338 resultados para Antibodies, Monoclonal, Humanized


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transaxial tomoscintigraphy (or single-photon emission computerised tomography) was used to detect secondary deposits of carcinoma in 17 patients who had been injected with iodine-131-labelled monoclonal antibodies against carcinoembryonic antigen. Of 17 tumor sites studied by tomoscintigraphy 16 were detected (sensitivity 94%); five sites had a volume smaller than 10 cm3. Tomoscintigraphy also detected three unknown tumour deposits later confirmed by surgery or radiology. In contrast, when 21 tumour sites in the same patients were studied by rectilinear scintigraphy, only nine tumour sites were detected (sensitivity 43%), of which eight had a volume larger than 50 cm3.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radioiodinated murine monoclonal antibodies (Mabs) 81C6, Me 1-14, C12, D12, and E9, made against or reactive with human gliomas but not normal brain, and Mab UJ13A, a pan-neuroectodermal Mab reactive with normal human glial and neural cells, were evaluated in paired label studies in the D-54 MG subcutaneous human glioma xenograft model system in nude mice. Following intravenous injection in the tail vein of mice bearing 200-400 mm3 tumors, specific localization of Mabs to tumor over time (6 h-9 days) was evaluated by tissue counting; each Mab demonstrated a unique localization profile. The comparison of localization indices (LI), determined as a ratio of tissue level of Mab to control immunoglobulin with simultaneous correction for blood levels of each, showed Mabs 81C6 and Me 1-14 to steadily accumulate in glioma xenografts, maintaining LI from 5-20 at 7-9 days after Mab injection. Mab UJ13A peaked at day 1, maintaining this level through day 2, and declining thereafter. Mabs D12 and C12 peaked at days 3 and 4, respectively, and E9 maintained an LI of greater than 3 from days 3-9. Percent injected dose localized/g of tumor varied from a peak high of 16% (81C6) to a low of 5% (Me 1-14 and UJ13A). Immunoperoxidase histochemistry, performed with each Mab on a battery of primary human brain neoplasms, revealed that Mabs 81C6 and E9, which demonstrated the highest levels of percent injected dose localized/g of tumor over time, reacted with antigens expressed in the extracellular matrix. This finding suggests that extracellular matrix localization of antigen represents a biologically significant factor affecting localization and/or binding in the xenograft model used. The demonstration of significant localization, varied kinetics and patterns of localization of this localizing Mab panel warrants their continued investigation as potential imaging and therapeutic agents for human trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purified monoclonal antibodies (Mab) produced by 3 hybridomas and reacting with 3 different epitopes of carcinoembryonic antigen (CEA) were used in a solid phase enzyme immunoassay. Two Mabs were physically adsorbed to polystyrene balls and the third Mab was coupled to alkaline phosphatase using the bifunctional reagent N-succinimidyl-3-(2-pyridyldithio)-propionate. During a first incubation, CEA from heat-extracted serum samples was immunoadsorbed to the antibody coated balls. After washing of the balls, bound CEA was detected by a second incubation with the enzyme coupled Mab. The sensitivity of the assay was 0.6 ng per ml of serum. A total of 196 serum samples from patients with various types of carcinoma, with liver cirrhosis, or from healthy blood donors with or without smoking habits, were tested. The results obtained with the monoclonal enzyme immunoassay (M-EIA) were compared with those obtained with perchloric acid extracts of the same serum samples tested by an inhibition radioimmunoassay using conventional goat anti-CEA antiserum. There was an excellent correlation between the two assays. In particular, the new M-EIA gave good results for the detection of tumor recurrences in the follow-up of colon carcinoma patients. However, despite the use of exclusively monoclonal antibodies the new assay detected a similar percentage of slightly elevated CEA values as the conventional assay in patients with non-malignant disease, suggesting that the CEA associated with non-malignant diseases is immunologically identical to the CEA released by colon carcinoma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The binding specificities of 52 well-characterized monoclonal antibodies (Mabs) against carcinoembryonic antigen (CEA) from 12 different research groups were studied by immunohistochemistry and immuno