernia repair. Design: Prospective double-blind randomized study evaluating pain intensity after surgery under general anesthesia. Setting: Outpatient facilities of the University Hospital of Lausanne. Patient: Thirty-six ASA I-II outpatients scheduled for elective day-case inguinal herniorraphy. Intervention: Analgesia strategy consisted of a wound infiltration and an inguinal field block either with 30 mL bupivacairie (0.5%) or with the same volume of a mixture of 27 mL bupivacaine (0.5%) + 3 mL S(+) ketamine (75 mg) or a 28 mL bupivacaine (0.5%) + 2 ML ketorolac (60 mg). Postoperative analgesic regimen was standardized. Outcome Measures: Pain intensity was assessed with a Visual Analog Seale, a verbal rating score, and by pressure algometry 2, 4, 6, 24, and 48 hours after surgery. Results: The 3 groups of patients experienced the highest Visual Analog Scale pain score at 24 hours, which was different from those at 6 and 48 hours (P < 0.05). Apart from a significantly lower pain sensation (verbal rating score) in the ketorolac group at 24 and 48 hours and only at 48 hours with ketamine, there were no other differences in pain scores, pain pressure thresholds, or rescue analgesic consumption between groups throughout the 48-hour study period. Conclusion: The addition of S (+)-ketamine or ketorolac only minimally improves the analgesic effect of bupivacaine. This may be related to the tension-free hernia repair technique associated with low postoperative pain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Treatment of malignant glioma requires a multidisciplinary team. Treatment includes surgery, radiotherapy, and chemotherapy. Recently developed agents have demonstrated activity against recurrent malignant glioma and efficacy if given concurrently with radiotherapy in the upfront setting. Oligodendroglioma with 1p/19q deletions has been recognized as a distinct pathologic entity with particular sensitivity to radiotherapy and chemotherapy. Randomized trials have shown that early neoadjuvant or adjuvant administration of procarbazine, lomustine, and vincristine chemotherapy prolongs disease-free survival; however, it has no impact on overall survival. Temozolomide, a novel alkylating agent, has shown modest activity against recurrent glioma. In combination with radiotherapy in newly diagnosed patients with glioblastoma, temozolomide significantly prolongs survival. Molecular studies have demonstrated that the benefit is mainly observed in patients whose tumors have a methylated methylguanine methyltransferase gene promoter and are thus unable to repair some of the chemotherapy-induced DNA damage. For lower-grade glioma, the use of chemotherapy remains limited to recurrent disease, and first-line administration is the subject of ongoing clinical trials. Irinotecan and agents like gefitinib, erlotinib, and imatinib targeting the epidermal growth factor receptor and platelet-derived growth factor receptor have shown some promise in recurrent malignant glioma. This review summarizes recent developments, focusing on the clinical management of patients in daily neuro-oncology practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Researchers working in the field of global connectivity analysis using diffusion magnetic resonance imaging (MRI) can count on a wide selection of software packages for processing their data, with methods ranging from the reconstruction of the local intra-voxel axonal structure to the estimation of the trajectories of the underlying fibre tracts. However, each package is generally task-specific and uses its own conventions and file formats. In this article we present the Connectome Mapper, a software pipeline aimed at helping researchers through the tedious process of organising, processing and analysing diffusion MRI data to perform global brain connectivity analyses. Our pipeline is written in Python and is freely available as open-source at www.cmtk.org.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Peroxisome proliferator-activated receptors, PPARalpha, PPARbeta/delta and PPARgamma, are fatty acid activated transcription factors that belong to the nuclear hormone receptor family. While they are best known as transcriptional regulators of lipid and glucose metabolism, evidence has also accumulated for their importance in skin homeostasis. The three PPAR isotypes are expressed in rodent and human skin. Various cell culture and in vivo approaches suggest that PPARalpha contributes to fetal skin development, to epidermal barrier maturation and to sebocyte activity. PPARbeta/delta regulates sebocyte differentiation, promotes hair follicle growth and has pro-differentiating effects in keratinocytes in normal and inflammatory conditions. In contrast, the role of PPARgamma appears to be rather minor in keratinocytes, whereas its activity is required for sebaceous gland differentiation. Importantly, PPARalpha and