401 resultados para Complication


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Perineal stapled prolapse (PSP) resection is a novel operation for treating external rectal prolapse. However, no long-term results have been reported in the literature. This study analyses the long-term recurrence rate, functional outcome, and morbidity associated with PSP resection. METHODS: Nine consecutive patients undergoing PSP resection between 2007 and 2011 were prospectively followed. Surgery was performed by the same surgeons in a standardised technique. Recurrence rate, functional outcome, and complication grade were prospectively assessed. RESULTS: All 9 patients undergoing PSP resection were investigated. The median age was 72 years (range 25-88 years). No intraoperative complications occurred. Faecal incontinence, preoperatively present in 2 patients, worsened postoperatively in one patient (Vaizey 18-22). One patient developed new-onset faecal incontinence (Vaizey 18). The median obstructive defecation syndrome score decreased postoperatively significantly from 11 (median; range 8-13) to 5 (median; range 4-8) (p < 0.005). At a median follow-up of 40 months (range 14-58 months), the prolapse recurrence rate was 44 % (4/9 patients). CONCLUSIONS: The PSP resection is a fast and safe procedure associated with low morbidity. However, the poor long-term functional outcome and the recurrence rate of 44 % warrant a cautious patient selection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bilioma is a rare complication of traumatic liver injury, and the precise site of bile leak is often difficult to demonstrate with a non-invasive technique. We report a case of post-traumatic bile leak in a 15-year-old girl in whom spiral CT after intravenous cholangiography allowed excellent preoperative demonstration of the extent of the liver rupture and an exact location of the bile leak. We think that spiral-CT cholangiography could be an accurate, non-invasive technique to investigate the biliary system in cases of paediatric liver trauma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractBreast cancer is one of the most common cancers affecting one in eight women during their lives. Survival rates have increased steadily thanks to early diagnosis with mammography screening and more efficient treatment strategies. Post-operative radiation therapy is a standard of care in the management of breast cancer and has been shown to reduce efficiently both local recurrence rate and breast cancer mortality. Radiation therapy is however associated with some late effects for long-term survivors. Radiation-induced secondary cancer is a relatively rare but severe late effect of radiation therapy. Currently, radiotherapy plans are essentially optimized to maximize tumor control and minimize late deterministic effects (tissue reactions) that are mainly associated with high doses (» 1 Gy). With improved cure rates and new radiation therapy technologies, it is also important to evaluate and minimize secondary cancer risks for different treatment techniques. This is a particularly challenging task due to the large uncertainties in the dose-response relationship.In contrast with late deterministic effects, secondary cancers may be associated with much lower doses and therefore out-of-field doses (also called peripheral doses) that are typically inferior to 1 Gy need to be determined accurately. Out-of-field doses result from patient scatter and head scatter from the treatment unit. These doses are particularly challenging to compute and we characterized it by Monte Carlo (MC) calculation. A detailed MC model of the Siemens Primus linear accelerator has been thoroughly validated with measurements. We investigated the accuracy of such a model for retrospective dosimetry in epidemiological studies on secondary cancers. Considering that patients in such large studies could be treated on a variety of machines, we assessed the uncertainty in reconstructed peripheral dose due to the variability of peripheral dose among various linac geometries. For large open fields (> 10x10 cm2), the uncertainty would be less than 50%, but for small fields and wedged fields the uncertainty in reconstructed dose could rise up to a factor of 10. It was concluded that such a model could be used for conventional treatments using large open fields only.The