323 resultados para HEART-BEATING DONORS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catopril, an inhibitor of angiotensin converting enzyme, was given orally during cardiac catheterisation to 6 normotensive patients with refractory congestive heart-failure. 60--180 minutes after administration of 25 mg captopril, arterial pressure fell by 25%, cardiac index rose by 38%, and left-ventricular pressure and right-atrial pressure fell by 25% and 40% respectively. Plasma-renin activity rose while plasma noradrenaline and aldosterone fell. These data suggest that, in the short term, captopril can reduce both preload and afterload, and improve cardiac function, in refractory congestive heart-failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loss of T-tubules (TT), sarcolemmal invaginations of cardiomyocytes (CMs), was recently identified as a general heart failure (HF) hallmark. However, whether TT per se or the overall sarcolemma is altered during HF process is still unknown. In this study, we directly examined sarcolemmal surface topography and physical properties using Atomic Force Microscopy (AFM) in living CMs from healthy and failing mice hearts. We confirmed the presence of highly organized crests and hollows along myofilaments in isolated healthy CMs. Sarcolemma topography was tightly correlated with elasticity, with crests stiffer than hollows and related to the presence of few packed subsarcolemmal mitochondria (SSM) as evidenced by electron microscopy. Three days after myocardial infarction (MI), CMs already exhibit an overall sarcolemma disorganization with general loss of crests topography thus becoming smooth and correlating with a decreased elasticity while interfibrillar mitochondria (IFM), myofilaments alignment and TT network were unaltered. End-stage post-ischemic condition (15days post-MI) exacerbates overall sarcolemma disorganization with, in addition to general loss of crest/hollow periodicity, a significant increase of cell surface stiffness. Strikingly, electron microscopy revealed the total depletion of SSM while some IFM heaps could be visualized beneath the membrane. Accordingly, mitochondrial Ca(2+) studies showed a heterogeneous pattern between SSM and IFM in healthy CMs which disappeared in HF. In vitro, formamide-induced sarcolemmal stress on healthy CMs phenocopied post-ischemic kinetics abnormalities and revealed initial SSM death and crest/hollow disorganization followed by IFM later disarray which moved toward the cell surface and structured heaps correlating with TT loss. This study demonstrates that the loss of crest/hollow organization of CM surface in HF occurs early and precedes disruption of the TT network. It also highlights a general stiffness increased of the CM surface most likely related to atypical IFM heaps while SSM died during HF process. Overall, these results indicate that initial sarcolemmal stress leading to SSM death could underlie subsequent TT disarray and HF setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prenatal heart valve interventions aiming at the early and systematic correction of congenital cardiac malformations represent a promising treatment option in maternal-fetal care. However, definite fetal valve replacements require growing implants adaptive to fetal and postnatal development. The presented study investigates the fetal implantation of prenatally engineered living autologous cell-based heart valves. Autologous amniotic fluid cells (AFCs) were isolated from pregnant sheep between 122 and 128 days of gestation via transuterine sonographic sampling. Stented trileaflet heart valves were fabricated from biodegradable PGA-P4HB composite matrices (n = 9) and seeded with AFCs in vitro. Within the same intervention, tissue engineered heart valves (TEHVs) and unseeded controls were implanted orthotopically into the pulmonary position using an in-utero closed-heart hybrid approach. The transapical valve deployments were successful in all animals with acute survival of 77.8% of fetuses. TEHV in-vivo functionality was assessed using echocardiography as well as angiography. Fetuses were harvested up to 1 week after implantation representing a birth-relevant gestational age. TEHVs showed in vivo functionality with intact valvular integrity and absence of thrombus formation. The presented approach may serve as an experimental basis for future human prenatal cardiac interventions using fully biodegradable autologous cell-based living materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The magnitude of coffee-induced thermogenesis and the influence of coffee ingestion on substrate oxidation were investigated in 10 lean and 10 obese women, over two 24-h periods in a respiratory chamber. On one occasion the subjects consumed caffeinated coffee and on the other occasion, decaffeinated coffee. The magnitude of thermogenesis was smaller in obese (4.9 +/- 2.0%) than in lean subjects (7.6 +/- 1.3%). The thermogeneic response to caffeine was prolonged during the night in lean women only. The coffee-induced stimulation of energy expenditure was mediated by a concomitant increase in lipid and carbohydrate oxidation. During the next day, in postabsorptive basal conditions, the thermogenic effect of coffee had vanished, but a significant increase in lipid oxidation was observed in both groups. The magnitude of this effect was, however, blunted in obese women (lipid oxidation increased by 29 and 10% in lean and obese women, respectively). Caffeine increased urinary epinephrine