361 resultados para GROUNDWATER MONITORING


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In addition to the monographs which were published last year by the working group "Drug Monitoring" of the Swiss Society of Clinical Chemistry (SSCC) [1], new monographs have been written. The aim of these monographs is to give an overview of the most important information necessary for ordering a drug analysis or interpreting the results. Therefore, the targeted readers comprise laboratory health professionals and all receivers of laboratory reports. There is information provided on the indication for therapeutic drug monitoring, protein binding, metabolic pathways and enzymes involved, elimination half-life and elimination routes, and on therapeutic or toxic concentrations. Preanalytical considerations are of particular importance for therapeutic drug monitoring. Therefore, information is provided regarding a reasonable timing for the determination of drug concentrations as well as steady-state concentrations after changing the dose. Furthermore, the stability of the drug and its metabolite(s) after blood sampling is described. For readers with a specific interest in drug analysis, references to important publications are given. The number of monographs will be continuously enlarged. The updated files are presented on the homepage of the SSCC (www.sscc.ch).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whereas during the last few years handling of the transcutaneous PO2 (tcPO2) and PCO2 (tcPCO2) sensor has been simplified, the high electrode temperature and the short application time remain major drawbacks. In order to determine whether the application of a topical metabolic inhibitor allows reliable measurement at a sensor temperature of 42 degrees C for a period of up to 12 h, we performed a prospective, open, nonrandomized study in a sequential sample of 20 critically ill neonates. A total of 120 comparisons (six repeated measurements per patient) between arterial and transcutaneous values were obtained. Transcutaneous values were measured with a control sensor at 44 degrees C (conventional contact medium, average application time 3 h) and a test sensor at 42 degrees C (Eugenol solution, average application time 8 h). Comparison of tcPO2 and PaO2 at 42 degrees C (Eugenol solution) showed a mean difference of +0.16 kPa (range +1.60 to -2.00 kPa), limits of agreement +1.88 and -1.56 kPa. Comparison of tcPO2 and PaO2 at 44 degrees C (control sensor) revealed a mean difference of +0.02 kPa (range +2.60 to -1.90 kPa), limits of agreement +2.12 and -2.08 kPa. Comparison of tcPCO2 and PaCO2 at 42 degrees C (Eugenol solution) showed a mean difference of +0.91 (range +2.30 to +0.10 kPa), limits of agreement +2.24 and -0.42 kPa. Comparison of tcPCO2 and PaCO2 at 44 degrees C (control sensor) revealed a mean difference of +0.63 kPa (range 1.50 to -0.30 kPa), limits of agreement +1.73 and -0.47 kPa. CONCLUSION: Our results show that the use of an Eugenol solution allows reliable measurement of tcPO2 at a heating temperature of 42 degrees C; the application time can be prolongued up to a maximum of 12 h without aggravating the skin lesions. The performance of the tcPCO2 monitor was slightly worse at 42 degrees C than at 44 degrees C suggesting that for the Eugenol solution the metabolic offset should be corrected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le monitoring de la problématique du cannabis en Suisse constitue un ensemble de travaux qui permettent le suivi de la situation au niveau national et qui sont mis en oeuvre par un consortium d'institutions de recherche. Ce monitoring comprend l'étude présentée dans ce rapport, l'étude sentinelle. Celle-ci s'intéresse à l'évolution de la situation en matière de cannabis ainsi qu'à la gestion de cette situation au niveau local. Il s'agit de répondre aux questions suivantes : - quelle est la situation en matière de consommation de cannabis et de marché et quelle est son évolution ? - quels sont les principaux problèmes rencontrés sur le terrain ? - quelles sont les mesures et interventions qui ont été développées dans ce domaine ? Pour y répondre, on a choisi de suivre la situation dans quatre cantons suisses dits "sentinelle" (St-Gall, Tessin, Vaud, Zurich). Les critères de choix de ces cantons font appel à leur taille, au rapport ville/campagne et à la présence de frontière avec des états voisins, à la langue, au type de politique drogue pratiqué. Dans chaque canton on a constitué des panels d'experts formés par des profes-sionnels de terrain dans trois domaines différents (santé et social, école, police et justice). Leurs observations ainsi que les données cantonales disponibles sont récoltées et discutées lors d'un workshop et analysées sur plusieurs années. Le présent rapport fait état des résultats des quatre workshops de suivi (2005, 2006, 2008, 2009). [Résumé, p. 5]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunotherapy