199 resultados para nose prosthesis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The objective of the present study was to compare current results of prosthetic valve replacement following acute infective native valve endocarditis (NVE) with that of prosthetic valve endocarditis (PVE). Prosthetic valve replacement is often necessary for acute infective endocarditis. Although valve repair and homografts have been associated with excellent outcome, homograft availability and the importance of valvular destruction often dictate prosthetic valve replacement in patients with acute bacterial endocarditis. METHODS: A retrospective analysis of the experience with prosthetic valve replacement following acute NVE and PVE between 1988 and 1998 was performed at the Montreal Heart Institute. RESULTS: Seventy-seven patients (57 men and 20 women, mean age 48 +/- 16 years) with acute infective endocarditis underwent valve replacement. Fifty patients had NVE and 27 had PVE. Four patients (8%) with NVE died within 30 days of operation and there were no hospital deaths in patients with PVE. Survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 70% +/- 9%, 59% +/- 10%, and 55% +/- 10% for PVE, respectively (p = 0.15). Reoperation-free survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 45% +/- 10%, 40% +/- 10%, and 36% +/- 9% for PVE (p = 0.003). Five-year survival for NVE averaged 75% +/- 9% following aortic valve replacement and 79% +/- 9% following mitral valve replacement. Five-year survival for PVE averaged 66% +/- 12% following aortic valve replacement and 43% +/- 19% following mitral valve replacement (p = 0.75). Nine patients underwent reoperation during follow-up: indications were prosthesis infection in 4 patients (3 mitral, 1 aortic), dehiscence of mitral prosthesis in 3, and dehiscence of aortic prosthesis in 2. CONCLUSIONS: Prosthetic valve replacement for NVE resulted in good long-term patient survival with a minimal risk of reoperation compared with patients who underwent valve replacement for PVE. In patients with PVE, those who needed reoperation had recurrent endocarditis or noninfectious periprosthetic dehiscence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Off-pump trans left ventricular approach provides more precise deployment of stented aortic valve of any size with respect to the endovascular replacement. One of the key steps of this procedure is the ventricle repair after catheter withdrawing. We designed an animal study to compare the consistency of a sutureless repair of the left ventricle access using nitinol occluder with and without pericardial cuff on the ventricular side. METHODS: Material description: The Amplatz-nitinol occluder consists of two square heads squeezing ventricle wall in between them, sealing the defect. To improve its sealing property, a pericardial patch was sutured to the ventricular head of the occluder. Animal study setup: In adult pigs, a 30F sheath was inserted into the epigastric area through the cardiac apex, up to the left ventricle, simulating the approach for off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with standard occluder in half of the animals, and cuffed occluder in the other half. Animals were followed-up for 3h, collecting haemodynamics data and pericardial bleeding. RESULTS: Device was successfully deployed in 12 animals in less than 1min. In the group where the standard occluder was used, bleeding during the deployment was 80+/-20ml and after the deployment was 800+/-20ml over 3h. In the group where the cuffed occluder was used, bleeding during the deployment was 85+/-20ml and after the deployment was 100+/-5ml over 3h. In the cuffed group, bleeding was significantly lower than the standard group, p-value being <0.001. CONCLUSIONS: The occluder is easy to use and the pericardial cuff dramatically increases its efficacy as demonstrated by a significant reduction of blood loss. The cuffed occluder opens the way for endoscopic, off-pump, transventricular aortic valve replacement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transapical aortic valve replacement through an apical aneurysm is traditionally contraindicated because of the risk of severe systemic embolization when thrombi are present. However, a chronic fibrotic aneurysm without apical thrombi carries a low risk of distal embolization and can be safely employed for a transapical transcatheter aortic valve replacement in case of absence of an alternative access site (severe vascular disease, small vascular sizes and diseased calcified aorta). We illustrate our experience with a 73-year-old patient suffering from symptomatic aortic valve stenosis, coronary artery disease with occluded left anterior descending artery, left ventricular apical aneurysm and severe peripheral vascular disease, who successfully underwent a transapical 26 mm Sapien? XT stent-valve implantation through the fibrotic thin akinetic apical wall.