beta/delta are instrumental in skin repair after an injury, each of them playing specific roles. Due to their collective diverse functions in skin biology, PPARs represent a major research target for the understanding and treatment of many skin diseases, such as benign epidermal tumors, papillomas, acne vulgaris and psoriasis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article we introduce JULIDE, a software toolkit developed to perform the 3D reconstruction, intensity normalization, volume standardization by 3D image registration and voxel-wise statistical analysis of autoradiographs of mouse brain sections. This software tool has been developed in the open-source ITK software framework and is freely available under a GPL license. The article presents the complete image processing chain from raw data acquisition to 3D statistical group analysis. Results of the group comparison in the context of a study on spatial learning are shown as an illustration of the data that can be obtained with this tool.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Posttraumatic painful osteoarthritis of the ankle joint after fracture-dislocation often has to be treated with arthrodesis. In the presence of major soft tissue lesions and important bone loss the technique to achieve arthrodesis has to be well chosen in order to prevent hardware failure, infection of bulky implants or non-union. Methods: We present the case of a 53 year-old biker suffering of a fracture-dislocation of the ankle associated with a mayor degloving injury of the heel. After initial immobilization of the lesion by external fixation in Spain the patient was transferred to our hospital for further treatment. The degloving injury of the heel with MRSA infection was initially treated by repeated débridement, changing of the configuration of the Ex Fix and antibiotic therapy with favourable outcome. Because of the bony lesions reconstruction of the ankle-joint was juged not to be an option and arthrodesis was planned. Due to bad soft-tissue situation standard open fixtion with plate and/or screws was not wanted but an option for intramedullary nailing was taken. However the use of a standard retrograde arthrodesis nail comes with two problems: 1) Risk of infection of the heel-part of the calaneus/nail in an unstable soft tissue situation with protruding nail. And 2) talo-calcaneal arthrodesis of an initially healthy subtalar joint. Given the situation of an unstable plantar/heel flap it was decided to perform anklearthrodesis by means of an anterograde nail with static fixation in the talus and in the proximal tibia. Results:This operation was performed with minimal opening at the ankle-site in order to remove the remaining cartilage and improve direct bone to bone contact. Arthrodesis was achieved by means of an anterograde T2 Stryker tibial nail.One year after the anterograde nailing the patient walks without pain for up to 4 hours with a heel of good quality and arthrodesis is achieved. Conclusion: Tibiotalar arthrodesis in the presence of mayor soft tissue lesions and bone loss can be successfully achieved with antegrade nailing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of sulfur and strontium isotopes as tracers for the source/s of water contaminants have been applied to the water of the Llobregat River system (NE Spain). Surface water samples from June 1997 were collected from the Llobregat River and its main tributaries and creeks. The chemistry of most stream waters are controlled mainly by the weathering of Tertiary chemical sediments within the drainage basin. The largest variation in delta(34)S values were found in the small creeks with values ranging from -9.9 to 15parts per thousand, whilst in the main river channels values ranged from 6.3 to 12.4parts per thousand. The Sr-87/Sr-86 ratio for dissolved strontium ranged from 0.70795 for a non-polluted site to 0.70882 for a polluted one. Most of the waters with high NO3 and low Ca/Na ratio converge to the same Sr-87/Sr-86 value, pointing to dominant pollutant end member contribution or a mixing of pollutants with an isotopic composition around 0.7083-0.7085. Although the concentration of the natural inputs in the river for sulfate and strontium are high, as a result of the sulfate outcrops within the geology of the basin, their isotopic characteristics suggest that they can be used as a discriminating device in water pollution problems. However to establish the detailed characteristics of the isotopes as geochemical tools, specific high-resolution case studies are necessary in small areas, where the inputs are well known.