131 resultados para total bacteria


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Plasma free and urinary metanephrines are recognized biomarkers for the assessment of pheochromocytoma. Plasma total metanephrines with a long half-life may represent another useful biomarker. OBJECTIVE: The aim of this study is to evaluate the diagnostic performances of plasma total metanephrines alone or combined with free metanephrines and fractionated 24-h urinary metanephrines. METHODS: A retrospective, case-control diagnostic test study was conducted between 1999 and 2007 in two university hospitals in Switzerland and two institutions in France. The patients included 46 cases with histologically proven pheochromocytoma, and 181 controls suspected of tumor with negative investigations and 3-year follow-up. None had renal dysfunction. Sensitivity and specificity were compared after expressing each measurement result as a ratio over its upper reference limit, adding the ratios of normetanephrine and metanephrine, and defining cut-off values of 1 or 2 for this sum. RESULTS: Applying a cut-off value of 1, plasma free and total metanephrines and urinary fractionated metanephrines had similar sensitivities of 96% (95% confidence interval, 86-99%), 95% (85-99%), and 95% (84-99%) along with similar specificities of 89% (83-94%), 91% (84-95%), and 86% (80-91%). A cut-off of 2 for the sum of ratios over reference limit improves the specificity, and it can be used for a confirmation test based on another biomarker taken among the three biomarkers. CONCLUSION: All three metanephrine-based tests perform equivalently for diagnosing pheochromocytoma in the absence of renal insufficiency, and can be conveniently associated two by two for confirming/excluding tumor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnostic yield of prosthetic joint-associated infection is hampered by the phenotypic change of bacteria into a sessile and resistant form, also called biofilm. With sonication, adherent bacteria can be dislodged from the prosthesis. Species identification may be difficult because of their variations in phenotypic appearance and biochemical reaction. We have studied the phenotypic, genotypic, and biochemical properties of Escherichia coli variants isolated from a periprosthetic joint infection. The strains were collected from synovial fluid, periprosthetic tissue, and fluid from the explanted and sonicated prosthesis. Isolates from synovial fluid revealed a normal phenotype, whereas a few variants from periprosthetic tissue and all isolates from sonication fluid showed different morphological features (including small-colony variants). All isolates from sonication fluid were beta-galactosidase negative and nonmotile; most were indole negative. Because of further variations in biochemical properties, species identification was false or not possible in 50% of the isolates included in this study. In contrast to normal phenotypes, variants were resistant to aminoglycosides. Typing of the isolates using pulsed-field gel electrophoresis yielded nonidentical banding patterns, but all strains were assigned to the same clonal origin when compared with 207 unrelated E. coli isolates. The bacteria were repeatedly passaged on culture media and reanalyzed. Thereafter, most variants reverted to normal phenotype and regained their motility and certain biochemical properties. In addition, some variants displayed aminoglycoside susceptibility after reversion. Sonication of an explanted prosthesis allows insight into the lifestyle of bacteria in biofilms. Since sonication fluid also reveals dislodged sessile forms, species identification of such variants may be misleading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total energy expenditure (TEE) and patterns of activity were measured by means of a heart rate (HR)-monitoring method in a group of 8-10-year-old children including 13 obese children (weight, 46 +/- 10 kg; fat mass: 32 +/- 9%) and 16 nonobese children (weight, 31 +/- 5 kg; fat mass, 18 +/- 5%). Time for sleeping was not statistically different in the two groups of children (596 +/- 33 vs. 582 +/- 43 min; p = NS). Obese children spent more time doing sedentary activities (400 +/- 129 vs. 295 +/- 127 min; p < 0.05) and less time in nonsedentary activities (449 +/- 126 vs. 563 +/- 135 min; p < 0.05) than nonobese children. Time spent in moderate or vigorous activity-i.e., time spent at a HR between 50% of the maximal O2 uptake (peak VO2) and 70% peak VO2 (moderate) and at a HR > or = 70% peak VO2 (vigorous)-was not statistically different in obese and nonobese children (88 +/- 69 vs. 52 +/- 35 min and 20 +/- 21 vs. 16 +/- 13 min, respectively; p = NS). TEE was significantly higher in the obese group than in the nonobese group (9.46 +/- 1.40 vs. 7.51 +/- 1.67 MJ/day; p < 0.01). The energy expenditure for physical activity (plus thermogenesis) was significantly higher in the obese children (3.98 +/- 1.30 vs. 2.94 +/- 1.39 MJ/day; p < 0.05). The proportion of TEE daily devoted to physical activity (plus thermogenesis) was not significantly different in the two groups, as shown by the ratio between TEE and the postabsorptive metabolic rate (PMR): 1.72 +/- 0.25 obese vs 1.61 +/- 0.28 non-obese. In conclusion, in free-living conditions obese children have a higher TEE than do nonobese children, despite the greater time devoted to sedentary activities. The higher energy cost to perform weight-bearing activities as well as the higher absolute PMR of obese children help explain this apparent paradox.