121 resultados para variable parameters
Resumo:
Despite the advancement of phylogenetic methods to estimate speciation and extinction rates, their power can be limited under variable rates, in particular for clades with high extinction rates and small number of extant species. Fossil data can provide a powerful alternative source of information to investigate diversification processes. Here, we present PyRate, a computer program to estimate speciation and extinction rates and their temporal dynamics from fossil occurrence data. The rates are inferred in a Bayesian framework and are comparable to those estimated from phylogenetic trees. We describe how PyRate can be used to explore different models of diversification. In addition to the diversification rates, it provides estimates of the parameters of the preservation process (fossilization and sampling) and the times of speciation and extinction of each species in the data set. Moreover, we develop a new birth-death model to correlate the variation of speciation/extinction rates with changes of a continuous trait. Finally, we demonstrate the use of Bayes factors for model selection and show how the posterior estimates of a PyRate analysis can be used to generate calibration densities for Bayesian molecular clock analysis. PyRate is an open-source command-line Python program available at http://sourceforge.net/projects/pyrate/.
Value of sTREM-1, procalcitonin and CRP as laboratory parameters for postmortem diagnosis of sepsis.
Resumo:
OBJECTIVES: Triggering receptor expressed on myeloid cells-1 (TREM-1) was reported to be up-regulated in various inflammatory diseases as well as in bacterial sepsis. Increased cell-surface TREM-1 expression was also shown to result in marked plasma elevation of the soluble form of this molecule (sTREM-1) in patients with bacterial infections. In this study, we investigated sTREM-1, procalcitonin and C-reactive protein in postmortem serum in a series of sepsis-related fatalities and control individuals who underwent medico-legal investigations. sTREM-1 was also measured in pericardial fluid and urine. METHODS: Two study groups were prospectively formed, a sepsis-related fatalities group and a control group. The sepsis-related fatalities group consisted of sixteen forensic autopsy cases. Eight of these had a documented clinical diagnosis of sepsis in vivo. The control group consisted of sixteen forensic autopsy cases with various causes of death. RESULTS: Postmortem serum sTREM-1 concentrations were higher in the sepsis group with a mean value of 173.6 pg/ml in septic cases and 79.2 pg/ml in control individuals. The cutoff value of 90 pg/ml provided the best sensitivity and specificity. Pericardial fluid sTREM-1 values were higher in the septic group, with a mean value of 296.7 pg/ml in septic cases and 100.9 pg/ml in control individuals. The cutoff value of 135 pg/ml provided the best sensitivity and specificity. Mean urine sTREM-1 concentration was 102.9 pg/ml in septic cases and 89.3 pg/ml in control individuals. CONCLUSIONS: Postmortem serum sTREM-1, individually considered, did not provide better sensitivity and specificity than procalcitonin in detecting sepsis. However, simultaneous assessment of procalcitonin and sTREM-1 in postmortem serum can be of help in clarifying contradictory postmortem findings. sTREM-1 determination in pericardial fluid can be an alternative to postmortem serum in those situations in which biochemical analyses are required and blood collected during autopsy proves insufficient.
Resumo:
OBJECTIVE: To determine the means and the reference intervals of the quantitative morphometric parameters of femoroacetabular impingement (FAI) in normal hips with high-resolution computed tomography (CT). METHODS: We prospectively included 94 adult individuals who underwent CT for thoracic, abdominal or urologic pathologies. Patients with a clinical history of hip pathology and/or with osteoarthritis on CT were excluded. We calculated means and 95 % reference intervals for imaging signs of cam-type (alpha angle at 90° and 45° and femoral head-neck offset) and pincer-type impingement (acetabular version angle, lateral centre-edge angle and acetabular index). RESULTS: The 95 % reference interval limits were all far beyond the abnormal thresholds found in the literature for cam-type and to a lesser extent for pincer-type FAI. The upper limits of the reference intervals for the alpha angles (at 90°/45°) were 68°/83° (men) and 69°/84° (women), compared to thresholds from the literature (50°, 55° or 60°). Reference intervals were similar between genders for cam-type parameters, and slightly differed for pincer-type. CONCLUSION: The 95 % reference intervals of morphometric measurements of FAI in asymptomatic hips were beyond the abnormal thresholds, which was especially true for cam-type FAI. Our results suggest the need for redefining the current morphometric parameters used in the diagnosis of FAI. KEY POINTS: ? 95 % reference intervals limits of FAI morphotype were beyond currently defined thresholds. ? Reference intervals of pincer-type morphotype measurements were close to current definitions. ? Reference intervals of cam-type morphotype measurements were far beyond the current definitions. ? Current morphometric definitions of cam-type morphotype should be used with care.