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active abduction was simulated from 0 degrees to 150 degrees of elevation. With the anatomical prosthesis, the joint force almost reached the equivalence of body weight. The joint force was half this for the reversed prosthesis. The direction of force was much more vertically aligned for the reverse prosthesis, in the first 90 degrees of abduction. With the reversed prosthesis, abduction was possible without rotator cuff muscles and required 20% less deltoid force to achieve it. This force analysis confirms the potential mechanical advantage of reversed prostheses when rotator cuff muscles are deficient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Ankle arthropathy is associated with a decreased motion of the ankle-hindfoot during ambulation. Ankle arthrodesis was shown to result in degeneration of the neighbour joints of the foot. Inversely, total ankle arthroplasty conceptually preserves the adjacent joints because of the residual mobility of the ankle but this has not been demonstrated yet in vivo. It has also been reported that degenerative ankle diseases, and even arthrodesis, do not result in alteration of the knee and hip joints. We present the preliminary results of a new approach of this problem based on ambulatory gait analysis. Patients and Methods: Motion analysis of the lower limbs was performed using a Physilog® (BioAGM, CH) system consisting of three-dimensional (3D) accelerometer and gyroscope, coupled to a magnetic system (Liberty©, Polhemus, USA). Both systems have been validated. Three groups of two patients were included into this pilot study and compared to healthy subjects (controls) during level walking: patients with ankle osteoarthritis (group 1), patients treated by ankle arthrodesis (group 2), patients treated by total ankle prosthesis (group 3). Results: Motion patterns of all analyzed joints over more than 20 gait cycles in each subject were highly repeatable. Motion amplitude of the ankle-hindfoot in control patients was similar to recently reported results. Ankle arthrodesis limited the motion of the ankle-hindfoot in the sagittal and horizontal planes. The prosthetic ankle allowed a more physiologic movement in the sagittal plane only. Ankle arthritis and its treatments did not influence the range of motion of the knee and hip joint during stance phase, excepted for a slight decrease of the hip flexion in groups 1 and 2. Conclusion: The reliability of the system was shown by the repeatability of the consecutive measurements. The results of this preliminary study were similar to those obtained through laboratory gait analysis. However, our system has the advantage to allow ambulatory analysis of 3D kinematics of the lower limbs outside of a gait laboratory and in real life conditions. To our knowledge this is a new concept in the analysis of ankle arthropathy and its treatments. Therefore, there is a potential to address specific questions like the difficult comparison of the benefits of ankle arthroplasty versus arthrodesis. The encouraging results of this pilot study offer the perspective to analyze the consequences of ankle arthropathy and its treatments on the biomechanics of the lower limbs ambulatory, in vivo and in daily life conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trans-apical aortic valve replacement (AVR) is a new and rapidly growing therapy. However, there are only few training opportunities. The objective of our work is to build an appropriate artificial model of the heart that can replace the use of animals for surgical training in trans-apical AVR procedures. To reduce the necessity for fluoroscopy, we pursued the goal of building a translucent model of the heart that has nature-like dimensions. A simplified 3D model of a human heart with its aortic root was created in silico using the SolidWorks Computer-Aided Design (CAD) program. This heart model was printed using a rapid prototyping system developed by the Fab@Home project and dip-coated two times with dispersion silicone. The translucency of the heart model allows the perception of the deployment