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. Methods: This randomized controlled double-blind study included to date 31 patients: the gait signatures of 12 patients with mobile-bearing were compared to the gait signatures of 19 patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. Results: Better relative differences between pre-operative and post-operative 3 months and 6 months KSS (122% vs 34% at 3 months, 138% vs 36% at 6 months) and KSS function (154% vs 8% at 3 months, 183% vs 42% at 6 months) scores were observed for the fixed-bearing compared to the mobile-bearing. The same better improvements for fixed-bearing were also found with the range of knee angles (Affected side: 31% vs -5% at 3 months, 47% vs 5% at 6 months), (Unaffected side: 16% vs 5% at 3 months, 15% vs 6% at 6 months) and peak swing speeds of shank (Affected side: 18% vs -2% at 3 months, 30% vs 4% at 6 months), (Unaffected side: 8% vs -3% at 3 months, 7% vs 4% at 6 months). Conclusions: A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total ankle replacement remains a less satisfactory solution compared to other joint replacements. The goal of this study was to develop and validate a finite element model of total ankle replacement, for future testing of hypotheses related to clinical issues. To validate the finite element model, an experimental setup was specifically developed and applied on 8 cadaveric tibias. A non-cemented press fit tibial component of a mobile bearing prosthesis was inserted into the tibias. Two extreme anterior and posterior positions of the mobile bearing insert were considered, as well as a centered one. An axial force of 2kN was applied for each insert position. Strains were measured on the bone surface using digital image correlation. Tibias were CT scanned before implantation, after implantation, and after mechanical tests and removal of the prosthesis. The finite element model replicated the experimental setup. The first CT was used to build the geometry and evaluate the mechanical properties of the tibias. The second CT was used to set the implant position. The third CT was used to assess the bone-implant interface conditions. The coefficient of determination (R-squared) between the measured and predicted strains was 0.91. Predicted bone strains were maximal around the implant keel, especially at the anterior and posterior ends. The finite element model presented here is validated for future tests using more physiological loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: Traditionally, pollution risk assessment is based on the measurement of a pollutant's total concentration in a sample. The toxicity of a given pollutant in the environment, however, is tightly linked to its bioavailability, which may differ significantly from the total amount. Physico-chemical and biological parameters strongly influence pollutant fate in terms of leaching, sequestration and biodegradation. Bacterial sensorreporters, which consist of living micro-organisms genetically engineered to produce specific output in response to target chemicals, offer an interesting alternative to monitoring approaches. Bacterial sensor-reporters detect bioavailable and/or bioaccessible compound fractions in samples. Currently, a variety of environmental pollutants can be targeted by specific biosensor-reporters. Although most of such strains are still confined to the lab, several recent reports have demonstrated utility of bacterial sensing-reporting in the field, with method detection limits in the nanomolar range. This review illustrates the general design principles for bacterial sensor-reporters, presents an overview of the existing biosensor-reporter strains with emphasis on organic compound detection. A specific focus throughout is on the concepts of bioavailability and bioaccessibility, and how bacteria-based sensing-reporting systems can help to improve our basic understanding of the different processes at work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infections after total joint arthroplasty are rare but come with severe consequences. Timely, adequate and standardized treatment beginning at the onset of symptoms will have a major impact on the handling of this dreaded complication. In absences of clear guidelines, errors are often committed, with occasionally severe consequences for the patient. In this article, the 10 most frequent errors starting with diagnostics till antibiotic and surgical treatment will be discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: All kinds of blood manipulations aim to increase the total hemoglobin mass (tHb-mass). To establish tHb-mass as an effective screening parameter for detecting blood doping, the knowledge of its normal variation over time is necessary. The aim of the present study, therefore, was to determine the intraindividual variance of tHb-mass in elite athletes during a training year emphasizing off, training, and race seasons at sea level. METHODS: tHb-mass and hemoglobin concentration ([Hb]) were determined in 24 endurance athletes five times during a year and were compared with a control group (n = 6). An analysis of covariance was used to test the effects of training phases, age, gender, competition level, body mass, and training volume. Three error models, based on 1) a total percentage error of measurement, 2) the combination of a typical percentage error (TE) of analytical origin with an absolute SD of biological origin, and 3) between-subject and within-subject variance components as obtained by an analysis of variance, were tested. RESULTS: In addition to the expected influence of