MC model of the Siemens Primus linac was then used to compare out-of-field doses for different treatment techniques in a female whole-body CT-based phantom. Current techniques such as conformai wedged-based radiotherapy and hybrid IMRT were investigated and compared to older two-dimensional radiotherapy techniques. MC doses were also compared to those of a commercial Treatment Planning System (TPS). While the TPS is routinely used to determine the dose to the contralateral breast and the ipsilateral lung which are mostly out of the treatment fields, we have shown that these doses may be highly inaccurate depending on the treatment technique investigated. MC shows that hybrid IMRT is dosimetrically similar to three-dimensional wedge-based radiotherapy within the field, but offers substantially reduced doses to out-of-field healthy organs.Finally, many different approaches to risk estimations extracted from the literature were applied to the calculated MC dose distribution. Absolute risks varied substantially as did the ratio of risk between two treatment techniques, reflecting the large uncertainties involved with current risk models. Despite all these uncertainties, the hybrid IMRT investigated resulted in systematically lower cancer risks than any of the other treatment techniques. More epidemiological studies with accurate dosimetry are required in the future to construct robust risk models. In the meantime, any treatment strategy that reduces out-of-field doses to healthy organs should be investigated. Electron radiotherapy might offer interesting possibilities with this regard.RésuméLe cancer du sein affecte une femme sur huit au cours de sa vie. Grâce au dépistage précoce et à des thérapies de plus en plus efficaces, le taux de guérison a augmenté au cours du temps. La radiothérapie postopératoire joue un rôle important dans le traitement du cancer du sein en réduisant le taux de récidive et la mortalité. Malheureusement, la radiothérapie peut aussi induire des toxicités tardives chez les patients guéris. En particulier, les cancers secondaires radio-induits sont une complication rare mais sévère de la radiothérapie. En routine clinique, les plans de radiothérapie sont essentiellement optimisées pour un contrôle local le plus élevé possible tout en minimisant les réactions tissulaires tardives qui sont essentiellement associées avec des hautes doses (» 1 Gy). Toutefois, avec l'introduction de différentes nouvelles techniques et avec l'augmentation des taux de survie, il devient impératif d'évaluer et de minimiser les risques de cancer secondaire pour différentes techniques de traitement. Une telle évaluation du risque est une tâche ardue étant donné les nombreuses incertitudes liées à la relation dose-risque.Contrairement aux effets tissulaires, les cancers secondaires peuvent aussi être induits par des basses doses dans des organes qui se trouvent hors des champs d'irradiation. Ces organes reçoivent des doses périphériques typiquement inférieures à 1 Gy qui résultent du diffusé du patient et du diffusé de l'accélérateur. Ces doses sont difficiles à calculer précisément, mais les algorithmes Monte Carlo (MC) permettent de les estimer avec une bonne précision. Un modèle MC détaillé de l'accélérateur Primus de Siemens a été élaboré et validé avec des mesures. La précision de ce modèle a également été déterminée pour la reconstruction de dose en épidémiologie. Si on considère que les patients inclus dans de larges cohortes sont traités sur une variété de machines, l'incertitude dans la reconstruction de dose périphérique a été étudiée en fonction de la variabilité de la dose périphérique pour différents types d'accélérateurs. Pour de grands champs (> 10x10 cm ), l'incertitude est inférieure à 50%, mais pour de petits champs et des champs filtrés, l'incertitude de la dose peut monter jusqu'à un facteur 10. En conclusion, un tel modèle ne peut être utilisé que pour les traitements conventionnels utilisant des grands champs.Le modèle MC de l'accélérateur Primus a été utilisé ensuite pour déterminer la dose périphérique pour différentes techniques dans un fantôme corps entier basé sur des coupes CT d'une patiente. Les techniques actuelles utilisant des champs filtrés ou encore l'IMRT hybride ont été étudiées et comparées par rapport aux techniques plus anciennes. Les doses calculées par MC ont été comparées