73 resultados para telelettura consumi idrici Smart Automatic Meter Reading acquedotto Fano (PU) ASET


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new non parametric atlas registration framework, derived from the optical flow model and the active contour theory, applied to automatic subthalamic nucleus (STN) targeting in deep brain stimulation (DBS) surgery. In a previous work, we demonstrated that the STN position can be predicted based on the position of surrounding visible structures, namely the lateral and third ventricles. A STN targeting process can thus be obtained by registering these structures of interest between a brain atlas and the patient image. Here we aim to improve the results of the state of the art targeting methods and at the same time to reduce the computational time. Our simultaneous segmentation and registration model shows mean STN localization errors statistically similar to the most performing registration algorithms tested so far and to the targeting expert's variability. Moreover, the computational time of our registration method is much lower, which is a worthwhile improvement from a clinical point of view.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ligament balance is an important and subjective task performed during total knee arthroplasty (TKA) procedure. For this reason, it is desirable to develop instruments to quantitatively assess the soft-tissue balance since excessive imbalance can accelerate prosthesis wear and lead to early surgical revision. The instrumented distractor proposed in this study can assist surgeons on performing ligament balance by measuring the distraction gap and applied load. Also the device allows the determination of the ligament stiffness which can contribute a better understanding of the intrinsic mechanical behavior of the knee joint. Instrumentation of the device involved the use of hall-sensors for measuring the distractor displacement and strain gauges to transduce the force. The sensors were calibrated and tested to demonstrate their suitability for surgical use. Results show the distraction gap can be measured reliably with 0.1mm accuracy and the distractive loads could be assessed with an accuracy in the range of 4N. These characteristics are consistent with those have been proposed, in this work, for a device that could assist on performing ligament balance while permitting surgeons evaluation based on his experience. Preliminary results from in vitro tests were in accordance with expected stiffness values for medial collateral ligament (MCL) and lateral collateral ligament (LCL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose to evaluate automatic three-dimensional gray-value rigid registration (RR) methods for prostate localization on cone-beam computed tomography (CBCT) scans. In total, 103 CBCT scans of 9 prostate patients have been analyzed. Each one was registered to the planning CT scan using different methods: (a) global RR, (b) pelvis bone structure RR, (c) bone RR refined by local soft-tissue RR using the CT clinical target volume (CTV) expanded with a 1, 3, 5, 8, 10, 12, 15 or 20-mm margin. To evaluate results, a radiation oncologist was asked to manually delineate the CTV on the CBCT scans. The Dice coefficients between each automatic CBCT segmentation - derived from the transformation of the manual CT segmentation - and the manual CBCT segmentation were calculated. Global or bone CT/CBCT RR has been shown to yield insufficient results in average. Local RR with an 8-mm margin around the CTV after bone RR was found to be the best candidate for systematically significantly improving prostate localization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The major source of hemolysis during cardiopulmonary bypass remains the cardiotomy suction and is primarily due to the interaction between air and blood. The Smart suction system involves an automatically controlled aspiration designed to avoid the mixture of blood with air. This study was set-up to compare this recently designed suction system to a Cell Saver system in order to investigate their effects on blood elements during prolonged intrathoracic aspiration. METHODS: In a calf model (n=10; mean weight, 69.3+/-4.5 kg), a standardized hole was created in the right atrium allowing a blood loss of 100 ml/min, with a suction cannula placed into the chest cavity into a fixed position during 6 h. The blood was continuously aspirated either with the Smart suction system (five animals) or the Cell Saver system (five animals). Blood samples were taken hourly for blood cell counts and biochemistry. RESULTS: In the Smart suction group, red cell count, plasma protein and free hemoglobin levels remained stable, while platelet count exhibited a significant drop from the fifth hour onwards (prebypass: 683+/-201*10(9)/l, 5 h: 280+/-142*10(9)/l, P=0.046). In the Cell Saver group, there was a significant drop of the red cell count from the third hour onwards (prebypass: 8.6+/-0.9*10(12)/l, 6 h: 6.3+/-0.4*10(12)/l, P=0.02), of the platelet count from the first hour onwards (prebypass: 630+/-97*10(9)/l, 1 h: 224+/-75*10(9)/l, P<0.01), and of the plasma protein level from the first hour onwards (prebypass: 61.7+/-0.6 g/l, 1 h: 29.3+/-9.1 g/l, P<0.01). CONCLUSIONS: In this experimental set-up, the Smart suction system avoids damage to red cells and affects platelet count less than the Cell Saver system which induces important blood cell destruction, as any suction device mixing air and blood, as well as severe hypoproteinemia with its metabolic, clotting and hemodynamic consequences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Critical reading and careful interpretation of results of the medical literature is a difficult task for primary care physicians. Being aware of common potential pitfalls that may bias results of a study is helpful. Among common pitfalls, odds ratios are often interpreted as relative risks, which overestimate the impact of a risk factor. Randomized controlled trials assessing the effectiveness of a new drug or a new target disease often use