167 resultados para AIRWAY MUCUS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulmonary involvement in Fabry disease has received less attention than the effects of the disease on the kidneys, nervous system or heart. However, data from FOS -the Fabry Outcome Survey - are now helping to elucidate the pulmonary manifestations of Fabry disease. Twenty-three patients out of a cohort of 67 analysed in FOS have been identified with airway obstruction, as defined by a ratio of forced expiratory volume in 1 second to forced vital capacity of less than 0.7. This prevalence is much greater than would be expected in the general population, with the main risk factors appearing to be increasing age and male gender. Spirometric analysis has revealed that the airway obstruction is clinically much more similar to chronic obstructive pulmonary disease than to asthma. Although little is known about the anatomical changes responsible for airway obstruction in patients with Fabry disease, airway wall hyperplasia and/or fibrosis are potential causes. Treatment of patients with moderate or severe airway obstruction should include inhaled bronchodilators, and individuals who smoke should be encouraged to stop. Further studies and future analyses of FOS data should determine whether enzyme replacement therapy is able to help or prevent the pulmonary manifestations of Fabry disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION. Neurally Adjusted Ventilatory Assist (NAVA) is a new ventilatory mode in which ventilator settings are adjusted based on the electrical activity detected in the diaphragm (Eadi). This mode offers significant advantages in mechanical ventilation over standard pressure support (PS) modes, since ventilator input is determined directly from patient ventilatory demand. Therefore, it is expected that tidal volume (Vt) under NAVA would show better correlation with Eadi compared with PS, and exhibit greater variability due to the variability in the Eadi input to the ventilator. OBJECTIVES. To compare tidal volume variability in PS and NAVA ventilation modes, and its correlation with patient ventilatory demand (as characterized by maximum Eadi). METHODS. Acomparative study of patient-ventilator interaction was performed for 22 patients during standard PS with clinician determined ventilator settings; and NAVA, with NAVA gain set to ensure the same peak airway pressure as the total pressure obtained in PS. A 20 min continuous recording was performed in each ventilator mode. Respiratory rate, Vt, and Eadi were recorded. Tidal volume variance and Pearson correlation coefficient between Vt and Eadi were calculated for each patient. A periodogram was plotted for each ventilator mode and each patient, showing spectral power as a function of frequency to assess variability. RESULTS. Median, lower quartile and upper quartile values for Vt variance and Vt/Eadi correlation are shown in Table 1. The NAVA cohort exhibits substantially greater correlation and variance than the PS cohort. Power spectrums for Vt and Eadi are shown in Fig. 1 (PS and NAVA) for a typical patient. The enlarged section highlights how changes in Eadi are highly synchronized with NAVA ventilation, but less so for PS. CONCLUSIONS. There is greater variability in tidal volume and correlation between tidal volume and diaphragmatic electrical activity with NAVA compared to PS. These results are consistent with the improved patient-ventilator synchrony reported in the literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The transfer factor for carbon monoxide (TLCO) is widely used in pulmonary function laboratories because it represents a unique non-invasive window on pulmonary microcirculation. The TLCO is the product of two primary measurements, the alveolar volume (VA) and the CO transfer coefficient (KCO). This test is most informative when VA and KCO are examined, together with their product TLCO. In a normal lung, a low VA due to incomplete expansion is associated with an elevated KCO, resulting in a mildly reduced TLCO. Thus, in case of low VA, a seemingly "normal KCO" must be interpreted as an abnormal gas transfer. The most common clinical conditions associated with an abnormal TLCO are characterised by a limited number of patterns for VA and KCO: incomplete lung expansion, discrete loss of alveolar units, diffuse loss of alveolar units, emphysema, pulmonary vascular disorders, high pulmonary blood volume, alveolar haemorrhage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Creation of a patent subglottic airway after partial cricotracheal resection (PCTR) may not always result in successful decannulation due to associated parameters such as co-morbidity and/or glottic involvement. We classified patients after incorporating these additional parameters into the original Myer-Cotton classification to assess whether this could better predict the outcome measures after PCTR. METHODS: One hundred children with