164 resultados para Aortic ring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: : The systolic augmentation index (sAix), calculated from the central aortic pulse wave (reconstructed from the noninvasive recording of the radial pulse with applanation tonometry), is widely used as a simple index of central arterial stiffness, but has the disadvantage of also being influenced by the timing of the reflected with respect to the forward pressure wave, as shown by its inverse dependence on heart rate (HR). During diastole, the central aortic pulse also contains reflected waves, but their relationship to arterial stiffness and HR has not been studied. METHODS: : In 48 men and 45 women, all healthy, with ages ranging from 19 to 70 years, we measured pulse wave velocity (PWV, patients supine), a standard evaluator of arterial stiffness, and carried out radial applanation tonometry (patients sitting and supine). The impact of reflected waves on the diastolic part of the aortic pressure waveform was quantified in the form of a diastolic augmentation index (dAix). RESULTS: : Across ages, sexes, and body position, there was an inverse relationship between the sAix and the dAix. When PWV and HR were added as covariates to a prediction model including age, sex and body position as main factors, the sAix was directly related to PWV (P < 0.0001) and inversely to HR (P < 0.0001). With the same analysis, the dAix was inversely related to PWV (P < 0.0001) and independent of HR (P = 0.52). CONCLUSION: : The dAix has the same degree of linkage to arterial stiffness as the more conventional sAix, while being immune to the confounding effect of HR. The quantification of diastolic aortic pressure augmentation by reflected waves could be a useful adjunct to pulse wave analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME: L'objectif de cette étude était de déterminer l'impact de la grossesse non compliquée sur l'onde de pouls de la pression aortique centrale. Méthode 66 femmes au total avec une grossesse simple ont été réparties en trois groupes selon le stade de leur gestation: premier trimestre (T1, n=22), deuxième trimestre (T2, n=20) et troisième trimestre (T3, n=24). Le groupe contrôle (C, n=21) était constitué de femmes non enceintes, en bonne santé habituelle, prenant une contraception oestroprogestative. La tonométrie d'aplanation a été utilisée pour l'acquisition des ondes de pouls centrale un appareil disponible dans le commerce (SphygmoCor) permet l'enregistrement de l'onde de pouls périphérique avec un tonomètre d'aplanation de l'artère radiale au niveau du poignet, puis effectue sa transformation en sa forme centrale, grâce à une analyse de Fourrier et une fonction de transfert. L'influence des ondes réfléchies sur l'onde de pouls a été déterminée non seulement pendant la systole (augmentation systolique), comme on procède habituellement dans l'analyse de l'onde de pouls, mais aussi pendant la diastole (augmentation diastolique). Résultats Au cours de la grossesse, les pressions centrales systolique et diastolique sont restées inchangées et comparables aux valeurs mesurées chez les femmes qui ne sont pas enceintes. Dans le groupe contrôle, l'augmentation systolique s'élevait à 8.1±7.5% de la pression de pouls ; il n'y avait pas de différence statistiquement significative avec les valeurs obtenues chez les femmes enceintes, et ce, à n'importe quel stade de la grossesse (T1 : 4.6±11.4%, T2: 5.0±9.3%, T3 : 4.7±8.1%). Par contre, l'amplitude de l'augmentation diastolique diminuait avec la progression de la grossesse (C 6.5±2.4%, T1 : 5.2±3.1%, T2 : 3.8±2.6%; P=0.002 versus C; T3 : 2.3±2.0%; P<0.0001 versus C et P=0.004 versus T 1). Conclusion La grossesse ne modifie pas la forme de l'onde de pouls systolique centrale, ce qui implique de la part du système cardiovasculaire une adaptation fine à la demande croissante de flux sanguin, et ce, à tous les stades de la grossesse. Par contre, l'amplitude de l'onde de réflexion atteignant l'aorte pendant la diastole diminue progressivement au cours de la grossesse. Perspectives De récentes études montrent qu'une valeur anormalement haute de l'augmentation systolique de la pression centrale, comme on peut la déterminer avec la tonométrie d'aplanation, pourrait être un indice de trouble hypertensif de la grossesse débutant. Cette technique simple pourrait être d'autant plus facile à mettre en oeuvre si les valeurs normales pour l'augmentation systolique étaient indépendantes du stade de la grossesse, comme le suggèrent nos résultats, du moins pour les mesures prises en position assise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hybrid treatment of aortic aneurysms is indicated in patients having the ostia of supra aortic or visceral branches taken in to the aneurysm. Indeed, these lesions are not eligible for classic endovascular treatment