excretion. Whereas urinary caffeine excretion was similar in both groups, obese women excreted more theobromine, theophylline, and paraxanthine than lean women. Despite the high levels of urinary methylxanthine excretion, thermogenesis and lipid oxidation were less stimulated in obese than in lean subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the efficacy of anti-J5 serum in the treatment of severe infectious purpura, 73 children were randomized to receive either anti-J5 (40) or control (33) plasma. Age, blood pressure, and biologic risk factors were similar in both groups. At admission, however, tumor necrosis factor serum concentrations were 974 +/- 173 pg/ml compared with 473 +/- 85 pg/ml (P = .023) and interleukin-6 serum concentrations were 129 +/- 45 compared with 19 +/- 5 ng/ml (P = .005) in the control and treated groups, respectively. The duration of shock and the occurrence of complications were similar in both groups. The mortality rate was 36% in the control group and 25% in the treated group (P = .317; odds ratio, 0.76; 95% confidence interval, 0.46-1.26). This trend disappeared after correction for unbalances in risk factors at randomization using a logistic regression model. These results suggest that anti-j5 plasma did not affect the course or mortality of severe infectious purpura in children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combining cell surface phenotyping with functional analysis, human CD8+ T cells have been divided into several subsets which are being studied extensively in diverse physiological situations, such as viral infection, cancer and ageing. In particular, so-called terminally differentiated effector cells possess a CD45RA+ CCR7- CD27- CD28- phenotype, contain perforin and, in different models, have been shown to exert direct ex vivo killing and to release interleukins upon both antigen-nonspecific and -specific stimulation. Using HLA class I multimers, we have identified a high frequency of peripheral CD8+ T cells that recognize a peptide derived from the self protein cytokeratin 18 presented by the HLA-A*0201 molecule. These cells can be detected in approximately 15% of the HLA-A2-positive healthy donors tested. A detailed analysis revealed that they must have divided extensively in vivo, have an effector cell phenotype and express various natural killer cell-associated receptors. Interestingly, however, they remained unresponsive to antigen-specific stimulation in vitro in terms of cytotoxicity and cytokine secretion. Thus, cytokeratin 18-specific cells constitute a frequently encountered, new CD8+ T lymphocyte subpopulation without classical effector status and with so far unknown function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Half of the patients with end-stage heart failure suffer from persistent atrial fibrillation (AF). Atrial kick (AK) accounts for 10-15% of the ejection fraction. A device restoring AK should significantly improve cardiac output (CO) and possibly delay ventricular assist device (VAD) implantation. This study has been designed to assess the mechanical effects of a motorless pump on the right chambers of the heart in an animal model. METHODS: Atripump is a dome-shaped biometal actuator electrically driven by a pacemaker-like control unit. In eight sheep, the device was sutured onto the right atrium (RA). AF was simulated with rapid atrial pacing. RA ejection fraction (EF) was assessed with intracardiac ultrasound (ICUS) in baseline, AF and assisted-AF status. In two animals, the pump was left in place for 4 weeks and then explanted. Histology examination was carried out. The mean values for single measurement per animal with +/-SD were analysed. RESULTS: The contraction rate of the device was 60 per min. RA EF was 41% in baseline, 7% in AF and 21% in assisted-AF conditions. CO was 7+/-0.5 l min(-1) in baseline, 6.2+/-0.5 l min(-1) in AF and 6.7+/-0.5 l min(-1) in assisted-AF status (p<0.01). Histology of the atrium in the chronic group showed chronic tissue inflammation and no sign of tissue necrosis. CONCLUSIONS: The artificial muscle restores the AK and improves CO. In patients with end-stage cardiac failure and permanent AF, if implanted on both sides, it would improve CO and possibly delay or even avoid complex surgical treatment such as VAD implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Chest pain raises concern for the possibility of coronary heart disease. Scoring methods have been developed to identify coronary heart disease in emergency settings, but not in primary care. METHODS: Data were collected from a multicenter Swiss clinical cohort study including 672 consecutive patients with chest pain, who had visited one of 59 family practitioners' offices. Using delayed diagnosis we derived a prediction rule to rule out coronary heart disease by means of a logistic regression model. Known cardiovascular risk factors, pain characteristics, and physical signs associated with coronary heart disease were explored to develop a clinical score. Patients diagnosed with angina or acute myocardial infarction within the year following their initial visit comprised the coronary heart disease group. RESULTS: The coronary heart disease score was derived from eight variables: age, gender, duration of chest pain from 1 to 60 minutes, substernal chest pain location, pain increases with exertion, absence of tenderness point at palpation, cardiovascular risks factors, and personal history of cardiovascular disease. Area under the receiver