Myer-Cotton grade III or IV subglottic stenosis who underwent PCTR between 1978 and 2008 were identified from a prospectively collected database. The patients were classified into four groups based on the association of co-morbidity and/or glottic involvement. Delay in decannulation, revision open surgery and rates of decannulation were the outcome measures compared between the groups. RESULTS: There were 68 children with Myer-Cotton grade III and 32 children with grade IV stenosis. Based on the new classification, there were 36 children with isolated SGS, 31 with associated co-morbidity, 19 with associated glottic involvement and 14 children with both co-morbidity and glottic involvement. A trend towards less optimal results was noticed with the association of co-morbidity and/or glottic involvement. Statistical significance was reached for maximum decannulation failure in the group with both co-morbidity and glottic involvement. Delayed decannulation significantly correlated in the group with associated glottic involvement. CONCLUSION: This new classification is relatively simple and aimed at providing more accurate and uniform prognostic information to both patients and surgeons when dealing with the whole spectrum of severe SGS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Respiratory care is universally recognised as useful, but its indications and practice vary markedly. In order to improve appropriateness of respiratory care in our hospital, we developed evidence-based local guidelines in a collaborative effort involving physiotherapists, physicians, and health services researchers. Methods: Recommendations were developed using the standardised RAND appropriateness method. A literature search was performed for the period between 1995 and 2008 based on terms associated with guidelines and with respiratory care. Publications were assessed according to the Oxford classification of quality of evidence. A working group prepared proposals for recommendations which were then independently rated by a multidisciplinary expert panel. All recommendations were then discussed in common and indications for procedures were rated confidentially a second time by the experts. Each indication for respiratory care was classified as appropriate, uncertain, or inappropriate, based on the panel median rating and the degree of intra-panel agreement. Results: Recommendations were formulated for the following procedures: non-invasive ventilation, continuous positive airway pressure, intermittent positive pressure breathing, intrapulmonary percussive ventilation, mechanical insufflation-exsufflation, incentive spirometry, positive expiratory pressure, nasotracheal suctioning, noninstrumental airway clearance techniques. Each recommendation referred to a particular medical condition, and was assigned to a hierarchical category based on the quality of evidence from literature supporting the recommendation and on the consensus of experts. Conclusion: Despite a marked heterogeneity of scientific evidence, the method used allowed us to develop commonly agreed local guidelines for respiratory care. In addition, this work fostered a closer relationship between physiotherapists and physicians in our institution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The amiloride-sensitive epithelial sodium channel (ENaC) constitutes a limiting step in sodium reabsorption across distal airway epithelium and controlling mucociliary clearance. ENaC is activated by serine proteases secreted in the extracellular milieu. In cystic fibrosis lungs, high concentrations of secreted neutrophil elastase (NE) are observed. hNE could activate ENaC and contribute to further decreased mucociliary clearance. The aims of this study were (i) to test the ability of an engineered human neutrophil elastase inhibitor (EPI-hNE4) to specifically inhibit the elastase activation of ENaC-mediated amiloride-sensitive currents (I(Na)) and (ii) to examine the effect of elastase on cell surface expression of ENaC and its cleavage pattern (exogenous proteolysis). Oocytes were exposed to hNE (10-100 microg/ml) and/or trypsin (10 microg/ml) for 2-5 min in the presence or absence of EPI-hNE4 (0.7 microm). hNE activated I(Na) 3.6-fold (p < 0.001) relative to non-treated hENaC-injected oocytes. EPI-hNE4 fully inhibited hNE-activated I(Na) but had no effect on trypsin- or prostasin-activated I(Na). The co-activation of I(Na) by hNE and trypsin was not additive. Biotinylation experiments revealed that cell surface gamma ENaC (but not alpha or beta ENaC) exposed to hNE for 2 min was cleaved (as a 67-kDa fragment) and correlated with increased I(Na). The elastase-induced exogenous proteolysis pattern is distinct from the endogenous proteolysis pattern induced upon preferential assembly, suggesting a causal relationship between gamma ENaC cleavage and ENaC activation, taking place at the plasma membrane.