because the existing endoprostheses cannot provide perfusion of the side branches without inducing major endoleaks. The surgical technique consists of 2 steps: firstly, a by-pass between normal aorta and the major aortic branches involved in the aneurysm is performed to guarantee the perfusion of the organs such as brain, bowel, and after endoprosthesis deployment. Secondly, the endoprosthesis is deployed using the classical technique to isolate the aneurysm. The hybrid approach provides safe and reliable treatment of complex aortic aneurysms with mortality and morbidity rate far below the classical open surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intra-aortic balloon pump (IABP) is the most frequently used mechanical circulatory support. Repeated trauma on the aortic wall has been reported as a cause of balloon perforation by endothelial denudation of atheromatous plaque. This study analyses the effect of IABP on the endothelium of the calf aorta. In 12 calves (mean weight: 72 +/- 6 kg) an IABP was inserted by femoral route and left during 6 hours on internal mode with a frequency of 80 cycles/min. The animals were sacrificed after the procedure (n = 4), at postoperative day (POD) 7 (n = 4), and at POD 14 (n = 4). In the aorta facing the balloon, nine transmural samples were taken proximally (n = 3), at mid height (n = 3) and distally (n = 3), for histological analysis of the percentage of aortic surface covered with endothelium. The percentage of aortic surface covered with endothelium at POD 0, 7 and 14 was proximally: 72.5 +/- 27.5%, 83.7 +/- 16.9% and 93.3 +/- 8.9% respectively; at mid-height: 50.8 +/- 30.7%, 65 +/- 25% and 95 +/- 5%; and distally: 31.4 +/- 20.1%, 48.3 +/- 34.4% and 85 +/- 10%. A large portion of the aortic endothelium is abraded after 6 hours of IAB pumping. This effect is more important at the distal level of the aorta. After two weeks, most of the endothelium has regenerated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Assess outcome of patients with descending thoracic aortic aneurysms complicated by aortobronchial and aortoesophageal fistulae in comparison to patients undergoing repair of aortic aneurysms without fistulae. METHODS: In a consecutive series of 145 patients (age 60 +/- 12 years) with repair of descending thoracic and thoracoabdominal aortic aneurysms, 11 patients (8%; age 63 +/- 9; NS) primarily presented for hematemesis and/or hemoptysis. In 8/11 patients (73%) an aortobronchial fistula was identified, and 3/11 patients (27%) suffered from an aortoesophageal fistula. Five of 11 patients (45%) had undergone previous aortic surgery in the same region. RESULTS: Extent of aortic segments (range 1-8) replaced was 3.1 +/- 1.4 for all versus 2.6 +/- 0.9 for fistulae (NS). Aortic cross clamp time was 38 +/- 22 min for all versus 45 +/- 15 min for fistulae (NS). Mortality at 30 days was 18/145 (12%) for all versus 16/134 (12%) without fistulae versus 2/11 (18%) with fistulae (NS). Paraparesis and or paraplegia was observed in 11/145 (8%) for all versus 10/134 (7%) without fistulae versus 1/11 (9%) for cases with fistulae (NS). Nine additional patients died after hospital discharge, seven without fistulae and two with fistulae (days 80, and 120) bringing the 1-year mortality up to 23/134 (17%) without fistulae versus 4/11 (36%) with fistulae (NS). Further analysis shows that the 1-year mortality accounts for 1/8 patients (13%) with aorto-bronchial fistulae versus to 3/3 patients (100%) with aorto-esophageal fistulae (esophageal versus bronchial fistula: P = 0.018; esophageal versus no fistula: P = 0.006). CONCLUSIONS: Outcome of patients suffering from descending thoracic aortic aneurysms complicated by aorto-bronchial fistulae can be similar to that without fistulae, whereas for cases complicated by aorto-esophageal fistulae the prognosis seems to remain poor even after successful hospital discharge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study evaluates sealing characteristics of two designs of endovascular grafts by angiographic demonstration of exclusion of porcine lumbar arteries. METHODS: 6 endovascular grafts (3 self-expandable with integrated polyurethane wall versus 3 nitinol structures covered with polyester fabric) were implanted in 6 porcine aortae. Perfusion of lumbar arteries was assessed by angiography after implantation and by angiography and dissection at graft explantation after 4 +/- 2 months. Tissue healing was evaluated by light and scanning electron microscopy. RESULTS: Immediate exclusion of the lumbar arteries was achieved in 14/31 vessels (12 by polyurethane grafts and 2 by polyester grafts, p < 0.001). Follow-up angiography and dissection at explantation revealed perfusion of 30/31 lumbar arteries with a collateral network in most cases. Another reason for reperfusion of initially excluded