173 resultados para thermal lens technique.
Resumo:
Peri-insular hemispherotomy is a surgical technique used in the treatment of drug-resistant epilepsy of hemispheric origin. It is based on the exposure of insula and semi-circular sulci, providing access to the lateral ventricle through a supra- and infra-insular window. From inside the ventricle, a parasagittal callosotomy is performed. The basal and medial portion of the frontal lobe is isolated. Projections to the anterior commissure are interrupted at the time of amygdala resection. The hippocampal tail and fimbria-fornix are disrupted posteriorly. We report our experience of 18 cases treated with this approach. More than half of them presented with congenital epilepsy. Neuronavigation was useful in precisely determining the center and extent of the craniotomy, as well as the direction of tractotomies and callosotomy, allowing minimal exposure and blood loss. Intra-operative monitoring by scalp EEG on the contralateral hemisphere was used to follow the progression of the number of interictal spikes during the disconnection procedure. Approximately 90% of patients were in Engel's Class I. We observed one case who presented with transient postoperative neurological deterioration probably due to CSF overdrainage and documented one case of incomplete disconnection in a patient presenting with hemimegalencephaly who needed a second operation. We observed a good correlation between a significant decrease in the number of spikes at the end of the procedure and seizure outcome. Peri-insular hemispherotomy provides a functional disconnection of the hemisphere with minimal resection of cerebral tissue. It is an efficient technique with a low complication rate. Intra-operative EEG monitoring might be used as a predictive factor of completeness of the disconnection and consequently, seizure outcome.
Resumo:
Retained T-tubes are rare complications after biliary surgery. The authors present three cases of retained T-tubes in patients with transplanted liver that could not be removed by a standard manual traction. The authors describe a new simple percutaneous method that allows removal of these T-tubes without complication.
Resumo:
OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.
Resumo:
Some years ago, a parish in Geneva decided to reduce heating costs by insulating its church to make it more energy efficient. Three years after the last renovations, it was observed that the internal surfaces of the naves had already become dusty compared with the customary frequency of 10-12 years. Dust even deposited on various surfaces during religious services. Our investigation showed that nearly all the dust found inside the church may in fact be soot from incense and candle combustion. Incense appears to be a significant source of polycyclic aromatic hydrocarbons. With a mechanical ventilation system and petrol lamps resembling candles the problem can be resolved.
Resumo:
La pose d'un cathéter veineux central peut se faire par plusieurs abords. La connaissance de l'anatomie, du matériel, la maîtrise des détails de la procédure pour chaque type d'abord et une attention particulière à l'asepsie sont des prérequis importants pour limiter les risques de complications et pour donner une information complète et exhaustive au patient. Cet article peut être utilisé comme base pour le développement d'une check-list, utile pour les médecins qui doivent procéder à la pose d'un cathéter veineux central mais qui ne possèdent pas encore une maîtrise du geste. Several approaches exist for central vein catheterization. Mastery of the various steps of this procedure and understanding of the basics of asepsis are critical to prevent any complication. They also built the basis for an exhaustive communication with the patient, to obtain an informed consent. This article can in addition be used to develop a checklist in order to (self-)assess competence in procedural skills
Resumo:
Within the ORAMED project (Optimization of Radiation Protection of Medical Staff) a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe (www.oramed-fp7.eu). The main objective was to obtain a set of standardized data on extremity and eye lens doses for staff involved in interventional radiology and cardiology and to optimize radiation protection. Special attention was given to the measurement of the doses to the eye lenses. In this paper an overview will be given of the measured eye lens doses and the main influence factors for these doses. The measured eye lens doses are extrapolated to annual doses. The extrapolations showed that monitoringof the eye lens should be performed on routine basis.