operating characteristics curve was of 0.95 with a 95% confidence interval of 0.92; 0.97. From this score, 413 patients were considered as low risk for values of percentile 5 of the coronary heart disease patients. Internal validity was confirmed by bootstrapping. External validation using data from a German cohort (Marburg, n = 774) revealed a receiver operating characteristics curve of 0.75 (95% confidence interval, 0.72; 0.81) with a sensitivity of 85.6% and a specificity of 47.2%. CONCLUSIONS: This score, based only on history and physical examination, is a complementary tool for ruling out coronary heart disease in primary care patients complaining of chest pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the role of arginine vasopressin (AVP) in congestive heart failure (CHF), 10 patients with CHF refractory to conventional treatment were studied before and 60 minutes after intravenous administration of 5 micrograms/kg of d(CH2)5Tyr(Me)AVP, a specific antagonist of AVP at the vascular receptor level. Heart rate, systemic arterial pressure, pulmonary arterial pressure, pulmonary capillary wedge pressure, cardiac index by thermodilution and cutaneous blood flow by laser-Doppler technique were measured. In 9 patients with no significant hemodynamic and cutaneous blood flow response to the AVP antagonist, baseline values (mean +/- standard deviation) were: heart rate, 77 +/- 14 beats/min; systemic arterial pressure, 120/79 +/- 18/8 mm Hg; pulmonary arterial pressure, 42/21 +/- 12/8 mm Hg; pulmonary capillary wedge pressure, 19 +/- 7 mm Hg; cardiac index, 2.2 +/- 0.6 liters/min/m2; plasma AVP, 2.3 +/- 0.8 pg/ml; and plasma osmolality, 284 +/- 14 mosm/kg H2O. The tenth patient had the most severe CHF. His plasma AVP level was 55 pg/ml and plasma osmolality was 290 mosm/kg. He responded to the AVP antagonist with a decrease in systemic arterial pressure from 115/61 to 79/41 mm Hg, in pulmonary arterial pressure from 58/31 to 33/13 mm Hg and in pulmonary capillary wedge pressure from 28 to 15 mm Hg. Simultaneously, cardiac index increased from 1.1 to 2.2 liters/min/m2 and heart rate from 113 to 120 beats/min; cutaneous blood flow increased 5-fold.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-dose dobutamine magnetic resonance stress testing has been shown to be superior to dobutamine stress echocardiography for diagnosis of coronary artery disease (CAD). We determined the feasibility of quantitative myocardial tagging during low- and high-dose dobutamine stress and tested the ability of global systolic and diastolic quantitative parameters to identify patients with significant CAD. Twenty-five patients suspected of having significant CAD were examined with a standard high-dose dobutamine/atropine stress magnetic resonance protocol (1.5-T scanner, Philips). All patients underwent invasive coronary angiography as the standard of reference for the presence (n = 13) or absence (n = 12) of significant CAD. During low-dose dobutamine stress, systolic (circumferential shortening, systolic rotation, and systolic rotation velocity) and diastolic (velocity of circumferential lengthening and diastolic rotation velocity) parameters changed significantly in patients without CAD (all P < 0.05 vs. rest) but not in patients with CAD. Identification of patients without and with CAD during low-dose stress was possible using the diastolic parameter of "time to peak untwist." At high-dose stress, none of the global systolic or diastolic parameters showed the potential to identify the presence of significant CAD. With myocardial tagging, a quantitative analysis of systolic and diastolic function was feasible during low- and high-dose dobutamine stress. In our study, the diastolic parameter of time to peak untwist as assessed during low-dose dobutamine stress was the most promising global parameter for identification of patients with significant CAD. Thus quantitative myocardial tagging may become a tool that reduces the need for high-dose dobutamine stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The aim of this study was to determine the seroprevalence of Hepatitis E virus (HEV) among blood donors in southwest Switzerland.Background: HEV is recognized as a food-borne disease in industrialized countries, transmitted mainly through pork meat. Cases of transmission through blood transfusion have also been reported. Recent studies have revealed seroprevalence rates of 13.5%, 16.6% and 20.6% among blood donors in England, France and Denmark, respectively.Methods: We analyzed 550 consecutive blood donor samples collected in the region of Lausanne, canton of Vaud, Switzerland, for the presence of anti-HEV IgG, using the MP Diagnostics HEV ELISA kit. For each donor, we documented age, sex and alanine aminotransferase (ALT) value.Results: The study panel was composed of 332 men (60.4%) and 218 women (39.6%). Overall, anti-HEV IgG was found in 27 of 550 samples (4.9%). The seroprevalence was 5.4% (18/332) in men and 4.1% (9/218) in women. The presence of anti-HEV IgG was not correlated with age, gender or ALT values. However, we observed a peak in seroprevalence of 5.3% in individuals aged 51 to 70 years old.Conclusions: Compared with other European countries, HEV seroprevalence among blood donors in southwest Switzerland is low. The low seroprevalence may be explained by the sensitivity of commercial tests used and/or the strict regulation of animal and meat imports. Data regarding HEV prevalence in Swiss livestock are lacking and merit exploration.