79 resultados para ELECTRONIC EQUIPMENT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of electronic control devices has expanded worldwide during the last few years, the most widely used model being the Taser. However, the scientific knowledge about electronic control devices remains limited. We reviewed the medical literature to examine the potential implications of electronic devices in terms of morbidity and mortality, and to identify and evaluate all the existing experimental human studies. A single exposure of an electronic control device on healthy individuals can be assumed to be generally safe, according to 23 prospective human experimental studies and numerous volunteer exposures. In case series, however, electronic control devices could have deleterious effects when used in the field, in particular if persons receive multiple exposures, are intoxicated, show signs of "excited delirium," or present with medical comorbidities. As the use of electronic control devices continues to increase, the controversy about its safety, notably in potentially high-risk individuals, is still a matter of debate. The complications of electronic control device exposure are numerous but often recognizable, usually resulting from barbed dart injuries or from falls. Persons exposed to electronic control devices should therefore be fully examined, and traumatic lesions must be ruled out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Every medical practitioner is confronted on a daily basis with emergencies. Among these, life-threatening emergencies can have disastrous consequences in term of morbidity and mortality; 22 cardiac arrests and 10 deaths were reported among the 1,650 Swiss practices during a 5 year period. The occurrence of life-threatening emergencies at the office necessitates, according to the type and place of the practice, the skills of the practitioner and the organization of his practice, the implementation of procedures, equipments (for example room equipped with a defibrillator, respiratory nebulizer, splints, emergency drugs) and specific continuous education programs that should be encouraged and made available to the whole medical corporation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 ?g/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 ?g/ml) ?cdr1 ?cdr2 ?flu ?mdr1 ?can constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 ?g/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 ?g/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed 42 models from 14 brands of refill liquids for e-cigarettes for the presence of micro-organisms, diethylene glycol, ethylene glycol, hydrocarbons, ethanol, aldehydes, tobacco-specific nitrosamines, and solvents. All the liquids under scrutiny complied with norms for the absence of yeast, mold, aerobic microbes, Staphylococcus aureus, and Pseudomonas aeruginosa. Diethylene glycol, ethylene glycol and ethanol were detected, but remained within limits authorized for food and pharmaceutical products. Terpenic compounds and aldehydes were found in the products, in particular formaldehyde and acrolein. No sample contained nitrosamines at levels above the limit of detection (1 μg/g). Residual solvents such as 1,3-butadiene, cyclohexane and acetone, to name a few, were found in some products. None of the products under scrutiny were totally exempt of potentially toxic compounds. However, for products other than nicotine, the oral acute toxicity of the e-liquids tested seems to be of minor concern. However, a minority of liquids, especially those with flavorings, showed particularly high ranges of chemicals, causing concerns about their potential toxicity in case of chronic oral exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: In some countries, nicotine-containing electronic cigarettes (e-cigarettes) are considered a consumer product without specific regulations. In others (eg, Switzerland), the sale of e-cigarettes containing nicotine is forbidden, despite the eagerness of many smokers to obtain them. As scientific data about efficacy and long-term safety of these products are scarce, tobacco control experts are divided on how to regulate them. In order to gain consensus among experts to provide recommendations to health authorities, we performed a national consensus study. SETTING: We used a Delphi method with electronic questionnaires to bring together the opinion of Swiss experts on e-cigarettes. PARTICIPANTS: 40 Swiss experts from across the country. OUTCOME MEASURES: We measured the degree of consensus between experts on recommendations regarding regulation, sale, use of and general opinion about e-cigarettes containing nicotine. New recommendations and statements were added following the experts' answers and comments. RESULTS: There was consensus that e-cigarettes containing nicotine should be made available, but only under specific conditions. Sale should be restricted to adults, using quality standards, a maximum level of nicotine and with an accompanying list of authorised ingredients. Advertisement should be restricted and use in public places should be forbidden. CONCLUSIONS: These recommendations encompass three principles: (1) the reality principle, as the product is already on the market; (2) the prevention principle, as e-cigarettes provide an alternative to tobacco for actual smokers, and (3) the precautionary principle, to protect minors and non-smokers, since long-term effects are not yet known. Swiss authorities should design specific regulations to sell nicotine-containing e-cigarettes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'usage de cigarettes électroniques (vapotage) augmente chez les jeunes et les professionnels de la santé se sentent démunis. Ce court article donne quelques informations pratiques. L'usage (vapotage) de cigarettes électroniques (e-cigarettes) est un phénomène relativement récent qui est en train de prendre une ampleur inattendue, surtout chez les jeunes. Bien que les taux de prévalence soient extrêmement variables d'un pays à l'autre, ils sont en net augmentation: tant parmi ceux qui les ont seulement essayées que chez ceux qui les utilisent habituellement, les taux de prévalence ont doublé ou presque triplé en à peine