area of the valved-stent without using heavy imaging support. The final model was then placed in a human manikin for surgical training on trans-apical AVR procedure. Trans-apical AVR with all the necessary steps (puncture, wiring, catheterization, ballooning etc.) can be realized repeatedly in this setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To compare the results of rapid PCR screening for MRSA using the GeneXpert system with those of cultures in an outbreak setting. Methods: GeneXpert was used for screening MRSA in nose, throat, groin, and other clinical samples during a 6-month period. Samples were performed using a double-swab transystem. When >1 sample was found positive in a screening set, all second swabs of the set were analysed by culture. Results: From June to October 2009, 7568 rapid tests were performed, among which 432 (5.7%) were positive (nose: 149/2090, 7.1%; throat: 98/2078, 4.7%; groin: 152/2080, 7.3%; urine: 14/1090, 1.3%; wounds: 18/150, 12%; and others:1/27, 3.7%), and 84 (1.1%) were invalid. A total of 1517 samples were analyzed by both rapid PCR and culture. Rapid tests had a sensitivity of 0.896 compared to cultures, a specificity of 0.769, a PPV of 0.763, and a NPV of 0.899. The rapid test was found to be less sensitive in throat samples (0.81) than in nose or inguinal samples (0.93 for both). In 32/192 (16%) patients a positive rapid PCR result was not confirmed by culture, despite several subsequent screening samples in some patients. Cycle threshold (Ct) for SCCmec of these PCR positive reactions were all >30. Conclusions: GeneXpert MRSA was found to be suitable for the rapid detection in nose, inguinal, and throat samples, however with a lower sensitivity in the later. Negative cultures in 16% of our PCR-positive patients raised the question of false positivity or higher sensitivity of GeneXpert. Further work is needed to investigate these cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Discrimination of species-specific vocalizations is fundamental for survival and social interactions. Its unique behavioral relevance has encouraged the identification of circumscribed brain regions exhibiting selective responses (Belin et al., 2004), while the role of network dynamics has received less attention. Those studies that have examined the brain dynamics of vocalization discrimination leave unresolved the timing and the inter-relationship between general categorization, attention, and speech-related processes (Levy et al., 2001, 2003; Charest et al., 2009). Given these discrepancies and the presence of several confounding factors, electrical neuroimaging analyses were applied to auditory evoked-potential (AEPs) to acoustically and psychophysically controlled non-verbal human and animal vocalizations. This revealed which region(s) exhibit voice-sensitive responses and in which sequence. Methods: Subjects (N=10) performed a living vs. man-made 'oddball' auditory discrimination task, such that on a given block of trials 'target' stimuli occurred 10% of the time. Stimuli were complex, meaningful sounds of 500ms duration. There were 120 different sound files in total, 60 of which represented sounds of living objects and 60 man-made objects. The stimuli that were the focus of the present investigation were restricted to those of living objects within blocks where no response was required. These stimuli were further sorted between human non-verbal vocalizations and animal vocalizations. They were also controlled in terms of their spectrograms and formant distributions. Continuous 64-channel EEG was acquired through Neuroscan Synamps referenced to the nose, band-pass filtered 0.05-200Hz, and digitized at 1000Hz. Peri-stimulus epochs of continuous EEG (-100ms to 900ms) were visually inspected for artifacts, 40Hz low-passed filtered and baseline corrected using the pre-stimulus period . Averages were computed from each subject separately. AEPs in response to animal and human vocalizations were analyzed with respect to differences of Global Field Power (GFP) and with respect to changes of the voltage configurations at the scalp (reviewed in Murray et al., 2008). The former provides a measure of the strength of the electric field irrespective of topographic differences; the latter identifies changes in spatial configurations of the underlying sources independently of the response strength. In addition, we utilized the local auto-regressive average distributed linear inverse solution (LAURA; Grave de Peralta Menendez et al., 2001) to visualize