85 resultados para wall foundation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors report an atypical late onset of a big axillary lymphatic malformation in a 41-year-old male. Considering the patient's history and clinical findings at first presentation, the swelling was highly suspicious for malignancy or cystic echinococcosis. A consequent CT showed non infiltrative growth with inhomogeneous density but remained non conclusive regarding diagnosis. Subsequently incision biopsy revealed lymphatic tissue and raised suspicion for lymphatic malformation. The tumour was excised completely and showed no recurrence in a 1-year follow up. Late onset lymphatic malformations can mimic malignant tumours or other rare conditions such as echinococcosis which has to be taken into consideration as differential diagnosis especially in known areas of hydatid diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le "Chest wall syndrome" (CWS) est défini comme étant une source bénigne de douleurs thoraciques, localisées sur la paroi thoracique antérieure et provoquées par une affection musculosquelettique. Le CWS représente la cause la plus fréquente de douleurs thoraciques en médecine de premier recours. Le but de cette étude est de développer et valider un score de prédiction clinique pour le CWS. Une revue de la littérature a d'abord été effectuée, d'une part pour savoir si un tel score existait déjà, et d'autre part pour retrouver les variables décrites comme étant prédictives d'un CWS. Le travail d'analyse statistique a été effectué avec les données issues d'une cohorte clinique multicentrique de patients qui avaient consulté en médecine de premier recours en Suisse romande avec une douleur thoracique (59 cabinets, 672 patients). Un diagnostic définitif avait été posé à 12 mois de suivi. Les variables pertinentes ont été sélectionnées par analyses bivariées, et le score de prédiction clinique a été développé par régression logistique multivariée. Une validation externe de ce score a été faite en utilisant les données d'une cohorte allemande (n= 1212). Les analyses bivariées ont permis d'identifier 6 variables caractérisant le CWS : douleur thoracique (ni rétrosternale ni oppressive), douleur en lancées, douleur bien localisée, absence d'antécédent de maladie coronarienne, absence d'inquiétude du médecin et douleur reproductible à la palpation. Cette dernière variable compte pour 2 points dans le score, les autres comptent pour 1 point chacune; le score total s'étend donc de 0 à 7 points. Dans la cohorte de dérivation, l'aire sous la courbe sensibilité/spécificité (courbe ROC) est de 0.80 (95% de l'intervalle de confiance : 0.76-0.83). Avec un seuil diagnostic de > 6 points, le score présente 89% de spécificité et 45% de sensibilité. Parmi tous les patients qui présentaient un CWS (n = 284), 71% (n = 201) avaient une douleur reproductible à la palpation et 45% (n= 127) sont correctement diagnostiqués par le score. Pour une partie (n = 43) de ces patients souffrant de CWS et correctement classifiés, 65 investigations complémentaires (30 électrocardiogrammes, 16 radiographies du thorax, 10 analyses de laboratoire, 8 consultations spécialisées, et une tomodensitométrie thoracique) avaient été réalisées pour parvenir au diagnostic. Parmi les faux positifs (n = 41), on compte trois angors stables (1.8% de tous les positifs). Les résultats de la validation externe sont les suivants : une aire sous la courbe ROC de 0.76 (95% de l'intervalle de confiance : 0.73-0.79) avec une sensibilité de 22% et une spécificité de 93%. Ce score de prédiction clinique pour le CWS constitue un complément utile à son diagnostic, habituellement obtenu par exclusion. En effet, pour les 127 patients présentant un CWS et correctement classifiés par notre score, 65 investigations complémentaires auraient pu être évitées. Par ailleurs, la présence d'une douleur thoracique reproductible à la palpation, bien qu'étant sa plus importante caractéristique, n'est pas pathognomonique du CWS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Isogenic Staphylococcus aureus strains with different capacities to produce sigma(B) activity were analyzed for their ability to attach to fibrinogen- or fibronectin-coated surfaces or platelet-fibrin clots and to cause endocarditis in rats. In comparison to the sigma(B)-deficient strain, BB255, which harbors an rsbU mutation, both rsbU-complemented and sigma(B)-overproducing derivatives exhibited at least five times greater attachment to fibrinogen- and fibronectin-coated surfaces and showed increased adherence to platelet-fibrin clots. No differences in adherence were seen between BB255 and a DeltarsbUVWsigB isogen. Northern blotting analyses revealed that transcription of clfA, encoding fibrinogen-binding protein clumping factor A, and fnbA, encoding fibronectin-binding protein A, were positively influenced by sigma(B). Sigma(B) overproduction resulted in a statistically significant increase in positive spleen cultures and enhanced bacterial densities in both the aortic vegetations and spleens at 16 h postinoculation. In contrast, at 72 h postinoculation, tissues infected with the sigma(B) overproducer had lower bacterial densities than did those infected with BB255. These results suggest that although sigma(B) appears to increase the adhesion of S. aureus to various host cell-matrix proteins in vitro, it has limited effect on pathogenesis in the rat endocarditis model. Sigma(B) appears to have a transient enhancing effect