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thumb hypoplasia treatment requires considering every component of the maldevelopment. Types II and IIIA hypoplasia share common features such as first web space narrowing, hypoplasia or absence of thenar muscles and metacarpophalangeal joint instability. Many surgical techniques to correct the malformation have been described. We report our surgical strategy that includes modifications of the usual technique that we found useful in reducing morbidity while optimizing the results. A diamond-shape kite flap was used to widen the first web space. Its design allowed primary closure of the donor site using a Dufourmentel flap. The ring finger flexor digitorum superficialis was transferred for opposition transfer, and the same tendon was used to stabilize the metacarpophalangeal joint on its ulnar and/or radial side depending on a uniplanar or more global instability. An omega-shaped K-wire was placed between the first and second metacarpals to maintain a wide opening of the first web space without stressing the reconstructed ulnar collateral ligament of the MCP joint. We report a clinical series of 15 patients (18 thumbs) who had this reconstructive program.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Chronic venous insufficiency (CVI) represents a major global health problem with increasing prevalence and morbidity. CVI is due to an incompetence of the venous valves, which causes venous reflux and distal venous hypertension. Several studies have focused on the replacement of diseased venous valves using xeno- and allogenic transplants, so far with moderate success due to immunologic and thromboembolic complications. Autologous cell-derived tissue-engineered venous valves (TEVVs) based on fully biodegradable scaffolds could overcome these limitations by providing non-immunogenic, non-thrombogenic constructs with remodeling and growth potential. Methods: Tri- and bicuspid venous valves (n=27) based on polyglycolic acid-poly-4-hydroxybutyrate composite scaffolds, integrated into self-expandable nitinol stents, were engineered from autologous ovine bone-marrow-derived mesenchymal stem cells (BM-MSCs) and endothelialized. After in vitro conditioning in a (flow) pulse duplicator system, the TEVVs were crimped (n=18) and experimentally delivered (n=7). The effects of crimping on the tissue-engineered constructs were investigated using histology, immunohistochemistry, scanning electron microscopy, grating interferometry (GI), and planar fluorescence reflectance imaging. Results: The generated TEVVs showed layered tissue formation with increasing collagen and glycosaminoglycan levels dependent on the duration of in vitro conditioning. After crimping no effects were found on the MSC level in scanning electron microscopy analysis, GI, histology, and extracellular matrix analysis. However, substantial endothelial cell loss was detected after the crimping procedure, which could be reduced by increasing the static conditioning phase. Conclusions: Autologous living small-diameter TEVVs can be successfully fabricated from ovine BM-MSCs using a (flow) pulse duplicator conditioning approach. These constructs hold the potential to overcome the limitations of currently used non-autologous replacement materials and may open new therapeutic concepts for the treatment of CVI in the future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The usual treatment of blunt aortic injury (BAI) is prompt surgery. Frequently severe injuries to the brain or lungs exclude further surgical treatment. The purpose of this study is to assess the feasibility of placing endovascular stent-grafts. METHODS: From 1992 through 1999, in our primary and referral trauma center, 26 acute BAI, 21 males and 5 females, mean age 40.2+/-16.3 yrs were diagnosed. The last 4 patients underwent prospectively endovascular repair with Talent endograft. Endoprosthesis parameters were measured on three-dimensional spiral CT reconstruction. While waiting for devices, blood pressure was aggressively lowered and aortic lesions were monitored by transesophageal echography. RESULTS: Stent-graft deployment was successful in all 4 patients. There were no complications of endoleak, stent migration, paraplegia or death. Angiographic exclusion was complete in all 4 patients. CT scans at a mean follow-up of 11+/-5 months showed complete healing of the aortic wall in all patients. CONCLUSIONS: For stable acute BAI, endovascular stent-graft repair is feasible and safe, and is an effective therapeutic alternative to open surgery. Because of the normal proximal and distal wall in aortic injuries, endoluminal treatment might be the therapy of choice in the near future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In vivo dosimetry is a way to verify the radiation dose delivered to the patient in measuring the dose generally during the first fraction of the treatment. It is the only dose delivery control based on a measurement performed during the treatment. In today's radiotherapy practice, the dose delivered to the patient is planned using 3D dose calculation algorithms and volumetric images representing the patient. Due to the high accuracy