74 resultados para Criminal procedures
Resumo:
BACKGROUND: Meticulous steps and procedures are proposed in planning guidelines for the development of comprehensive multiyear plans for national immunization programmes. However, we know very little about whether the real-life experience of those who adopt these guidelines involves following these procedures as expected. Are these steps and procedures followed in practice? We examined the adoption and usage of the guidelines in planning national immunization programmes and assessed whether the recommendations in these guidelines are applied as consistently as intended. METHODS: We gathered information from the national comprehensive multiyear plans developed by 77 low-income countries. For each of the 11 components, we examined how each country applied the four recommended steps of situation analysis, problem prioritization, selection of interventions, and selection of indicators. We then conducted an analysis to determine the patterns of alignment of the comprehensive multiyear plans with those four recommended planning steps. RESULTS: Within the first 3Â years following publication of the guidelines, 66 (86%) countries used the tool to develop their comprehensive multiyear plans. The funding conditions attached to the use of these guidelines appeared to influence their rapid adoption and usage. Overall, only 33 (43%) countries fully applied all four recommended planning steps of the guidelines. CONCLUSIONS: Adoption and usage of the guidelines for the development of comprehensive multiyear plans for national immunization programmes were rapid. However, our findings show substantial variation between the proposed planning ideals set out in the guidelines and actual use in practice. A better understanding of factors that influence how recommendations in public health guidelines are applied in practice could contribute to improvements in guidelines design. It could also help adjust strategies used to introduce them into public health programmes, with the ultimate goal of a greater health impact.
Resumo:
Since January 2008-de facto 2012-medical physics experts (MPEs) are, by law, to be involved in the optimisation process of radiological diagnostic procedures in Switzerland. Computed tomography, fluoroscopy and nuclear medicine imaging units have been assessed for patient exposure and image quality. Large spreads in clinical practice have been observed. For example, the number of scans per abdominal CT examination went from 1 to 9. Fluoroscopy units showed, for the same device settings, dose rate variations up to a factor of 3 to 7. Quantitative image quality for positron emission tomography (PET)/CT examinations varied significantly depending on the local image reconstruction algorithms. Future work will be focused on promoting team cooperation between MPEs, radiologists and radiographers and on implementing task-oriented objective image quality indicators.
Resumo:
BACKGROUND: Radial maze tasks have been used to assess optimal foraging and spatial abilities in rodents. The spatial performance was based on a capacity to rely on a configuration of local and distant cues. We adapted maze procedures assessing the relative weight of local cues and distant landmarks for arm choice in humans. NEW METHOD: The procedure allowed testing memory of places in four experimental setups: a fingertip texture-groove maze, a tactile screen maze, a virtual radial maze and a walking size maze. During training, the four reinforced positions remained fixed relative to local and distal cues. During subsequent conflict trials, these frameworks were made conflictive in the prediction of reward locations. RESULTS: Three experiments showed that the relative weight of local and distal relational cues is affected by different factors such as cues' nature, visual access to the environment, real vs. virtual environment, and gender. A fourth experiment illustrated how a walking maze can be used with people suffering intellectual disability. COMPARISON WITH EXISTING METHODS: In our procedure, long-term (reference) and short-term (working) memory can be assessed. It is the first radial task adapted to human that enables dissociating local and distal cues, to provides an indication as to their relative salience. Our mazes are moveable and easily used in limited spaces. Tasks are performed with realistic and spontaneous though controlled exploratory movements. CONCLUSION: Our tasks enabled highlighting the use of different strategies. In a clinical perspective, considering the use of compensatory strategies should orient towards adapted behavioural rehabilitation.
Resumo:
OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.
Resumo:
Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity aortic valve and mitral ring implantation.
Resumo:
The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.
Resumo:
Given their central role in mercury (Hg) excretion and suitability as reservoirs, bird feathers are useful Hg biomonitors. Nevertheless, the interpretation of Hg concentrations is still questioned as a result of a poor knowledge of feather physiology and mechanisms affecting Hg deposition. Given the constraints of feather availability to ecotoxicological studies, we tested the effect of intra-individual differences in Hg concentrations according to feather type (body vs. flight feathers), position in the wing and size (mass and length) in order to understand how these factors could affect Hg estimates. We measured Hg concentration of 154 feathers from 28 un-moulted barn owls (Tyto alba), collected dead on roadsides. Median Hg concentration was 0.45 (0.076-4.5) mg kg(-1) in body feathers, 0.44 (0.040-4.9) mg kg(-1) in primary and 0.60 (0.042-4.7) mg kg(-1) in secondary feathers, and we found a poor effect of feather type on intra-individual Hg levels. We also found a negative effect of wing feather mass on Hg concentration but not of feather length and of its position in the wing. We hypothesize that differences in feather growth rate may be the main driver of between-feather differences in Hg concentrations, which can have implications in the interpretation of Hg concentrations in feathers. Finally, we recommend that, whenever possible, several feathers from the same individual should be analysed. The five innermost primaries have lowest mean deviations to both between-feather and intra-individual mean Hg concentration and thus should be selected under restrictive sampling scenarios.
Resumo:
In order to broaden our knowledge and understanding of the decision steps in the criminal investigation process, we started by evaluating the decision to analyse a trace and the factors involved in this decision step. This decision step is embedded in the complete criminal investigation process, involving multiple decision and triaging steps. Considering robbery cases occurring in a geographic region during a 2-year-period, we have studied the factors influencing the decision to submit biological traces, directly sampled on the scene of the robbery or on collected objects, for analysis. The factors were categorised into five knowledge dimensions: strategic, immediate, physical, criminal and utility and decision tree analysis was carried out. Factors in each category played a role in the decision to analyse a biological trace. Interestingly, factors involving information available prior to the analysis are of importance, such as the fact that a positive result (a profile suitable for comparison) is already available in the case, or that a suspect has been identified through traditional police work before analysis. One factor that was taken into account, but was not significant, is the matrix of the trace. Hence, the decision to analyse a trace is not influenced by this variable. The decision to analyse a trace first is very complex and many of the tested variables were taken into account. The decisions are often made on a case-by-case basis.
Dial M for Murder: A Case of Passion Killing, Criminal Evidence and Sultanic Power in Medieval India
Resumo:
This paper considers the structures and applications of the criminal judicial system in the Islamic Later Middle Period as it developed in India under the sultans of Delhi (1200-1400 CE). A fundamental issue in crime and punishment is the relationship between sultanic power and religious authority. Particularly at stake in this relationship is the question of who can sanction the highest form of punishment, i.e. the death penalty (siyāsa). Contemporary historians and scholars in the study of religion investigating the relationship between sharīʿa and siyāsa to reveal the extent and limits of sultanic power show a system of governance that allowed for the delegation of authority, particularly in the area of the judiciary, from the sultan down to viziers and judges. Some scholars depict the relationship between the ʿulamāʾ and the sultan as a kind of stand off. The actual dynamics of legal jurisdiction were much more complex. This study proposes a new interpretive framework for understanding the relationship between political power and religious authority through a critical analysis of the criminal judicial system, law, and historical narrative. In particular, I consider a murder case described by Shams al-dīn Sirāj ʿAfīf in one of the most significant histories written in the later Delhi Sultanate, the Tārīkh-i Fīrūzshāhī.