132 resultados para lymph vessel
Resumo:
Due to their relatively small size and central location within the thorax, improvement in signal-to-noise (SNR) is of paramount importance for in vivo coronary vessel wall imaging. Thus, with higher field strengths, coronary vessel wall imaging is likely to benefit from the expected "near linear" proportional gain in SNR. In this study, we demonstrate the feasibility of in vivo human high field (3 T) coronary vessel wall imaging using a free-breathing black blood fast gradient echo technique with respiratory navigator gating and real-time motion correction. With the broader availability of more SNR efficient fast spin echo and spiral techniques, further improvements can be expected.
Resumo:
BACKGROUND: Conventional x-ray angiography frequently underestimates the true burden of atherosclerosis. Although intravascular ultrasound allows for imaging of coronary plaque, this invasive technique is inappropriate for screening or serial examinations. We therefore sought to develop a noninvasive free-breathing MR technique for coronary vessel wall imaging. We hypothesized that such an approach would allow for in vivo imaging of coronary atherosclerosis. METHODS AND RESULTS: Ten subjects, including 5 healthy adult volunteers (aged 35+/-17 years, range 19 to 56 years) and 5 patients (aged 60+/-4 years, range 56 to 66 years) with x-ray-confirmed coronary artery disease (CAD), were studied with a T2-weighted, dual-inversion, fast spin-echo MR sequence. Multiple adjacent 5-mm cross-sectional images of the proximal right coronary artery were obtained with an in-plane resolution of 0.5x1.0 mm. A right hemidiaphragmatic navigator was used to facilitate free-breathing MR acquisition. Coronary vessel wall images were readily acquired in all subjects. Both coronary vessel wall thickness (1.5+/-0.2 versus 1.0+/-0.2 mm) and wall area (21.2+/-3.1 versus 13.7+/-4.2 mm(2)) were greater in patients with CAD (both P:<0.02 versus healthy adults). CONCLUSIONS: In vivo free-breathing coronary vessel wall and plaque imaging with MR has been successfully implemented in humans. Coronary wall thickness and wall area were significantly greater in patients with angiographic CAD. The presented technique may have potential applications in patients with known or suspected atherosclerotic CAD or for serial evaluation after pharmacological intervention.
Resumo:
Le prélèvement des ganglions sentinelles apparaît comme une technique séduisante pour l'évaluation ganglionnaire des cancers du col utérin de faible stade. La sélection d'une population à bas risque de métastase ganglionnaire, un entraînement minimal et le respect de quelques règles simples permettent de limiter le risque de faux négatif au minimum. La technique apporte des informations supplémentaires sur le plan anatomique en identifiant des ganglions situés en dehors des zones habituelles de curage, et sur le plan histologique avec la mise en évidence de cellules tumorales isolées et surtout de micrométastases dont la valeur pronostique est suspectée Sentinel node biopsy appears as a promising technique for the assessment of nodal disease in early cervical cancers. Selection of a population with a low risk of nodal metastasis, a minimal training, and simple rules allow a low false negative rate. Sentinel node biopsy provides supplementary information, such as anatomical information (nodes outside of routine lymphadenectomy areas) and histological information (isolated tumors cells and micrometastases).
Resumo:
BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.
Resumo:
During T cell-dependent antibody responses lymph node B cells differentiate either to plasmablasts that grow in the medullary cords, or to blasts that proliferate in follicles forming germinal centers. Many plasmablasts differentiate to plasma cells locally, but some leave the medullary cords and migrate to downstream lymph nodes. To assess the basis for this migration, changes in the responsiveness of B cells to a range of chemokines have been studied as they differentiate. Naive B cells express high levels of CCR6, CCR7, CXCR4 and CXCR5. When activated B cells grow in follicles the expression of these chemokine receptors and the responsiveness to the respective chemokines is retained. During the extrafollicular response, plasmablast expression of CXCR5 and responsiveness to B-lymphocyte chemoattractant (CXCR5) as well as to secondary lymphoid tissue chemokine (CCR7) and stromal cell-derived factor (SDF)-1 (CXCR4) are lost while a weak response towards the CCR6 chemokine LARC is maintained. Despite losing responsiveness to SDF-1, extrafollicular plasmablasts still express high levels of CXCR4 on the cell surface. These results suggest that the combined loss of chemokine receptor expression and of chemokine responsiveness may be a necessary prerequisite for cells to migrate to the medullary cords and subsequently enter the efferent lymph.