and precision necessary in radiation treatments, national and international organisations like ICRU and AAPM recommend the use of in vivo dosimetry. It is also mandatory in some countries like France. Various in vivo dosimetry methods have been developed during the past years. These methods are point-, line-, plane- or 3D dose controls. A 3D in vivo dosimetry provides the most information about the dose delivered to the patient, with respect to ID and 2D methods. However, to our knowledge, it is generally not routinely applied to patient treatments yet. The aim of this PhD thesis was to determine whether it is possible to reconstruct the 3D delivered dose using transmitted beam measurements in the context of narrow beams. An iterative dose reconstruction method has been described and implemented. The iterative algorithm includes a simple 3D dose calculation algorithm based on the convolution/superposition principle. The methodology was applied to narrow beams produced by a conventional 6 MV linac. The transmitted dose was measured using an array of ion chambers, as to simulate the linear nature of a tomotherapy detector. We showed that the iterative algorithm converges quickly and reconstructs the dose within a good agreement (at least 3% / 3 mm locally), which is inside the 5% recommended by the ICRU. Moreover it was demonstrated on phantom measurements that the proposed method allows us detecting some set-up errors and interfraction geometry modifications. We also have discussed the limitations of the 3D dose reconstruction for dose delivery error detection. Afterwards, stability tests of the tomotherapy MVCT built-in onboard detector was performed in order to evaluate if such a detector is suitable for 3D in-vivo dosimetry. The detector showed stability on short and long terms comparable to other imaging devices as the EPIDs, also used for in vivo dosimetry. Subsequently, a methodology for the dose reconstruction using the tomotherapy MVCT detector is proposed in the context of static irradiations. This manuscript is composed of two articles and a script providing further information related to this work. In the latter, the first chapter introduces the state-of-the-art of in vivo dosimetry and adaptive radiotherapy, and explains why we are interested in performing 3D dose reconstructions. In chapter 2 a dose calculation algorithm implemented for this work is reviewed with a detailed description of the physical parameters needed for calculating 3D absorbed dose distributions. The tomotherapy MVCT detector used for transit measurements and its characteristics are described in chapter 3. Chapter 4 contains a first article entitled '3D dose reconstruction for narrow beams using ion chamber array measurements', which describes the dose reconstruction method and presents tests of the methodology on phantoms irradiated with 6 MV narrow photon beams. Chapter 5 contains a second article 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations. A dose reconstruction process specific to the use of the tomotherapy MVCT detector is presented in chapter 6. A discussion and perspectives of the PhD thesis are presented in chapter 7, followed by a conclusion in chapter 8. The tomotherapy treatment device is described in appendix 1 and an overview of 3D conformai- and intensity modulated radiotherapy is presented in appendix 2. - La dosimétrie in vivo est une technique utilisée pour vérifier la dose délivrée au patient en faisant une mesure, généralement pendant la première séance du traitement. Il s'agit de la seule technique de contrôle de la dose délivrée basée sur une mesure réalisée durant l'irradiation du patient. La dose au patient est calculée au moyen d'algorithmes 3D utilisant des images volumétriques du patient. En raison de la haute précision nécessaire lors des traitements de radiothérapie, des organismes nationaux et internationaux tels que l'ICRU et l'AAPM recommandent l'utilisation de la dosimétrie in vivo, qui est devenue obligatoire dans certains pays dont la France. Diverses méthodes de dosimétrie in vivo existent. Elles peuvent être classées en dosimétrie ponctuelle, planaire ou tridimensionnelle. La dosimétrie 3D est celle qui fournit le plus d'information sur la dose délivrée. Cependant, à notre connaissance, elle n'est généralement pas appliquée dans la routine clinique. Le but de cette recherche était de déterminer s'il est possible de reconstruire la dose 3D délivrée en se basant sur des mesures de la dose transmise, dans le contexte des faisceaux étroits. Une méthode itérative de reconstruction de la dose a été décrite et implémentée. L'algorithme itératif contient un algorithme simple basé sur le principe de convolution/superposition pour le calcul de la dose. La dose transmise a été mesurée à l'aide d'une série de chambres à ionisations alignées afin de simuler la nature linéaire du détecteur de la tomothérapie. Nous avons