63 resultados para simultaneous tobit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raltegravir (RAL), maraviroc (MVC), darunavir (DRV), and etravirine (ETV) are new antiretroviral agents with significant potential for drug interactions. This work describes a sensitive and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of plasma drug levels. Single-step extraction of RAL, MVC, DRV, ETV and RTV from plasma (100 microl) is performed by protein precipitation using 600 microl of acetonitrile, after the addition of 100 microl darunavir-d(9) (DRV-d(9)) at 1000 ng/ml in MeOH/H(2)O 50/50 as internal standard (I.S.). The mixture is vortexed, sonicated for 10 min, vortex-mixed again and centrifuged. An aliquot of supernatant (150 microl) is diluted 1:1 with a mixture of 20 mM ammonium acetate/MeOH 40/60 and 10 microl is injected onto a 2.1 x 50 mm Waters Atlantis-dC18 3 microm analytical column. Chromatographic separations are performed using a gradient program with 2 mM ammonium acetate containing 0.1% formic acid and acetonitrile with 0.1% formic acid. Analytes quantification is performed by electrospray ionisation-triple quadrupole mass spectrometry using the selected reaction monitoring detection in the positive mode. The method has been validated over the clinically relevant concentrations ranging from 12.5 to 5000 ng/ml, 2.5 to 1000 ng/ml, 25 to 10,000 ng/ml, 10 to 4000 ng/ml, and 5 to 2000 ng/ml for RAL, MRV, DRV, ETV and RTV, respectively. The extraction recovery for all antiretroviral drugs is always above 91%. The method is precise, with mean inter-day CV% within 5.1-9.8%, and accurate (range of inter-day deviation from nominal values -3.3 to +5.1%). In addition our method enables the simultaneous assessment of raltegravir-glucuronide. This is the first analytical method allowing the simultaneous assay of antiretroviral agents targeted to four different steps of HIV replication. The proposed method is suitable for the Therapeutic Drug Monitoring Service of these new regimen combinations administered as salvage therapy to patients having experienced treatment failure, and for whom exposure, tolerance and adherence assessments are critical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because of the large variability in the pharmacokinetics of anti-HIV drugs, therapeutic drug monitoring in patients may contribute to optimize the overall efficacy and safety of antiretroviral therapy. An LC-MS/MS method for the simultaneous assay in plasma of the novel antiretroviral agents rilpivirine (RPV) and elvitegravir (EVG) has been developed to that endeavor. Plasma samples (100 μL) extraction is performed by protein precipitation with acetonitrile, and the supernatant is subsequently diluted 1:1 with 20-mM ammonium acetate/MeOH 50:50. After reverse-phase chromatography, quantification of RPV and EVG, using matrix-matched calibration samples, is performed by electrospray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The stable isotopic-labeled compounds RPV-(13) C6 and EVG-D6 were used as internal standards. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<6.4%), as well as EVG and RPV short and long-term stability in plasma. Calibration curves were validated over the clinically relevant concentrations ranging from 5 to 2500 ng/ml for RPV and from 50 to 5000 ng/ml for EVG. The method is precise (inter-day CV%: 3-6.3%) and accurate (3.8-7.2%). Plasma samples were found to be stable (<15%) in all considered conditions (RT/48 h, +4°C/48 h, -20°C/3 months and 60°C/1 h). Selected metabolite profiles analysis in patients' samples revealed the presence of EVG glucuronide, that was well separated from parent EVG, allowing to exclude potential interferences through the in-source dissociation of glucuronide to parent drug. This new, rapid and robust LCMS/MS assay for the simultaneous quantification of plasma concentrations of these two major new anti-HIV drugs EVG and RPV offers an efficient analytical tool for clinical pharmacokinetics studies and routine therapeutic drug monitoring service. Copyright © 2013 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gas chromatography-mass spectrometry method is presented which allows the simultaneous determination of the plasma concentrations of the selective serotonin reuptake inhibitors citalopram, paroxetine, sertraline, and their pharmacologically active N-demethylated metabolites (desmethylcitalopram, didesmethylcitalopram, and desmethylsertraline) after derivatization with the reagent N-methyl-bis(trifluoroacetamide). No interferences from endogenous compounds are observed following the extraction of plasma samples from six different human subjects. The standard curves are linear over a working range of 10-500 ng/mL for citalopram, 10-300 ng/mL for desmethylcitalopram, 5-60 ng/mL for didesmethylcitalopram, 20-400 ng/mL for sertraline and desmethylsertraline, and 10-200 ng/mL for paroxetine. Recoveries measured at three concentrations range from 81 to 118% for the tertiary amines (citalopram and the internal standard methylmaprotiline), 73 to 95% for the secondary amines (desmethylcitalopram, paroxetine and sertraline), and 39 to 66% for