Resumo:
Fibroblastic reticular cells (FRC) form the structural backbone of the T cell rich zones in secondary lymphoid organs (SLO), but also actively influence the adaptive immune response. They provide a guidance path for immigrating T lymphocytes and dendritic cells (DC) and are the main local source of the cytokines CCL19, CCL21, and IL-7, all of which are thought to positively regulate T cell homeostasis and T cell interactions with DC. Recently, FRC in lymph nodes (LN) were also described to negatively regulate T cell responses in two distinct ways. During homeostasis they express and present a range of peripheral tissue antigens, thereby participating in peripheral tolerance induction of self-reactive CD8(+) T cells. During acute inflammation T cells responding to foreign antigens presented on DC very quickly release pro-inflammatory cytokines such as interferon γ. These cytokines are sensed by FRC which transiently produce nitric oxide (NO) gas dampening the proliferation of neighboring T cells in a non-cognate fashion. In summary, we propose a model in which FRC engage in a bidirectional crosstalk with both DC and T cells to increase the efficiency of the T cell response. However, during an acute response, FRC limit excessive expansion and inflammatory activity of antigen-specific T cells. This negative feedback loop may help to maintain tissue integrity and function during rapid organ growth.
Resumo:
To assess the value of sampling lymph nodes located far sidelong colorectal cancer specimens, we analyzed retrospectively surgical specimens from 345 colorectal cancer patients. The mesocolic and perirectal fat was divided into 2 fractions: close to (<5 cm) and distant from (>5 cm) the tumor. Tumors were located in the cecum (n = 61), ascending colon (n = 29), transverse colon (n = 31), descending colon (n = 27), sigmoid colon (n = 108), and rectum (n = 89). The median number of lymph nodes sampled was 17 in both fractions (range, 4-66), 12 (range, 0-46) in the close fraction, and 3 (range, 0-33) in the distant fraction. There were 169 pN0, 104 pN1, and 72 pN2 cases. The pN staging was accurate in all cases except 10 based on the close fraction alone; of these, 6 were upstaged from pN0 to pN1 and 4 from pN1 to pN2 when the distant fraction was considered. Among pN1-upstaged cases, 5 were rectal (3/5 with neoadjuvant radiotherapy) and 1 colonic. In the colon, we found that lymph node location is more important than lymph node number because metastatic lymph nodes were present mostly in the peritumoral area. This suggests that lymph nodes should be initially recovered from the pericolic fat close to the tumor. If there are less than 4 positive lymph nodes and less than 12 lymph nodes examined in total, additional lymph nodes should be retrieved from the distal fraction for potential upstaging. In the rectum, systematic sampling of close and distant lymph nodes is mandatory because in rare cases, metastases are detected only in distant lymph nodes, particularly in patients who have undergone neoadjuvant radiotherapy.
Resumo:
AIMS: Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS: MRI vessel wall scans parallel to the right coronary artery (RCA) were obtained in 18 healthy individuals (age range 25-43, six women), with no known history of coronary artery disease, using a 3D dual-inversion navigator-gated black-blood spiral imaging sequence. Vessel wall scans were repeated 1 month later in eight subjects. The visible vessel wall segment and the wall thickness were quantitatively assessed using a semi-automatic tool and the intra-observer, inter-observer, and inter-scan reproducibilities were determined. The average imaged length of the RCA vessel wall was 44.5+/-7 mm. The average wall thickness was 1.6+/-0.2 mm. There was a highly significant intra-observer (r=0.97), inter-observer (r=0.94), and inter-scan (r=0.90) correlation for wall thickness (all P<0.001). There was also a significant agreement for intra-observer, inter-observer, and inter-scan measurements on Bland-Altman analysis. The intra-class correlation coefficients for intra-observer (r=0.97), inter-observer (r=0.92), and inter-scan (r=0.86) analyses were also excellent. CONCLUSION: The use of black-blood free-breathing 3D MRI in conjunction with semi-automated analysis software allows for reproducible measurements of right coronary arterial vessel-wall thickness. This technique may be well-suited for non-invasive longitudinal studies of coronary atherosclerosis.