branches was distention of the polyurethane grafts with resulting shortening allowing reperfusion of 8 of the 31 originally covered branches. Histological examination revealed a complete neointimal lining and a tight contact between endovascular grafts and aorta. CONCLUSIONS: The immediate angiographic demonstration of exclusion of lumbar arteries predicts sealing characteristics of endovascular grafts. Later angiographic reappearance is due to development of a collateral network and possible shortening of self-expandable devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Standard surgical aortic valve replacement with a biological prosthesis remains the treatment of choice for low- and mid-risk elderly patients (traditionally >65 years of age) suffering from severe symptomatic aortic valve stenosis or insufficiency, and for young patients with formal contraindications to long-lasting anticoagulation. Unfortunately, despite the fact that several technical improvements have noticeably improved the resistance of pericardial and bovine bioprostheses to leaflet calcifications and ruptures, the risk of early valve failure with rapid degeneration still exists, especially for patients under haemodialysis and for patients <60 years of age at the time of surgery. Until now, redo open heart surgery under cardiopulmonary bypass and on cardioplegic arrest was the only available therapeutic option in case of bioprosthesis degeneration, but it carried a higher surgical risk when elderly patients with severe concomitant comorbidities were concerned. Since a few years, the advent of new transcatheter aortic valve procedures has opened new horizons in cardiac surgery and, in particular, the possibility of implanting stented valves within the degenerated stented bioprosthesis, the so-called 'valve-in-valve' (VinV) concept, has become a clinical practice in experienced cardiac centres. The VinV procedure represents a minimally invasive approach dedicated to high-risk redo patients, and published preliminary reports have shown a success rate of 100% with absence of significant valvular leaks, acceptable transvalvular gradients and low complication rate. However, this procedure is not riskless and the most important concerns are about the size mismatch and the right positioning within the degenerated bioprosthesis. In this article, we review the limited available literature about VinV procedures, underline important technical details for the positioning and provide guidelines to prevent valve-prosthesis mismatch comparing the three sizes of the only commercially available transapical device, the Edwards Sapien, with the inner diameter of three of the most commonly used stented bioprostheses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Purpose: To test the hypothesis that simultaneous closure of at least 2 independent vascular territories supplying the spinal cord and/or prolonged hypotension may be associated with symptomatic spinal cord ischemia (SCI) after thoracic endovascular aortic repair (TEVAR). Methods: A pattern matching algorithm was used to develop a risk model for symptomatic SCI using a prospective 63-patient single-center cohort to test the positive predictive value (PPV) of prolonged intraoperative hypotension and/or simultaneous closure of at least 2 of 4 the vascular territories supplying the spinal cord (left subclavian, intercostal, lumbar, and hypogastric arteries). This risk model was then applied to data extracted from the multicenter European Registry on Endovascular Aortic Repair Complications (EuREC). Between 2002 and 2010, the 19 centers participating in EuREC reported 38 (1.7%) cases of symptomatic spinal cord ischemia among the 2235 patients in the database. Results: In the single-center cohort, direct correlations were seen between the occurrence of symptomatic SCI and both prolonged intraoperative hypotension (PPV 1.00, 95% CI 0.22 to 1.00, p = 0.04) and simultaneous closure of at least 2 independent spinal cord vascular territories (PPV 0.67, 95% CI 0.24 to 0.91, p = 0.005). Previous closure of a single vascular territory was not associated with an increased risk of symptomatic spinal cord ischemia (PPV 0.07, 95% CI 0.01 to 0.16, p = 0.56). The combination of prolonged hypotension and simultaneous closure of at least 2 territories exhibited the strongest association (PPV 0.75, 95% CI 0.38 to 0.75, p<0.0001). Applying the model to the entire EuREC cohort found an almost perfect agreement between the predicted and observed risk factors (kappa 0.77, 95% CI 0.65 to 0.90). Conclusion: Extensive coverage of intercostal arteries alone by a thoracic stent-graft is not associated with symptomatic SCI; however, simultaneous closure of at least 2 vascular territories supplying the spinal cord is highly relevant, especially in combination with prolonged intraoperative