on bacterial density in the early stages of infection that is lost during progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface characteristics (area, chemical reactivity) play an important role in cell response to nanomaterials. The aim of this study was to evaluate the oxidative and inflammatory effects of multi−wall carbon nanotubes (MWCNT) uncoated (P0) or coated with carboxylic polyacid or polystyrene polybutadiene polymetacrylate of methyl polymers (P1 and P2 respectively) on murine macrophages (RAW 264.7 cell line). Carbon black nanoparticles (CB, diameter 95 nm) and crocidolite fibers (diameter: 80 nm, length: < 10 μm) were used as controls. Surface functional groups present on MWCNTs were analyzed by Knudsen flow reactor. The amount of acidic sites was P1> P0> P2, for basic sites was P0> P1>> P2 and for oxidizable sites was P0> P2> P1. In contact with cells, P2 formed smaller aggregates than P0 and P1, which were of similar size. Optical microscopy showed the formation of vacuoles after exposure only to P0, P1 and crocidolite. Incubation of cells with P0, P1 and crocidolite fibers induced a significant and similar decrease in metabolic activity, whereas P2 and CB had no effect. Cell number and membrane permeability were unmodified by incubation with the different particles. Incubation of macrophages with P0, P1 and crocidolite induced a dose− and time−dependent increase in mRNA expression of oxidative stress marker (HO−1, GPX1) and inflammatory mediators (TNF−a, MIP−2). No such responses were observed with P2 and CB. In conclusion, MWCNT coated with a carboxylic polyacid polymer exerted similar oxidative and inflammatory effects to uncoated MWCNT. By contrast, no such effects were observed with MWCNT coated with a polystyrene−based polymer. This kind of coating could be useful to decrease MWCNT toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Direct noninvasive visualization of the coronary vessel wall may enhance risk stratification by quantifying subclinical coronary atherosclerotic plaque burden. We sought to evaluate high-resolution black-blood 3D cardiovascular magnetic resonance (CMR) imaging for in vivo visualization of the proximal coronary artery vessel wall. METHODS AND RESULTS: Twelve adult subjects, including 6 clinically healthy subjects and 6 patients with nonsignificant coronary artery disease (10% to 50% x-ray angiographic diameter reduction) were studied with the use of a commercial 1.5 Tesla CMR scanner. Free-breathing 3D coronary vessel wall imaging was performed along the major axis of the right coronary artery with isotropic spatial resolution (1.0x1.0x1.0 mm(3)) with the use of a black-blood spiral image acquisition. The proximal vessel wall thickness and luminal diameter were objectively determined with an automated edge detection tool. The 3D CMR vessel wall scans allowed for visualization of the contiguous proximal right coronary artery in all subjects. Both mean vessel wall thickness (1.7+/-0.3 versus 1.0+/-0.2 mm) and wall area (25.4+/-6.9 versus 11.5+/-5.2 mm(2)) were significantly increased in the patients compared with the healthy subjects (both P<0.01). The lumen diameter (3.6+/-0.7 versus 3.4+/-0.5 mm, P=0.47) and lumen area (8.9+/-3.4 versus 7.9+/-3.5 mm(2), P=0.47) were similar in both groups. CONCLUSIONS: Free-breathing 3D black-blood coronary CMR with isotropic resolution identified an increased coronary vessel wall thickness with preservation of lumen size in patients with nonsignificant coronary artery disease, consistent with a "Glagov-type" outward arterial remodeling. This novel approach has the potential to quantify subclinical disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The worldwide prevalence of smoking has been estimated at about 50% in men, and 10% in women, with larger variations among different populations studied. Smoking has been shown to affect many organ systems resulting in severe morbidity and increased mortality. In addition, smoking has been identified as a predictor of ten-year fracture risk in men and women, largely independent of an individual's bone mineral density. This finding has eventually lead to incorporation of this risk factor into FRAX®, an algorithm that has been developed to calculate an individual's ten-year fracture risk. However, only little, or conflicting data is available on a possible association between smoking dose, duration, length of time after cessation, type of tobacco and fracture risk, limiting this risk factor's applicability in the context of FRAX®.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: The time course of atherosclerosis burden in distinct vascular territories remains poorly understood. We longitudinally evaluated the natural history of atherosclerotic progression in two different arterial territories using high spatial resolution magnetic resonance imaging (HR-MRI), a powerful, safe, and non-invasive tool. METHODS AND RESULTS: We prospectively studied a cohort of 30 patients (mean age 68.3, n = 9 females) with high Framingham general cardiovascular disease 10-year risk score (29.5%) and standard medical therapy with mild-to-moderate atherosclerosis intra-individually at the level of both carotid and femoral arteries. A total of 178 HR-MRI studies of carotid and femoral arteries performed at baseline and at 1- and 2-year follow-up were evaluated in consensus reading by two experienced readers for lumen area (LA), total vessel area (TVA), vessel wall area (VWA = TVA - LA), and normalized