194 resultados para nonporous metal support
Resumo:
Undernutrition is an independent factor of postoperative morbidity and mortality The aim of a preoperative nutritional support is to enhance immune muscular and cognitive functions, and to support wound healing This nutritional support (e g dietary management enteral or parenteral nutrition) should be limited to high risk situations with a beneficial effect of nutrition for the patient undernutrition major surgery and elderly Preoperative nutritional support should be scheduled for atleast 7 to 10 days before the surgery During the preoperative period the type and route of an eventual postoperative nutritional assistance should be anticipated In the case of emergency surgery nutritional assessment of the patient should be done as soon as possible before surgery or in the 48 h postoperative period Finally, in elective surgery, preoperative fasting should be limited to 2-3 hours for clear liquids and 6 hours for solids (C) 2010 Published by Elsevier Masson SAS
Resumo:
Objective. To measure support for seasonal influenza vaccination requirements among US healthcare personnel (HCP) and its associations with attitudes regarding influenza and influenza vaccination and self-reported coverage by existing vaccination requirements. Design. Between June 1 and June 30, 2010, we surveyed a sample of US HCP ([Formula: see text]) recruited using an existing probability-based online research panel of participants representing the US general population as a sampling frame. Setting. General community. Participants. Eligible HCP who (1) reported having worked as medical doctors, health technologists, healthcare support staff, or other health practitioners or who (2) reported having worked in hospitals, ambulatory care facilities, long-term care facilities, or other health-related settings. Methods. We analyzed support for seasonal influenza vaccination requirements for HCP using proportion estimation and multivariable probit models. Results. A total of 57.4% (95% confidence interval, 53.3%-61.5%) of US HCP agreed that HCP should be required to be vaccinated for seasonal influenza. Support for mandatory vaccination was statistically significantly higher among HCP who were subject to employer-based influenza vaccination requirements, who considered influenza to be a serious disease, and who agreed that influenza vaccine was safe and effective. Conclusions. A majority of HCP support influenza vaccination requirements. Moreover, providing HCP with information about the safety of influenza vaccination and communicating that immunization of HCP is a patient safety issue may be important for generating staff support for influenza vaccination requirements.
Resumo:
INTRODUCTION. Patient-ventilator asynchrony is a frequent issue in non invasivemechanical ventilation (NIV) and leaks at the patient-mask interface play a major role in itspathogenesis. NIV algorithms alleviate the deleterious impact of leaks and improve patient-ventilator interaction. Neurally adusted ventilatory assist (NAVA), a neurally triggered modethat avoids interferences between leaks and the usual pneumatic trigger, could further improvepatient-ventilator interaction in NIV patients.OBJECTIVES. To evaluate the feasibility ofNAVAin patients receiving a prophylactic postextubationNIV and to compare the respective impact ofPSVandNAVAwith and withoutNIValgorithm on patient-ventilator interaction.METHODS. Prospective study conducted in 16 beds adult critical care unit (ICU) in a tertiaryuniversity hospital. Over a 2 months period, were included 17 adult medical ICU patientsextubated for less than 2 h and in whom a prophylactic post-extubation NIV was indicated.Patients were randomly mechanically ventilated for 10 min with: PSV without NIV algorithm(PSV-NIV-), PSV with NIV algorithm (PSV-NIV+),NAVAwithout NIV algorithm (NAVANIV-)and NAVA with NIV algorithm (NAVA-NIV+). Breathing pattern descriptors, diaphragmelectrical activity, leaks volume, inspiratory trigger delay (Tdinsp), inspiratory time inexcess (Tiexcess) and the five main asynchronies were quantified. Asynchrony index (AI) andasynchrony index influenced by leaks (AIleaks) were computed.RESULTS. Peak inspiratory pressure and diaphragm electrical activity were similar in thefour conditions. With both PSV and NAVA, NIV algorithm significantly reduced the level ofleak (p\0.01). Tdinsp was not affected by NIV algorithm but was shorter in NAVA than inPSV (p\0.01). Tiexcess was shorter in NAVA and PSV-NIV+ than in PSV-NIV- (p\0.05).The prevalence of double triggering was significantly lower in PSV-NIV+ than in NAVANIV+.As compared to PSV,NAVAsignificantly reduced the prevalence of premature cyclingand late cycling while NIV algorithm did not influenced premature cycling. AI was not affectedby NIV algorithm but was significantly lower in NAVA than in PSV (p\0.05). AIleaks wasquasi null with NAVA and significantly lower than in PSV (p\0.05).CONCLUSIONS. NAVA is feasible in patients receiving a post-extubation prophylacticNIV. NAVA and NIV improve patient-ventilator synchrony in different manners. NAVANIV+offers the best patient-ventilator interaction. Clinical studies are required to assess thepotential clinical benefit of NAVA in patients receiving NIV.