and statistically contrast the likely underlying sources of effects identified in the preceding analysis steps. Results: We found differential activity in response to human vocalizations over three periods in the post-stimulus interval, and this response was always stronger than that to animal vocalizations. The first differential response (169-219ms) was a consequence of a modulation in strength of a common brain network localized into the right superior temporal sulcus (STS; Brodmann's Area (BA) 22) and extending into the superior temporal gyrus (STG; BA 41). A second difference (291-357ms) also followed from strength modulations of a common network with statistical differences localized to the left inferior precentral and prefrontal gyrus (BA 6/45). These two first strength modulations correlated (Spearman's rho(8)=0.770; p=0.009) indicative of functional coupling between temporally segregated stages of vocalization discrimination. A third difference (389-667ms) followed from strength and topographic modulations and was localized to the left superior frontal gyrus (BA10) although this third difference did not reach our spatial criterion of 12 continuous voxels. Conclusions: We show that voice discrimination unfolds over multiple temporal stages, involving a wide network of brain regions. The initial stages of vocalization discrimination are based on modulations in response strength within a common brain network with no evidence for a voice-selective module. The latency of this effect parallels that of face discrimination (Bentin et al., 2007), supporting the possibility that voice and face processes can mutually inform one another. Putative underlying sources (localized in the right STS; BA 22) are consistent with prior hemodynamic imaging evidence in humans (Belin et al., 2004). Our effect over the 291-357ms post-stimulus period overlaps the 'voice-specific-response' reported by Levy et al. (Levy et al., 2001) and the estimated underlying sources (left BA6/45) were in agreement with previous findings in humans (Fecteau et al., 2005). These results challenge the idea that circumscribed and selective areas subserve con-specific vocalization processing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PATIENTS: All neonates admitted between January 2002 and December 2007 treated by nCPAP were eligible. METHODS: Patients' noses were monitored during nCPAP. Nasal trauma was reported into three stages: (I) persistent erythema; (II) superficial ulceration; and (III) necrosis. RESULTS: 989 neonates were enrolled. Mean gestational age was 34 weeks (SD 4), mean birth weight 2142 g (SD 840). Nasal trauma was reported in 420 (42.5%) patients and it was of stage I, II and III in 371 (88.3%), 46 (11%) and 3 (0.7%) patients, respectively. Incidence and severity of trauma were inversely correlated with gestational age and birth weight. The risk of nasal trauma was greater in neonates <32 weeks of gestational age (OR 2.48, 95% CI 1.59 to 3.86), weighing <1500 g at birth (OR 2.28, 95% CI 1.43 to 3.64), treated >5 days by nCPAP (OR 5.36, 95% CI 3.82 to 7.52), or staying >14 days in the NICU (OR 1.67, 95% CI 1.22 to 2.28). Most cases of nasal trauma (90%) appeared during the first 6 days of nCPAP. Persistent visible scars were present in two cases. CONCLUSIONS: Nasal trauma is a frequent complication of nCPAP, especially in preterm neonates, but long-term cosmetic sequelae are very rare. This study provides a description of nasal trauma and proposes a simple staging system. This could serve as a basis to develop strategies of prevention and treatment of this iatrogenic event.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: In forensic toxicology, cocaine is better known for its powerful stimulating effects of nervous system and its high potential for recreational abuse, than for his therapeutic use. However, cocaine is still use as a topical anesthetic and peripheral vasoconstrictor in surgeries of eye, ear, nose and throat. Last decade, an increase of the presence of cocaine and metabolites in blood samples of drivers suspected to drive under the influence of drugs (DUID) was observed in Switzerland (Augsburger et al., Forensic Sci Int 153 (2005) 11-15; Senna et al., Forensic Sci Int 198 (2010) 11-16). Observed blood concentration ranges of cocaine and benzoylecgonine were 10-925 μg/L and 20-5200 μg/L, respectively. Since 2005, zero-tolerance approach was introduced in the Swiss legislation for different substances, especially cocaine (analytical cutoff: 15 μg/L). Thus, the