une année. En outre, une proportion notable d'utilisateurs d'e-cigarettes (de 8 à 33% selon les études)n'avaient jamais fumé de cigarettes conventionnelles. Ce phénomène pourrait faire des e-cigarettes la porte d'entrée au tabagisme parmi les jeunes. Adolescents and electronic cigarettes: The use of electronic cigarettes (vaping) is increasing among young people and health professionals feel ill-prepared. This short article provides some practical information The use of electronic cigarettes (vaping) is increasing among young people and health professionals feel ill-prepared. This short article provides some practical information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To review the available knowledge on epidemiology and diagnoses of acute infections in children aged 2 to 59 months in primary care setting and develop an electronic algorithm for the Integrated Management of Childhood Illness to reach optimal clinical outcome and rational use of medicines. METHODS: A structured literature review in Medline, Embase and the Cochrane Database of Systematic Review (CDRS) looked for available estimations of diseases prevalence in outpatients aged 2-59 months, and for available evidence on i) accuracy of clinical predictors, and ii) performance of point-of-care tests for targeted diseases. A new algorithm for the management of childhood illness (ALMANACH) was designed based on evidence retrieved and results of a study on etiologies of fever in Tanzanian children outpatients. FINDINGS: The major changes in ALMANACH compared to IMCI (2008 version) are the following: i) assessment of 10 danger signs, ii) classification of non-severe children into febrile and non-febrile illness, the latter receiving no antibiotics, iii) classification of pneumonia based on a respiratory rate threshold of 50 assessed twice for febrile children 12-59 months; iv) malaria rapid diagnostic test performed for all febrile children. In the absence of identified source of fever at the end of the assessment, v) urine dipstick performed for febrile children <2 years to consider urinary tract infection, vi) classification of 'possible typhoid' for febrile children >2 years with abdominal tenderness; and lastly vii) classification of 'likely viral infection' in case of negative results. CONCLUSION: This smartphone-run algorithm based on new evidence and two point-of-care tests should improve the quality of care of <5 year children and lead to more rational use of antimicrobials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Very large molecular systems can be calculated with the so called CNDOL approximate Hamiltonians that have been developed by avoiding oversimplifications and only using a priori parameters and formulas from the simpler NDO methods. A new diagonal monoelectronic term named CNDOL/21 shows great consistency and easier SCF convergence when used together with an appropriate function for charge repulsion energies that is derived from traditional formulas. It is possible to obtain a priori molecular orbitals and electron excitation properties after the configuration interaction of single excited determinants with reliability, maintaining interpretative possibilities even being a simplified Hamiltonian. Tests with some unequivocal gas phase maxima of simple molecules (benzene, furfural, acetaldehyde, hexyl alcohol, methyl amine, 2,5 dimethyl 2,4 hexadiene, and ethyl sulfide) ratify the general quality of this approach in comparison with other methods. The calculation of large systems as porphine in gas phase and a model of the complete retinal binding pocket in rhodopsin with 622 basis functions on 280 atoms at the quantum mechanical level show reliability leading to a resulting first allowed transition in 483 nm, very similar to the known experimental value of 500 nm of "dark state." In this very important case, our model gives a central role in this excitation to a charge transfer from the neighboring Glu(-) counterion to the retinaldehyde polyene chain. Tests with gas phase maxima of some important molecules corroborate the reliability of CNDOL/2 Hamiltonians.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmortem imaging techniques, especially postmortem computed tomography, have become integral tools in forensic investigations. Multiphase postmortem computed tomography angiography (MPMCTA) visualizes the vascular system in detail and makes it possible to evaluate the perfusion of even the smallest vessels. Although the technique has been well described for adults, no pediatric cases have been reported and no pediatric protocol has been established for this type of investigation. We present the case a 7-year-old child for which we used a previously described MPMCTA protocol and adapted values of perfusion, with the same technical equipment as for adult cases. Our main objective was to propose a perfusion protocol adapted for the investigation of infants and children. Moreover, we discuss both the difficulties that we encountered and possible ways to further improve the investigation of pediatric cases by MPMCTA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: A surgical gastrostomy is mandatory in cases where a PEG is not feasible. Various minimally invasive techniques have been described, but many involve unusable materials in small children and/or have risk of disunion. We describe a technique for true Stamm gastrostomy performed by laparoscopy (LSG) with a purse string suture and four points of attachment onto the wall. METHOD: We reviewed 20 children who underwent an LSG from 2010 to 2013. After incision of the skin at the location planned for the gastrostomy, using three 3-5mm ports the stomach is fixed to the wall by three suspension stitches, which are entered and then emerged subcutaneously. A fourth stitch of attachment is used to make an award on the stomach and tie around the gastrostomy tube. RESULTS: Mean age was 4.2years, with 70% aged <2years. All children were malnourished, most often severely. All but two underwent a concomitant fundoplication. Feeding through the gastrostomy started on D0 or D1. Total feeding by gastrostomy was achieved in a mean duration of 2.9day. Mean hospital stay was 4.5days. There was no perioperative