93 resultados para simulation-optimization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article we present a novel approach for diffusion MRI global tractography. Our formulation models the signal in each voxel as a linear combination of fiber-tract basis func- tions, which consist of a comprehensive set of plausible fiber tracts that are locally compatible with the measured MR signal. This large dictionary of candidate fibers is directly estimated from the data and, subsequently, efficient convex optimization techniques are used for recovering the smallest subset globally best fitting the measured signal. Experimen- tal results conducted on a realistic phantom demonstrate that our approach significantly reduces the computational cost of global tractography while still attaining a reconstruction quality at least as good as the state-of-the-art global methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An active strain formulation for orthotropic constitutive laws arising in cardiac mechanics modeling is introduced and studied. The passive mechanical properties of the tissue are described by the Holzapfel-Ogden relation. In the active strain formulation, the Euler-Lagrange equations for minimizing the total energy are written in terms of active and passive deformation factors, where the active part is assumed to depend, at the cell level, on the electrodynamics and on the specific orientation of the cardiac cells. The well-posedness of the linear system derived from a generic Newton iteration of the original problem is analyzed and different mechanical activation functions are considered. In addition, the active strain formulation is compared with the classical active stress formulation from both numerical and modeling perspectives. Taylor-Hood and MINI finite elements are employed to discretize the mechanical problem. The results of several numerical experiments show that the proposed formulation is mathematically consistent and is able to represent the main key features of the phenomenon, while allowing savings in computational costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A basic prerequisite for in vivo X-ray imaging of the lung is the exact determination of radiation dose. Achieving resolutions of the order of micrometres may become particularly challenging owing to increased dose, which in the worst case can be lethal for the imaged animal model. A framework for linking image quality to radiation dose in order to optimize experimental parameters with respect to dose reduction is presented. The approach may find application for current and future in vivo studies to facilitate proper experiment planning and radiation risk assessment on the one hand and exploit imaging capabilities on the other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Risks of significant infant drug exposure through human milk arepoorly defined due to lack of large-scale PK data. We propose to useBayesian approach based on population PK (popPK)-guided modelingand simulation for risk prediction. As a proof-of-principle study, weexploited fluoxetine milk concentration data from 25 women. popPKparameters including milk-to-plasma ratio (MP ratio) were estimatedfrom the best model. The dose of fluoxetine the breastfed infant wouldreceive through mother's milk, and infant plasma concentrations wereestimated from 1000 simulated mother-infant pairs, using randomassignment of feeding times and milk volume. A conservative estimateof CYP2D6 activity of 20% of the allometrically-adjusted adult valuewas assumed. Derived model parameters, including MP ratio were consistentwith those reported in the literature. Visual predictive check andother model diagnostics showed no signs of model misspecifications.The model simulation predicted that infant exposure levels to fluoxetinevia mother's milk were below 10% of weight-adjusted maternal therapeuticdoses in >99% of simulated infants. Predicted median ratio ofinfant-mother serum levels at steady state was 0.093 (range 0.033-0.31),consistent with literature reported values (mean=0.07; range 0-0.59).Predicted incidence of relatively high infant-mother ratio (>0.2) ofsteady-state serum fluoxetine concentrations was <1.3%. Overall, ourpredictions are consistent with clinical observations. Our approach maybe valid for other drugs, allowing in silico prediction of infant drugexposure risks through human milk. We will discuss application of thisapproach to another drug used in lactating women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Risks of significant infant drug exposurethrough breastmilk are poorly defined for many drugs, and largescalepopulation data are lacking. We used population pharmacokinetics(PK) modeling to predict fluoxetine exposure levels ofinfants via mother's milk in a simulated population of 1000 motherinfantpairs.METHODS: Using our original data on fluoxetine PK of 25breastfeeding women, a population PK model was developed withNONMEM and parameters, including milk concentrations, wereestimated. An exponential distribution model was used to account forindividual variation. Simulation random and distribution-constrainedassignment of doses, dosing time, feeding intervals and milk volumewas conducted to generate 1000 mother-infant pairs with characteristicssuch as the steady-state serum concentrations (Css) and infantdose relative to the maternal weight-adjusted dose (relative infantdose: RID). Full bioavailability and a conservative point estimate of1-month-old infant CYP2D6 activity to be 20% of the adult value(adjusted by weigth) according to a recent study, were assumed forinfant Css calculations.RESULTS: A linear 2-compartment model was selected as thebest model. Derived parameters, including milk-to-plasma ratios(mean: 0.66; SD: 0.34; range, 0 - 1.1) were consistent with the valuesreported in the literature. The estimated RID was below 10% in >95%of infants. The model predicted median infant-mother Css ratio was0.096 (range 0.035 - 0.25); literature reported mean was 0.07 (range0-0.59). Moreover, the predicted incidence of infant-mother Css ratioof >0.2 was less than 1%.CONCLUSION: Our in silico model prediction is consistent withclinical observations, suggesting that substantial systemic fluoxetineexposure in infants through human