81 resultados para High specificity


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phenotypic and functional cell properties are usually analyzed at the level of defined cell populations but not single cells. Yet, large differences between individual cells may have important functional consequences. It is likely that T-cell-mediated immunity depends on the polyfunctionality of individual T cells, rather than the sum of functions of responding T-cell subpopulations. We performed highly sensitive single-cell gene expression profiling, allowing the direct ex vivo characterization of individual virus-specific and tumor-specific T cells from healthy donors and melanoma patients. We have previously shown that vaccination with the natural tumor peptide Melan-A-induced T cells with superior effector functions as compared with vaccination with the analog peptide optimized for enhanced HLA-A*0201 binding. Here we found that natural peptide vaccination induced tumor-reactive CD8 T cells with frequent coexpression of both memory/homing-associated genes (CD27, IL7R, EOMES, CXCR3, and CCR5) and effector-related genes (IFNG, KLRD1, PRF1, and GZMB), comparable with protective Epstein-Barr virus-specific and cytomegalovirus-specific T cells. In contrast, memory/homing-associated and effector-associated genes were less frequently coexpressed after vaccination with the analog peptide. Remarkably, these findings reveal a previously unknown level of gene expression diversity among vaccine-specific and virus-specific T cells with the simultaneous coexpression of multiple memory/homing-related and effector-related genes by the same cell. Such broad functional gene expression signatures within antigen-specific T cells may be critical for mounting efficient responses to pathogens or tumors. In summary, direct ex vivo high-resolution molecular characterization of individual T cells provides key insights into the processes shaping the functional properties of tumor-specific and virus-specific T cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ability to determine the location and relative strength of all transcription-factor binding sites in a genome is important both for a comprehensive understanding of gene regulation and for effective promoter engineering in biotechnological applications. Here we present a bioinformatically driven experimental method to accurately define the DNA-binding sequence specificity of transcription factors. A generalized profile was used as a predictive quantitative model for binding sites, and its parameters were estimated from in vitro-selected ligands using standard hidden Markov model training algorithms. Computer simulations showed that several thousand low- to medium-affinity sequences are required to generate a profile of desired accuracy. To produce data on this scale, we applied high-throughput genomics methods to the biochemical problem addressed here. A method combining systematic evolution of ligands by exponential enrichment (SELEX) and serial analysis of gene expression (SAGE) protocols was coupled to an automated quality-controlled sequence extraction procedure based on Phred quality scores. This allowed the sequencing of a database of more than 10,000 potential DNA ligands for the CTF/NFI transcription factor. The resulting binding-site model defines the sequence specificity of this protein with a high degree of accuracy not achieved earlier and thereby makes it possible to identify previously unknown regulatory sequences in genomic DNA. A covariance analysis of the selected sites revealed non-independent base preferences at different nucleotide positions, providing insight into the binding mechanism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Magnetic resonance imaging with preceding tissue tagging is a robust method for assessing cardiac motion of the entire heartbeat cycle with a high degree of accuracy. One limitation of this technique, however, is the low resolution of the obtained displacement map of the labeled points within the myocardium. By a new tagging technique, which is based on the combination of two or more measurements of the same slice but with different grid positions, a highly improved resolution of cardiac motion data can be achieved. In combination with a multi-heart-phase echo-planar imaging sequence, such images with doubled grid frequency can be acquired in two short breath-hold periods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-fidelity 'proofreading' polymerases are often used in library construction for next-generation sequencing projects, in an effort to minimize errors in the resulting sequence data. The increased template fidelity of these polymerases can come at the cost of reduced template specificity, and library preparation methods based on the AFLP technique may be particularly susceptible. Here, we compare AFLP profiles generated with standard Taq and two versions of a high-fidelity polymerase. We find that Taq produces fewer and brighter peaks than high-fidelity polymerase, suggesting that Taq performs better at selectively amplifying templates that exactly match the primer sequences. Because the higher accuracy of proofreading polymerases remains important for sequencing applications, we suggest that it may be more effective to use alternative library preparation methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this work was