115 resultados para Cavità Laser Fabry-Perot FEA Rumori Simulazione


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silver has been demonstrated to be a powerful cationization agent in mass spectrometry (MS) for various olefinic species such as cholesterol and fatty acids. This work explores the utility of metallic silver sputtering on tissue sections for high resolution imaging mass spectrometry (IMS) of olefins by laser desorption ionization (LDI). For this purpose, sputtered silver coating thickness was optimized on an assorted selection of mouse and rat tissues including brain, kidney, liver, and testis. For mouse brain tissue section, the thickness was adjusted to 23 ± 2 nm of silver to prevent ion suppression effects associated with a higher cholesterol and lipid content. On all other tissues, a thickness of at 16 ± 2 nm provided the best desorption/ionization efficiency. Characterization of the species by MS/MS showed a wide variety of olefinic compounds allowing the IMS of different lipid classes including cholesterol, arachidonic acid, docosahexaenoic acid, and triacylglyceride 52:3. A range of spatial resolutions for IMS were investigated from 150 μm down to the high resolution cellular range at 5 μm. The applicability of direct on-tissue silver sputtering to LDI-IMS of cholesterol and other olefinic compounds presents a novel approach to improve the amount of information that can be obtained from tissue sections. This IMS strategy is thus of interest for providing new biological insights on the role of cholesterol and other olefins in physiological pathways or disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Fabry disease is an X-linked genetic disorder due to deficiency of the lysosomal enzyme a-galactosidase A, which leads to the accumulation of neutral glycosphingolipids within the lysosomes of almost all tissues. Clinical manifestations usually include acroparaesthesia, renal insufficiency and cardiomyopathy. Recently, pulmonary manifestations consisting of progressive obstructive airway disease have been reported. The aim of this study was to analyse the cross-sectional prevalence of airflow obstruction in a Swiss cohort of patients, and in selected cases, to evaluate the impact of enzyme replacement therapy (ERT) with agalsidase alfa (ReplagalTM; TKT - 5S). Methods: Forty-four patients (27 men, 17 women) were included in the study and received pulmonary function testing. Fifteen patients underwent spirometry after ERT. Results: Twelve patients (nine men) had chronic obstructive pulmonary disease according to the Global Obstructive Lung Disease (GOLD) initiative criteria: forced expiratory volume (FEV1)/forced vital capacity (FVC) 50.7), but only one was an active smoker and one a previous smoker. FEV1/ FVC as percentage predicted was weakly correlated with age (r=0.42, p=0.005, calculated by Pearson product-moment correlation), demonstrating that airway obstruction occurs in the late stages of the disease. Median FEV1 in patients with obstruction was 67% of predicted (range, 45-90%). Reversibility of FEV1 after b2-agonist inhalation never exceeded 8% of predicted. Diffusing capacity of the lung for carbon monoxide (DLCO) was measured in 13 individuals with a median of 88% of predicted (range, 39-125%). After 15+9 months of ERT, spirometry measurements were recorded in 15 patients. Decline in FEV1 was -2+5% of predicted. (p40.05, measured by the Wilcoxon signed-rank test). Median change in DLCO was -10% of predicted (-40 to +25%, p40.05). High resolution computed tomography scans demonstrated a moderate thickening of the bronchial wall in affected individuals, without evidence of emphysema. Conclusion: We conclude that Fabry disease can be complicated by significant airway obstruction, particularly in patients in the advanced stages of the disease, and that in the period studied, ERT had no demonstrable impact on pulmonary function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The graffiti on pottery discovered on the site of Aventicum (Avenches, VD/Switzerland) form the largest corpus of minor inscriptions of the Roman Empire studied until now. Indeed, a total of 1828 graffiti have been found. The reading and the recording of the inscriptions are generally dependent on the state of conservation of the graffito and its support. In numerous cases, only a pale shadow of the inscription is visible, which makes traditional observations, such as visual observations with the naked eye, unsuitable for its decipherment. Consequently, advanced techniques have been applied for enhancing the readability of such inscriptions. In our paper we show the efficiency of 3D laser profilometry as well as high resolution photography as powerful means to decipher illegible engraved inscriptions. The use of such analyses to decipher graffiti on pottery or on other materials enables a better understanding of minor inscriptions and improves the knowledge of the daily life of ancient populations substantially.