à celles obtenues d'un logiciel de planification commercial (TPS). Alors que le TPS est utilisé en routine pour déterminer la dose au sein contralatéral et au poumon ipsilatéral qui sont principalement hors des faisceaux, nous avons montré que ces doses peuvent être plus ou moins précises selon la technTque étudiée. Les calculs MC montrent que la technique IMRT est dosimétriquement équivalente à celle basée sur des champs filtrés à l'intérieur des champs de traitement, mais offre une réduction importante de la dose aux organes périphériques.Finalement différents modèles de risque ont été étudiés sur la base des distributions de dose calculées par MC. Les risques absolus et le rapport des risques entre deux techniques de traitement varient grandement, ce qui reflète les grandes incertitudes liées aux différents modèles de risque. Malgré ces incertitudes, on a pu montrer que la technique IMRT offrait une réduction du risque systématique par rapport aux autres techniques. En attendant des données épidémiologiques supplémentaires sur la relation dose-risque, toute technique offrant une réduction des doses périphériques aux organes sains mérite d'être étudiée. La radiothérapie avec des électrons offre à ce titre des possibilités intéressantes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fibrin sealing has recently evolved as a new technique for mesh fixation in endoscopic inguinal hernia repair. A comprehensive Medline search was carried out evaluating fibrin sealant for mesh fixation, and finally 12 studies were included (3 randomized trials, 3 nonrandomized trials, and 6 case series). The trials were assessed for operative time, seroma formation, recovery time, recurrence rate, and acute and chronic pain.There was a trend toward decreased operative times for fibrin sealing compared with mechanical stapling; however, the results for seroma formation remained contradictory. The most important finding was the reduced postoperative pain. Recovery times were lower after fibrin sealing and the recurrence rates showed no differences.Fibrin sealing for mesh fixation in the endoscopic inguinal hernia surgery is a promising alternative to mechanical stapling, which can be safely applied. As the overall quality of published data remains poor, further well-designed studies are needed until fibrin sealing can replace mechanical stapling as a new standard for mesh fixation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the role of vitreoretinal surgery in maximizing treatment outcome following complications after proton therapy for uveal melanoma and to evaluate its safety. METHODS: Retrospective chart study on 21 patients (2% of a total of 1,005 treated by proton therapy between January 2003 and August 2007) who had developed a complication requiring vitreoretinal surgery. Mean/median total follow-up after irradiation was 43/43 months (range, 12-70 months). RESULTS: Indications for surgery included vitreous hemorrhage (n = 13), epimacular membrane (n = 5), rhegmatogenous retinal detachment (n = 1), combined vitreous hemorrhage with total serous retinal detachment (n = 1), and vitritis (n = 1). Mean/median interval for vitreoretinal surgery after irradiation was 21/20 months (range, 4-45 months), and mean/median follow-up after pars plana vitrectomy was 22/23 months (range, 2-56 months). Pars plana vitrectomy was combined with retinal photocoagulation (n = 5), air/gas (n = 5), or silicone oil tamponade (n = 1). Mean Snellen visual acuity was 20/200 (0-20/40) before and 20/100 (0-20/25) after pars plana vitrectomy. A transient postoperative rise in intraocular pressure was measured in seven patients. Four patients developed phthisis bulbi. CONCLUSION: Vitreoretinal surgery was efficient in maximizing treatment outcome after proton therapy, as it allowed a better oncologic follow-up. Pars plana vitrectomy permitted panretinal photocoagulation to avoid neovascular glaucoma or retinal detachment repair. Macular surgery improved visual acuity, especially in anterior melanoma, whereas repeated surgery may increase the risk of enucleation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM OF THE PAPER: Arouse the reflection with a fiction having a scientific appearance, presenting a late and unexpected complication of the universal inactivation of pathogens. CONCLUSION: Such a fiction story opens the debate on