to evaluate the ability of 80 MHz ultrasonography to differentiate intra-retinal layers and quantitatively assess photoreceptor dystrophy in small animal models. Four groups of 10 RCS rats each (five dystrophic and five controls) were explored at 25, 35, 45 and 55 days post-natal (PN). A series of retina cross-sections were obtained ex vivo from outside intact eyes using an 80 MHz three-dimensional ultrasound backscatter microscope (20-microm-axial resolution). Ultrasound features of normal retina were correlated to those of corresponding histology and thickness measurements of photoreceptor segment and nuclear layers were performed on all groups. To show the ability of 80 MHz ultrasonography to distinguish the retinal degeneration in vivo, one RCS rat was explored at 25 and 55 days post-natal. Ultrasound image of normal retina displayed four distinct layers marked by reflections at neurites/nuclei interfaces and permitted to differentiate the photoreceptor segment and nuclear layers. The backscatter level from the retina was shown to be related to the size, density and organization of the intra-layer structure. Ultrasound thickness measurements highly correlated with histologic measurements. A thinning (p<0.05) of outer nuclear layer (ONL) was detected over time for controls and was thought to be assigned to retina maturation. Retinal degeneration started at PN35 and resulted in a more pronounced ONL thinning (p<0.05) over time. ONL degeneration was accompanied by segment layer thickening (p<0.05) at PN35 and thinning thereafter. These changes may indicate accumulation of outer segment debris at PN35 then progressive destruction. In vivo images of rat intra-retinal structure showed the ability of the method to distinguish the photoreceptor layer changes. Our results indicate that 80 MHz ultrasonography reveals intra-retinal layers and is sensitive to age and degenerative changes of photoreceptors. This technique has great potential to follow-up retinal dystrophy and therapeutic effects in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel approach for the identification of tumor antigen-derived sequences recognized by CD8(+) cytolytic T lymphocytes (CTL) consists in using synthetic combinatorial peptide libraries. Here we have screened a library composed of 3.1 x 10(11) nonapeptides arranged in a positional scanning format, in a cytotoxicity assay, to search the antigen recognized by melanoma-reactive CTL of unknown specificity. The results of this analysis enabled the identification of several optimal peptide ligands, as most of the individual nonapeptides deduced from the primary screening were efficiently recognized by the CTL. The results of the library screening were also analyzed with a mathematical approach based on a model of independent and additive contribution of individual amino acids to antigen recognition. This biometrical data analysis enabled the retrieval, in public databases, of the native antigenic peptide SSX-2(41-49), whose sequence is highly homologous to the ones deduced from the library screening, among the ones with the highest stimulatory score. These results underline the high predictive value of positional scanning synthetic combinatorial peptide library analysis and encourage its use for the identification of CTL ligands.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The binding specificities of 52 well-characterized monoclonal antibodies (Mabs) against carcinoembryonic antigen (CEA) from 12 different research groups were studied by immunohistochemistry and immuno flow cytometry. In addition, the binding constant for the interaction between Mab and CEA was determined by a solution-phase assay. Cryostat sections of colon carcinoma and normal colon, stomach, liver, pancreas, and spleen were studied by immunohistochemistry. Peripheral blood granulocytes, monocytes, and lymphocytes were assayed by immuno flow cytometry. The Mabs used here have previously been classified into five essentially nonoverlapping epitope groups (GOLD 1-5) (Cancer Res., 49: 4852-4858, 1989). Most Mabs cross-reacted with different normal tissues, ranging from highly cross-reactive Mabs (positive reaction with 8 of 9 discriminating tissues) to relatively specific Mabs (positive reaction with 1 of 9 discriminating tissues). Five Mabs (10%) were specific, reacting only with colon carcinoma, normal colon mucosa, and normal gastric foveola. There was a correlation between epitope group and binding specificity. Mabs with a high degree of CEA specificity almost exclusively belonged to epitope groups 1, 2, and 3, while highly cross-reactive Mabs belonged to epitope groups 4 and 5. There was no correlation between antibody specificity and affinity for CEA. Specific Mabs with high as well as low affinity were found.