Resumo:
The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.
Resumo:
Surgical tumor removal is often the treatment of choice in patients with head and neck squamous cell carcinoma. Depending on the extent of tumor resection, large defects are often produced in the individual head and neck regions, necessitating reconstructive surgery to avoid further functional impairment. In principle, this decision depends on the size and location of the defect, the aesthetic importance of the region and the functional significance of the area to be replaced. Reconstructive free flap procedures in patients who have undergone radiotherapy or exhibit vessel depletion in the neck due to multiple previous surgical interventions are particularly challenging. In order to ensure the best possible outcomes of surgical oncology therapies under difficult circumstances, this paper discusses the important factors and variables that can increase the success rate of microvascular grafts in irradiated or multiply resected patients.
Resumo:
Objective: Sentinel lymph node biopsy (SLNB) is a validated staging technique for breast carcinoma. Some women are exposed to have a second SLNB due to breast cancer recurrence or a second neoplasia (breast or other). Due to modi- fied anatomy, it has been claimed that previous axillary surgery represents a contra-indication to SLNB. Our objective was to analyse the literature to assess if a second SLNB is to be recommended or not. Methods: For the present study, we performed a review of all published data during the last 10 years on patients with previous axilla surgery and second SLNB. Results: Our analysis shows that second SLNB is feasible in 70%. Extra-axillary SNs rate (31%) was higher after radical lymph node dissection (ALND) (60% - 84%) than after SLNB alone (14% - 65%). Follow-up and com- plementary ALND following negative and positive second SLNB shows that it is a reliable procedure. Conclusion: The review of literature confirms that SLNB is feasible after previous axillary dissection. Triple technique for SN mapping is the best examination to highlight modified lymphatic anatomy and shows definitively where SLNB must be per- formed. Surgery may be more demanding as patients may have more frequently extra-axillary SN only, like internal mammary nodes. ALND can be avoided when second SLNB harvests negative SNs. These conclusions should however be taken with caution because of the heterogeneity of publications regarding SLNB and surgical technique.
Resumo:
The management of lymph nodes in nonmelanoma skin cancer patients is currently still debated. Merkel cell carcinoma (MCC), squamous cell carcinoma (SCC), pigmented epithelioid melanocytoma (PEM), and other rare skin neoplasms have a well-known risk to spread to regional lymph nodes. The use of sentinel lymph node biopsy (SLNB) could be a promising procedure to assess this risk in clinically N0 patients. Metastatic SNs have been observed in 4.5-28% SCC (according to risk factors), in 9-42% MCC, and in 14-57% PEM. We observed overall 30.8% positive SNs in 13 consecutive patients operated for high-risk nonmelanoma skin cancer between 2002 and 2011 in our institution. These high rates support recommendation to implement SLNB for nonmelanoma skin cancer especially for SCC patients. Completion lymph node dissection following positive SNs is also a matter of discussion especially in PEM. It must be remembered that a definitive survival benefit of SLNB in melanoma patients has not been proven yet. However, because of its low morbidity when compared to empiric elective lymph node dissection or radiation therapy of lymphatic basins, SLNB has allowed sparing a lot of morbidity and could therefore be used in nonmelanoma skin cancer patients, even though a significant impact on survival has not been demonstrated.
Resumo:
The stromal scaffold of the lymph node (LN) paracortex is built by fibroblastic reticular cells (FRCs). Conditional ablation of lymphotoxin-β receptor (LTβR) expression in LN FRCs and their mesenchymal progenitors in developing LNs revealed that LTβR-signaling in these cells was not essential for the formation of LNs. Although T cell zone reticular cells had lost podoplanin expression, they still formed a functional conduit system and showed enhanced expression of myofibroblastic markers. However, essential immune functions of FRCs, including homeostatic chemokine and interleukin-7 expression, were impaired. These changes in T cell zone reticular cell function were associated with increased susceptibility to viral infection. Thus, myofibroblasic FRC precursors are able to generate the basic T cell zone infrastructure, whereas LTβR-dependent maturation of FRCs guarantees full immunocompetence and hence optimal LN function during infection.