surrogate markers instead of clinical events as outcomes. Results of these trials should be considered with caution before using their results for clinical practice. For screening, observational studies often yield potentially biased or conflicting results. As clinical guidelines and expert opinions are often conflicting, primary care physicians should wait for results of large clinical trials in clinical events before changing their practice for screening or new drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To assess the performance of 45F vs. 36F smartcanula in CPB with gravity drainage alone. METHODS: Twenty patients were randomly assigned to two groups receiving for venous drainage a smartcanula which is collapsed over a mandrel for trans-atrial insertion into the inferior vena cava and expanded in situ to either 45F or 36F. RESULTS: Valve replacement/repair was realized in 7/10 and/or CABG in 6/10 for 36F (69+/-13 years) vs. 5/10 and 5/10, respectively, for 45F (63+/-11 years: NS). Body weight and surface area (BSA) were 83+/-9 kg (1.9+/-0.2 m2, max 2.2 m2) for 36F vs. 79+/-6 kg: NS (1.9+/-0.1 m2 (NS), max 2.1 m2) for 45F. Insertion and access orifice diameter (area) was 6 mm and 10 mm (78.5 mm2) for the 36F vs. 6 mm and 13 mm (132 mm2) for the 45F (+69%). Calculated target pump flow (2.4 l/min/m2) was 4.7+/-0.4 l/min for 36F vs. 4.5+/-0.3 l/min for 45F. Achieved pump flow accounted for 5.0+/-0.3 l/min for 36F (8% above target) vs. 4.8+/-0.3 l/min for 45F (8% above target): NS. The water balance during the pump run (clear volume added minus hemofilter and urine output) was 2.2+/-0.3 l for 36F vs. 2.0 l for 45F: NS. CONCLUSION: Due to its 'open' wall (the vena cava provides the seal), its reduced wall thickness (range: 0.0-0.4 mm), and its self-expanding design, the 36F smartcanula requiring a 30F access orifice has sufficient drainage capacity by gravity alone for full CPB in adults with a BSA up to 2.2 mm2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the spatial resolution of a computed tomography (CT) scanner with an automatic approach developed for routine quality controls when varying CT parameters. The methods available to assess the modulation transfer functions (MTF) with the automatic approach were Droege's and the bead point source (BPS) methods. These MTFs were compared with presampled ones obtained using Boone's method. The results show that Droege's method is not accurate in the low-frequency range, whereas the BPS method is highly sensitive to image noise. While both methods are well adapted to routine stability controls, it was shown that they are not able to provide absolute measurements. On the other hand, Boone's method, which is robust with respect to aliasing, more resilient to noise and provides absolute measurements, satisfies the commissioning requirements perfectly. Thus, Boone's method combined with a modified Catphan 600 phantom could be a good solution to assess CT spatial resolution in the different CT planes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The value of earmarks as an efficient means of personal identification is still subject to debate. It has been argued that the field is lacking a firm systematic and structured data basis to help practitioners to form their conclusions. Typically, there is a paucity of research guiding as to the selectivity of the features used in the comparison process between an earmark and reference earprints taken from an individual. This study proposes a system for the automatic comparison of earprints and earmarks, operating without any manual extraction of key-points or manual annotations. For each donor, a model is created using multiple reference prints, hence capturing the donor within source variability. For each comparison between a mark and a model, images are automatically aligned and a proximity score, based on a normalized 2D correlation coefficient, is calculated. Appropriate use of this score allows deriving a likelihood ratio that can be explored under known state of affairs (both in cases where it is known that the mark has been left by the donor that gave the model and conversely in cases when it is established that the mark originates from a different source). To assess the system performance, a first dataset containing 1229 donors elaborated during the FearID research project was used. Based on these data, for mark-to-print comparisons, the system performed with an equal error rate (EER) of 2.3% and about 88% of marks are found in the first 3 positions of a hitlist. When performing print-to-print transactions, results show an equal error rate of 0.5%. The system was then tested using real-case data obtained from police forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MRI has evolved into an important diagnostic technique in medical imaging. However, reliability of the derived diagnosis can be degraded by artifacts, which challenge both radiologists and automatic computer-aided diagnosis. This work proposes a fully-automatic method for measuring image quality of three-dimensional (3D) structural MRI. Quality measures are derived by analyzing the air background of magnitude images and are capable of detecting image degradation from several sources, including bulk motion, residual magnetization from incomplete spoiling, blurring, and ghosting. The method has been validated on 749 3D T(1)-weighted 1.5T and 3T head scans acquired at 36 Alzheimer's Disease Neuroimaging Initiative (ADNI) study sites operating with various software and hardware combinations. Results are compared against qualitative grades assigned by the ADNI quality control center (taken as the reference standard). The derived quality indices are independent of the MRI system used and agree with the reference standard quality ratings with high sensitivity and specificity (>85%). The proposed procedures for quality assessment could be of great value for both research and routine clinical imaging. It could greatly improve workflow through its ability to rule out the need for a repeat scan while the patient is still in the magnet bore.