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Nandrolone is an anabolic steroid widely used in several sports. The numerous nandrolone positive cases in the recent years (International Olympic Committee statistics) led to several studies in the antidoping field. Nevertheless, essential questions pertaining to nandrolone endogenous production, the effects of physical exercise on the excretion of nandrolone metabolites, and contamination from nutritional supplements must still be addressed. The purpose of this study was to evaluate the influence of exhaustive exercises on 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) urinary excretion rates after administration of labeled nandrolone. SETTING AND PARTICIPANTS: A total of 34 healthy male Caucasian volunteers from the Institute of Sports Sciences and Physical Education (University of Lausanne) applied to participate in the study. All subjects were free from any physical drug addiction and were instructed strictly to avoid any nutritional supplement or steroid before and during the study. The participants were randomly dispatched in 2 groups in a double-blind way: a placebo group and a group treated with C-labeled nandrolone. MAIN OUTCOME MEASUREMENTS: The urinary concentrations of the 2 main nandrolone metabolites, 19-NA and 19-NE, were measured using gas chromatography coupled with mass spectrometry. In addition, clinical parameters such as creatinine, total protein, and beta2-microglobuline levels were determined using immunologic assays. RESULTS: After an oral ingestion of a 25 mg 3,4-C2-nandrolone dose, followed by a second identical dose 24 hours later, 19-NA and 19-NE could be detected in the urine for a period of 6 days after the initial intake. Despite several interesting observations, the measurements were very scattered and did not appear to be significantly influenced by exercise sessions in the athlete population. CONCLUSIONS: The results of this study suggest that physical exercise cannot be considered as a reliable parameter that systematically affects nandrolone metabolite concentrations in the urine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Atherosclerosis results in a considerable medical and socioeconomic impact on society. We sought to evaluate novel magnetic resonance imaging (MRI) angiography and vessel wall sequences to visualize and quantify different morphologic stages of atherosclerosis in a Watanabe hereditary hyperlipidemic (WHHL) rabbit model. MATERIAL AND METHODS: Aortic 3D steady-state free precession angiography and subrenal aortic 3D black-blood fast spin-echo vessel wall imaging pre- and post-Gadolinium (Gd) was performed in 14 WHHL rabbits (3 normal, 6 high-cholesterol diet, and 5 high-cholesterol diet plus endothelial denudation) on a commercial 1.5 T MR system. Angiographic lumen diameter, vessel wall thickness, signal-/contrast-to-noise analysis, total vessel area, lumen area, and vessel wall area were analyzed semiautomatically. RESULTS: Pre-Gd, both lumen and wall dimensions (total vessel area, lumen area, vessel wall area) of group 2 + 3 were significantly increased when compared with those of group 1 (all P < 0.01). Group 3 animals had significantly thicker vessel walls than groups 1 and 2 (P < 0.01), whereas angiographic lumen diameter was comparable among all groups. Post-Gd, only diseased animals of groups 2 + 3 showed a significant (>100%) signal-to-noise ratio and contrast-to-noise increase. CONCLUSIONS: A combination of novel 3D magnetic resonance angiography and high-resolution 3D vessel wall MRI enabled quantitative characterization of various atherosclerotic stages including positive arterial remodeling and Gd uptake in a WHHL rabbit model using a commercially available 1.5 T MRI system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

D-lactic acid in urine originates mainly from bacterial production in the intestinal tract. Increased D-lactate excretion as observed in patients affected by short bowel syndrome or necrotizing enterocolitis reflects D-lactic overproduction. Therefore, there is a need for a reliable and sensitive method able to detect D-lactic acid even at subclinical elevation levels. A new and highly sensitive method for the simultaneous determination of L- and D-lactic acid by a two-step procedure has been developed. This method is based on the concentration of lactic acid enantiomers from urine by supported liquid extraction followed by high-performance liquid chromatography-tandem mass spectrometry. The separation was achieved by the use of an Astec Chirobiotic? R chiral column under isocratic conditions. The calibration curves were linear over the ranges of 2-400 and 0.5-100 µmol/L respectively for L- and D-lactic acid. The limit of detection of D-lactic acid was 0.125 µmol/L and its limit of quantification was 0.5 µmol/L. The overall accuracy and precision were well within 10% of the nominal values. The developed method is suitable for production of reference values in children and could be applied for accurate routine analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat limited due to fluorescence false-positive sites. Consequently, magnification cystoscopy has been investigated in order to discriminate false from true fluorescence positive findings. Both white-light and fluorescence modes are possible with the magnification cystoscope, allowing observation of the bladder wall with magnification ranging between 30× for standard observation and 650×. The optical zooming setup allows adjusting the magnification continuously in situ. In the high-magnification (HM) regime, the smallest diameter of the field of view is 600 microns and the resolution is 2.5 microns when in contact with the bladder wall. With this cystoscope, we characterized the superficial vascularization of the fluorescing sites in order to discriminate cancerous from noncancerous tissues. This procedure allowed us to establish a classification based on observed vascular patterns. Seventy-two patients