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Problématique : La maladie de Fabry est une maladie métabolique à stockage lysosomal. C'est une maladie héreditaire à transmission récessive qui concerne l'enzyme alpha-Galactosidase A. Le gène de l'alpha-Galactosidase A (GLA) se trouve au niveau du bras long du chromosome X «carté en Xq21.33-Xq22 ». L'enzyme muté ne recouvre plus son rôle catabolisateur et il ne métabolise pas le substrat globotriaosylceramide (Gb3). Par conséquence le Gb3 s'accumule dans tous les tissus. Dans les parois des vaisseaux sanguins le Gb3 s'accumule dans l'endothelium, la tunique interne des vaisseaux sanguins. Ce déficit métabolique se traduit par l'épaississement de la paroi vasculaire, des processus d'infarctus et ischémies du tissu cardiaque, rénal et cérébral. L'implication cardiaque de la maladie de Fabry est décrite chez plus de 78% des patients affectés par la maladie et se manifeste par une hypertrophie cardiaque du ventricule gauche. Toutefois, il n'existe pas de relation étroite entre hypertrophie cardiaque et le Gb3. La sphingosine 1-phosphate à été identifiée dans notre laboratoire et proposée comme facteur de croissance à l'origine du remodelage cardiovasculaire. De plus, la Globotriaosylsphingosine (Lyso-Gb3) à été aussi proposée comme facteur vasoactif chez les patients Fabry. Objectif : L'identification d'un biomarqueur pour le diagnostic et le suivi thérapeutique de la maladie de Fabry représente une domaine d'investigation active en recherche scientifique. Le Gb3 plasmatique ou dans les urines, la biopsie rénale ou cardiaque qui est mis en évidence grâce à la microscopie électronique sous forme de corps concentrique lamellaires, constituent les biomarqueurs classiques de la maladie de Fabry. Dernièrement, le Lyso-Gb3 et le Sphingosine-1 phosphate (S1P) ont été proposés comme marqueurs du remodelage cardiovasculaire. Le but de ce travail est de rassembler et de discuter la littérature concernant ces nouveaux marqueurs et, d'étudier une possible interaction entre Lyso-Gb3 et le S1P. Méthodologie : Rassembler la littérature scientifique et analyser l'implication de ces marqueurs dans la maladie de Fabry et leur effets cardiovasculaires. De plus, un travail expérimental est effectué. Ce travail consiste en l'identification d'une relation possible entre le Lyso-Gb3 et le S1P. Résultats : Avec ce travail on a cherché à actualiser et mettre à jour les notions concernant les biomarqueurs qui prennent place dans cette pathologie et les connaissances qu'on possède à ce jour sur les manifestations cardiovasculaires et neurologiques.La recherche d'un biomarqueur prime par le fait qu'un nombre considerable de patients est sous-diagnostiqués pour la maladie de Fabry et que entre les taux de substrat enzymatique accumulé dans les tissus et l'hypertrophie cardiaque, on peut constater une discordance. Grâce à ce travail expérimental, on a exclue la possibilité d'un effet précurseur du lyso-Gb3 pour le S1P. Nous avons montré que le Lyso-Gb3 est reconnu par les récepteurs du S1P avec des effets commun pour les S1P1-3 et différents pour le S1P2. Les taux du Lyso-Gb3 et du S1P doivent être mesuré chez les patients Fabry et une stratégie thérapeutique doit prendre en compte le rapport S1P/Lyso-Gb3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enzyme replacement therapy has recently been introduced to treat Fabry disease, a rare X-linked lysosomal storage disorder. The disease occurs due to deficient activity of alpha-galactosidase A, leading to progressive accumulation of globotriaosylceramide in multiple organs and tissues. Renal, cardiac and cerebrovascular manifestations of the disease result in premature death in both hemizygous males and heterozygous females. This paper outlines the clinical signs, symptoms and diagnosis of Fabry disease, and the development of the two available enzyme replacement therapies -- agalsidase alfa and agalsidase beta. Agalsidase alfa and agalsidase beta are produced in a human cell line and in Chinese hamster ovary