the primary amines (didesmethylcitalopram and desmethylsertraline). Intra- and interday coefficients of variation determined at three concentrations range from 3 to 11% for citalopram and its metabolites, 4 to 15% for paroxetine, and 5 to 13% for sertraline and desmethylsertraline. The limits of quantitation of the method are 2 ng/mL for citalopram and paroxetine, 1 ng/mL for sertraline, and 0.5 ng/mL for desmethylcitalopram, didesmethylcitalopram, and desmethylsertraline. No interferences are noted from 20 other psychotropic drugs. This sensitive and specific method can be used for single-dose pharmacokinetics. It is also useful for therapeutic drug monitoring of these three drugs and could possibly be adapted for the quantitation of the two other selective serotonin reuptake inhibitors on the market, namely fluoxetine and fluvoxamine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Knowledge of cerebral blood flow (CBF) alterations in cases of acute stroke could be valuable in the early management of these cases. Among imaging techniques affording evaluation of cerebral perfusion, perfusion CT studies involve sequential acquisition of cerebral CT sections obtained in an axial mode during the IV administration of iodinated contrast material. They are thus very easy to perform in emergency settings. Perfusion CT values of CBF have proved to be accurate in animals, and perfusion CT affords plausible values in humans. The purpose of this study was to validate perfusion CT studies of CBF by comparison with the results provided by stable xenon CT, which have been reported to be accurate, and to evaluate acquisition and processing modalities of CT data, notably the possible deconvolution methods and the selection of the reference artery. METHODS: Twelve stable xenon CT and perfusion CT cerebral examinations were performed within an interval of a few minutes in patients with various cerebrovascular diseases. CBF maps were obtained from perfusion CT data by deconvolution using singular value decomposition and least mean square methods. The CBF were compared with the stable xenon CT results in multiple regions of interest through linear regression analysis and bilateral t tests for matched variables. RESULTS: Linear regression analysis showed good correlation between perfusion CT and stable xenon CT CBF values (singular value decomposition method: R(2) = 0.79, slope = 0.87; least mean square method: R(2) = 0.67, slope = 0.83). Bilateral t tests for matched variables did not identify a significant difference between the two imaging methods (P >.1). Both deconvolution methods were equivalent (P >.1). The choice of the reference artery is a major concern and has a strong influence on the final perfusion CT CBF map. CONCLUSION: Perfusion CT studies of CBF achieved with adequate acquisition parameters and processing lead to accurate and reliable results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In order to provide a cost-effective tool to analyse pharmacogenetic markers in malaria treatment, DNA microarray technology was compared with sequencing of polymerase chain reaction (PCR) fragments to detect single nucleotide polymorphisms (SNPs) in a larger number of samples. Methods: The microarray was developed to affordably generate SNP data of genes encoding the human cytochrome P450 enzyme family (CYP) and N-acetyltransferase-2 (NAT2) involved in antimalarial drug metabolisms and with known polymorphisms, i.e. CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP3A4, CYP3A5, and NAT2. Results: For some SNPs, i.e. CYP2A6*2, CYP2B6*5, CYP2C8*3, CYP2C9*3/*5, CYP2C19*3, CYP2D6*4 and NAT2*6/*7/*14, agreement between both techniques ranged from substantial to almost perfect (kappa index between 0.61 and 1.00), whilst for other SNPs a large variability from slight to substantial agreement (kappa index between 0.39 and 1.00) was found, e. g. CYP2D6*17 (2850C>T), CYP3A4*1B and CYP3A5*3. Conclusion: The major limit of the microarray technology for this purpose was lack of robustness and with a large number of missing data or with incorrect specificity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stroma mediated wound healing signals may share similarities with the ones produced by tumor's microenvironment and their modulation may impact tumor response to the various anti-cancer treatments including radiation therapy. Therefore we conducted this study, to assess the crosstalk between stromal and carcinoma cells in response to radiotherapy by genetic modulation of the stroma and irradiation. We found that fibroblasts irrespective of their RhoB status do not modulate intrinsic radiosensitivity of TC-1 but produce diffusible factors able to modify tumor cell fate. Then we found that Wt and RhoB deficient fibroblasts stimulated TC-1 migration through distinct mechanisms which are TGF-β1 and MMP-mediated respectively. Lastly, we found that simultaneous irradiation of fibroblasts and TC-1 abrogated the pro-migratory phenotype by repression of TGF-β and MMP secretion. This last result is highly relevant to the clinical situation and suggests that conversely to, the current view; irradiated stroma would