subject to Hexvix® fluorescence cystoscopy were included in the study. Comparison of HM cystoscopy classification with histopathology results confirmed 32/33 (97%) cancerous biopsies and rejected 17/20 (85%) noncancerous lesions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We hypothesized that combining clinical risk factors (CRF) with the heel stiffness index (SI) measured via quantitative ultrasound (QUS) would improve the detection of women both at low and high risk for hip fracture. Categorizing women by risk score improved the specificity of detection to 42.4%, versus 33.8% using CRF alone and 38.4% using the SI alone. This combined CRF-SI score could be used wherever and whenever DXA is not readily accessible. INTRODUCTION AND HYPOTHESIS: Several strategies have been proposed to identify women at high risk for osteoporosis-related fractures; we wanted to investigate whether combining clinical risk factors (CRF) and heel QUS parameters could provide a more accurate tool to identify women at both low and high risk for hip fracture than either CRF or QUS alone. METHODS: We pooled two Caucasian cohorts, EPIDOS and SEMOF, into a large database named "EPISEM", in which 12,064 women, 70 to 100 years old, were analyzed. Amongst all the CRF available in EPISEM, we used only the ones which were statistically significant in a Cox multivariate model. Then, we constructed a risk score, by combining the QUS-derived heel stiffness index (SI) and the following seven CRF: patient age, body mass index (BMI), fracture history, fall history, diabetes history, chair-test results, and past estrogen treatment. RESULTS: Using the composite SI-CRF score, 42% of the women who did not report a hip fracture were found to be at low risk at baseline, and 57% of those who subsequently sustained a fracture were at high risk. Using the SI alone, corresponding percentages were 38% and 52%; using CRF alone, 34% and 53%. The number of subjects in the intermediate group was reduced from 5,400 (including 112 hip fractures) and 5,032 (including 111 hip fractures) to 4,549 (including 100 including fractures) for the CRF and QUS alone versus the combination score. CONCLUSIONS: Combining clinical risk factors to heel bone ultrasound appears to correctly identify more women at low risk for hip fracture than either the stiffness index or the CRF alone; it improves the detection of women both at low and high risk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The capabilities of a high-resolution (HR), accurate mass spectrometer (Exactive-MS) operating in full scan MS mode was investigated for the quantitative LC/MS analysis of drugs in patients' plasma samples. A mass resolution of 50,000 (FWHM) at m/z 200 and a mass extracted window of 5 ppm around the theoretical m/z of each analyte were used to construct chromatograms for quantitation. The quantitative performance of the Exactive-MS was compared with that of a triple quadrupole mass spectrometer (TQ-MS), TSQ Quantum Discovery or Quantum Ultra, operating in the conventional selected reaction monitoring (SRM) mode. The study consisted of 17 therapeutic drugs including 8 antifungal agents (anidulafungin, caspofungin, fluconazole, itraconazole, hydroxyitraconazole posaconazole, voriconazole and voriconazole-N-oxide), 4 immunosuppressants (ciclosporine, everolimus, sirolimus and tacrolimus) and 5 protein kinase inhibitors (dasatinib, imatinib, nilotinib, sorafenib and sunitinib). The quantitative results obtained with HR-MS acquisition show comparable detection specificity, assay precision, accuracy, linearity and sensitivity to SRM acquisition. Importantly, HR-MS offers several benefits over TQ-MS technology: absence of SRM optimization, time saving when changing the analysis from one MS to another, more complete information of what is in the samples and easier troubleshooting. Our work demonstrates that U/HPLC coupled to Exactive HR-MS delivers comparable results to TQ-MS in routine quantitative drug analyses. Considering the advantages of HR-MS, these results suggest that, in the near future, there should be a shift in how routine quantitative analyses of small molecules, particularly for therapeutic drugs, are performed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In bottom-up proteomics, rapid and efficient protein digestion is crucial for data reliability. However, sample preparation remains one of the rate-limiting steps in proteomics workflows. In this study, we compared the conventional trypsin digestion procedure with two accelerated digestion protocols based on shorter reaction times and microwave-assisted digestion for the preparation of membrane-enriched protein fractions of the human pathogenic bacterium Staphylococcus aureus. Produced peptides were analyzed by Shotgun IPG-IEF, a methodology relying on separation of peptides by IPG-IEF before the conventional LC-MS/MS steps of shotgun proteomics. Data obtained on two LC-MS/MS platforms showed that accelerated digestion protocols, especially the one relying on microwave irradiation, enhanced the cleavage specificity of trypsin and thus improved the digestion efficiency especially for hydrophobic and membrane proteins. The combination of high-throughput proteomics with accelerated and efficient sample preparation should enhance the practicability of proteomics by reducing the time from sample collection to obtaining the results.