99 resultados para Hand-held devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In May 2010, Switzerland introduced a heterogeneous smoking ban in the hospitality sector. While the law leaves room for exceptions in some cantons, it is comprehensive in others. This longitudinal study uses different measurement methods to examine airborne nicotine levels in hospitality venues and the level of personal exposure of non-smoking hospitality workers before and after implementation of the law. METHODS: Personal exposure to second hand smoke (SHS) was measured by three different methods. We compared a passive sampler called MoNIC (Monitor of NICotine) badge, to salivary cotinine and nicotine concentration as well as questionnaire data. Badges allowed the number of passively smoked cigarettes to be estimated. They were placed at the venues as well as distributed to the participants for personal measurements. To assess personal exposure at work, a time-weighted average of the workplace badge measurements was calculated. RESULTS: Prior to the ban, smoke-exposed hospitality venues yielded a mean badge value of 4.48 (95%-CI: 3.7 to 5.25; n = 214) cigarette equivalents/day. At follow-up, measurements in venues that had implemented a smoking ban significantly declined to an average of 0.31 (0.17 to 0.45; n = 37) (p = 0.001). Personal badge measurements also significantly decreased from an average of 2.18 (1.31-3.05 n = 53) to 0.25 (0.13-0.36; n = 41) (p = 0.001). Spearman rank correlations between badge exposure measures and salivary measures were small to moderate (0.3 at maximum). CONCLUSIONS: Nicotine levels significantly decreased in all types of hospitality venues after implementation of the smoking ban. In-depth analyses demonstrated that a time-weighted average of the workplace badge measurements represented typical personal SHS exposure at work more reliably than personal exposure measures such as salivary cotinine and nicotine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Suction-based wound healing devices with open-pore foam interfaces are widely used to treat complex tissue defects. The impact of changes in physicochemical parameters of the wound interfaces has not been investigated. METHODS: Full-thickness wounds in diabetic mice were treated with occlusive dressing or a suction device with a polyurethane foam interface varying in mean pore size diameter. Wound surface deformation on day 2 was measured on fixed tissues. Histologic cross-sections were analyzed for granulation tissue thickness (hematoxylin and eosin), myofibroblast density (α-smooth muscle actin), blood vessel density (platelet endothelial cell adhesion molecule-1), and cell proliferation (Ki67) on day 7. RESULTS: Polyurethane foam-induced wound surface deformation increased with polyurethane foam pore diameter: 15 percent (small pore size), 60 percent (medium pore size), and 150 percent (large pore size). The extent of wound strain correlated with granulation tissue thickness that increased 1.7-fold in small pore size foam-treated wounds, 2.5-fold in medium pore size foam-treated wounds, and 4.9-fold in large pore size foam-treated wounds (p < 0.05) compared with wounds treated with an occlusive dressing. All polyurethane foams increased the number of myofibroblasts over occlusive dressing, with maximal presence in large pore size foam-treated wounds compared with all other groups (p < 0.05). CONCLUSIONS: The pore size of the interface material of suction devices has a significant impact on the wound healing response. Larger pores increased wound surface strain, tissue growth, and transformation of contractile cells. Modification of the pore size is a powerful approach for meeting biological needs of specific wounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A passive sampling device called Monitor of NICotine or "MoNIC", was constructed and evaluated by IST laboratory for determining nicotine in Second Hand Tobacco Smoke (SHTS) or Environmental Tobacco Smoke (ETS). Vapour nicotine was passively collected on a potassium bisulfate treated glass fibre filter as collection medium. Analysis of collected nicotine on the treated filter by gas chromatography equipped with Thermoionic-Specific Detector (GC-TSD) after liquid-liquid extraction of 1mL of 5N NaOH : 1 mL of n-heptane saturated with NH3 using quinoline as internal standard. Based on nicotine amount of 0.2 mg/cigarette as the reference, the inhaled Cigarette Equivalents (CE) by non-smokers can be calculated. Using the detected CE on the badge for non-smokers, and comparing with amount of nicotine and cotinine level in saliva of both smokers and exposed non-smokers, we can confirm the use of the CE concept for estimating exposure to ETS. The regional CIPRET (Center of information and prevention of the addiction to smoking) of different cantons (Valais (VS), Vaud (VD), Neuchâtel (NE) and Fribourg (FR)) are going to organize a big