flow cytometry. In addition, the binding constant for the interaction between Mab and CEA was determined by a solution-phase assay. Cryostat sections of colon carcinoma and normal colon, stomach, liver, pancreas, and spleen were studied by immunohistochemistry. Peripheral blood granulocytes, monocytes, and lymphocytes were assayed by immuno flow cytometry. The Mabs used here have previously been classified into five essentially nonoverlapping epitope groups (GOLD 1-5) (Cancer Res., 49: 4852-4858, 1989). Most Mabs cross-reacted with different normal tissues, ranging from highly cross-reactive Mabs (positive reaction with 8 of 9 discriminating tissues) to relatively specific Mabs (positive reaction with 1 of 9 discriminating tissues). Five Mabs (10%) were specific, reacting only with colon carcinoma, normal colon mucosa, and normal gastric foveola. There was a correlation between epitope group and binding specificity. Mabs with a high degree of CEA specificity almost exclusively belonged to epitope groups 1, 2, and 3, while highly cross-reactive Mabs belonged to epitope groups 4 and 5. There was no correlation between antibody specificity and affinity for CEA. Specific Mabs with high as well as low affinity were found.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To avoid the exclusive use of rodent monoclonal antibodies (MAbs) in patients for the detection of tumors by immunoscintigraphy and for radioimmunotherapy, swine MAbs were produced that are directed against carcinoembryonic antigen (CEA). Spleen cells from 2 pigs immunized with purified colon carcinoma CEA were fused with a nonsecreting mouse myeloma cell line by conventional methods, except that a particularly long immunization protocol and large amounts of spleen and myeloma cells were used. Of 1,200 growing hybrids tested, 20 were found initially to produce antibodies binding to radiolabeled CEA. Seven stable clones producing anti-CEA MAbs for more than 6 months were derived from these hybrids by repeated subcloning. The pig origin of the seven MAbs was demonstrated in a solid-phase CEA enzyme immunoassay where anti-pig immunoglobin (Ig) antibodies coupled to peroxidase gave a positive reaction while anti-mouse Ig antibodies were entirely negative. All swine MAbs were of the IgG isotype. Three anti-CEA MAbs showed no cross-reactivity with granulocytes, while four others gave various degrees of reactivity with different granulocyte glycoproteins. Competitive binding to CEA performed for two purified swine MAbs showed that they recognized two different epitopes. The affinity constants measured for these two MAbs by Scatchard plot on purified CEA were high (1.2 X 10(9) and 1.2 X 10(10) liter/mol). One of the MAbs was tested in vivo for tumor localization by injection, after radiolabeling, in nude mice bearing human colon carcinoma xenograft. High ratios of tumor to normal tissue were obtained with mean values of 10.5 for intact MAbs and of 26.8 for F(ab')2 fragments of the porcine MAb. The results showed that heterofusion with this particular protocol can be used to produce swine MAbs of high affinity and specificity for a well-defined tumor marker. These reagents may have an important clinical utility, particularly in patients who became sensitized to mouse immunoglobulins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We produced three monoclonal antibodies, BF7, GE2 and CG12, against cultured human glioma cells. Their specificity was tested by an indirect antibody-binding radioimmunoassay on a panel of glial and non-glial tumor cell lines. BF7 and GE2 react preferentially with glioma cells and, except for one colon carcinoma line, they do not bind to the control non-neuroectodermal cells; they appear to be directed against common malignant glioma associated antigens. CG12, the third monoclonal antibody, binds to the great majority of tumor cell lines of neuroectodermal origin and does not bind to any other cell lines tested.