is defined as the treatment of disease by inducing, enhancing, or suppressing an immune response, whereas preventive vaccination is intended to prevent the development of diseases in healthy subjects. Most successful prophylactic vaccines rely on the induction of high titers of neutralizing antibodies. It is generally thought that therapeutic vaccination requires induction of robust T-cell mediated immunity. The diverse array of potential or already in use immunotherapeutic and preventive agents all share the commonality of stimulating the immune system. Hence, measuring those vaccination-induced immune responses gives the earliest indication of vaccine take and its immune modulating effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of some cancer patients has shifted from traditional, non-specific cytotoxic chemotherapy to chronic treatment with molecular targeted therapies. Imatinib mesylate, a selective inhibitor of tyrosine kinases (TKIs) is the most prominent example of this new era and has opened the way to the development of several additional TKIs, including sunitinib, nilotinib, dasatinib, sorafenib and lapatinib, in the treatment of various hematological malignancies and solid tumors. All these agents are characterized by an important inter-individual pharmacokinetic variability, are at risk for drug interactions, and are not devoid of toxicity. Additionally, they are administered for prolonged periods, anticipating the careful monitoring of their plasma exposure via Therapeutic Drug Monitoring (TDM) to be an important component of patients' follow-up. We have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 100 microL of plasma for the simultaneous determination of the six major TKIs currently in use. Plasma is purified by protein precipitation and the supernatant is diluted in ammonium formate 20 mM (pH 4.0) 1:2. Reverse-phase chromatographic separation of TKIs is obtained using a gradient elution of 20 mM ammonium formate pH 2.2 and acetonitrile containing 1% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 20 min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<9.6%), overall process efficiency (87.1-104.2%), as well as TKIs short- and long-term stability in plasma. The method is precise (inter-day CV%: 1.3-9.4%), accurate (-9.2 to +9.9%) and sensitive (lower limits of quantification comprised between 1 and 10 ng/mL). This is the first broad-range LC-MS/MS assay covering the major currently in-use TKIs. It is an improvement over previous methods in terms of convenience (a single extraction procedure for six major TKIs, reducing significantly the analytical time), sensitivity, selectivity and throughput. It may contribute to filling the current knowledge gaps in the pharmacokinetics/pharmacodynamics relationships of the latest TKIs developed after imatinib and better define their therapeutic ranges in different patient populations in order to evaluate whether a systematic TDM-guided dose adjustment of these anticancer drugs could contribute to minimize the risk of major adverse reactions and to increase the probability of efficient, long lasting, therapeutic response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The imatinib trough plasma concentration (C(min)) correlates with clinical response in cancer patients. Therapeutic drug monitoring (TDM) of plasma C(min) is therefore suggested. In practice, however, blood sampling for TDM is often not performed at trough. The corresponding measurement is thus only remotely informative about C(min) exposure. Objectives: The objectives of this study were to improve the interpretation of randomly measured concentrations by using a Bayesian approach for the prediction of C(min), incorporating correlation between pharmacokinetic parameters, and to compare the predictive performance of this method with alternative approaches, by comparing predictions with actual measured trough levels, and with predictions obtained by a reference method, respectively. Methods: A Bayesian maximum a posteriori (MAP) estimation method accounting for correlation (MAP-ρ) between pharmacokinetic parameters was developed on the basis of a population pharmacokinetic model, which was validated on external data. Thirty-one paired random and trough levels, observed in gastrointestinal stromal tumour patients, were then used for the evaluation of the Bayesian MAP-ρ method: individual C(min) predictions, derived from single random observations, were compared with actual measured trough levels for assessment of predictive performance (accuracy and precision). The method was also compared with alternative approaches: classical Bayesian MAP estimation assuming uncorrelated pharmacokinetic parameters, linear extrapolation along the typical elimination constant of imatinib, and non-linear mixed-effects modelling (NONMEM) first-order conditional estimation (FOCE) with interaction. Predictions of all methods