campaign on the subject of the passive addiction to smoking. This campaign took place in 2007-2008 and has for objective to inform clearly the Swiss population of the dangerousness of the passive smoke. More than 3'900 MoNIC badges were gracefully distributed to Swiss population to perform a self-monitoring of population exposure level to ETS, expressed in term of CE. Non-stimulated saliva was also collected to determine ETS biomarkers nicotine/cotinine levels of participating volunteers. Results of different levels of CE in occupational and non-occupational situations in relation with ETS were presented in this study. This study, unique in Switzerland, has established a base map on the population's exposure to SHTS. It underscored the fact that all the Swiss people involved in this campaign (N=1241) is exposed to passive smoke, from <0.2 cig/d (10.8%), 1-2 to more than 10 cig/d (89.2%). In the area of high exposure (15-38 cig/d), are the most workers in public restaurant, cafe, bar, disco. By monitoring ETS tracer nicotine and its biomarkers, salivary nicotine and cotinine, it is demonstrated that the MoNIC badge can serve as indicator of CE passive smoking. The MoNIC badge, accompanied with content of salivary nicotine/cotinine can serve as a tool of evaluation of the ETS passive smoking and contributes to supply useful data for future epidemiological studies. It is also demonstrated that the salivary nicotine (without stimulation) is a better biomarker of ETS exposure than cotinine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical implants, like cardiovascular devices, improve the quality of life for countless individuals but may become infected with bacteria like Staphylococcus aureus. Such infections take the form of a biofilm, a structured community of bacterial cells adherent to the surface of a solid substrate. Every biofilm begins with an attractive force or bond between bacterium and substratum. We used atomic force microscopy to probe experimentally forces between a fibronectin-coated surface (i.e., proxy for an implanted cardiac device) and fibronectin-binding receptors on the surface of individual living bacteria from each of 80 clinical isolates of S. aureus. These isolates originated from humans with infected cardiac devices (CDI; n = 26), uninfected cardiac devices (n = 20), and the anterior nares of asymptomatic subjects (n = 34). CDI isolates exhibited a distinct binding-force signature and had specific single amino acid polymorphisms in fibronectin-binding protein A corresponding to E652D, H782Q, and K786N. In silico molecular dynamics simulations demonstrate that residues D652, Q782, and N786 in fibronectin-binding protein A form extra hydrogen bonds with fibronectin, complementing the higher binding force and energy measured by atomic force microscopy for the CDI isolates. This study is significant, because it links pathogenic bacteria biofilms from the length scale of bonds acting across a nanometer-scale space to the clinical presentation of disease at the human dimension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Erosive hand osteoarthritis is common and debilitating. Diagnosis is based on the presence of bone erosions which can appear late. Ultrasonography allows earlier diagnosis. The presence of apatite deposits could be of poor prognosis. Non pharmacological treatment includes the explanation of the inflammatory phenomena involved and the use of splints and physical therapy. Drug therapy includes analgesics, NSAIDs and infiltration of a steroid. Chondroitin sulfates have an analgesic and functional effect proven. DMARDs such as hydroxychloroquine and methotrexate have been used successfully. Some patients also benefited from isotope synoviortheses. New therapeutic ways, based on the pathophysiology of the disease, are new under evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To evaluate the impact of mobile devices and apps on the daily clinical activity of young radiation oncologists. Methods. A web-based questionnaire was sent to 382 young (≤40 years) members of the Italian Association of Radiation Oncology (AIRO). The 14 items investigated the diffusion of mobile devices (smartphones and/or tablets), their impact on daily clinical activity, and possible differences perceived by the participants over time. Results. A total of 158 questionnaires were available for statistical evaluation (response rate 41%). Up to 75% of respondents declared they used an electronic device during their clinical activity. Conversely, 82% considered the impact of smartphones/tables on daily practice low to moderate. Daily device use increased significantly from 2009 to 2012, with high daily use rates rising from 5% to 39.9%. Fulfillment of professional needs was declared by less than 42% of respondents and compliance with app indications by 32%. Almost all physicians desired in 2012 a comprehensive website concerning a variety of apps