cells, respectively, resulting in products with the same amino acid sequence as the native human enzyme, but with different patterns of glycosylation. Correct post-translational glycosylation is important in terms of the pharmacokinetics, biodistribution, clinical efficacy and tolerability of genetically engineered protein therapeutics. Differences in glycosylation, which may affect immunogenicity and mannose-6-phosphate receptor-mediated cellular internalisation of administered enzyme, possibly account for the differences in dosing, clinical effects and safety profiles reported for agalsidase alfa and agalsidase beta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Deep burn assessment made by clinical evaluation has an accuracy varying between 60% and 80% and will determine if a burn injury will need tangential excision and skin grafting or if it will be able to heal spontaneously. Laser Doppler Imaging (LDI) techniques allow an improved burn depth assessment but their use is limited by the time-consuming image acquisition which may take up to 6 min per image. METHODS: To evaluate the effectiveness and reliability of a newly developed full-field LDI technology, 15 consecutive patients presenting with intermediate depth burns were assessed both clinically and by FluxExplorer LDI technology. Comparison between the two methods of assessment was carried out. RESULTS: Image acquisition was done within 6 s. FluxEXPLORER LDI technology achieved a significantly improved accuracy of burn depth assessment compared to the clinical judgement performed by board certified plastic and reconstructive surgeons (P < 0.05, 93% of correctly assessed burns injuries vs. 80% for clinical assessment). CONCLUSION: Technological improvements of LDI technology leading to a decreased image acquisition time and reliable burn depth assessment allow the routine use of such devices in the acute setting of burn care without interfering with the patient's treatment. Rapid and reliable LDI technology may assist clinicians in burn depth assessment and may limit the morbidity of burn patients through a minimization of the area of surgical debridement. Future technological improvements allowing the miniaturization of the device will further ease its clinical application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Theoretically myocardial angiogenesis of laser injury can be further enhanced by the addition of angiogenic growth factors. The influence of the way of administration of these factors on vascular growth around the channels is still unclear. MATERIALS AND METHODS: 18 pigs (mean weight 72 +/- 5.2 kg) were randomized to either triads of transmyocardial laser revascularization (TMLR) channels (group 1, n = 6) or isolated channels (group 2, n = 6), or a control group (n = 6). The animals had injections of bovine bone derived growth factor mixture either in the center of the triads in group 1 or within the channels themselves in group 2. Animals were sacrificed one month later for histological analysis. RESULTS: The vascular densities of myocardial areas within the triads of group 1 and around the channels in group 2 were significantly larger than in the control group: 15.2 +/- 3.7/mm2 and 14.2 +/- 3.5/mm2 respectively vs 5.3 +/- 1.6/mm2 (p < 0.001 for both differences). Differences of densities between group 1 and 2 were not statistically significant (p = 0.6). CONCLUSIONS: In this porcine model, the addition of a bovine bone derived growth factor mixture to TMLR significantly stimulates angiogenesis in the areas adjacent to the channels. The place of injection does not influence the angiogenesis intensity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: To evaluate outcomes after optimized laser in situ keratomileusis (LASIK) for astigmatism correction with flap created by a mechanical microkeratome or a femtosecond laser. Patients and Methods: In this retrospective study, a total of 102 eyes of 71 consecutive patients were enrolled undergoing optimized LASIK treatments using the Allegretto laser system (WaveLight Laser Technologie AG, Erlangen, Germany). A mechanical microkeratome for flap creation was used (One Use, Moria®) in 46 eyes (31 patients, spherical equivalent [SE] -4.44 D ± 2.4) and a femtosecond laser was used (LDV, Ziemer®) in 56 eyes (40 patients, spherical equivalent [SE] -3.07 D ± 3.3). The two groups were matched for inclusion criteria and were operated under similar conditions by the same surgeon. Results: Overall, the preoperative spherical equivalent was -9.5 diopters (D) to +3.37 D; the preoperative manifest astigmatism was between -1.5 D and -3.5 D. At 6 months postoperatively, the mean postoperative uncorrected distance visual acuity (UDVA) was 0.93 ± 0.17 (range 0.4 to 1.2) in the Moria group and 1.0 ± 0.21 (range 0.6 to 1.6) in the Femto group, which was statistically significant (p = 0.003). Comparing the cylinder power there was a statistical difference between the two groups (p = 0.0015). Conclusions: This study shows that the method of flap creation has a significant impact on postoperative astigmatism with a significantly better postoperative UDVA in the Femto group. These findings suggest that the femtosecond laser provides a better platform for LASIK treatment of astigmatism than the commonly used microkeratome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of line crossing sequences between rollerball pens and laser printers presents difficulties that may not be overcome using traditional techniques. This research aimed to study the potential of digital microscopy and 3-D laser profilometry to determine line crossing sequences between a toner and an aqueous ink line. Different paper types, rollerball pens, and writing pressure were tested. Correct opinions of the sequence were given for all case scenarios, using both techniques. When the toner was printed before the ink, a light reflection was observed in all crossing specimens, while this was never observed in the other sequence types. The 3-D laser profilometry, more time-consuming, presented the main advantage of providing quantitative results. The findings confirm the potential of the 3-D laser profilometry and demonstrate the efficiency of digital microscopy as a new technique for determining the sequence of line crossings involving rollerball pen ink and toner. With the mass marketing of laser printers and the popularity of rollerball pens, the determination of line crossing sequences between such instruments is encountered by forensic document examiners. This type of crossing presents difficulties with optical microscopic line crossing techniques involving ballpoint pens or gel pens and toner (1-4). Indeed, the rollerball's aqueous ink penetrates through the toner and is absorbed by the fibers of the paper, leaving the examiner with the impression that the toner is above the ink even when it is not (5). Novotny and Westwood (3) investigated the possibility of determining aqueous ink and toner crossing sequences by microscopic observation of the intersection before and after toner removal. A major disadvantage of their study resides in destruction of the sample by scraping off the toner line to see what was underneath. The aim of this research was to investigate the ways to overcome these difficulties through digital microscopy and three-dimensional (3-D) laser profilometry. The former was used as a technique for the determination of sequences between gel pen and toner printing strokes, but provided less conclusive results than that of an optical stereomicroscope (4). 3-D laser profilometry, which allows one to observe and measure the topography of a surface, has been the subject of a number of recent studies in this area. Berx and De Kinder (6) and Schirripa Spagnolo (7,8) have tested the application of laser profilometry to determine the sequence of intersections of several lines. The results obtained in these studies overcome disadvantages of other methods applied in this area, such as scanning electron microscope or the atomic force microscope. The main advantages of 3-D laser profilometry include the ease of implementation of the technique and its nondestructive nature, which does not require sample preparation (8-10). Moreover, the technique is reproducible and presents a high degree of freedom in the vertical axes (up to 1000 μm). However, when the paper surface presents a given roughness, if the pen impressions alter the paper with a depth similar to the roughness of medium, the results are not always conclusive (8). It becomes difficult in this case to distinguish which characteristics can be imputed to the pen impressions or the quality of the paper surface. This important limitation is assessed by testing different types of paper of variable quality (of different grammage and finishing) and the writing pressure. The authors will therefore assess the limits of 3-D laser profilometry technique and determine whether the method can overcome such constraints. Second, the authors will investigate the use of digital microscopy