milk is rare, but further analysisshould include active metabolites. Our approach may be valid forother drugs. [supported by CIHR and Swiss National Science Foundation(SNSF)]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumor Endothelial Marker-1 (TEM1/CD248) is a tumor vascular marker with high therapeutic and diagnostic potentials. Immuno-imaging with TEM1-specific antibodies can help to detect cancerous lesions, monitor tumor responses, and select patients that are most likely to benefit from TEM1-targeted therapies. In particular, near infrared(NIR) optical imaging with biomarker-specific antibodies can provide real-time, tomographic information without exposing the subjects to radioactivity. To maximize the theranostic potential of TEM1, we developed a panel of all human, multivalent Fc-fusion proteins based on a previously identified single chain antibody (scFv78) that recognizes both human and mouse TEM1. By characterizing avidity, stability, and pharmacokinectics, we identified one fusion protein, 78Fc, with desirable characteristics for immuno-imaging applications. The biodistribution of radiolabeled 78Fc showed that this antibody had minimal binding to normal organs, which have low expression of TEM1. Next, we developed a 78Fc-based tracer and tested its performance in different TEM1-expressing mouse models. The NIR imaging and tomography results suggest that the 78Fc-NIR tracer performs well in distinguishing mouse- or human-TEM1 expressing tumor grafts from normal organs and control grafts in vivo. From these results we conclude that further development and optimization of 78Fc as a TEM1-targeted imaging agent for use in clinical settings is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of CT applications might become a public health problem if no effort is made on the justification and the optimisation of the examinations. This paper presents some hints to assure that the risk-benefit compromise remains in favour of the patient, especially when one deals with the examinations of young patients. In this context a particular attention has to be made on the justification of the examination. When performing the acquisition one needs to optimise the extension of the volume investigated together with the number of acquisition sequences used. Finally, the use of automatic exposure systems, now available on all the units, and the use of the Diagnostic Reference Levels (DRL) should allow help radiologists to control the exposure of their patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le modèle développé à l'Institut universitaire de médecine sociale et préventive de Lausanne utilise un programme informatique pour simuler les mouvements d'entrées et de sorties des hôpitaux de soins généraux. Cette simulation se fonde sur les données récoltées de routine dans les hôpitaux; elle tient notamment compte de certaines variations journalières et saisonnières, du nombre d'entrées, ainsi que du "Case-Mix" de l'hôpital, c'est-à-dire de la répartition des cas selon les groupes cliniques et l'âge des patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Streptomycin, as other aminoglycosides, exhibits concentration-dependent bacterial killing but has a narrow therapeutic window. It is primarily eliminated unchanged by the kidneys. Data and dosing information to achieve a safe regimen in patients with chronic renal failure undergoing hemodialysis (HD) are scarce. Although main adverse reactions are related to prolonged, elevated serum concentrations, literature recommendation is to administer streptomycin after each HD. Patients (or Materials) and Methods: We report the case of a patient with end-stage renal failure, undergoing HD, who was successfully treated with streptomycin for gentamicin-resistant Enterococcus faecalis bacteremia with prosthetic arteriovenous fistula infection. Streptomycin was administered intravenously 7.5 mg/kg, 3 hours before each dialysis (3 times a week) during 6 weeks in combination with amoxicillin. Streptomycin plasma levels were monitored with repeated blood sampling before, after, and between HD sessions. A 2-compartment model was used to reconstruct the concentration time profile over days on and off HD. Results: Streptomycin trough plasma-concentration was 2.8 mg/L. It peaked to 21.4 mg/L 30 minutes after intravenous administration, decreased to 18.2 mg/L immediately before HD, and dropped to 4.5 mg/L at the end of a 4-hour HD session. Plasma level increased again to 5.7 mg/L 2 hours after the end of HD and was 2.8 mg/L 48 hours later, before the next administration and HD. The pharmacokinetics of streptomycin was best described with a 2-compartment model. The computer simulation fitted fairly well to the observed concentrations during or between HD sessions. Redistribution between the 2 compartments after the end of HD reproduced the rebound of plasma concentrations after HD. No significant toxicity was observed during treatment. The outcome of the infection was favorable, and no sign of relapse was observed after a follow-up of 3 months. Conclusion: Streptomycin administration of 7.5 mg/kg 3 hours before HD sessions in a patient with end-stage renal failure resulted in an effective and safe dosing regimen. Monitoring plasma levels along with pharmacokinetic simulation document the suitability of this dosing scheme, which should replace current dosage recommendations for streptomycin in HD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Following the introduction of single-metal deposition (SMD), a simplified fingermark detection technique based on multimetal deposition, optimization studies were conducted. The different parameters of the original formula were tested and the results were evaluated based on the contrast and overall aspect of the enhanced fingermarks. The new formula for SMD was found based on the most optimized parameters. Interestingly, it was found that important variations from the base parameters did not significantly affect the outcome of the enhancement, thus demonstrating that SMD is a very robust technique. Finally, a comparison of the optimized SMD with multi-metal deposition (MMD) was carried out on different surfaces. It was demonstrated that SMD produces comparable results to MMD, thus validating the technique.