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reactivity spectrum of three monoclonal antibodies (Mabs) to human malignant glioma, five Mabs to melanomas and one Mab anti-HLA-DR was investigated by an indirect antibody binding radioimmunoassay on a panel of cells derived from 60 glioma lines, including 47 malignant astrocytomas, 11 low-grade astrocytomas and two malignant ependymomas as well on cells from 12 melanoma, three neuroblastoma, three medulloblastoma, two schwannoma, two retinoblastoma, two choroïd plexus papilloma, ten meningioma and 12 unrelated tumor lines. The anti-glioma Mabs BF7 and GE2 reacted preferentially with gliomas, while the anti-glioma Mab CG12 reacted with gliomas, melanomas, neuroblastomas and medulloblastomas. The five anti-melanoma Mabs reacted with gliomas, neuroblastomas and medulloblastomas. The anti-HLA-DR Mab D1-12 reacted with gliomas, melanomas and some meningiomas. On the basis of the data presented, we describe three different antigenic systems; the first one is glioma-associated, the second one is related to differentiation antigens expressed on cells derived from the neuroectoderm and the third is represented by HLA-DR antigens which are expressed not only on B-lymphoblastoid cells but also on melanomas and gliomas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the selection of monoclonal antibodies (MAb) raised against purified carcinoembryonic antigen (CEA), two MAbs were identified which immunoprecipitated a glycoprotein of 95 kD present both in perchloric acid extracts of normal lung and on the surface of normal granulocytes. This antigen was distinct from the previously reported normal glycoprotein crossreacting with CEA (NCA) which had a molecular weight of 55 kD. The difference between the smaller and the larger crossreacting antigens termed NCA-55 and NCA-95, respectively, was demonstrated by SDS-polyacrylamide gel electrophoresis, by elution from Sephadex-G200 and by selective binding to a series of anti-CEA MAb. Out of six MAb which all bound CEA purified from colon carcinoma, three did not react with these two crossreacting antigens, one bound only NCA-95, one reacted only with NCA-55 and one reacted with both NCA-55 and NCA-95. Immunoadsorbent purified preparations of 125I labelled NCA-95 and NCA-55 were found useful for the screening of new anti-CEA MAb. In addition, when tested on frozen sections of colon carcinoma, normal spleen, normal lung and pancreas, each type of MAb gave a clearly different pattern of reactivity. The three anti-CEA MAb which did not bind any of the crossreacting antigens stained only the colon carcinoma cells; the MAb binding to either one of the two types of NCA gave a similar pattern of reactivity both on colon carcinoma cells and on granulocytes. However, on normal lung and pancreas, the MAb binding NCA-55 stained granulocytes as well as bronchiolar and alveolar epithelial cells in lung and inter- and intra-lobular duct epithelial cells in pancreas, whereas the MAb binding only NCA-95 stained only the granulocytes. Thus, the newly identified NCA-95 appears to differ from NCA-55 not only in terms of molecular size and antigenicity but also by the fact that in normal lung and pancreas it is found in granulocytes but not in epithelial cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A murine monoclonal antibody (mAb) specific for apocytochrome c was found to be able to either inhibit or enhance the helper activity of mouse apocytochrome c-specific T cell clones and populations in a hapten (trinitrophenyl)-carrier (apocytochrome c) system of T-B cell cooperation. This effect of the mAb was carrier specific, could not be ascribed simply to a shift in the kinetics of the antibody response and was observed using apocytochrome c T helper cells of different mouse haplotypes. In addition, the anti-apocytochrome c mAb was able to inhibit specific T helper cell activity even when the T cells were triggered with antigen-presenting cells pulsed with antigen. Taken together, these results suggested that the mAb was inhibiting helper activity due to its ability to modify the interaction between T cells and antigen-presenting cells.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Personal results are presented to illustrate the development of immunoscintigraphy for the detection of cancer over the last 12 years, from the early experimental results in nude mice grafted with human colon carcinoma to the most modern form of immunoscintigraphy applied to patients, using I123 labeled Fab fragments from monoclonal anti-CEA antibodies detected by single photon emission computerized tomography (SPECT). The first generation of immunoscintigraphy used I131 labeled, immunoadsorbent purified, polyclonal anti-CEA antibodies and planar scintigraphy, as the detection system. The second generation used I131 labeled monoclonal anti-CEA antibodies and SPECT, while the third generation employed I123 labeled fragments of monoclonal antibodies and SPECT. The improvement in the precision of tumor images with the most recent forms of immunoscintigraphy is obvious. However, we think the usefulness of immunoscintigraphy for routine cancer management has not yet been entirely demonstrated. Further prospective trials are still necessary to determine the