a series of fundamental questions that could be addressed during the paradigm shift that is expected by introducing universal pathogen inactivation of blood products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Summary: Intestinal pseudo-obstruction is a rare complication resulting from a variety of disorders. Symptoms include abdominal pain, nausea, vomiting, diarrhea, constipation, and malnutrition. Vincristine-related pseudo-obstruction has been reported in the literature, but its description in children and recommendations for management are lacking. A review of the literature revealed 21 reported pediatric cases of vincristine-related pseudo-obstruction. Most have, however, been attributed to a drug interaction with itraconazole, accidental vincristine overdose, or liver failure. Potential genetic causes are rarely addressed. We present here 5 cases of pseudo-obstruction related to vincristine without any identifiable predisposing factors, and a suggested algorithm for management

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Gastric banding is currently one of the most performed procedures for morbid obesity. Results are related in part to the surgical technique and the quality of follow-up. Several bands are currently on the market, and it may bethat the type of band also plays a role in long-term results. The aim of this prospective randomized study was to compare the long-term results of the Lapband and the SAGB.Patients and methods: In three institutions with a common bariatric surgeon, consecutive patients undergoing laparoscopic gastric banding for morbid obesity were randomized to receive either a Lapband or a SAGB. The Lapband was placed using the perigastric and the SAGB with the pars flaccida technique. All data were collected prospectively. The median duration of follow-up was 131 months (103-147). Patients who lost their band were excluded from analysis as of band removal.Results: 180 patients were included between December 1998 and June 2002, 90 in each group. Except for age, which was lower in SAGB patients, the pre-operative characteristics were similar in the two patient groups. Early band-related morbidity was higher in the SAGB group (6,6 vs 0 %, p=0,03). Patients with a Lapband lost weight quicker than those with SAGB (EBMIL 50,8 vs 39,8 after 12 months, p<0,001), but the two weight loss curves joined after 24 months, and no difference could be observed later on up to 12 years after surgery (EBMIL 53,7 vs 58,1 % after 10 years, P=0,68). Long-term complications developed in 91 patients (50,5 %). Severe complications leading to band removal±conversion to another procedure developed in 30 and 40 patients in the Lapband and SAGB group respectively (33,3 vs 44,4 %, p=0,16).Conclusions: This prospective randomized study shows no significant difference in the long-term results of gastric banding between the Lapband and the SAGB. Both bands were associated with significant long-term complication and band removal/conversion rates. Patients who retain their band have acceptable long-term weight loss. It is likely that the concept of gastric banding rather than the device itself plays the most important role in longterm results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The value of adenovirus plasma DNA detection as an indicator for adenovirus disease is unknown in the context of T cell-replete hematopoietic cell transplantation, of which adenovirus disease is an uncommon but serious complication. METHODS: Three groups of 62 T cell-replete hematopoietic cell transplant recipients were selected and tested for adenovirus in plasma by polymerase chain reaction. RESULTS: Adenovirus was detected in 21 (87.5%) of 24 patients with proven adenovirus disease (group 1), in 4 (21%) of 19 patients who shed adenovirus (group 2), and in 1 (10.5%) of 19 uninfected control patients. The maximum viral load was significantly higher in group 1 (median maximum viral load, 6.3x10(6) copies/mL; range, 0 to 1.0x10(9) copies/mL) than in group 2 (median maximum viral load, 0 copies/mL; range, 0 to 1.7x10(8) copies/mL; P<.001) and in group 3 (median maximum viral load, 0 copies/mL; range 0-40 copies/mL; P<.001). All patients in group 2 who developed adenoviremia had symptoms compatible with adenovirus disease (i.e., possible disease). A minimal plasma viral load of 10(3) copies/mL was detected