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Asthma is a chronic inflammatory airway disease, characterised by bronchial hyperresponsiveness causing bronchoconstriction, and thereby provoking typical symptoms (dyspnoea, cough, wheezing). Bronchial hyperres- ponsiveness indicates a temporary airflow limitation when exposed to a bronchoconstricting stimulus. Its measurement by challenge tests can be a valuable tool for confirming or excluding asthma, as well as for evaluating the efficacy of treatment. However, the origin of bronchial hyperresponsiveness is multifactorial and the different challenge tests are not equivalent. Direct challenge tests, like methacholine, mainly reflect chronic airway remo- delling, whereas indirect tests, like mannitol, better reflect bronchial inflammation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A complete secretory immunologie system has been identified in the equine species. It is characterised by the presence of a secretory component either bound to secretory IgA (SigA) or remaining in the free form (FSC). The mean molecular weights of SigA, serum lgA and FSC have been estimated. The homology of the equine and human IgA classes have been demonstrated by cross-reaction with anti-human lgA antisera. A quantit ative study of equine immunoglobulins in various fluids have shown that SlgA is predominant in saliva, mature milk, nasal and lacrimal secretions, but not in colostrum. In vitro binding of human and bovine FSC is found to occur mostly with the polymerie form of equine serum lgA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The contribution of respiratory muscle work to the development of the O(2) consumption (Vo(2)) slow component is a point of controversy because it has been shown that the increased ventilation in hypoxia is not associated with a concomitant increase in Vo(2) slow component. The first purpose of this study was thus to test the hypothesis of a direct relationship between respiratory muscle work and Vo(2) slow component by manipulating inspiratory resistance. Because the conditions for a Vo(2) slow component specific to respiratory muscle can be reached during intense exercise, the second purpose was to determine whether respiratory muscles behave like limb muscles during heavy exercise. Ten trained subjects performed two 8-min constant-load heavy cycling exercises with and without a threshold valve in random order. Vo(2) was measured breath by breath by using a fast gas exchange analyzer, and the Vo(2) response was modeled after removal of the cardiodynamic phase by using two monoexponential functions. As anticipated, when total work was slightly increased with loaded inspiratory resistance, slight increases in base Vo(2), the primary phase amplitude, and peak Vo(2) were noted (14.2%, P < 0.01; 3.5%, P > 0.05; and 8.3%, P < 0.01, respectively). The bootstrap method revealed small coefficients of variation for the model parameter, including the slow-component amplitude and delay (15 and 19%, respectively), indicating an accurate determination for this critical parameter. The amplitude of the Vo(2) slow component displayed a 27% increase from 8.1 +/- 3.6 to 10.3 +/- 3.4 ml. min(-1). kg(-1) (P < 0.01) with the addition of inspiratory resistance. Taken together, this increase and the lack of any differences in minute volume and ventilatory parameters between the two experimental conditions suggest the occurrence of a Vo(2) slow component specific to the respiratory muscles in loaded condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Application of cervical collars may reduce cervical spine movements but render tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesised that despite the presence of a Philadelphia Patriot (R) cervical collar and with the patient's head taped to the trolley, tracheal intubation would be possible in 50 adult patients using the GlideScope (R) and its dedicated stylet. Laryngoscopy was attempted using a Macintosh laryngoscope with a size 4 blade, and the modified Cormack-Lehane grade was scored. Subsequently, laryngoscopy with the GlideScope was graded and followed by tracheal intubation. All patients' tracheas were successfully intubated with the GlideScope. The median (IQR) intubation time was 50 s (43-61 s). The modified Cormack-Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScope (p < 0.0001), reaching grade 2a in most patients. Tracheal intubation in patients wearing a semi-rigid collar and having their head taped to the trolley is possible with the help of the GlideScope.