because it presents a number of advantages: it is efficient, user-friendly, and provides an objective evaluation and interpretation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Fabry disease is an X-linked disorder resulting from alpha-galactosidase A deficiency. The cardiovascular findings include left ventricular hypertrophy (LVH) and increased intima-media thickness of the common carotid artery (CCA IMT). The current study examined the possible correlation between these parameters. To corroborate these clinical findings in vitro, plasma from Fabry patients was tested for possible proliferative effect on rat vascular smooth muscle cells (vascular smooth muscle cell [VSMC]) and mouse neonatal cardiomyocytes. METHODS AND RESULTS: Thirty male and 38 female patients were enrolled. LVH was found in 60% of men and 39% of women. Increased CCA IMT was equally present in males and females. There was a strong positive correlation between LV mass and CCA IMT (r2=0.27; P<0.0001). VSMC and neonatal cardiomyocyte proliferative response in vitro correlated with CCA IMT (r2=0.39; P<0.0004) and LV mass index (r2=0.19; P=0.028), respectively. CONCLUSIONS: LVH and CCA IMT occur concomitantly in Fabry suggesting common pathogenesis. The underlying cause may be a circulating growth-promoting factor whose presence has been confirmed in vitro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND and OBJECTIVE: A non-touch laser-induced microdrilling procedure is studied on mouse zona pellucida (ZP). STUDY DESIGN/MATERIALS and METHODS: A 1.48-microns diode laser beam is focused in a 8-microns spot through a 45x objective of an inverted microscope. Mouse zygotes, suspended in a culture medium, are microdrilled by exposing their ZP to a short laser irradiation and allowed to develop in vitro. RESULTS: Various sharp-edged holes can be generated in the ZP with a single laser irradiation. Sizes can be varied by changing irradiation time (3-100 ms) or laser power (22-55 mW). Drilled zygotes present no signs of thermal damage under light and scanning electron microscopy and develop as expected in vitro, except for a distinct eight-shaped hatching behavior. CONCLUSION: The microdrilling procedure can generate standardized holes in mouse ZP, without any visible side effects. The hole formation can be explained by a local photothermolysis of the protein matrix.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Introduction : Les premières applications cliniques de la thérapie photodynamique (PDT) remontent à plus d'une vingtaine d'années. Basée sur l'activation d'un médicament photosensibilisateur par une source lumineuse à une longueur d'onde spécifique, la PDT permet la destruction sélective de tissus contenant le produit actif. Ce procédé a été expérimenté dans le traitement de cancers en raison de la propriété du médicament à se concentrer dans les tumeurs tout en épargnant les structures normales contigües. Cependant, les photosensibilisateurs utilisés jusqu'à ce jour n'ont pas démontré une accumulation exclusive dans les tissus néoplasiques mais également dans les structures saines avoisinantes induisant une destruction tissulaire non sélective. Notamment, d'importantes complications ont été rapportées suite à l'utilisation de la PDT dans la cavité thoracique après la résection de mésothéliomes pleuraux, et ce malgré l'arrivée de photosensibilisateurs de secondes générations. De ce fait, plusieurs études expérimentales ont été menées afin d'améliorer la sélectivité tumorale du médicament en modulant différentes conditions de traitement et en modifiant la structure du photosensibilisateur par pégylation. Le but de cette étude expérimentale est de corréler l'activité photodynamique, la phototoxicité et la distribution du m-tetrahydroxyphenylchlorin (mTHPC) et de sa forme pégylée, le PEG-mTHPC. De ce fait, un modèle de souris nues porteur de xenogreffes de mésothéliome humain a été utilisé pour étudier les deux photosensibilisateurs. De récents travaux avec ce modèle ont montré que la mesure de la concentration tissulaire du mTHPC et de sa forme pégylée par HPLC restait limitée afin de prédire l'activité photodynamique. De ce fait, nous pensons que les mesures de fluorescence peuvent être plus appropriée. Le signalement fluorescent est mesuré dans le tissu tumoral et dans une région contrôle de la peau afin d'étudier la distribution et l'intensité des deux sensibilisateurs. Méthode : Des souris nues (cd1nu/nu mice) de 8 semaines ont été transplantées avec des fragments de