in all patients with proven or possible disease. Adenoviremia was detectable at a median of 19.5 days (range, 8-48 days) and 24 days (range, 9-41 days) before death for patients with proven and possible adenovirus disease, respectively. CONCLUSION: Sustained or high-level adenoviremia appears to be a specific and sensitive indicator of adenovirus disease after T cell-replete hematopoietic cell transplantation. In the context of low prevalence of adenovirus disease, the use of polymerase chain reaction of plasma specimens to detect virus might be a valuable tool to identify and treat patients at risk for viral invasive disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hypoglycemia is a potentially serious complication of insulin therapy. Some insulin-dependent diabetic patients can benefit from continuous subcutaneous insulin infusion therapy (an "insulin pump"), which in most case improves glycemia control and decreases the occurrence of hypoglycemic episodes. However, such events may occur, particularly during initial treatment phases or pregnancy. Severe hypoglycemia is mainly managed by stopping the insulin pump and insuring an adequate carbohydrate intake. Patients with insulin pumps and their entourage should receive specific instruction in the adjustment of pump flow in the presence of dysglycemia-inducing circumstances (illness, physical exertion), as well as in anticipation of high-risk situations, such as motor-vehicle driving.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cerebral aneurysms and arteriovenous malformations (AVMs) are well-known sources of intracranial hemorrhage, but can also manifest as other clinical symptoms or remain clinically asymptomatic. The aim was to document and analyze cases of aneurysm or AVM with brain infarction. Survey on 4804 stroke patients treated at the Department of Neurology, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland between 1978 and 2000 using the Lausanne Stroke Registry. Twenty patients presented with cerebral aneurysm and 21 with cerebral AVM. Hemorrhage was present in 100% of the AVM and in 75% of the aneurysm patients; in one (5%) of the remaining aneurysm patients, aneurysm and infarction were located in different territories. Infarction associated with Sylvian artery aneurysm was found in three (15%), vertebrobasilar ischemia because of fusiform left vertebral artery aneurysm in one (5%), and dural fistula draining to the distal transversal and left sigmoid sinus associated with a stroke in the territory of the left anterior inferior cerebellar artery in one patient. Ischemic stroke is infrequent, but important, complication in unruptured intracranial aneurysms and AVMs. The early recognition and therapy of these vascular malformations in selected patients can avoid a major neurological deficit or death caused by their rupture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND & AIMS: The study was designed to investigate and quantify nutritional support, and particularly enteral nutrition (EN), in critically ill patients with severe hemodynamic failure. METHODS: Prospective, descriptive study in a surgical intensive care unit (ICU) in a university teaching hospital: patients aged 67+/-13 yrs (mean+/-SD) admitted after cardiac surgery with extracorporeal circulation, staying 5 days in the ICU with acute cardiovascular failure. Severity of disease was assessed with SAPS II, and SOFA scores. Variables were energy delivery and balance, nutrition route, vasopressor doses, and infectious complications. Artificial feeding delivered according to ICU protocol. EN was considered from day 2-3. Energy target was set 25 kcal/kg/day to be reached stepwise over 5 days. RESULTS: Seventy out of 1114 consecutive patients were studied, aged 67+/-17 years, and staying 10+/-7 days in the ICU. Median SAPS II was 43. Nine patients died (13%). All patients had circulatory failure: 18 patients required intra-aortic balloon-pump support (IABP). Norepinephrine was required in 58 patients (83%). Forty patients required artificial nutrition. Energy delivery was very variable. There was no abdominal complication related to EN. As a mean, 1360+/-620 kcal/kg/day could be delivered enterally during the first 2 weeks, corresponding to 70+/-35% of energy target. Enteral nutrient delivery was negatively influenced by increasing dopamine and norepinephrine