101 resultados para Frozen storage stability
Resumo:
Millions of blood products are transfused every year; many lives are thus directly concerned by transfusion. The three main labile blood products used in transfusion are erythrocyte concentrates, platelet concentrates and fresh frozen plasma. Each of these products has to be stored according to its particular components. However, during storage, modifications or degradation of those components may occur, and are known as storage lesions. Thus, biomarker discovery of in vivo blood aging as well as in vitro labile blood products storage lesions is of high interest for the transfusion medicine community. Pre-analytical issues are of major importance in analyzing the various blood products during storage conditions as well as according to various protocols that are currently used in blood banks for their preparations. This paper will review key elements that have to be taken into account in the context of proteomic-based biomarker discovery applied to blood banking.
Stability-dependent behavioural and electro-cortical reorganizations during bimanual switching tasks
Resumo:
AIMS: To test the hypothesis that postural stability would be more affected during acute exposure in hypobaric (HH) than in normobaric (NH) hypoxia.¦METHODS: In separate trials, 12 subjects stood on a posturographic platform for two successive 25.6 sec tests in three conditions: eyes open (EO), eyes closed (EC), and verbal dual task (DT). Ambient pressure in O(2) was matched between HH and NH at 1700 and 3000 m, respectively.¦RESULTS: Compared to NH, the length of Centre of Pression trajectory in Y-axis was increased (p<0.05) in HH for EO at 1700 m, EC at 1700 and 3000 m, and for DT at 1700 m, whereas the variance of speed of CoP was decreased (p<0.05) in EO, EC, and DT at 1700 m. Compared to normobaric normoxia (NN; 400 m), the surface of CoP trajectory was increased (p<0.05) in HH in EO and EC at 3000 m.¦CONCLUSIONS: HH deteriorated postural stability in the antero-posterior plane, for the variance of speed and the surface of CoP in 3 conditions, whereas no difference was observed between NH and NN. These results suggest that hypobaria instead of hypoxia per se plays an important role to the altered balance classically reported in altitude.
Resumo:
Studies of hybrid zones can inform our understanding of reproductive isolation and speciation. Two species of brown lemur (Eulemur rufifrons and E. cinereiceps) form an apparently stable hybrid zone in the Andringitra region of south-eastern Madagascar. The aim of this study was to identify factors that contribute to this stability. We sampled animals at 11 sites along a 90-km transect through the hybrid zone and examined variation in 26 microsatellites, the D-loop region of mitochondrial DNA, six pelage and nine morphological traits; we also included samples collected in more distant allopatric sites. Clines in these traits were noncoincident, and there was no increase in either inbreeding coefficients or linkage disequilibrium at the centre of the zone. These results could suggest that the hybrid zone is maintained by weak selection against hybrids, conforming to either the tension zone or geographical selection-gradient model. However, a closer examination of clines in pelage and microsatellites indicates that these clines are not sigmoid or stepped in shape but instead plateau at their centre. Sites within the hybrid zone also occur in a distinct habitat, characterized by greater seasonality in precipitation and lower seasonality in temperature. Together, these findings suggest that the hybrid zone may follow the bounded superiority model, with exogenous selection favouring hybrids within the transitional zone. These findings are noteworthy, as examples supporting the bounded superiority model are rare and may indicate a process of ecologically driven speciation without geographical isolation.
Resumo:
In yeast, microtubules are dynamic filaments necessary for spindle and nucleus positioning, as well as for proper chromosome segregation. We identify a function for the yeast gene BER1 (Benomyl REsistant 1) in microtubule stability. BER1 belongs to an evolutionary conserved gene family whose founding member Sensitivity to Red light Reduced is involved in red-light perception and circadian rhythms in Arabidopsis. Here, we present data showing that the ber1Delta mutant is affected in microtubule stability, particularly in presence of microtubule-depolymerising drugs. The pattern of synthetic lethal interactions obtained with the ber1Delta mutant suggests that Ber1 may function in N-terminal protein acetylation. Our work thus suggests that microtubule stability might be regulated through this post-translational modification on yet-to-be determined proteins
Resumo:
Soil pollution with hexachlorocyclohexane (HCH) has caused serious environmental problems. Here we describe the targeted degradation of all HCH isomers by applying the aerobic bacterium Sphingobium indicum B90A. In particular, we examined possibilities for large-scale cultivation of strain B90A, tested immobilization, storage and inoculation procedures, and determined the survival and HCH-degradation activity of inoculated cells in soil. Optimal growth of strain B90A was achieved in glucose-containing mineral medium and up to 65% culturability could be maintained after 60 days storage at 30 degrees C by mixing cells with sterile dry corncob powder. B90A biomass produced in water supplemented with sugarcane molasses and immobilized on corncob powder retained 15-20% culturability after 30 days storage at 30 degrees C, whereas full culturability was maintained when cells were stored frozen at -20 degrees C. On the contrary, cells stored on corncob degraded gamma-HCH faster than those that had been stored frozen, with between 15 and 85% of gamma-HCH disappearance in microcosms within 20 h at 30 degrees C. Soil microcosm tests at 25 degrees C confirmed complete mineralization of [(14)C]-gamma-HCH by corncob-immobilized strain B90A. Experiments conducted in small pits and at an HCH-contaminated agricultural site resulted in between 85 and 95% HCH degradation by strain B90A applied via corncob, depending on the type of HCH isomer and even at residual HCH concentrations. Up to 20% of the inoculated B90A cells survived under field conditions after 8 days and could be traced among other soil microorganisms by a combination of natural antibiotic resistance properties, unique pigmentation and PCR amplification of the linA genes. Neither the addition of corncob nor of corncob immobilized B90A did measurably change the microbial community structure as determined by T-RFLP analysis. Overall, these results indicate that on-site aerobic bioremediation of HCH exploiting the biodegradation activity of S. indicum B90A cells stored on corncob powder is a promising technology.