interpretation often amounts to determine if the concentration is situated above or under the limit. However, it is important for the interpretation to take into account the context and to be critical with the obtained results, at the risk of ending in erroneous conclusions. Methods: Systematical toxicological analyses were performed on blood and urine, if available, for 5 DUID cases, as already published (Augsburger et al., Forensic Sci Int 153 (2005)). Positive results were confirmed and drugs were quantified in biological samples by GCMS, GC-MS/MS or LC-MS/MS. Results: Administration of cocaine after traffic accident was identified in five cases. All people were admitted to the emergency room because of severe trauma. Maxillofacial surgery was done shortly after admission to the emergency room, involving use of nasal application of cocaine (swab). For all cases, use of cocaine swab was not mentioned in the document filled by the police and by medical staff requested for blood and urine sampling. The information was obtained retrospectively after consultation of the medical records, without precise indication of the application time or dose. Case 1. A 83-year old man (pedestrian) was hit by a car. Blood (+11h after the accident): cocaine (16 μg/L), benzoylecgonine (370 μg/L). Urine: cocaine (1700 μg/L), benzoylecgonine (560 μg/L). Case 2. A 84-year old woman (pedestrian) was hit by a car. Blood (+1.5h after the accident): cocaine (230 μg/L), benzoylecgonine (370 μg/L). Urine was not available. Hair (+4 months after the accident): segment 1 (0-2 cm), cocaine not detected; segment 2 (2-4 cm), cocaine: <0.5 ng/mg. Case 3. A 66-year old man was involved in a car/car accident. He died 2 hours and 5 minutes after the crash. Blood (+1.5h after the accident): cocaine and metabolites not detected. Blood (+2h after the accident): cocaine (1750 μg/L), benzoylecgonine (460 μg/L). Blood (post-mortem): cocaine (370 μg/L), benzoylecgonine (200 μg/L). Urine (+1.5h after the accident): cocaine not detected. Case 4. A 57-year old woman on a motor scooter was hit by a car. She died 2 hours and 10 minutes after the crash. Blood (+0.5h after the accident): cocaine and metabolites not detected. Urine (post-mortem): cocaine (<20 μg/L), benzoylecgonine (120 μg/L). Case 5. A 30-year old man was involved in a car accident. Blood (+4h after the accident): cocaine (29 μg/L), benzoylecgonine (< 20 μg/L). Urine (+4h after the accident): cocaine and metabolites not detected. Ethanol (1,32 g/kg) and cannabinoids (THC (2,0 μg/L), THCCOOH (38 μg/L)) were also detected in blood. Conclusion: To our knowledge, this is the first description of DUID cases involving therapeutic use of cocaine after an accident. These results indicate that even if a per se law is effective for prosecution case of DUID, a critical interpretation of the results is always needed, especially if a medical intervention occurs after an accident.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Perioperative visual loss (PVL) is a very rare and unpredictable complication of surgery performed at distance from the visual pathways, mostly after spine or cardiac procedures. We report 6 consecutive patients with PVL after routine orthopedic procedures (osteosynthesis for complex fracture of the femur [2], total hip arthroplasty [2], hip prosthesis arthroplasty [1], bilateral simultaneous total knee arthroplasty [1]) and reviewed the literature on the subject. An ischemic optic neuropathy was diagnosed in all cases, and visual loss was bilateral in 5 of 6 patients. Partial visual improvement occurred in only 3 of 11 eyes. No specific therapy is available for PVL. Postoperative visual disturbances should prompt without delay an ophthalmic evaluation because emergent correction of anemia, systemic hypotension, or hypovolemia might improve visual prognosis of PVL.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The Contegra bioprosthesis (valved heterologous bovine jugular vein) is used for reconstruction of the right ventricular outflow tract (RVOT) in congenital heart malformations and pulmonary valve replacement in different settings. Compared to pulmonary homografts, the Contegra conduit is readily available 'on the shelf'. So far, its use was mainly described in children. The aim of this study is to evaluate the feasibility and the outcome of Contegra graft implantation in the adult. METHODS: Between November 1999 and December 2007, a total of 32 Contegra grafts were implanted in 31 patients (24 men and 7 women), with a mean