complication. Mean follow-up was 14months. Once, the balloon was accidently deflated and reinflated in the wall leading to its necrosis. Five peristomial granulomas were noticed. It was always possible to replace the tube by a gastrostomy device at least 6weeks after surgery. CONCLUSION: This new technique for true Stamm gastrostomy by laparoscopy reproduces exactly the one done by laparotomy, without special equipment. It can be made since the neonatal period, in all the circumstances when a laparoscopy is possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Occupational exposure to grain dust causes respiratory symptoms and pathologies. To decrease these effects, major changes have occurred in the grain processing industry in the last twenty years. However, there are no data on the effects of these changes on workers' respiratory health. OBJECTIVES: The aim of this study was to evaluate the respiratory health of grain workers and farmers involved in different steps of the processing industry of wheat, the most frequently used cereal in Europe, fifteen years after major improvements in collective protective equipment due to mechanisation. MATERIALS AND METHOD: Information on estimated personal exposure to wheat dust was collected from 87 workers exposed to wheat dust and from 62 controls. Lung function (FEV1, FVC, and PEF), exhaled nitrogen monoxide (FENO) and respiratory symptoms were assessed after the period of highest exposure to wheat during the year. Linear regression models were used to explore the associations between exposure indices and respiratory effects. RESULTS: Acute symptoms - cough, sneezing, runny nose, scratchy throat - were significantly more frequent in exposed workers than in controls. Increased mean exposure level, increased cumulative exposure and chronic exposure to more than 6 mg.m (-3) of inhaled wheat dust were significantly associated with decreased spirometric parameters, including FEV1 and PEF (40 ml and 123 ml.s (-1) ), FEV1 and FVC (0.4 ml and 0.5 ml per 100 h.mg.m (-3) ), FEV1 and FVC (20 ml and 20 ml per 100 h at >6 mg.m (-3) ). However, no increase in FENO was associated with increased exposure indices. CONCLUSIONS: The lung functions of wheat-related workers are still affected by their cumulative exposure to wheat dust, despite improvements in the use of collective protective equipment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La cigarette électronique produit de la vapeur à inhaler contenant du propylène-glycol, des arômes et de la nicotine libérée rapidement. 6,7% de la population suisse, surtout des fumeurs, ont essayé la cigarette électronique et 0,1% l'utilise quotidiennement. Malgré l'incertitude due au bas niveau de preuves, la cigarette électronique pourrait être efficace pour cesser ou réduire le tabagisme. La sécurité de la cigarette électronique est démontrée à court terme mais pas à long terme ; sa toxicité semble très inférieure à celle du tabac. Les non-fumeurs et les jeunes utilisent peu la cigarette électronique qui ne semble pas les amener au tabagisme. Les mesures de santé publique recommandées sont la régulation du produit avec contrôle de la qualité ainsi que l'interdiction d'usage dans les lieux publics, de publicité et de vente aux mineurs. Electronic cigarettes are devices producing vapour containing propylene-glycol, flavourings and quickly delivered nicotine. 6.7% of the Swiss population, mainly smokers, experimented the electronic cigarette while 0.1% use it daily. Despite uncertainty due to the low level of evidence, electronic cigarettes might be effective for smoking cessation and reduction. The safety of electronic cigarettes is demonstrated at short-term but not at long-term; however its eventual toxicity is likely to be much lower than tobacco. Use of electronic cigarettes by non-smokers and youth who do not smoke is low and seems unlikely to lead them to tobacco use. Recommended public health measures include product regulation with quality control, ban in public places, prohibition of advertising and sales to minors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les pistolets à impulsion électrique (PIE) sont de plus en plus fréquemment utilisés en Europe ces dernières années, le modèle le plus connu étant le Taser®. Les connaissances scientifiques concernant les PIE et leurs effets potentiels restent toutefois limitées. Nous avons conduit une revue de littérature afin d'évaluer les implications potentielles de leur utilisation en termes de sécurité, de morbidité et de mortalité. Une exposition unique chez un individu sain peut généralement être considérée comme peu dangereuse. Les sujets à risque de complications sont les individus exposés à de multiples décharges, les personnes sous l'influence de substances psychoactives, ceux qui montrent des signes d'agitation extrême, ou encore les individus présentant des comorbidités médicales. L'éventail des complications pouvant survenir lors de leur exposition est large et inclut les lésions provoquées par les impacts des électrodes, les traumatismes liés à la chute induite par la paralysie transitoire ou des complications cardiovasculaires. Dans ce contexte, les personnes exposées doivent être examinées attentivement, et les éventuelles lésions traumatiques doivent être exclues. The use of electronic control devices (ECD), such as the Taser®, has increased in Europe over the past decade. However, scientific data concerning the potential health impact of ECD usage remains limited. We reviewed the scientific literature in order to evaluate the safety, mortality, and morbidity associated with ECD use. Exposure of a healthy individual to a single ECD electroshock can be considered generally safe. Complications can, however, occur if the patient is subject to multiple electroshocks, if the patient has significant medical comorbidities, or when exposure is associated with drug abuse or agitated delirium. The broad spectrum of potential complications associated with ECD exposure includes direct trauma caused by the ECD electrodes, injuries caused by the transient paralysis-induced fall, and cardiovascular events. An ECD-exposed patient requires careful examination during which traumatic injuries are actively sought out.