Resumo:
The purpose of this study was to investigate the impact of navigator timing on image quality in navigator-gated and real-time motion-corrected, free-breathing, three-dimensional (3D) coronary MR angiography (MRA) with submillimeter spatial image resolution. Both phantom and in vivo investigations were performed. 3D coronary MRA with real-time navigator technology was applied using variable navigator time delays (time delay between the navigator and imaging sequences) and varying spatial resolutions. Quantitative objective and subjective image quality parameters were assessed. For high-resolution imaging, reduced image quality was found as a function of increasing navigator time delay. Lower spatial resolution coronary MRA showed only minor sensitivity to navigator timing. These findings were consistent among volunteers and phantom experiments. In conclusion, for submillimeter navigator-gated and real-time motion-corrected 3D coronary MRA, shortening the time delay between the navigator and the imaging portion of the sequence becomes increasingly important for improved spatial resolution.
Resumo:
During free walking, gait is automatically adjusted to provide optimal mechanical output and minimal energy expenditure; gait parameters, such as cadence, fluctuate from one stride to the next around average values. It was described that this fluctuation exhibited long-range correlations and fractal-like patterns. In addition, it was suggested that these long-range correlations disappeared if the participant followed the beep of metronome to regulate his or her pace. Until now, these fractal fluctuations were only observed for stride interval, because no technique existed to adequately analyze an extended time of free walking. The aim of the present study was to measure walking speed (WS), step frequency (SF) and step length (SL) with high accuracy (<1 cm) satellite positioning method (global positioning system or GPS) in order to detect long-range correlations in the stride-to-stride fluctuations. Eight participants walked 30 min under free and constrained (metronome) conditions. Under free walking conditions, DFA (detrended fluctuation analysis) and surrogate data tests showed that the fluctuation of WS, SL and SF exhibited a fractal pattern (i.e., scaling exponent alpha: 0.5 < alpha < 1) in a large majority of participants (7/8). Under constrained conditions (metronome), SF fluctuations became significantly anti-correlated (alpha < 0.5) in all participants. However, the scaling exponent of SL and WS was not modified. We conclude that, when the walking pace is controlled by an auditory signal, the feedback loop between the planned movement (at supraspinal level) and the sensory inputs induces a continual shifting of SF around the mean (persistent anti-correlation), but with no effect on the fluctuation dynamics of the other parameters (SL, WS).
Resumo:
We investigated the association of trabecular bone score (TBS) with microarchitecture and mechanical behavior of human lumbar vertebrae. We found that TBS reflects vertebral trabecular microarchitecture and is an independent predictor of vertebral mechanics. However, the addition of TBS to areal BMD (aBMD) did not significantly improve prediction of vertebral strength. INTRODUCTION: The trabecular bone score (TBS) is a gray-level measure of texture using a modified experimental variogram which can be extracted from dual-energy X-ray absorptiometry (DXA) images. The current study aimed to confirm whether TBS is associated with trabecular microarchitecture and mechanics of human lumbar vertebrae, and if its combination with BMD improves prediction of fracture risk. METHODS: Lumbar vertebrae (L3) were harvested fresh from 16 donors. The anteroposterior and lateral bone mineral content (BMC) and areal BMD (aBMD) of the vertebral body were measured using DXA; then, the TBS was extracted using TBS iNsight software (Medimaps SA, France). The trabecular bone volume (Tb.BV/tissue volume, TV), trabecular thickness (Tb.Th), degree of anisotropy, and structure model index (SMI) were measured using microcomputed tomography. Quasi-static uniaxial compressive testing was performed on L3 vertebral bodies to assess failure load and stiffness. RESULTS: The TBS was significantly correlated to Tb.BV/TV and SMI (râeuro0/00=âeuro0/000.58 and -0.62; pâeuro0/00=âeuro0/000.02, 0.01), but not related to BMC and BMD. TBS was significantly correlated with stiffness (râeuro0/00=âeuro0/000.64; pâeuro0/00=âeuro0/000.007), independently of bone mass. Using stepwise multiple regression models, we failed to demonstrate that the combination of BMD and TBS was better at explaining mechanical behavior than either variable alone. However, the combination TBS, Tb.Th, and BMC did perform better than each parameter alone, explaining 79Â % of the variability in stiffness. CONCLUSIONS: In our study, TBS was associated with microarchitecture parameters and with vertebral mechanical behavior, but TBS did not improve prediction of vertebral biomechanical properties in addition to aBMD.