doses, but not by the use of IABP. CONCLUSION: EN is possible in the majority of patients with severe hemodynamic failure, but usually results in hypocaloric feeding. EN should be considered in patients with careful abdominal and energy monitoring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RAPPORT DE SYNTHESEBUTLe but de cette étude est de suivre prospectivement les résultats d'une sclérectomie profonde (SP) modifiée en utilisant le tube Ex-PRJESS LR-50, associée à une phacoémulsification avec implantation d'une lentille intraoculaire (LIO), dans la chirurgie combinée du glaucome et de la cataracte.METHODENous avons inclus dans l'étude 24 yeux de 24 patients présentant un glaucome médicalement non contrôlé et une cataracte justifiant son ablation.Une phacoémulsification avec implantation d'une LIO est effectuée. Puis le tube Ex-PRESS LR-50 est inséré au niveau du canal de Schlemm, dans la chambre antérieure, sous un volet scléral. Une SP postérieure partielle est ensuite pratiquée afin de créer une bulle de filtration intrasclérale.Le taux de succès complet a été défini par une pression intraoculaire (PIO) <18 mmHg sans traitement et le taux de succès relatif par une PIO <18 mmHg avec ou sans traitement. En cas de fibrose ou de kyste de la bulle de filtration, une injection sous-conjonctivale d'une solution de Mitomycin C à 0.02% est réalisée, avec ou sans needling.RESULTATSLe suivi moyen était de 40.1±10.8 [moyenne±DS] mois. En préopératoire, la PIO se situait à 18.1 ±5.3 mmHg; la meilleure acuité visuelle corrigée (MAVC) était mesurée à 0.6±0.3 (échelle de Snellen) et le nombre de médicaments hypotenseurs oculaires était de 2.3±1.1. La PIO a diminué de 25.4% à 24 mois et de 27.0% à 48 mois. A 24 mois, 19 patients (86.3%) avaient une MAVC supérieure ou égal à 0.5, et à 48 mois la MAVC était mesurée à 0.7±0.3. Lors de la dernière visite, le nombre moyen de médicaments se situait à 0.6±0.8 (p<0.05). Des injections sous conjonctivales d'une solution de Mitomycin C à 0.02% ont été nécessaires dans 5 yeux. Aucune érosion conjonctivale n'a été constatée. Deux complications majeures ont été observées. Une endophtalmie, deux jours après l'intervention chirurgicale avec phtisis secondaire du globe oculaire. Une obstruction du tube Ex-PRESS LR-50 par de la fibrine, ayant justifié son ablation avec SP classique en un autre site.CONCLUSIONLe tube Ex-PRESS LR-50 inséré dans la chambre antérieure avec une SP modifiée réduit efficacement la PIO dans la chirurgie combinée du glaucome et prévient l'érosion conjonctivale, une complication importante lorsque l'implant n'est pas couvert par un volet scléral.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUME L'infiltration tissulaire par les cellules leucémiques, responsable de leucostase, est une complication grave de la leucémie aiguë hyperleucocytaire. Elle peut entraîner une détresse respiratoire et des troubles neurologiques de mauvais pronostic. Pendant longtemps, la prolifération intravasculaire des cellules leucémiques et l'augmentation de la viscosité étaient considérées comme en étant responsables, et le traitement reposait sur une cytoréduction rapide par leucaphérèse. Actuellement, l'interaction entre les cellules leucémiques et l'endothélium vasculaire est plutôt considérée comme la cause de ce phénomène. En effet, les cellules leucémiques peuvent induire l'expression des sélectives endothéliales. Les sélectives initient le roulement des leucocytes avant leur adhésion ferme et leur migration dans les tissus. Elles reconnaissent des ligands spécifiques exprimés à la surface des leucocytes, comme PSGL-1 qui est un ligand commun des sélectives. Cependant, plusieurs études suggèrent que d'autres ligands de la E-sélective soient exprimés par les leucocytes. L'interaction des cellules leucémiques avec la E- et la P- sélective est corrélée avec l'expression de la molécule CLA, reconnue par l'anticorps HECA-452. L'immunopurification des ligands de la E-sélective avec cet anticorps a permis d'isoler, des cellules THP1 et U937, une protéine de 170 kDa, ainsi qu'une autre protéine de 250 kDa des cellules U937, en plus de PSGL-1. Ces protéines ont également été purifiées avec la protéine de fusion Esélective/IgM. CD43 et CD44 semblent être des ligands de la E-sélective sur certaines lignées, mais leur interaction avec la E-sélective n'est pas toujours