montré que l'algorithme itératif converge rapidement et qu'il permet de reconstruire la dose délivrée avec une bonne précision (au moins 3 % localement / 3 mm). De plus, nous avons démontré que cette méthode permet de détecter certaines erreurs de positionnement du patient, ainsi que des modifications géométriques qui peuvent subvenir entre les séances de traitement. Nous avons discuté les limites de cette méthode pour la détection de certaines erreurs d'irradiation. Par la suite, des tests de stabilité du détecteur MVCT intégré à la tomothérapie ont été effectués, dans le but de déterminer si ce dernier peut être utilisé pour la dosimétrie in vivo. Ce détecteur a démontré une stabilité à court et à long terme comparable à d'autres détecteurs tels que les EPIDs également utilisés pour l'imagerie et la dosimétrie in vivo. Pour finir, une adaptation de la méthode de reconstruction de la dose a été proposée afin de pouvoir l'implémenter sur une installation de tomothérapie. Ce manuscrit est composé de deux articles et d'un script contenant des informations supplémentaires sur ce travail. Dans ce dernier, le premier chapitre introduit l'état de l'art de la dosimétrie in vivo et de la radiothérapie adaptative, et explique pourquoi nous nous intéressons à la reconstruction 3D de la dose délivrée. Dans le chapitre 2, l'algorithme 3D de calcul de dose implémenté pour ce travail est décrit, ainsi que les paramètres physiques principaux nécessaires pour le calcul de dose. Les caractéristiques du détecteur MVCT de la tomothérapie utilisé pour les mesures de transit sont décrites dans le chapitre 3. Le chapitre 4 contient un premier article intitulé '3D dose reconstruction for narrow beams using ion chamber array measurements', qui décrit la méthode de reconstruction et présente des tests de la méthodologie sur des fantômes irradiés avec des faisceaux étroits. Le chapitre 5 contient un second article intitulé 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations'. Un procédé de reconstruction de la dose spécifique pour l'utilisation du détecteur MVCT de la tomothérapie est présenté au chapitre 6. Une discussion et les perspectives de la thèse de doctorat sont présentées au chapitre 7, suivies par une conclusion au chapitre 8. Le concept de la tomothérapie est exposé dans l'annexe 1. Pour finir, la radiothérapie «informationnelle 3D et la radiothérapie par modulation d'intensité sont présentées dans l'annexe 2.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Injectable drugs are high-risk products and their reconstitution in hospital wards is a potential source of errors. Thus, in order to secure the reconstitution process and thereby improve safety, the pharmacy department of Lausanne University Hospital is focusing on developing ready-to-use forms (CIVAS). These preparations are compounded in controlled clean rooms and are analyzed prior to release. In the intensive care unit, amiodarone 12.5 mg/mL in glucose 5% is one of the high-risk preparations, which has led the pharmacy to develop a ready-to-use solution. To this end, a one-year stability study was initiated, and the preliminary results (after six months) are illustrated here. A stability-indicating HPLC method was developed and validated for monitoring the concentration of amiodarone. Batches were stored at 5 °C and 30 °C, which were analyzed immediately after preparation, after one, two, four and six months of storage. The pH and osmolality values were monitored at the respective time intervals. It was observed that after six months, all the results were within specifications. However, the pH values started to decrease after two months when amiodarone was stored at 30 °C. After six months, a degradation peak appeared on the chromatogram of these solutions, which suggested that amiodarone is more stable at 5 °C. The preliminary results obtained in this study indicated that injectable amiodarone solutions are stable for six months under refrigerated storage conditions. The study is ongoing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reconstruction of important parameters such as femoral offset and torsion is inaccurate, when templating is based on plain x-rays. We evaluate intraoperative reproducibility of pre-operative CT-based 3D-templating in a consecutive series of 50 patients undergoing primary cementless THA through an anterior approach. Pre-operative planning was compared to a postoperative CT scan by image fusion. The implant size was correctly predicted in 100% of the stems, 94% of the cups and 88% of the heads (length). The difference between the planned and the postoperative leg length was 0.3 + 2.3 mm. Values for overall offset, femoral anteversion, cup inclination and anteversion were 1.4 mm ± 3.1, 0.6° ± 3.3°, -0.4° ± 5° and 6.9° ± 11.4°, respectively. This planning allows accurate implant size prediction. Stem position and cup inclination are accurately reproducible.