performance status, the main results were that the effects of training volume (P = 0.20) and training phases (P = 0.81) on tHb-mass were not significant. We found that within-subject variations mainly have an analytical origin (TE approximately 1.4%) and a very small SD (7.5 g) of biological origin. CONCLUSION: tHb-mass shows very low individual oscillations during a training year (<6%), and these oscillations are below the expected changes in tHb-mass due to Herythropoetin (EPO) application or blood infusion (approximately 10%). The high stability of tHb-mass over a period of 1 year suggests that it should be included in an athlete's biological passport and analyzed by recently developed probabilistic inference techniques that define subject-based reference ranges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-resolution structural information on optimally preserved bacterial cells can be obtained with cryo-electron microscopy of vitreous sections. With the help of this technique, the existence of a periplasmic space between the plasma membrane and the thick peptidoglycan layer of the gram-positive bacteria Bacillus subtilis and Staphylococcus aureus was recently shown. This raises questions about the mode of polymerization of peptidoglycan. In the present study, we report the structure of the cell envelope of three gram-positive bacteria (B. subtilis, Streptococcus gordonii, and Enterococcus gallinarum). In the three cases, a previously undescribed granular layer adjacent to the plasma membrane is found in the periplasmic space. In order to better understand how nascent peptidoglycan is incorporated into the mature peptidoglycan, we investigated cellular regions known to represent the sites of cell wall production. Each of these sites possesses a specific structure. We propose a hypothetic model of peptidoglycan polymerization that accommodates these differences: peptidoglycan precursors could be exported from the cytoplasm to the periplasmic space, where they could diffuse until they would interact with the interface between the granular layer and the thick peptidoglycan layer. They could then polymerize with mature peptidoglycan. We report cytoplasmic structures at the E. gallinarum septum that could be interpreted as cytoskeletal elements driving cell division (FtsZ ring). Although immunoelectron microscopy and fluorescence microscopy studies have demonstrated the septal and cytoplasmic localization of FtsZ, direct visualization of in situ FtsZ filaments has not been obtained in any electron microscopy study of fixed and dehydrated bacteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The ideal local anesthetic regime for femoral nerve block that balances analgesia with mobility after total knee arthroplasty (TKA) remains undefined. QUESTIONS/PURPOSES: We compared two volumes and concentrations of a fixed dose of ropivacaine for continuous femoral nerve block after TKA to a single injection femoral nerve block with ropivacaine to determine (1) time to discharge readiness; (2) early pain scores and analgesic consumption; and (3) functional outcomes, including range of motion and WOMAC scores at the time of recovery. METHODS: Ninety-nine patients were allocated to one of three continuous femoral nerve block groups for this randomized, placebo-controlled, double-blind trial: a high concentration group (ropivacaine 0.2% infusion), a low concentration group (ropivacaine 0.1% infusion), or a placebo infusion group (saline 0.9% infusion). Infusions were discontinued on postoperative Day (POD) 2. The primary outcome was time to discharge readiness. Secondary outcomes included opioid consumption, pain, and functional outcomes. Ninety-three patients completed the study protocol; the study was halted early because of unanticipated changes to pain protocols at the host institution, by which time only 61% of the required number of patients had been enrolled. RESULTS: With the numbers available, the mean time to discharge readiness was not different between groups (high concentration group, 62 hours [95% confidence interval [CI], 51-72 hours]; low concentration group, 73 hours [95% CI, 63-83 hours]; placebo infusion group 65 hours [95% CI, 56-75 hours]; p = 0.27). Patients in the low concentration group consumed significantly less morphine during the period of infusion (POD 1, high concentration group, 56 mg [95% CI, 42-70 mg]; low concentration group, 35 mg [95% CI, 27-43 mg]; placebo infusion group, 48 mg [95% CI, 38-59 mg], p = 0.02; POD 2, high concentration group, 50 mg [95% CI, 41-60 mg]; low concentration group, 33 mg [95% CI, 24-42 mg]; placebo infusion group, 39 mg [95% CI, 30-48 mg], p = 0.04); however, there were no important differences in pain scores or opioid-related side effects with the numbers available. Likewise, there were no important differences in functional outcomes between groups. CONCLUSIONS: Based on this study, which was terminated prematurely before the desired sample size could be achieved, we were unable to demonstrate that varying the concentration and volume of a fixed-dose ropivacaine infusion for continuous femoral nerve block influences time to discharge readiness when compared with a conventional single-injection femoral nerve block after TKA. A low concentration of ropivacaine infusion can reduce postoperative opioid consumption but without any important differences in pain scores, side effects, or functional outcomes. These pilot data may be used to inform the statistical power of future randomized trials. LEVEL OF EVIDENCE: Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.