Resumo:
The aim of the present study was to investigate to what extent interstitial lung disease (ILD) in common variable immunodeficiency disorder (CVID)-associated granulomatous disease (GD) is similar to pulmonary sarcoidosis 20 patients with CVID/GD were included in a retrospective study conducted by the Groupe Sarcoïdose Francophone. Medical records were centralised. Patients were compared with 60 controls with sarcoidosis. Clinical examination showed more frequent crackles in patients than controls (45% versus 1.7%, respectively; p<0.001). On thoracic computed tomography scans, nodules (often multiple and with smooth margins), air bronchograms and halo signs were more frequent in patients than controls (80% versus 42%, respectively; p=0.004) as well as bronchiectasis (65% versus 23%, respectively; p<0.001). The micronodule distribution was perilymphatic in 100% of controls and in 42% of patients (p<0.001). Bronchoalveolar lavage analysis showed lower T-cell CD4/CD8 ratios in patients than in controls (mean±sd 1.6±1.1 versus 5.3±4, respectively; p<0.01). On pathological analysis, nodules and consolidations corresponded to granulomatous lesions with or without lymphocytic disorders in most cases. Mortality was higher in patients than controls (30% versus 0%, respectively) and resulted from common variable immunodeficiency complications. ILD in CVID/GD presents a specific clinical picture and evolution that are markedly different from those of sarcoidosis.
Resumo:
PURPOSE: To characterize the clinical, psychophysical, and electrophysiological phenotypes in a five-generation Swiss family with dominantly inherited retinitis pigmentosa caused by a T494M mutation in the Precursor mRNA-Processing factor 3 (PRPF3) gene, and to relate the phenotype to the underlying genetic mutation. METHODS: Eleven affected patients were ascertained for phenotypic and genotypic characterization. Ophthalmologic evaluations included color vision testing, Goldmann perimetry, and digital fundus photography. Some patients had autofluorescence imaging, Optical Coherence Tomography, and ISCEV-standard full-field electroretinography. All affected patients had genetic testing. RESULTS: The age of onset of night blindness and the severity of the progression of the disease varied between members of the family. Some patients reported early onset of night blindness at age three, with subsequent severe deterioration of visual acuity, which was 0.4 in the best eye after their fifties. The second group of patients had a later onset of night blindness, in the mid-twenties, with a milder disease progression and a visual acuity of 0.8 at age 70. Fundus autofluorescence imaging and electrophysiological and visual field abnormalities also showed some degree of varying phenotypes. The autofluorescence imaging showed a large high-density ring bilaterally. Myopia (range: -0.75 to -8) was found in 10/11 affected subjects. Fundus findings showed areas of atrophy along the arcades. A T494M change was found in exon 11 of the PRPF3 gene. The change segregates with the disease in the family. CONCLUSIONS: A mutation in the PRPF3 gene is rare compared to other genes causing autosomal dominant retinitis pigmentosa (ADRP). Although a T494M change has been reported, the family in our study is the first with variable expressivity. Mutations in the PRPF3 gene can cause a variable ADRP phenotype, unlike in the previously described Danish, English, and Japanese families. Our report, based on one of the largest affected pedigree, provides a better understanding as to the phenotype/genotype description of ADRP caused by a PRPF3 mutation.
Resumo:
A tree frog (Hyla arborea L., 1758) metapopulation in western Switzerland was studied during spring 2001. All potential calling ponds in an area of 350 km(2) were searched for tree frog calling males. Twenty-nine out of 111 ponds sheltered between 1 and 250 callers. Most ponds were occupied by less than 12 males. Pond parameters were measured at three different levels using field analysis and a Geographical Information System (GIS). The first level was water chemistry and pond-associated measures. The second level was the surrounding land use in a 30 m buffer around the pond. The third level consisted of landscape indices on a broader scale (up to 2 km). Logistic regression was applied to identify parameters that can predict the presence of calling males in a pond. Response variable was the presence or absence of callers. Four significant parameters allowed us to explain about 40% of the total deviance of the observed occupational pattern. Urbanization around the pond had a highly negative impact on the probability of presence of calling males. Hours of direct sunlight on the pond was positively correlated with callers. Higher water conductivity was associated with a lesser probability of species presence. Finally, the further the closest two-lane road, the higher the probability of callers presence. Our results show that presence or absence of callers is influenced by factors acting at various geographical scales.