Resumo:
In August 2008, reactivation of the Little Salmon Lake landslide occurred. During this event, hundreds of conical mounds of variable size and composition formed in the deposition zone. The characteristics of these landforms are described and a potential mechanism for their formation is proposed. A preliminary slope stability analysis of the 2007 Mount Steele rock and ice avalanche was also undertaken. The orientation of very high persistence (>20 m long) structural planes (e.g., faults, joints and bedding) within bedrock in the source zone was obtained using an airborne-LiDAR digital elevation model and the software COLTOP-3D. Using these discontinuity orientation measurements, kinematic, surface wedge and simple three-dimensional distinct element slope stability analyses were performed.
Resumo:
This study investigated behavioural and electro-cortical reorganizations accompanying intentional switching between two distinct bimanual coordination tapping modes (In-phase and Anti-phase) that differ in stability when produced at the same movement rate. We expected that switching to a less stable tapping mode (In-to-Anti switching) would lead to larger behavioural perturbations and require supplementary neural resources than switching to a more stable tapping mode (Anti-to-In switching). Behavioural results confirmed that the In-to-Anti switching lasted longer than the Anti-to-In switching. A general increase in attention-related neural activity was found at the moment of switching for both conditions. Additionally, two condition-dependent EEG reorganizations were observed. First, a specific increase in cortico-cortical coherence appeared exclusively during the In-to-Anti switching. This result may reflect a strengthening in inter-regional communication in order to engage in the subsequent, less stable, tapping mode. Second, a decrease in motor-related neural activity (increased beta spectral power) was found for the Anti-to-In switching only. The latter effect may reflect the interruption of the previous, less stable, tapping mode. Given that previous results on spontaneous Anti-to-In switching revealing an inverse pattern of EEG reorganization (decreased beta spectral power), present findings give new insight on the stability-dependent neural correlates of intentional motor switching. © 2010 Elsevier Ireland Ltd. All rights reserved
Resumo:
There has been a long standing desire to produce thick (up to 500 nm) cryo-sections of fully hydrated cells and tissue for high-resolution analysis in their natural state by cryo-transmission electron microscopy. Here, we present a method that can successfully produce sections (lamellas in FIB-SEM terminology) of fully hydrated, unstained cells from high-pressure frozen samples by focused ion beam (FIB) milling. The samples are therefore placed in thin copper tubes and vitrified by high-pressure freezing. For transfer, handling and subsequent milling, the tubes are placed in a novel connective device (ferrule) that protects the sample from devitrification and contamination and passes through all operation steps. A piezo driven sample positioning stage (cryo-nano-bench, CNB) with three degrees of freedom was additionally developed to enable accurate milling of frozen-hydrated lamellas. With the CNB, high-pressure frozen samples can be milled to produce either thin lamellas (<100 nm), for direct imaging by high-resolution cryo-TEM or thicker lamellas (300-500 nm) for cryo-electron tomography. The sample remains vitreous throughout the process by using the presented tools and methods. The results are an important step towards investigating larger cells and even tissue in there natural state which in the end will enable us to gain better insights into cellular processes.
Resumo:
The metabolic balance method was performed on three men to investigate the fate of large excesses of carbohydrate. Glycogen stores, which were first depleted by diet (3 d, 8.35 +/- 0.27 MJ [1994 +/- 65 kcal] decreasing to 5.70 +/- 1.03 MJ [1361 +/- 247 kcal], 15% protein, 75% fat, 10% carbohydrate) and exercise, were repleted during 7 d carbohydrate overfeeding (11% protein, 3% fat, and 86% carbohydrate) providing 15.25 +/- 1.10 MJ (3642 +/- 263 kcal) on the first day, increasing progressively to 20.64 +/- 1.30 MJ (4930 +/- 311 kcal) on the last day of overfeeding. Glycogen depletion was again accomplished with 2 d of carbohydrate restriction (2.52 MJ/d [602 kcal/d], 85% protein, and 15% fat). Glycogen storage capacity in man is approximately 15 g/kg body weight and can accommodate a gain of approximately 500 g before net lipid synthesis contributes to increasing body fat mass. When the glycogen stores are saturated, massive intakes of carbohydrate are disposed of by high carbohydrate-oxidation rates and substantial de novo lipid synthesis (150 g lipid/d using approximately 475 g CHO/d) without postabsorptive hyperglycemia.
Resumo:
The Hi·Art II Helical TomoTherapy (HT) unit is equipped with a built-in onboard MVCT detector used for patient imaging and beam monitoring. Our aim was to study the detector stability for treatment beam measurements. We studied the MVCT detector response with the 6 MV photon beam over time, throughout short-term (during an irradiation) and long-term (two times 50 days) periods. Our results show a coefficient of variation ≤ 1% for detector chambers inside the beam (excluding beam gradients) for short- and long-term response of the MVCT detector. Larger variations were observed in beam gradients and an influence of the X-ray target where degradation was found. The results assume that an 'air scan' procedure is performed daily to recalibrate the detector with the imaging beam. On short term, the detector response stability is comparable to other devices. Long-term measure- ments during two 50-day periods show a good reproducibility.