age of 35.7+/-10.5 years (range 18-54 years). All operations have been completed through median sternotomy with cardiopulmonary bypass. Indications included: Ross procedure for aortic valve disease (n=22); re-operation of corrected Fallot-tetralogy (n=5); isolated pulmonary valve disease (n=2); re-operation of double outlet right ventricle (DORV) (n=1); pulmonary stenosis in congenital dilated cardiomyopathy (DCM) (n=1). Conduit sizes included 22 mm (n=31), 20 mm (n=1). RESULTS: There was no hospital mortality and no valved conduit related early morbidity. In the median follow-up of 38 months (range 1-99 months) of 28 patients there was one late death, not conduit related (total mortality 3.6%). Re-operation for symptomatic graft stenosis was realised in two patients, 7 and 16 months after primo-implantation, corresponding to graft related late morbidity of 7.1%. CONCLUSIONS: In this small review of 32 operations using the Contegra graft for RVOT reconstruction in adult cardiac surgery for different indications, we observed good postoperative mid-term results concerning conduit function. Mean transpulmonary pressure gradients remain low (13.3+/-6.6 mmHg postoperative, 14.5+/-7.9 mmHg at follow-up). The use of the Contegra graft seems to be a good alternative to the homograft with low operative mortality and morbidity. Long-term outcome data are not available and further investigations must be performed to evaluate results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Correct positioning of the tibial component in total knee arthroplasty (TKA) must take into account both an optimal bone coverage (defined by a maximal cortical bearing with posteromedial and anterolateral support) and satisfactory patellofemoral tracking. Consequently, a compromise position must be found by the surgeon during the operation to simultaneously meet these two requirements. Moreover, tibial tray positioning depends upon the tibial torsion, which has been shown to act mainly in the proximal quarter of the tibia. Therefore, the correct application of the tibial tray is also theoretically related to the level of bone resection. In this study, we first quantified the torsional profile given by an optimal bone coverage for a symmetrical tibial tray design and for an asymmetrical one. Then, for the two types of tibial trays, we measured the angle difference between optimal bone coverage and an alignment on the middle of the tibial tubercule. Results showed that the values of the torsional profile given by the symmetrical tray were more scattered than those from the asymmetrical one. However, determination of the mean differential angle between the position providing optimal bone coverage and the one providing the best patellofemoral tracking indicated that the symmetrical prosthetic tray offered the best compromise between these two requirements. Although the tibiofemoral joint is known to be asymmetric in both shape and dimension, the asymmetrical tray chosen in this study was found to fulfill this compromise with more difficulty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Painful total hip replacement remains a challenging problem because of the large amount of possible diagnoses. We report about a 64-year-old female patient who was misdiagnosed during 4 years as psychiatric. She suffered of excruciating left retrotrochanteric pain after the implantation of a cementless total hip replacement and revision because of recurrent hip dislocations. Walking was limited to short distances using two crutches. The work-up at this time included the usual diagnoses and remained unsuccessful. No loosening, infection or malposition of the prosthesis could be found, and she had no neurologic deficits in her operated leg. An MRI was obtained to visualize the retrotrochanteric soft tissues and showed a tight scar surrounding the sciatic nerve, which was also compressed by an adjacent lipoma. Therefore, she was reoperated on to remove the lipoma and the scar tissue around the sciatic nerve. To decrease the risk of recurrent scarring around the sciatic nerve, an adhesion barrier was applied before closure. One year after the operation, the patient has no neurologic deficit, no more pain and is able to walk unlimited distances without crutches. Scar tissue around the sciatic nerve is frequently observed during revision surgery. However, we feel that sciatic nerve entrapment by scar tissue should be a part of the differential diagnosis of painful THR. MRI may be a useful tool to achieve this diagnosis.