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Using a bench test model, we investigated the hypothesis that neonatal and/or adult ventilators equipped with neonatal/pediatric modes currently do not reliably administer pressure support (PS) in neonatal or pediatric patient groups in either the absence or presence of air leaks. METHODS: PS was evaluated in 4 neonatal and 6 adult ventilators using a bench model to evaluate triggering, pressurization, and cycling in both the absence and presence of leaks. Delivered tidal volumes were also assessed. Three patients were simulated: a preterm infant (resistance 100 cm H2O/L/s, compliance 2 mL/cm H2O, inspiratory time of the patient [TI] 400 ms, inspiratory effort 1 and 2 cm H2O), a full-term infant (resistance 50 cm H2O/L/s, compliance 5 mL/cm H2O, TI 500 ms, inspiratory effort 2 and 4 cm H2O), and a child (resistance 30 cm H2O/L/s, compliance 10 mL/cm H2O, TI 600 ms, inspiratory effort 5 and 10 cm H2O). Two PS levels were tested (10 and 15 cm H2O) with and without leaks and with and without the leak compensation algorithm activated. RESULTS: Without leaks, only 2 neonatal ventilators and one adult ventilator had trigger delays under a given predefined acceptable limit (1/8 TI). Pressurization showed high variability between ventilators. Most ventilators showed TI in excess high enough to seriously impair patient-ventilator synchronization (> 50% of the TI of the subject). In some ventilators, leaks led to autotriggering and impairment of ventilation performance, but the influence of leaks was generally lower in neonatal ventilators. When a noninvasive ventilation algorithm was available, this was partially corrected. In general, tidal volume was calculated too low by the ventilators in the presence of leaks; the noninvasive ventilation algorithm was able to correct this difference in only 2 adult ventilators. CONCLUSIONS: No ventilator performed equally well under all tested conditions for all explored parameters. However, neonatal ventilators tended to perform better in the presence of leaks. These findings emphasize the need to improve algorithms for assisted ventilation modes to better deal with situations of high airway resistance, low pulmonary compliance, and the presence of leaks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The neurogenic shock is a common complication of spinal cord injury, especially when localized at the cervical level. Characterized by a vasoplegia (hypotension) and bradycardia, the neurogenic shock is secondary to the damage of the sympathetic nervous system. The clinical presentation often includes tetraplegia, with or without respiratory failure. Early treatment aims to minimize the occurrence of secondary spinal cord lesions resulting from systemic ischemic injuries. Medical management consists in a standardized ABCDE approach, in order to stabilize vital functions and immobilize the spine. The hospital care includes performing imaging, further measures of neuro-resuscitation, and coordinated surgical assessment and treatment of any other injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose of the study: Basic life support (BLS) and automated externaldefibrillation (AED) represent important skills to be acquired duringpregraduate medical training. Since 3 years, our medical school hasintroduced a BLS-AED course (with certification) for all second yearmedical students. Few reports about quality and persistence over timeof BLS-AED learning are available to date in the medical literature.Comprehensive evaluation of students' acquired skills was performedat the end of the 2008 academic year, 6 month after certification.Materials and methods: The students (N = 142) were evaluated duringa 9 minutes «objective structured clinical examination» (OSCE) station.Out of a standardized scenario, they had to recognize a cardiac arrestsituation and start a resuscitation process. Their performance wererecorded on a PC using an Ambuman(TM) mannequin and the AmbuCPR software kit(TM) during a minimum of 8 cycles (30 compressions:2 ventilations each). BLS parameters were systematically checked. Nostudent-rater interactions were allowed during the whole evaluation.Results: Response of the victim was checked by 99% of the students(N = 140), 96% (N = 136) called for an ambulance and/or an AED. Openthe airway and check breathing were done by 96% (N = 137), 92% (N =132) gave 2 rescue breaths. Pulse was checked by 95% (N=135), 100%(N = 142) begun chest compression, 96% (N = 136) within 1 minute.Chest compression rate was 101 ± 18 per minute (mean ± SD), depthcompression 43 ± 8 mm, 97% (N = 138) respected a compressionventilationratio of 30:2.Conclusions: Quality of BLS skills acquisition is maintained during a6-month period after a BLS-AED certification. Main targets of 2005 AHAguidelines were well respected. This analysis represents one of thelargest evaluations of specific BLS teaching efficiency reported. Furtherfollow-up is needed to control the persistence of these skills during alonger time period and noteworthy at the end of the pregraduatemedical curriculum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Airborne microbial products have been reported to promote immune responses that suppress asthma, yet how these beneficial effects take place remains controversial and poorly understood. Methods We exposed mice to the bacterium Escherichia coli and