mésothéliome malin humain (H-meso-1). Ces derniers ont été obtenus à partir d'une suspension cellulaire. Au moins trois passages ont été faits dans les animaux, avant que le traitement soit initié. Deux groupes de 6 souris chacun ont été utilisés pour l'injection intraveineuse par la queue du mTHPC à 0.15 mg/kg et du PEG-mTHPC à dose équimolaire. Après trois jour, la tumeur ainsi qu'une région contrôle de la cuisse ont été illuminées sur une surface d'un diamètre de 1.2 cm et pendant 133 secondes avec un laser à une longueur d'onde à 652 nm (fluence 20 J/cm2, fluence rate 150 mW/cm2). Les animaux ont été ensuite sacrifiés 72 heures après l'illumination. L'étendue de la nécrose tumorale et de la région contrôle ont été déterminées en aveugle par histomorphometrie par un pathologue (HJA). La fluorescence microscopique a été évaluée dans 12 souris à une concentration de 0.15 et 0.5 mg/kg pour le mTHPC, et à doses équimolaires pour le PEG-mTHPC. Trois animaux ont été injectés avec le mTHPC à 0.15 mg/kg, 3 autres à dose équimolaire avec la forme pégylée et 6 souris avec le mTHPC à 0.5 mg/kg et à dose équimolaire. Les animaux ont été sacrifiés 72 heures après injection. L'intensité fluorescente des sensibilisateurs a été mesurée dans la tumeur et la région contrôle. Suite à cela, les coupes ont été fixées par H&E et superposées aux images fluorescentes, afin de localiser la distribution des deux photosensibilisateurs dans les différents compartiments tissulaires. Six souris transplantées n'ayant ni été injectées avec les sensibilisateurs ou illuminées ont servi de groupe contrôle. Résultats : Trois jours après l'illumination, la PDT provoque une nécrose tumorale de 10 ±5.4 mm2 pour le mTHPC à 0.15mg/kg et 5.2 ± 4.6 mm2 pour sa forme pégylée à dose équimolaire. Cependant, la nécrose tumorale induite par les deux formulations du sensibilisateur est significativement plus élevée que dans le groupe contrôle (0.33 ± 0.58 mm2) (P=0.02). Toutefois, le mTHPC pégylé provoque une photosensibilité cutanée moins importante que la forme non-pegylée. Dans les deux groupes, aucune nécrose n'a été observée dans la cuisse des animaux. Trois jours après l'injection du mTHPC et de la forme pégylée à 0.15 mg/kg, aucune activité fluorescente n'a été détectée. Cependant, à 0.5 mg/kg, la fluorescence microscopique révèle une distribution hétérogène des deux photo-sensibilisateurs dans le tissu tumoral avec une accumulation prédominante dans les régions peri-vasculaires. Les deux médicaments montrent une distribution intracellulaire homogène dans le cytoplasme et une absence de signalement dans le nucleus. La mesure de l'intensité fluorescente du mTHPC à 0.5mg/kg ne montre pas de différence significative entre le tissu tumoral et la région contrôle. Par contre, le PEG-mTHPC montre une intensité fluorescente supérieure dans le tissu tumoral que dans la peau (ratio tumeur- peau 0.94 pour le mTHPC et 1.73 pour le PEG-mTHPC). Conclusion : L'utilisation du mTHPC à 0.15mg/kg induit une nécrose tumorale similaire à celle du PEG-mTHPC à dose équimolaire. Cependant, ce dernier démontre une photo-toxicité plus atténuée de la peau. La fluorescence microscopique permet de localiser les deux sensibilisateurs dans les différents compartiments tissulaires à partir d'une dose de 0.5 mg/kg. Le PEG-mTHPC induit un signalement fluorescent supérieur dans le tissu tumoral par rapport à la peau. La mesure du signalement fluorescent a le potentiel de prédire l'activité photodynamique du mTHPC et de sa forme pégylée dans les xénogreffes de mésothéliome humain dans un modèle de souris nue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To study a new technic of laser treatment of macular holes. METHODS: 21 eyes with stage II-IV macular hole were treated with Argon-green laser. Pigment epithelium in the area of the hole was whitened with spots of 100-200 microns, 100-300 mW. We expected this treatment to create a cellular proliferation that could close and contract the hole. Follow-up after treatment ranged from 3 to 24 months (mean: 9.3 months). RESULTS: Within one month after treatment, the macular hole was closed in 7 eyes (33%) and partially closed in 5 eyes (24%). The visual acuity increased from 1 to 5 lignes (ETDRS chart) in 9 eyes (43%), it remained the same in 9 eyes (43%) and decreased from 1 to 2 lignes in 3 eyes (14%). CONCLUSION: Laser treatment of macular holes seems to be effective and could be proposed as an alternative to the patients who cannot be operated on by vitrectomy and gas tamponade.