covering radiation oncologists' needs. Conclusions. Mobile devices are widely used by young Italian radiation oncologists in their daily clinical practice, while the indications so obtained are not always followed. Nevertheless, it would be important to verify the consistency of information found within apps, in order to avoid potential errors that might be detrimental to patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY DESIGN: Prospective neurophysiological study. OBJECTIVE: To identify and quantify the neurophysiological effects of interspinous distraction during spine surgery for lumbar spinal stenosis (LSS). SUMMARY OF BACKGROUND DATA: Interspinous devices have been introduced as an alternative treatment of LSS in selected patients aiming at obtaining indirect decompression. Nevertheless, there is no data on the immediate neurophysiological effect of distraction. METHODS: Thirty patients with LSS undergoing decompression (14 at single level, 16 at multiple levels) were enrolled, resulting in a total of 48 levels to be analyzed. Before decompression, calibrated incremental distraction simulating interspinous device implantation of 8, 10, 12, 14, and 16 mm was performed. Intraoperative motor evoked potentials were acquired before any distraction, during distraction at each incremental value and after bilateral decompression. We evaluated relative changes of motor evoked potentials normalized to hand muscles and related them to the number of affected levels, LSS radiological severity based on the A to D grading, lordosis, and disc height. RESULTS: For single-level disease, 8-mm distraction and open decompression yielded similar improvement in motor evoked potentials not only in levels with morphological grades A or B, but also in levels with morphological grades C or D (i.e., severe or extreme stenosis) (P = 0.32). In contrast, distraction superior to 8 mm was less effective (P ≤ 0.05). In multiple-level stenosis, decompression was significantly more effective than any degree of distraction (P < 0.001). No correlation of those results to disc height or lordosis was observed. Using χ trend test to analyze the effect of distraction, a linear trend favoring moderate over severe stenotic morphology was observed (P = 0.0349). CONCLUSION: Interspinous distraction of 8 mm is sufficient to replicate electrophysiological improvements obtained during full decompression even in severe single-level stenosis but not in multilevel disease. Interspinous distraction has therefore an immediately measurable neurophysiological effect. Level of Evidence: 4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyze the atmosphere inside incubators regarding alcoholic solvent such as isopropanol or ethanol which are commonly used in hand disinfecting solutions. Design: Observational. Setting: The third level neonatal unit of the Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland. Patients: Nine neonates with median (range) gestational age of 29 4/7 (25 5/7-39 0/7) weeks and birth weight of 960 (550-3050) grams. All neonates were inside incubators. Interventions: Alcoholic vapors inside incubators were directly and cumulatively measured by photoionisation and gas chromatography respectively after absorption on a charcoal sampling tube. Results: Eleven studies (mean study time: 230 ± 19 minutes) were performed. Highly variable isopropanol/ethanol concentrations profiles were found inside incubators. Peak value for isopropanol was 1982 part per million and for ethanol was 906 part per million. Conclusions: Incubators' inner atmosphere can be highly polluted by alcohol vapors. To reduce them staff should respect long evaporation time between hands disinfection and manipulations inside incubators. The use of an ethanol-based disinfecting solution, because of its short evaporation time, could be favored. As alcohol vapor toxicity for neonate remains largely unknown, further studies could be welcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic hand eczema is a frequent cause of consultation. In Europe and Switzerland, it's one of the main reasons for patients to interrupt their profession. The etiology is pluri-factorial. Atopic patients are more likely predisposed. Pruritus, associated to pain and bleeding, is intense. Psychosocial consequences are huge, making this illness to an important public health problem. Topical treatment and UV-light are the main therapeutical strategy but the results are often disappointing. Recently, alitretinoine (9-cis retinoic acid) became the treatment of second choice with good response, allowing patients to preserve a good quality of life and their job.