subsequently induced allergic airway inflammation through sensitization and intranasal challenge with ovalbumin. Results Pulmonary exposure to the bacterium Escherichia coli leads to a suppression of allergic airway inflammation. This immune modulation was neither mediated by the induction of a T helper 1 (Th1) response nor regulatory T cells; however, it was dependent on Toll-like receptor 4 (TLR4) but did not involve TLR desensitisation. Dendritic cell migration to the draining lymph nodes and activation of T cells was unaffected by prior exposure to E.coli, while dendritic cells in the lung displayed a less activated phenotype and had impaired antigen presentation capacity. Consequently, in situ Th2 cytokine production was abrogated. The suppression of airway hyper-responsiveness was mediated through the recruitment of gd T cells; however, the suppression of dendritic cells and T cells was mediated through a distinct mechanism that could not be overcome by the local administration of activated dendritic cells, or by the in vivo administration of tumour necrosis factor a. Conclusion Our data reveal a localized immunoregulatory pathway that acts to protect the airways from allergic inflammation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Résumé: La formation des atélectasies durant l'induction de l'anesthésie générale est plus importante chez le patient obèse morbide. Nous avons démontré dans des travaux de recherche antérieurs que l'utilisation de la PEEP (Pression Positive en Fin d'Expiration) durant l'induction de l'anesthésie prévient la formation d'atélectasies chez des patients non obèses. Par conséquent, nous voulions étudier l'efficacité de la pression positive en fin d'expiration chez le patient obèse morbide dans la prévention de la formation d'atélectasies. Nous avons fait une étude de 23 patients obèses morbides (BMI > 35 kg / m2) dans 2 groupes. Dans le groupe utilisant la pression positive en fin d'expiration, les patients respiraient 100% d'oxygène pendant 5 minutes par l'intermédiaire d'un masque facial type CPAP avec une pression de 10 cm H20. Après l'induction de l'anesthésie, nous avons ventilé les patients au masque facial avec une PEEP de 10 cm H20. Dans le groupe de contrôle, nous avons procédé au même type d'induction sans utiliser la pression positive en fin d'expiration. La surface de poumon atélectatique a été évaluée par tomographie (CT scann). L'étude des échanges gazeux se faisait à 2 reprises, à partir de gazométries réalisées juste avant l'induction de l'anesthésie puis juste après l'intubation. Après l'induction de l'anesthésie et l'intubation, les patients du groupe de contrôle présentaient une quantité d'atélectasies plus importante que les patients du groupe où la PEEP avait été utilisée (10.4% + 4.8% dans le groupe de contrôle versus 1.3% dans le groupe utilisant la pression positive en fin d'expiration p < 0.001). Après l'intubation, en présence d'une fraction inspirée en oxygène à 100%, la Pa02 était significativement supérieure dans le groupe ayant utilisé la pression positive en fin d'expiration en comparaison avec le groupe de contrôle (respectivement 457 ± 130 mmHg versus 315 ± 100 mmHg). Nous avons conclu que chez le patient obèse morbide, le recours à la pression positive en fin d'expiration lors de l'induction de l'anesthésie permet de prévenir largement la formation d'atélectasies et s'accompagne d'une meilleure oxygénation. Abstract: Atelectasis caused by general anesthesia is increased in morbidly obese patients. We have shown that application of positive end-expiratory pressure (PEEP) during the induction of anesthesia prevents atelectasis formation in nonobese patients. We therefore studied the efficacy of PEEP in morbidly obese patients to prevent atelectasis. Twenty-three adult morbidly obese patients (b ody mass index >35 kg/m2) were randomly assigned to one of two groups. In the PEEP group, patients breathed 100% oxygen (5 min) with a continuous positive airway pressure of 10 cm H20 and, after the induction, mechanical ventilation via a face mask with a PEEP of 10 cm H2O. In the control group, the same induction was applied but without continuous positive airway pressure or PEEP. Atelectasis, determined by computed tomography, and blood gas analysis were measured twice: before the induction and directly after intubation. After endotracheal intubation, patients of the control group showed an increase in the amount of atelectasis, which was much larger than in the PEEP group (10.4% -± 4.8% in control group versus 1.7% ± 1.3% in PEEP group; P <0.001). After in.tubation with a fraction of inspired oxygen of 1.0, Pao, was significantly higher in the PEEP group compared with the control group (457 ±- 130 mm Hg versus 315 ± 100 mm Hg, respectively; P = 0.035) We conclude that in morbidly obese patients, atelectasis formation is largely prevented by PEEP applied during the anesthetic induction and is associated with a better oxygenation.