wall area index (NWI = VWA/TVA). At the carotid level, LA decreased (-3.19%/year, P = 0.018), VWA increased (+3.83%/year, P = 0.019), and TVA remained unchanged. At the femoral level, LA remained unchanged, VWA and TVA increased (+5.23%/year and +3.11%/year, both P < 0.01), and NWI increased for both carotid and femoral arteries (+2.28%/year, P = 0.01, and +1.8%/year, P = 0.033). CONCLUSION: The atherosclerotic burden increased significantly in both carotid and femoral arteries. However, carotid plaque progression was associated with negative remodelling, whereas the increase in femoral plaque burden was compensated by positive remodelling. This finding could be related to anatomic and flow differences and/or to the distinct degree of obstruction in the two arterial territories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The International Society for Clinical Densitometry (ISCD) and the International Osteoporosis Foundation (IOF) convened the FRAX(®) Position Development Conference (PDC) in Bucharest, Romania, on November 14, 2010, following a two-day joint meeting of the ISCD and IOF on the "Interpretation and Use of FRAX(®) in Clinical Practice." These three days of critical discussion and debate, led by a panel of international experts from the ISCD, IOF and dedicated task forces, have clarified a number of important issues pertaining to the interpretation and implementation of FRAX(®) in clinical practice. The Official Positions resulting from the PDC are intended to enhance the quality and clinical utility of fracture risk assessment worldwide. Since the field of skeletal assessment is still evolving rapidly, some clinically important issues addressed at the PDCs are not associated with robust medical evidence. Accordingly, some Official Positions are based largely on expert opinion. Despite limitations inherent in such a process, the ISCD and IOF believe it is important to provide clinicians and technologists with the best distillation of current knowledge in the discipline of bone densitometry and provide an important focus for the scientific community to consider. This report describes the methodology and results of the ISCD-IOF PDC dedicated to FRAX(®).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FRAX(®) is a fracture risk assessment algorithm developed by the World Health Organization in cooperation with other medical organizations and societies. Using easily available clinical information and femoral neck bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), when available, FRAX(®) is used to predict the 10-year probability of hip fracture and major osteoporotic fracture. These values may be included in country specific guidelines to aid clinicians in determining when fracture risk is sufficiently high that the patient is likely to benefit from pharmacological therapy to reduce that risk. Since the introduction of FRAX(®) into clinical practice, many practical clinical questions have arisen regarding its use. To address such questions, the International Society for Clinical Densitometry (ISCD) and International Osteoporosis Foundations (IOF) assigned task forces to review the best available medical evidence and make recommendations for optimal use of FRAX(®) in clinical practice. Questions were identified and divided into three general categories. A task force was assigned to investigating the medical evidence in each category and developing clinically useful recommendations. The BMD Task Force addressed issues that included the potential use of skeletal sites other than the femoral neck, the use of technologies other than DXA, and the deletion or addition of clinical data for FRAX(®) input. The evidence and recommendations were presented to a panel of experts at the ISCD-IOF FRAX(®) Position Development Conference, resulting in the development of ISCD-IOF Official Positions addressing FRAX(®)-related issues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Chest wall resection and reconstruction can be performed with minimal mortality and excellent functional and cosmetic results using synthetic meshes, methylmethacrylate, or other substitutes. However, these techniques are less easily applicable if chest wall resections have to be performed for infections. METHODS: We report a novel technique for this purpose using a modified latissimus dorsi flap harvested in continuity with the thoracolumbar fascia. The vascularized fascia was sutured into the chest wall defect, providing a stable base for the muscular component of the flap. Three patients requiring large full-thickness resections of the anterolateral chest wall for chronic infections were treated accordingly, two presenting with chronic radionecrosis and osteomyelitis and one with chest wall invasion by pulmonary aspergillosis. RESULTS: There were no intraoperative or postoperative complications and immediate extubation was possible in all 3 patients without the need for postoperative ventilation or tracheotomy. Healing of the infected chest wall was observed in all 3 patients. Postoperative cinemagnetic resonance imaging revealed concordant movements of the replaced segments without evidence of paradoxical motion during inspiration and expiration. CONCLUSIONS: This technique is easy and safe. It allows a stable and satisfactory reconstruction after large anterolateral full-thickness chest wall resections of infected, previously irradiated tissues, using only well-vascularized autologous tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rheumatoid