hypotension. As such, these results further emphasize the need to preserve the left subclavian artery during TEVAR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter aortic valve therapies are the newest established techniques for the treatment of high risk patients affected by severe symptomatic aortic valve stenosis. The transapical approach requires a left anterolateral mini-thoracotomy, whereas the transfemoral method requires an adequate peripheral vascular access and can be performed fully percutaneously. Alternatively, the trans-subclavian access has been recently proposed as a third promising approach. Depending on the technique, the fine stent-valve positioning can be performed with or without contrast injections. The transapical echo-guided stent-valve implantation without angiography (the Lausanne technique) relies entirely on transoesophageal echocardiogramme imaging for the fine stent-valve positioning and it has been proved that this technique prevents the onset of postoperative contrast-related acute kidney failure. Recent published reports have shown good hospital outcomes and short-term results after transcatheter aortic valve implantation, but there are no proven advantages in using the transfemoral or the transapical technique. In particular, the transapical series have a higher mean logistic Euroscore of 27-35%, a procedural success rate above 95% and a mean 30-day mortality between 7.5 and 17.5%, whereas the transfemoral results show a lower logistic Euroscore of 23-25.5%, a procedural success rate above 90% and a 30-day mortality of 7-10.8%. Nevertheless, further clinical trials and long-term results are mandatory to confirm this positive trend. Future perspectives in transcatheter aortic valve therapies would be the development of intravascular devices for the ablation of the diseased valve leaflets and the launch of new stent-valves with improved haemodynamic, different sizes and smaller delivery systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aortic access problems due to diseased or small peripheral vessels are a major issue in endovascular aneurysm repair (EVAR). In the emergency setting, like aortic rupture after blunt trauma, or in patients with a hostile abdomen, a more proximal access to the aorta is not a pleasant perspective. We developed in situ introducer sheath dilatation as a bail-out technique for patients with difficult aortic access under various circumstances including EVAR, intra-aortic balloon pump insertion and cannulation for perfusion. The method described allows to increase the access vessel diameter by 50% (from 6 to 9 mm) or the luminal circumference from 18 to 27 F. We have used this technique in five patients without complication, very much in contrast to the traditionally practiced 'forced device insertion'.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Transcatheter aortic valve implantations (TAVI) are indicated in high risk patients requiring aortic valve replacement (AVR). However, CT-scans, coronary angiograms and intraoperative aortographies can induce contrast-related nephro-toxicity with a concrete risk of acute postoperative renal failure, especially in severely diseased patients. To prevent this complication, we routinely perform transapical (TA) TAVI guided by transesophageal echocardiogram and fluoroscopy without angiography. Material and Methods: From November 2008 to December 2009, 31 high-risk patients suffering from severe symptomatic aortic stenosis underwent TA-TAVI in our institution. The preoperative imaging assessment (cardiac CT-scan and coronary angiogram) was performed no less than 10 days before the TA-TAVI in all patients (to recover the renal function) with a low-dose protocol for injected contrast medium (equivalent to the patient's weight for the CT-scan). During the TA-TAVI, the stent-valve positioning was performed without any contrast injection. Results: 32 consecutive stent-valve were successfully positioned in 31 patients (mean age 80.76 8 8.3 years; mean EuroSCORE: 32.2 8 12.9%) through a transapical access (1 patient required 2 valves for valve embolisation). The mean preoperative creatinine and urea blood levels were 102.6 8 67.7 _ g/dl (range 53-339 _ g/dl) and 8.45 8 4.9 mmol/l, respectively. A chronic renal insufficiency affected 12 patients (38.7%) with 1 patient in pre-dialysis. Postoperatively, no patient developed acute myocardial infarction, atrio-ventricular block or acute renal insufficiency (mean creatinine level: 89.7 8 64.55 _ g/dl; urea level: 7.11 8 3.47 mmol/l) and the 30-days mortality was 9.67% (3 patients). Conclusion: Specific preoperative and intraoperative protocols that require lowdoses or absence of contrast medium are useful to preserve the renal function in high risk patients operated for TAVI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.