were finally compared with 'best-possible' predictions obtained by a reference method (NONMEM FOCE, using both random and trough observations for individual C(min) prediction). Results: The developed Bayesian MAP-ρ method accounting for correlation between pharmacokinetic parameters allowed non-biased prediction of imatinib C(min) with a precision of ±30.7%. This predictive performance was similar for the alternative methods that were applied. The range of relative prediction errors was, however, smallest for the Bayesian MAP-ρ method and largest for the linear extrapolation method. When compared with the reference method, predictive performance was comparable for all methods. The time interval between random and trough sampling did not influence the precision of Bayesian MAP-ρ predictions. Conclusion: Clinical interpretation of randomly measured imatinib plasma concentrations can be assisted by Bayesian TDM. Classical Bayesian MAP estimation can be applied even without consideration of the correlation between pharmacokinetic parameters. Individual C(min) predictions are expected to vary less through Bayesian TDM than linear extrapolation. Bayesian TDM could be developed in the future for other targeted anticancer drugs and for the prediction of other pharmacokinetic parameters that have been correlated with clinical outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tobacco consumption is a global epidemic responsible for a vast burden of disease. With pharmacological properties sought-after by consumers and responsible for addiction issues, nicotine is the main reason of this phenomenon. Accordingly, smokeless tobacco products are of growing popularity in sport owing to potential performance enhancing properties and absence of adverse effects on the respiratory system. Nevertheless, nicotine does not appear on the 2011 World Anti-Doping Agency (WADA) Prohibited List or Monitoring Program by lack of a comprehensive large-scale prevalence survey. Thus, this work describes a one-year monitoring study on urine specimens from professional athletes of different disciplines covering 2010 and 2011. A method for the detection and quantification of nicotine, its major metabolites (cotinine, trans-3-hydroxycotinine, nicotine-N′-oxide and cotinine-N-oxide) and minor tobacco alkaloids (anabasine, anatabine and nornicotine) was developed, relying on ultra-high pressure liquid chromatography coupled to triple quadrupole mass spectrometry (UHPLC-TQ-MS/MS). A simple and fast dilute-and-shoot sample treatment was performed, followed by hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS) operated in positive electrospray ionization (ESI) mode with multiple reaction monitoring (MRM) data acquisition. After method validation, assessing the prevalence of nicotine consumption in sport involved analysis of 2185 urine samples, accounting for 43 different sports. Concentrations distribution of major nicotine metabolites, minor nicotine metabolites and tobacco alkaloids ranged from 10 (LLOQ) to 32,223, 6670 and 538 ng/mL, respectively. Compounds of interest were detected in trace levels in 23.0% of urine specimens, with concentration levels corresponding to an exposure within the last three days for 18.3% of samples. Likewise, hypothesizing conservative concentration limits for active nicotine consumption prior and/or during sport practice (50 ng/mL for nicotine, cotinine and trans-3-hydroxycotinine and 25 ng/mL for nicotine-N′-oxide, cotinine-N-oxide, anabasine, anatabine and nornicotine) revealed a prevalence of 15.3% amongst athletes. While this number may appear lower than the worldwide smoking prevalence of around 25%, focusing the study on selected sports highlighted more alarming findings. Indeed, active nicotine consumption in ice hockey, skiing, biathlon, bobsleigh, skating, football, basketball, volleyball, rugby, American football, wrestling and gymnastics was found to range between 19.0 and 55.6%. Therefore, considering the adverse effects of smoking on the respiratory tract and numerous health threats detrimental to sport practice at top level, likelihood of smokeless tobacco consumption for performance enhancement is greatly supported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physicians who frequently perform fluoroscopic examinations are exposed to high intensity radiation fields. The exposure monitoring is performed with a regular personal dosimeter under the apron in order to estimate the effective dose. However, large parts of the body are not protected by the apron (e.g. arms, head). Therefore, it is recommended to wear a supplemental dosimeter over the apron to obtain a better representative estimate of the effective dose. The over-apron dosimeter can also be used to estimate the eye lens dose. The goal of this study was to investigate the relevance of double dosimetry in interventional radiology. First the calibration procedure of the dosimeters placed over the apron was tested. Then, results of double dosimetry during the last five years were analyzed. We found that the personal dose equivalent measured over a lead apron was underestimated by ∼20% to ∼40% for X-ray beam qualities used in radiology. Measurements made over five-year period confirm that the use of a single under-apron dosimeter is inadequate for personnel monitoring. Relatively high skin dose (>10 mSv/month) would have remained undetected without a second dosimeter placed on the apron.