arthritis is the only secondary cause of osteoporosis that is considered independent of bone density in the FRAX(®) algorithm. Although input for rheumatoid arthritis in FRAX(®) is a dichotomous variable, intuitively, one would expect that more severe or active disease would be associated with a greater risk for fracture. We reviewed the literature to determine if specific disease parameters or medication use could be used to better characterize fracture risk in individuals with rheumatoid arthritis. Although many studies document a correlation between various parameters of disease activity or severity and decreased bone density, fewer have associated these variables with fracture risk. We reviewed these studies in detail and concluded that disability measures such as HAQ (Health Assessment Questionnaire) and functional class do correlate with clinical fractures but not morphometric vertebral fractures. One large study found a strong correlation with duration of disease and fracture risk but additional studies are needed to confirm this. There was little evidence to correlate other measures of disease such as DAS (disease activity score), VAS (visual analogue scale), acute phase reactants, use of non-glucocorticoid medications and increased fracture risk. We concluded that FRAX(®) calculations may underestimate fracture probability in patients with impaired functional status from rheumatoid arthritis but that this could not be quantified at this time. At this time, other disease measures cannot be used for fracture prediction. However only a few, mostly small studies addressed other disease parameters and further research is needed. Additional questions for future research are suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The objective of this study was to evaluate associations between aortic pulse wave velocity (PWV) and aortic and carotid vessel wall thickness (VWT) using cardiovascular magnetic resonance imaging (MRI) in patients with hypertension as compared with healthy adult volunteers. MATERIALS AND METHODS: Local medical ethics approval was obtained and the participants gave informed consent. Fifteen patients with hypertension (5 men and 10 women; mean [SD] age, 49 [14] years) and 15 age- and sex-matched healthy volunteers were prospectively included and compared. All participants underwent MRI examination for measuring aortic and carotid VWT and aortic PWV with well-validated MRI techniques at 1.5- and 3-T MRI systems: PWV was assessed from velocity-encoded MRI and VWT was assessed by using dual-inversion black-blood gradient-echo imaging techniques. Paired t tests were used for testing differences between the volunteers and the patients and Pearson correlation (r) and univariable and multivariable stepwise linear regression analyses were used to test associations between aortic and carotid arterial wall thickness and stiffness. RESULTS: Mean values for aortic PWV and aortic and carotid VWT (indexed for body surface area [BSA]) were all significantly higher in patients with hypertension as compared with the healthy volunteers (ie, aortic PWV, 7.0 ± 1.4 m/s vs 5.7 ± 1.3 m/s; aortic VWT/BSA, 0.12 ± 0.03 mL/m vs 0.10 ± 0.03 mL/m; carotid VWT/BSA, 0.04 ± 0.01 mL/m vs 0.03 ± 0.01 mL/m; all P < 0.01). Aortic PWV was highly correlated with aortic VWT/BSA (r = 0.76 and P = 0.002 in the patients vs r = 0.63 and P = 0.02 in the volunteers), and in the patients, aortic PWV was moderately correlated with carotid VWT/BSA (r = 0.50; P = 0.04). In the volunteers, correlation between aortic PWV and carotid VWT/BSA was not significant (r = 0.40; P = 0.13). In addition, aortic VWT/BSA was significantly correlated with carotid VWT/BSA, in both the patients (r = 0.60; P = 0.005) and volunteers (r = 0.57; P = 0.007). CONCLUSIONS: In the patients with hypertension and the healthy volunteers, the aortic PWV is associated more strongly with aortic wall thickness than with carotid wall thickness, reflecting site-specific coupling between vascular wall thickness and function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Dual-inversion recovery (DIR) is widely used for magnetic resonance vessel wall imaging. However, optimal contrast may be difficult to obtain and is subject to RR variability. Furthermore, DIR imaging is time-inefficient and multislice acquisitions may lead to prolonged scanning times. Therefore, an extension of phase-sensitive (PS) DIR is proposed for carotid vessel wall imaging. METHODS: The statistical distribution of the phase signal after DIR is probed to segment carotid lumens and suppress their residual blood signal. The proposed PS-DIR technique was characterized over a broad range of inversion times. Multislice imaging was then implemented by interleaving the acquisition of 3 slices after DIR. Quantitative evaluation was then performed in healthy adult subjects and compared with conventional DIR imaging. RESULTS: Single-slice PS-DIR provided effective blood-signal suppression over a wide range of inversion times, enhancing wall-lumen contrast and vessel wall conspicuity for carotid arteries. Multislice PS-DIR imaging with effective blood-signal suppression is enabled. CONCLUSIONS: A variant of the PS-DIR method has successfully been implemented and tested for carotid vessel wall imaging. This technique removes timing constraints related to inversion recovery, enhances wall-lumen contrast, and enables a 3-fold increase in volumetric coverage at no extra cost in scanning time.