Resumo:
OBJECTIVE: When we examined a previously published prospective multi-center clinical trial in which complete denture-wearers were followed over a period of 2 years, we found that about 30% of the variability in the clinical wear data of denture teeth was due to unknown characteristics of the subjects. In the second part of the study, we try to identify which patient- and therapy-related factors may explain some of this variability. METHODS: The clinical wear data of denture teeth at different recall times (6, 12, 18, 24 months) in 89 subjects (at baseline) were correlated with the following parameters, which may all have an influence on the wear of denture teeth: age, gender, bruxism as reported by the subjects, number of prostheses used so far, time since last extraction, smoking, fit of dentures as judged by the subject and the clinician, average denture wearing time and wearing of denture during the night. To evaluate the influence of the different patient- and therapy-related variables, both a univariate analysis (one extra factor to the model) and a multivariate analysis were carried out using linear mixed models with the variable Log mean as the outcome. RESULTS: None of the patient- and therapy-related parameters showed a statistically significant effect on the wear of denture teeth. There was, however, a trend for women to show less wear compared to men and a trend of decreasing wear with increasing age. SIGNIFICANCE: Further research is required to identify the factors which are responsible for the high variability observed between the subjects regarding clinical wear data.
Resumo:
Over the last century, numerous techniques have been developed to analyze the movement of humans while walking and running. The combined use of kinematics and kinetics methods, mainly based on high speed video analysis and forceplate, have permitted a comprehensive description of locomotion process in terms of energetics and biomechanics. While the different phases of a single gait cycle are well understood, there is an increasing interest to know how the neuro-motor system controls gait form stride to stride. Indeed, it was observed that neurodegenerative diseases and aging could impact gait stability and gait parameters steadiness. From both clinical and fundamental research perspectives, there is therefore a need to develop techniques to accurately track gait parameters stride-by-stride over a long period with minimal constraints to patients. In this context, high accuracy satellite positioning can provide an alternative tool to monitor outdoor walking. Indeed, the high-end GPS receivers provide centimeter accuracy positioning with 5-20 Hz sampling rate: this allows the stride-by-stride assessment of a number of basic gait parameters--such as walking speed, step length and step frequency--that can be tracked over several thousand consecutive strides in free-living conditions. Furthermore, long-range correlations and fractal-like pattern was observed in those time series. As compared to other classical methods, GPS seems a promising technology in the field of gait variability analysis. However, relative high complexity and expensiveness--combined with a usability which requires further improvement--remain obstacles to the full development of the GPS technology in human applications.
Resumo:
BACKGROUND: Colonoscopy is generally performed with the patient sedated and receiving analgesics. However, the benefit of the most often used combination of intravenous midazolam and pethidine on patient tolerance and pain and its cardiorespiratory risk have not been fully defined. METHODS: In this double-blind prospective study, 150 outpatients undergoing routine colonoscopy were randomly assigned to receive either (1) low-dose midazolam (35 micrograms/kg) and pethidine (700 micrograms/kg in 48 patients, 500 micrograms/kg in 102 patients), (2) midazolam and placebo pethidine, or (3) pethidine and placebo midazolam. RESULTS: Tolerance (visual analog scale, 0 to 100 points: 0 = excellent; 100 = unbearable) did not improve significantly more in group 1 compared with group 2 (7 points; 95% confidence interval [-2-17]) and group 3 (2 points; 95% confidence interval [-7-12]). Similarly, pain was not significantly improved in group 1 as compared with the other groups. Male gender (p < 0.001) and shorter duration of the procedure (p = 0.004), but not amnesia, were associated with better patient tolerance and less pain. Patient satisfaction was similar in all groups. Oxygen desaturation and hypotension occurred in 33% and 11%, respectively, with a similar frequency in all three groups. CONCLUSIONS: In this study, the combination of low-dose midazolam and pethidine does not improve patient tolerance and lessen pain during colonoscopy as compared with either drug given alone. When applying low-dose midazolam, oxygen desaturation and hypotension do not occur more often after combined use of both drugs. For the individual patient, sedation and analgesia should be based on the endoscopist's clinical judgement.