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interventional paediatric and congenital cardiology is expanding at a rapid pace. Validated techniques (such as aortic or pulmonary valve dilatations and occlusion of persistent ductus arteriosus and atrial septal defects) are improving thanks to the use of smaller introducers and sheaths, low-profile balloons and novel devices. Moreover, catheter-based interventions have emerged as an attractive alternative to surgery in other fields: pulmonary valve replacement, balloon and stent implantation for native and recurrent coarctation, and percutaneous closure of ventricular septal defects. On the other hand, percutaneous interventions in the paediatric population may be limited by patient size or the anatomy of the defect. Hybrid approaches involving both cardiac interventionists and surgeons are being developed to overcome these limitations. Based on a better understanding of cardiac development, fetal cardiac interventions are being attempted in order to alter the history of severe obstructive lesions. Finally, some interventional procedures still carry a low success rate-for example, pulmonary vein stenosis, even with the use of conventional stents. Biodegradable stents and devices are being developed and may find an application in this setting as well as in others. The purpose of this review is to highlight the advances in paediatric interventional cardiology since the beginning of the third millennium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La désinfection des mains avant d'effectuer des soins est un acte indispensable en médecine clinique pour limiter le risque de transmission de germes. Après utilisation des produits désinfectants mis à disposition dans les services de soins, il se dégage une odeur alcoolique forte et désagréable, liée directement aux alcools antimicrobiens des solutions. Une étude a montré qu'une exposition aiguë et brève aux vapeurs d'éthanol et isopropanol chez des enfants prématurés pouvait être mise en relation avec des changements hémodynamiques au niveau de la zone olfactive orbito-frontale [1]. Aucune norme réglementant les concentrations de vapeurs d'éthanol ou isopropanol auxquelles les nouveau-nés peuvent être exposés n'existe. Cette thèse avait pour but d'étudier l'exposition des nouveaux nés soignés dans des incubateurs à des vapeurs d'alcool (éthanol et isopropanol). Elle était composée de 2 parties qui ont été publiées dans 2 articles différents et qui représentent le travail de doctorat [2-3]. La 1ère partie était une étude observationnelle d'une série de cas [2], Des mesures des concentrations des vapeurs d'alcool ont été effectuées auprès de 9 nouveau-nés soignés dans des incubateurs de même modèle au sein de l'unité de néonatologie du Centre Hospitalier Universitaire Vaudois à Lausanne. Sur 4 heures, les concentrations instantanées et moyennes ont été mesurées par deux techniques (photoionisation et respectivement chromatographic après absorption sur charbon actif). Onze analyses ont été effectuées en 2004-2005. Elles ont révélé des taux très variables d'éthanol et d'isopropanol dans les incubateurs (avec des valeurs maximales de 1982 ppm pour l'isopropanol et 906 ppm pour l'éthanol) correspondant aux introduction de mains fraîchement désinfectées dans les isolettes. Les concentrations moyennes variaient entre 9.8 ppm et plus de 61 ppm pour l'éthanol et < 0.01 ppm et 119 ppm pour l'isopropanol. La 2e partie a été réalisée en collaboration avec le PD Dr D. Vernez de l'Institut Universitaire Romand de Santé au Travail [3], Un modèle théorique prédictif des concentrations alcooliques dans des incubateurs pour nouveau-nés a été développé. Des séries de mesures standardisées des variations des concentrations alcooliques dans un incubateur sans patient ont été effectuées en changeant trois variables: 1) le renouvellement de l'air dans l'incubateur en variant le nombre de portes ouvertes, 2) la quantité de solution alcoolique versée sur les mains avant de les introduire dans l'incubateur 3) le temps de séchage des mains après désinfection et avant de les introduire dans l'incubateur. La modélisation a permis de décrire la cinétique des concentrations d'alcool dans les incubateurs et d'évaluer les pistes potentielles pour diminuer les risques d'exposition des nouveau-nés à ces vapeurs dans leurs incubateurs. En conclusion, la 1 ère partie a mis en évidence, pour la première fois, que des nouveau- nés soignés en incubateurs peuvent être exposés à des vapeurs d'alcool. Comme il η y a aucune norme d'exposition pour cette population et que les seules limites d'exposition existantes sont destinées à des travailleurs adultes, aucune conclusion précise ne peut être avancée sur les risques toxicologiques. L'exposition à des vapeurs polluantes d'un nouveau-né à terme ou prématuré, en plein développement neuro-sensoriel, devrait toutefois, à priori, être évitée. La 2ème partie permet de proposer des pistes pratiques pour diminuer les concentrations des vapeurs d'alcool dans les incubateurs: respecter le temps de séchage des mains après leur désinfection et avant de les introduire dans les isolettes et/ou préférer un désinfectant alcoolique à faible temps d'évaporation.