precise clinical role of immunoscintigraphy. A case report is presented on a patient with two liver metastases from a sigmoid carcinoma, who received through the hepatic artery a therapeutic dose (100 mCi) of I131 coupled to 40 mg of a mixture of two high affinity anti-CEA monoclonal antibodies. Excellent localisation in the metastases of the I131 labeled antibodies was demonstrated by SPECT and the treatment was well tolerated. The irradiation dose to the tumor, however, was too low at 4300 rads (with 1075 rads to the normal liver and 88 rads to the bone marrow), and no evidence of tumor regression was obtained. Different approaches for increasing the irradiation dose delivered to the tumor by the antibodies are considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: We conducted a comprehensive review of the design, implementation, and outcome of first-in-human (FIH) trials of monoclonal antibodies (mAbs) to clearly determine early clinical development strategies for this class of compounds. METHODS: We performed a PubMed search using appropriate terms to identify reports of FIH trials of mAbs published in peer-reviewed journals between January 2000 and April 2013. RESULTS: A total of 82 publications describing FIH trials were selected for analysis. Only 27 articles (33%) reported the criteria used for selecting the starting dose (SD). Dose escalation was performed using rule-based methods in 66 trials (80%). The median number of planned dose levels was five (range, two to 13). The median of the ratio between the highest planned dose and the SD was 27 (range, two to 3,333). Although in 56 studies (68%) at least one grade 3 or 4 toxicity event was reported, no dose-limiting toxicity was observed in 47 trials (57%). The highest planned dose was reached in all trials, but the maximum-tolerated dose (MTD) was defined in only 13 studies (16%). The median of the ratio between MTD and SD was eight (range, four to 1,000). The recommended phase II dose was indicated in 34 studies (41%), but in 25 (73%) of these trials, this dose was chosen without considering toxicity as the main selection criterion. CONCLUSION: This literature review highlights the broad design heterogeneity of FIH trials testing mAbs. Because of the limited observed toxicity, the MTD was infrequently reached, and therefore, the recommended phase II dose for subsequent clinical trials was only tentatively defined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cation exchange chromatography (CEX) is a well established strategy for the characterization of monoclonal antibodies (mAbs). The optimization of mobile phase conditions is well described in the literature, but there is a lack of information about CEX stationary phases for the analysis of therapeutic proteins. The aim of this study was to compare five state-of-the-art CEX stationary phases based on the retention, selectivity and resolving power achieved in pH- and salt-gradient modes, with various therapeutic mAbs and their variants. The Sepax Antibodix WCX-NP3, Thermo MAbPac SCX-10 RS, YMC BioPro SP-F, Waters Protein-Pak Hi Res SP and Agilent Bio mAb NP1.7 SS were considered in this study. In terms of retention, the YMC Bio Pro SP-F material was the less retentive one, while the Agilent Bio mAb NP1.7 SS provides the highest retention. Regarding the selectivity achieved between the main mAbs isoforms and their variants, the Thermo MabPac SCX column generally gave the highest selectivity. Finally, it was hard to rank columns in term of kinetic performance since their performance is strongly solute (mAb) and elution mode (pH or salt gradient) dependent. However, the highest resolution--in most cases--was observed on the strong cation exchanger YMC Bio Pro SP-F material.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Previous work has shown that aggregate cultures prepared from fetal rat telencephalon and grown in a chemically defined medium offer a useful model to study developmental processes such as myelin synthesis. Since compact myelin is formed in these cultures, we investigated the possibility to use this culture system to study demyelinating mechanisms. In particular, we examined the effect of a monoclonal antibody (8-18C5) directed against the myelin/oligodendrocyte glycoprotein (MOG). We found that addition of anti-MOG antibodies and complement to aggregate cultures led to a highly significant decrease in myelin basic protein (MBP) content and 2',3'-cyclic nucleotide 3'-phosphohydrolase (CNP) specific activity. These results indicate that, in our culture system, anti-MOG antibodies have a strong demyelinating effect.