retrouvée. De plus, cette étude a permis de montrer que ces ligands de la E-sélectiné sont exprimés dans les rafts lipidiques, comme PSGL-1 et la L-sélective des neutrophiles. Ces deux nouveaux ligands sont en cours d'identification. Ils pourraient représenter une nouvelle cible dans le traitement de la leucostase, mais aussi lors d'inflammation chronique ou de métastases. ABSTRACT Leukostasis is alife-threatening complication of acute leukemia, that results from tissue infiltration of leukemic blasts that migrate out of blood flow and interfere with normal tissue functions. The process leading to these complications has been attributed to the overcrowding of leukemic cells in the microcirculation. However, leukostasis more likely results from the adhesive interactions between leukemic blasts and the endothelium. Activated endothelium express adhesion molecules like P- and E-selectin, and leukemic cells themselves can induce the expression of E-selectin on endothelial cells. Selectins are essential in initiating the rolling of intravascular cells on endothelium before firm adhesion and transmigration outside of blood vessels. They interact with specific ligands on leukocyte cell surface. P-selectin glycoprotein ligand-1 (PSGL-1) is common ligand for E-, P- and L-selectin. Recently, CD44, ESL-1 and CD44 were shown to cooperate. ìn supporting mouse neutrophil adhesion to E-selectin. Other E-selectin ligands remain to be identified in humans. Leukemic cells were screened in order to characterize human E-selectin ligands. The interactions of E- and P-selectin correlate with the expression of CLA epitope. Therefore, HECA-452 mAb that recognizes CLA was used for immunopurification. Aglycoprotein of 170 kDa was purified from THP1 and U937 cells, and a protein of 250 kDa from U937 cells. These proteins were also purified by affinity binding to E-selectin/IgM chimera. PSGL-1 bound to E-selectin as expected, but CD43 and CD44 were not always adsorbed on E-selectin chimera, depending on cell types. E-selectin ligands were also shown to be in lipid rafts in leukemic cells, like PSGL-1 and L-selectin in human neutrophils. The 170 kDa protein has been sequenced, and three interesting ligands were among the candidates: ESL-1, CD44 and podocalyxin. These ligands are under investigation, and may represent a new therapeutic target in leukostasis, inflammation or cancer metastasis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Acute renal failure is a serious complication in critically ill patients and frequently requires renal replacement therapy, which alters trace element and vitamin metabolism. OBJECTIVE: The objective was to study trace element balances during continuous renal replacement therapy (CRRT) in intensive care patients. DESIGN: In a prospective randomized crossover trial, patients with acute renal failure received CRRT with either sodium bicarbonate (Bic) or sodium lactate (Lac) as a buffering agent over 2 consecutive 24-h periods. Copper, selenium, zinc, and thiamine were measured with highly sensitive analytic methods in plasma, replacement solutions, and effluent during 8-h periods. Balances were calculated as the difference between fluids administered and effluent losses and were compared with the recommended intakes (RI) from parenteral nutrition. RESULTS: Nineteen sessions were conducted in 11 patients aged 65 +/- 10 y. Baseline plasma concentrations of copper were normal, whereas those of selenium and zinc were below reference ranges; glutathione peroxidase was in the lower range of normal. The replacement solutions contained no detectable copper, 0.01 micromol Se/L (Bic and Lac), and 1.42 (Bic) and 0.85 (Lac) micromol Zn/L. Micronutrients were detectable in all effluents, and losses were stable in each patient; no significant differences were found between the Bic and Lac groups. The 24-h balances were negative for selenium (-0.97 micromol, or 2 times the daily RI), copper (-6.54 micromol, or 0.3 times the daily RI), and thiamine (-4.12 mg, or 1.5 times the RI) and modestly positive for zinc (20.7 micromol, or 0.2 times the RI). CONCLUSIONS: CRRT results in significant losses and negative balances of selenium, copper, and thiamine, which contribute to low plasma concentrations. Prolonged CRRT is likely to result in selenium and thiamine depletion despite supplementation at recommended amounts.