55 resultados para practical applicability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is currently a lack of guidance on methodology and special considerations for transitioning patients from oxcarbazepine (OXC) or carbamazepine (CBZ) to eslicarbazepine acetate (ESL), if deemed clinically necessary. An advisory panel of epilepsy experts was convened to share their experience on the use of adjunctive ESL in clinical practice and to provide practical recommendations to help address this gap. When changing over from OXC to ESL, an OXC:ESL dose ratio of 1:1 should be employed to calculate the ESL target dose, and the changeover can take place overnight. No changes to comedication are required. Since CBZ has a different mechanism of action to ESL and is a stronger inducer of cytochrome P450 (CYP) enzymes, the transitioning of patients from CBZ to ESL requires careful consideration on a patient-by-patient basis. In general, a CBZ:ESL dose ratio of 1:1.3 should be employed to calculate the ESL target dose, and patients should be transitioned over a minimum period of 1-2weeks. Special considerations include adjustment of titration schedule and target dose in elderly patients and those with hepatic or renal impairment and potential adjustment of comedications metabolized by CYP enzymes. In summary, due to structural distinctions between ESL, OXC, and CBZ, which affect mechanism of action and tolerability, there are clinical situations in which it may be appropriate to consider transitioning patients from OXC or CBZ to ESL. Changing patients over from OXC to ESL is generally more straightforward than transitioning patients from CBZ to ESL, which requires careful consideration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transarterial radioembolization consist in delivering small particles loaded with Yttrium90, a pure beta emitter, in order to treat primary and secondary liver tumors. This treatment needs precaution since inadequate delivery of these beads can lead to severe complications. Moreover, a precise radiation dosing is crucial to achieve a good clinical success and to avoid complications such as radioembolization-induced liver disease. This review describes all the precautions and highlights clinical and technical considerations that need to be taken to avoid complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we present results of studies conducted by the Research Unit of Legal Psychiatry and Psychology of Lausanne about risk assessment and protective factors in the evaluation of violence recidivism. It aims to help experts in considering the relevance and use of tools at their disposal. Particular attention is given to the significance of protective factors and impulsive dimensions, as to the inter-raters process that leads to the final deliberations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The purpose of this study is to validate the Pulvers silhouette showcard as a measure of weight status in a population in the African region. This tool is particularly beneficial when scarce resources do not allow for direct anthropometric measurements due to limited survey time or lack of measurement technology in face-to-face general-purpose surveys or in mailed, online, or mobile device-based surveys. METHODS: A cross-sectional study was conducted in the Republic of Seychelles with a sample of 1240 adults. We compared self-reported body sizes measured by Pulvers' silhouette showcards to four measurements of body size and adiposity: body mass index (BMI), body fat percent measured, waist circumference, and waist to height ratio. The accuracy of silhouettes as an obesity indicator was examined using sex-specific receiver operator curve (ROC) analysis and the reliability of this tool to detect socioeconomic gradients in obesity was compared to BMI-based measurements. RESULTS: Our study supports silhouette body size showcards as a valid and reliable survey tool to measure self-reported body size and adiposity in an African population. The mean correlation coefficients of self-reported silhouettes with measured BMI were 0.80 in men and 0.81 in women (P < 0.001). The silhouette showcards also showed high accuracy for detecting obesity as per a BMI ≥ 30 (Area under curve, AUC: 0.91/0.89, SE: 0.01), which was comparable to other measured adiposity indicators: fat percent (AUC: 0.94/0.94, SE: 0.01), waist circumference (AUC: 0.95/0.94, SE: 0.01), and waist to height ratio (AUC: 0.95/0.94, SE: 0.01) amongst men and women, respectively. The use of silhouettes in detecting obesity differences among different socioeconomic groups resulted in similar magnitude, direction, and significance of association between obesity and socioeconomic status as when using measured BMI. CONCLUSIONS: This study highlights the validity and reliability of silhouettes as a survey tool for measuring obesity in a population in the African region. The ease of use and cost-effectiveness of this tool makes it an attractive alternative to measured BMI in the design of non-face-to-face online- or mobile device-based surveys as well as in-person general-purpose surveys of obesity in social sciences, where limited resources do not allow for direct anthropometric measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Un certain nombre de patients palliatifs en fin de vie présentent des symptômes qui ne peuvent pas être soulagés malgré la mise en oeuvre de tous les moyens traditionnels à disposition. Pour ces patients, lorsque des symptômes réfractaires induisent une souffrance intolérable, la sédation palliative est un moyen de dernier recours qui peut leur offrir un soulagement transitoire ou même définitif. Tout en présentant les enjeux éthiques, cet article explore les dimensions cliniques d'ordre pratique qui peuvent se présenter lors d'une sédation palliative chez un patient en fin de vie. Patients at the end-of-life may present with refractory symptoms which cannot be adequately relieved despite the use of all traditional means. When refractory symptoms lead to intolerable suffering, palliative sedation is a last recourse temporary or definitive treatment. While discussing ethical issues, clinical practice dimensions of palliative sedation are explored in this article

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interpretation of complex DNA profiles is facilitated by a Bayesian approach. This approach requires the development of a pair of propositions: one aligned to the prosecution case and one to the defense case. This note explores the issue of proposition setting in an adversarial environment by a series of examples. A set of guidelines generalize how to formulate propositions when there is a single person of interest and when there are multiple individuals of interest. Additional explanations cover how to handle multiple defense propositions, relatives, and the transition from subsource level to activity level propositions. The propositions depend on case information and the allegations of each of the parties. The prosecution proposition is usually known. The authors suggest that a sensible proposition is selected for the defense that is consistent with their stance, if available, and consistent with a realistic defense if their position is not known.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The question of the age of fingermarks is often raised in investigations and trials when suspects admit that they have left their fingermarks at a crime scene but allege that the contact occurred at a different time than the crime and for legal reasons. In the first part of this review article, examples from American appellate court cases will be used to demonstrate that there is a lack of consensus among American courts regarding the admissibility and weight of testimony from expert witnesses who provide opinions about the age of fingermarks. Of course, these issues are not only encountered in America but have also been reported elsewhere, for example in Europe. The disparity in the way fingermark dating cases were managed in these examples is probably due to the fact that no methodology has been validated and accepted by the forensic science community so far. The second part of this review article summarizes the studies reported on fingermark dating in the literature and highlights the fact that most proposed methodologies still suffer from limitations preventing their use in practice. Nevertheless, several approaches based on the evolution of aging parameters detected in fingermark residue over time appear to show promise for the fingermark dating field. Based on these approaches, the definition of a formal methodological framework for fingermark dating cases is proposed in order to produce relevant temporal information. This framework identifies which type of information could and should be obtained about fingermark aging and what developments are still required to scientifically address dating issues.