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nonadherence to treatment is a common problem in the clinical management of hypercholesterolemic patients. This study was carried out with the aim of monitoring the daily compliance to a 6-month course of lipid-lowering therapy, using a microelectronic device, the Medication Event Monitoring System (MEMS), versus pill count. Forty men with primary hypercholesterolemia were prescribed fluvastatin 1 x 40 mg daily, provided in a MEMS package to record the date and time of each opening of the pillbox. Thirty-nine of 40 patients (98%) completed the study. Total cholesterol and LDL cholesterol levels decreased significantly (18% and 25%, p < 0.001) during the 6-month therapy period. A high mean rate of compliance was achieved by MEMS using the following three indexes--compliance to total prescribed dose (88.8% +/- 13.5%), compliance to prescribed days (82.4% +/- 19.5%), and compliance to prescribed time of day (81.86% +/- 19.5%)--and by pill count (93.4% +/- 9.5%). In addition, the MEMS provided some patterns of nonadherence to medication, undetectable by pill count alone, such as a drug holiday in 38% of cases, a drug omission for more than 7 consecutive days in 9% of cases, and, conversely, use of more than the one prescribed daily dose in 47% of cases. A significant correlation between the rate of compliance and the decrease in LDL cholesterol was observed only when the compliance was assessed by MEMS. The results indicate that MEMS is a useful tool for monitoring compliance in clinical practice and may possibly increase adherence to long-term lipid-lowering therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pseudomonas fluorescens strain CHA0 is able to protect plants against a variety of pathogens, notably by producing the two antimicrobial compounds 2,4-diacetylphloroglucinol (DAPG) and pyoluteorin (PLT). The regulation of the expression of these compounds is affected by many biotic factors, such as fungal pathogens, rhizosphere bacteria as well as plant species. Therefore, the influence of some plant phenolic compounds on the expression of DAPG and PLT biosynthetic genes has been tested using GFP-based reporter, monitored by standard fluometry and flow cytometry. In situ experiments were also performed with cucumber plants. We found that several plant metabolites such as IAA and umbelliferone are able to modify significantly the expression of DAPG and PLT. The use of flow cytometry with autofluorescents proteins seems to be a promising method to study rhizobacteria-plant interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peri-insular hemispherotomy is a surgical technique used in the treatment of drug-resistant epilepsy of hemispheric origin. It is based on the exposure of insula and semi-circular sulci, providing access to the lateral ventricle through a supra- and infra-insular window. From inside the ventricle, a parasagittal callosotomy is performed. The basal and medial portion of the frontal lobe is isolated. Projections to the anterior commissure are interrupted at the time of amygdala resection. The hippocampal tail and fimbria-fornix are disrupted posteriorly. We report our experience of 18 cases treated with this approach. More than half of them presented with congenital epilepsy. Neuronavigation was useful in precisely determining the center and extent of the craniotomy, as well as the direction of tractotomies and callosotomy, allowing minimal exposure and blood loss. Intra-operative monitoring by scalp EEG on the contralateral hemisphere was used to follow the progression of the number of interictal spikes during the disconnection procedure. Approximately 90% of patients were in Engel's Class I. We observed one case who presented with transient postoperative neurological deterioration probably due to CSF overdrainage and documented one case of incomplete disconnection in a patient presenting with hemimegalencephaly who needed a second operation. We observed a good correlation between a significant decrease in the number of spikes at the end of the procedure and seizure outcome. Peri-insular hemispherotomy provides a functional disconnection of the hemisphere with minimal resection of cerebral tissue. It is an efficient technique with a low complication rate. Intra-operative EEG monitoring might be used as a predictive factor of completeness of the disconnection and consequently, seizure outcome.