not enhance carcinoma migration and could be manipulated to promote anti-tumor immune response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study investigated patterns of the simultaneous use of alcohol, tobacco and cannabis among young polydrug users, and whether use of one substance might be a cue for use of another and associations with the severity of substance dependence. Methods: The study focused on 3 subsamples from the ongoing Swiss Cohort Study on Substance Use Risk Factors (C-SURF, N=5,990). It used 12 months of data on alcohol/tobacco co-users, alcohol/cannabis co-users and tobacco/cannabis co-users (N=2,660, 1,755 and 1,460 respectively. Simultaneous use, numbers of symptoms of substance dependence, and hazardous use of alcohol, tobacco and cannabis were assessed. The effect of simultaneous polydrug use (SPU) on the numbers of symptoms of substance dependence was tested using analysis of variance. Results: Polydrug use was most common as SPU, and less common as non/occasional SPU. Moreover, when participants started to use one substance while using another, the severity of substance dependence was more strongly associated with the triggered substance than with cue. Conclusions: This study highlights the necessity to take SPU into account. First, SPU rather than separate drug use was the most common pattern for polydrug users. Second, frequent SPU was associated with increased numbers of symptoms of substance dependence compared to non/occasional SPU. Furthermore, SPU may reveal the severity of substance use dependence, when substance use is triggered by a cue substance. For these reasons, SPU should be a serious cause for concern for prevention and intervention purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The enhanced functional sensitivity offered by ultra-high field imaging may significantly benefit simultaneous EEG-fMRI studies, but the concurrent increases in artifact contamination can strongly compromise EEG data quality. In the present study, we focus on EEG artifacts created by head motion in the static B0 field. A novel approach for motion artifact detection is proposed, based on a simple modification of a commercial EEG cap, in which four electrodes are non-permanently adapted to record only magnetic induction effects. Simultaneous EEG-fMRI data were acquired with this setup, at 7T, from healthy volunteers undergoing a reversing-checkerboard visual stimulation paradigm. Data analysis assisted by the motion sensors revealed that, after gradient artifact correction, EEG signal variance was largely dominated by pulse artifacts (81-93%), but contributions from spontaneous motion (4-13%) were still comparable to or even larger than those of actual neuronal activity (3-9%). Multiple approaches were tested to determine the most effective procedure for denoising EEG data incorporating motion sensor information. Optimal results were obtained by applying an initial pulse artifact correction step (AAS-based), followed by motion artifact correction (based on the motion sensors) and ICA denoising. On average, motion artifact correction (after AAS) yielded a 61% reduction in signal power and a 62% increase in VEP trial-by-trial consistency. Combined with ICA, these improvements rose to a 74% power reduction and an 86% increase in trial consistency. Overall, the improvements achieved were well appreciable at single-subject and single-trial levels, and set an encouraging quality mark for simultaneous EEG-fMRI at ultra-high field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To-date, there has been no effective chiral capillary electrophoresis-mass spectrometry (CE-MS) method reported for the simultaneous enantioseparation of the antidepressant drug, venlafaxine (VX) and its structurally-similar major metabolite, O-desmethylvenlafaxine (O-DVX). This is mainly due to the difficulty of identifying MS compatible chiral selector, which could provide both high enantioselectivity and sensitive MS detection. In this work, poly-sodium N-undecenoyl-L,L-leucylalaninate (poly-L,L-SULA) was employed as a chiral selector after screening several dipeptide polymeric chiral surfactants. Baseline separation of both O-DVX and VX enantiomers was achieved in 15min after optimizing the buffer pH, poly-L,L-SULA concentration, nebulizer pressure and separation voltage. Calibration curves in spiked plasma (recoveries higher than 80%) were linear over the concentration range 150-5000ng/mL for both VX and O-DVX. The limit of detection (LOD) was found to be as low as 30ng/mL and 21ng/mL for O-DVX and VX, respectively. This method was successfully applied to measure the plasma concentrations of human volunteers receiving VX or O-DVX orally when co-administered without and with indinivar therapy. The results suggest that micellar electrokinetic chromatography electrospray ionization-tandem mass spectrometry (MEKC-ESI-MS/MS) is an effective low cost alternative technique for the pharmacokinetics and pharmacodynamics studies of both O-DVX and VX enantiomers. The technique has potential to identify drug-drug interaction involving VX and O-DVX enantiomers while administering indinivar therapy.