270 resultados para forensic sciences
Resumo:
The determination of dyes present in illicit pills is shown to be useful and easy-to-get information in strategic and tactical drug intelligence. An analytical strategy including solid-phase extraction (SPE) thin-layer chromatography (TLC) and capillary zone electrophoresis equipped with a diode array detector (CZE-DAD) was developed to identify and quantify 14 hydrosoluble, acidic, synthetic food dyes allowed in the European Community. Indeed, these may be the most susceptible dyes to be found in illicit pills through their availability and easiness of use. The results show (1) that this analytical method is well adapted to small samples such as illicit pills, (2) that most dyes actually found belong to hydrosoluble, acidic, synthetic food dyes allowed in the European Community, and (3) that this evidence turns out to be important in drug intelligence and may be assessed into a Bayesian framework.
Resumo:
The death of a person as a reaction to the death of another is known as Philemon and Baucis death and may represent a difficult challenge for pathologists, especially due to the decompositional changes that often characterized these situations. In this article, we describe two cases of Philemon and Baucis deaths, the first concerning a married couple and the second concerning a father and son. Postmortem investigations including radiology and biochemistry were performed. Based on the results of all investigations, deaths were attributed to natural causes. Third-party involvement could be excluded in both situations. In one case, biochemical analysis results revealed potentially contributing causes of death. The reported cases emphasize the importance of correlating findings from different postmortem investigations to identify causes of death, precipitating conditions and predisposing disorders, thus allowing the conclusion of natural death to be reached and third-party involvement to be excluded.
Resumo:
The determination of the age of a document is a very frequent query, however it is also one of the most challenging and controversial areas of questioned document examination. Several approaches were defined to address this problem. The first is based on the introduction date of raw constituents (like paper or ink) on the market. The second approach is based on the aging of documents, which is unfortunately not only influenced by passing time, but also by storage conditions and document composition. The third approach considers the relative age of documents and aims at reconstructing their chronology. The three approaches are equally complex to develop and encounter quantity of problems which are not negligible. This article aims to expose the potential applications and limitations of current ink dating methods. Method development and validation and the interpretation of evidence prove to be essential criteria for the dating of documents.
Resumo:
The determination of line crossing sequences between rollerball pens and laser printers presents difficulties that may not be overcome using traditional techniques. This research aimed to study the potential of digital microscopy and 3-D laser profilometry to determine line crossing sequences between a toner and an aqueous ink line. Different paper types, rollerball pens, and writing pressure were tested. Correct opinions of the sequence were given for all case scenarios, using both techniques. When the toner was printed before the ink, a light reflection was observed in all crossing specimens, while this was never observed in the other sequence types. The 3-D laser profilometry, more time-consuming, presented the main advantage of providing quantitative results. The findings confirm the potential of the 3-D laser profilometry and demonstrate the efficiency of digital microscopy as a new technique for determining the sequence of line crossings involving rollerball pen ink and toner. With the mass marketing of laser printers and the popularity of rollerball pens, the determination of line crossing sequences between such instruments is encountered by forensic document examiners. This type of crossing presents difficulties with optical microscopic line crossing techniques involving ballpoint pens or gel pens and toner (1-4). Indeed, the rollerball's aqueous ink penetrates through the toner and is absorbed by the fibers of the paper, leaving the examiner with the impression that the toner is above the ink even when it is not (5). Novotny and Westwood (3) investigated the possibility of determining aqueous ink and toner crossing sequences by microscopic observation of the intersection before and after toner removal. A major disadvantage of their study resides in destruction of the sample by scraping off the toner line to see what was underneath. The aim of this research was to investigate the ways to overcome these difficulties through digital microscopy and three-dimensional (3-D) laser profilometry. The former was used as a technique for the determination of sequences between gel pen and toner printing strokes, but provided less conclusive results than that of an optical stereomicroscope (4). 3-D laser profilometry, which allows one to observe and measure the topography of a surface, has been the subject of a number of recent studies in this area. Berx and De Kinder (6) and Schirripa Spagnolo (7,8) have tested the application of laser profilometry to determine the sequence of intersections of several lines. The results obtained in these studies overcome disadvantages of other methods applied in this area, such as scanning electron microscope or the atomic force microscope. The main advantages of 3-D laser profilometry include the ease of implementation of the technique and its nondestructive nature, which does not require sample preparation (8-10). Moreover, the technique is reproducible and presents a high degree of freedom in the vertical axes (up to 1000 μm). However, when the paper surface presents a given roughness, if the pen impressions alter the paper with a depth similar to the roughness of medium, the results are not always conclusive (8). It becomes difficult in this case to distinguish which characteristics can be imputed to the pen impressions or the quality of the paper surface. This important limitation is assessed by testing different types of paper of variable quality (of different grammage and finishing) and the writing pressure. The authors will therefore assess the limits of 3-D laser profilometry technique and determine whether the method can overcome such constraints. Second, the authors will investigate the use of digital microscopy because it presents a number of advantages: it is efficient, user-friendly, and provides an objective evaluation and interpretation.
Resumo:
The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning.
Resumo:
In this report, the authors present a case of unusual, accidental methadone intoxication in a 40-year-old man, who had inhaled methadone powder. The drug dealer was a pharmacy technician; methadone had been stolen from a pharmacy and sold as cocaine. After having inhaled methadone powder, he suffered cardiopulmonary arrest. He was admitted to hospital where he died after 24 h of intensive care. The autopsy revealed congestion of internal organs and cerebral and pulmonary edema. Microscopically, the heart showed no changes. The toxicological analyses performed on blood and urine taken at the hospital revealed methadone, cannabinoids, and ethanol. The blood methadone concentration was 290 μg/L. The urine methadone concentration was 160 μg/L. Midazolam and lidocaine, which were administered to the patient at the hospital, were also detected in the blood. The cause of death was determined to be methadone intoxication. The literature has been reviewed and discussed. To date, and to our knowledge, only very few cases of accidental death resulting from methadone inhalation have been described up to the case presented herein.