Resumo:
Introduction Preventing drug incompatibilities has a high impact onthe safety of drug therapy. Although there are no internationalguidelines to manage drug incompatibilities, different decision-supporttools such as handbooks, cross-tables and databases are available.In a previous study, two decision-support tools have been pre-selectedby pharmacists as fitting nurses' needs on the wards1. The objective ofthis study was to have these both tools evaluated by nurses todetermine which would be the most suitable for their daily practice.Materials & Methods Evaluated tools were:1. Cross-table of drug pairs (http://files.chuv.ch/internet-docs/pha/medicaments/pha_phatab_compatibilitessip.pdf)2. Colour-table (a colour for each drug according to the pH: red =acid; blue = basic; yellow = neutral; black = to be infused alone)2Tools were assessed by 48 nurses in 5 units (PICU, adult andgeriatric intensive care, surgery, onco-hematology) using a standardizedform1. The scientific accuracy of the tools was evaluated bydetermining the compatibility of five drugs pairs (rate of correctanswers according to the Trissel's Handbook on Injectable Drugs,chi-square test). Their ergonomics, design, reliability and applicabilitywere estimated using visual analogue scales (VAS 0-10; 0 =null, 10 = excellent). Results are expressed as the median and interquartilerange (IQR) for 25% and 75% (Wilcoxon rank sum test).Results The rate of correct answers was above 90% for both tools(cross-table 96.2% vs colour-table 92.5%, p[0.05).The ergonomics and the applicability were higher for the crosstable[7.1 (IQR25 4.0, IQR75 8.0) vs 5.0 (IQR25 2.7, IQR75 7.0), p =0.025 resp. 8.3 (IQR25 7.4, IQR75 9.2) vs 7.6 (IQR25 5.9, IQR75 8.8)p = 0.047].The design of the colour-table was judged better [4.6 (IQR25 2.9,IQR75 7.1) vs 7.1 (IQR25 5.4, IQR75 8.4) p = 0.002].No difference was observed in terms of reliability [7.3 (IQR25 6.5,IQR75 8.4) vs 6.7 (IQR25 5.0, IQR758.6) p[0.05].The cross-table was globally preferred by 65% of the nurses (27%colour-table, 8% undetermined) and 68% would like to have thisdecision-support tool available for their daily practice.Discussion & Conclusion Both tools showed the same accuracy toassess drug compatibility. In terms of ergonomics and applicabilitythe cross-table was better than the colour-table, and was preferred bythe nurses for their daily practice. The cross-table will be implementedin our hospital as decision-support tool to help nurses tomanage drug incompatibilities.
Resumo:
Because of the various matrices available for forensic investigations, the development of versatile analytical approaches allowing the simultaneous determination of drugs is challenging. The aim of this work was to assess a liquid chromatography-tandem mass spectrometry (LC-MS/MS) platform allowing the rapid quantification of colchicine in body fluids and tissues collected in the context of a fatal overdose. For this purpose, filter paper was used as a sampling support and was associated with an automated 96-well plate extraction performed by the LC autosampler itself. The developed method features a 7-min total run time including automated filter paper extraction (2 min) and chromatographic separation (5 min). The sample preparation was reduced to a minimum regardless of the matrix analyzed. This platform was fully validated for dried blood spots (DBS) in the toxic concentration range of colchicine. The DBS calibration curve was applied successfully to quantification in all other matrices (body fluids and tissues) except for bile, where an excessive matrix effect was found. The distribution of colchicine for a fatal overdose case was reported as follows: peripheral blood, 29 ng/ml; urine, 94 ng/ml; vitreous humour and cerebrospinal fluid, < 5 ng/ml; pericardial fluid, 14 ng/ml; brain, < 5 pg/mg; heart, 121 pg/mg; kidney, 245 pg/mg; and liver, 143 pg/mg. Although filter paper is usually employed for DBS, we report here the extension of this alternative sampling support to the analysis of other body fluids and tissues. The developed platform represents a rapid and versatile approach for drug determination in multiple forensic media.
Resumo:
The topic of conjugal quality provides an empirical illustration of the relevance of the configurational perspective on families. Based on a longitudinal sample of 1,534 couples living in Switzerland drawn from the study "Social Stratification, Cohesion and Conflict in Contemporary Families", we show that various types of interdependencies with relatives and friends promote distinct conflict management strategies for couples as well as unequal levels of conjugal quality. We find that configurations characterized by supportive and non-interfering relationships with relatives and friends for both partners are associated with higher conjugal quality, while configurations characterized by interference are associated with lower conjugal quality.
Resumo:
Building a personalized model to describe the drug concentration inside the human body for each patient is highly important to the clinical practice and demanding to the modeling tools. Instead of using traditional explicit methods, in this paper we propose a machine learning approach to describe the relation between the drug concentration and patients' features. Machine learning has been largely applied to analyze data in various domains, but it is still new to personalized medicine, especially dose individualization. We focus mainly on the prediction of the drug concentrations as well as the analysis of different features' influence. Models are built based on Support Vector Machine and the prediction results are compared with the traditional analytical models.
Resumo:
The paper proposes an approach aimed at detecting optimal model parameter combinations to achieve the most representative description of uncertainty in the model performance. A classification problem is posed to find the regions of good fitting models according to the values of a cost function. Support Vector Machine (SVM) classification in the parameter space is applied to decide if a forward model simulation is to be computed for a particular generated model. SVM is particularly designed to tackle classification problems in high-dimensional space in a non-parametric and non-linear way. SVM decision boundaries determine the regions that are subject to the largest uncertainty in the cost function classification, and, therefore, provide guidelines for further iterative exploration of the model space. The proposed approach is illustrated by a synthetic example of fluid flow through porous media, which features highly variable response due to the parameter values' combination.