75 resultados para concil of 100
Resumo:
Purpose: Microphthalmia and anophthalmia are at the severe end of the spectrum of abnormalities in ocular development. A few genes (orthodenticle homeobox 2 [OTX2], retina and anterior neural fold homeobox [RAX], SRY-box 2 [SOX2], CEH10 homeodomain-containing homolog [CHX10], and growth differentiation factor 6 [GDF6]) have been implicated mainly in isolated micro/anophthalmia but causative mutations of these genes explain less than a quarter of these developmental defects. The essential role of the LIM homeobox 2 (LHX2) transcription factor in early eye development has recently been documented. We postulated that mutations in this gene could lead to micro/anophthalmia, and thus performed molecular screening of its sequence in patients having micro/anophthalmia. Methods: Seventy patients having non-syndromic forms of colobomatous microphthalmia (n=25), isolated microphthalmia (n=18), or anophthalmia (n=17), and syndromic forms of micro/anophthalmia (n=10) were included in this study after negative molecular screening for OTX2, RAX, SOX2, and CHX10 mutations. Mutation screening of LHX2 was performed by direct sequencing of the coding sequences and intron/exon boundaries. Results: Two heterozygous variants of unknown significance (c.128C > G [p.Pro43Arg]; c.776C > A [p.Pro259Gln]) were identified in LHX2 among the 70 patients. These variations were not identified in a panel of 100 control patients of mixed origins. The variation c.776C > A (p.Pro259Gln) was considered as non pathogenic by in silico analysis, while the variation c.128C > G (p.Pro43Arg) considered as deleterious by in silico analysis and was inherited from the asymptomatic father. Conclusions: Mutations in LHX2 do not represent a frequent cause of micro/anophthalmia.
Resumo:
We performed an international proficiency study of Human Papillomavirus (HPV) type 16 serology. A common methodology for serology based on virus-like particle (VLP) ELISA was used by 10 laboratories in 6 continents. The laboratories used the same VLP reference reagent, which was selected as the most stable, sensitive and specific VLP preparation out of VLPs donated from 5 different sources. A blinded proficiency panel consisting of 52 serum samples from women with PCR-verified HPV 16-infection, 11 control serum samples from virginal women and the WHO HPV 16 International Standard (IS) serum were distributed. The mean plus 3 standard deviations of the negative control serum samples was the most generally useful "cut-off" criterion for distinguishing positive and negative samples. Using sensitivity of at least 50% and a specificity of 100% as proficiency criteria, 6/10 laboratories were proficient. In conclusion, an international Standard Operating Procedure for HPV serology, an international reporting system in International Units (IU) and a common "cut-off" criterion have been evaluated in an international HPV serology proficiency study.
Resumo:
BACKGROUND: Isolated lung perfusion (ILP) with free and a novel liposomal-encapsulated doxorubicin (Liporubicin, CT Sciences SA, Lausanne, Switzerland) was compared with respect to drug uptake and distribution in rat lungs bearing a sarcomatous tumor. METHODS: A single sarcomatous tumor was generated in the left lung of 39 Fischer rats, followed 10 days later by left-sided ILP (n = 36) with free and equimolar-dosed liposomal doxorubicin at doses of 100 microg (n = 9) and 400 microg (n = 9) for each doxorubicin formulation. In each perfused lung, the drug concentration and distribution were assessed in the tumor and in three areas of normal lung parenchyma by high-performance liquid chromatography (n = 6) and fluorescence microscopy (n = 3). Histologic assessment and immunostaining with von Willebrand factor was performed in 3 animals with untreated tumors. RESULTS: The sarcomatous tumors in controls were well vascularized with fine branching capillaries present throughout the tumors. Isolated lung perfusion resulted in a heterogeneous drug distribution within the perfused lung and a consistently lower drug uptake in tumors than in lung parenchyma for both doxorubicin formulations and both drug doses applied. Isolated lung perfusion with free doxorubicin resulted in a significantly higher drug uptake than Liporubicin in both the tumor and lung tissue for both drug doses applied (p < 0.01). However, the tumor/normal tissue drug ratio was lower for free than for liposomal doxorubicin at a drug dose of 100 microg (0.27 +/- 0.1 vs 0.53 +/- 0.5; p = 0.225) and similar for both doxorubicin formulations at a drug dose of 400 microg (0.67 +/- 0.2 vs 0.54 +/- 0.2; p = 0.335). Both doxorubicin formulations resulted in fluorescence signaling emerging from all tissue compartments of normal lung parenchyma but only in weak and sporadic signaling from the tumors confined to the tumor periphery and vessels situated within the tumor for both drug doses assessed. CONCLUSIONS: Isolated lung perfusion with free and liposomal doxorubicin resulted in a heterogeneous drug distribution within the perfused lung and in a lower drug uptake in tumors than in lung tissue for both doxorubicin formulations and drug doses applied.
Resumo:
PURPOSE: The diagnosis of leptomeningeal metastases is usually confirmed by the finding of malignant cells by cytologic examination in the cerebrospinal fluid (CSF). More sensitive and specific cancer biomarkers may improve the detection of tumor cells in the CSF. Promoter methylation of the human telomerase reverse transcriptase (hTERT) gene characterizes most cancer cells. The aim of this study was to develop a sensitive method to detect hTERT methylation and to explore its use as a cancer biomarker in CSF. EXPERIMENTAL DESIGN: In 77 CSF specimens from 67 patients, hTERT promoter methylation was evaluated using real-time methylation-sensitive high-resolution melting (MS-HRM) and real-time TaqMan PCR and MS-HRM in a single-tube assay. RESULTS: Real-time MS-HRM assay was able to detect down to 1% hTERT-methylated DNA in a background of unmethylated DNA. PCR products were obtained from 90% (69/77) of CSF samples. No false positive hTERT was detected in the 21 non-neoplastic control cases, given to the method a specificity of 100%. The sensitivity of the real-time MS-HRM compared with the cytologic gold standard analysis was of 92% (11/12). Twenty-six CSFs from 22 patients with an hTERT-methylated primary tumor showed cytologic results suspicious for malignancy; in 17 (65%) of them, a diagnosis of leptomeningeal metastases could be confirmed by the hTERT methylation test. CONCLUSION: The hTERT real-time MS-HRM approach is fast, specific, sensitive, and could therefore become a valuable tool for diagnosis of leptomeningeal metastases as an adjunct to the traditional examination of CSF. Clin Cancer Res; 19(8); 2216-23. ©2013 AACR.
Resumo:
Raltegravir (RAL), maraviroc (MVC), darunavir (DRV), and etravirine (ETV) are new antiretroviral agents with significant potential for drug interactions. This work describes a sensitive and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of plasma drug levels. Single-step extraction of RAL, MVC, DRV, ETV and RTV from plasma (100 microl) is performed by protein precipitation using 600 microl of acetonitrile, after the addition of 100 microl darunavir-d(9) (DRV-d(9)) at 1000 ng/ml in MeOH/H(2)O 50/50 as internal standard (I.S.). The mixture is vortexed, sonicated for 10 min, vortex-mixed again and centrifuged. An aliquot of supernatant (150 microl) is diluted 1:1 with a mixture of 20 mM ammonium acetate/MeOH 40/60 and 10 microl is injected onto a 2.1 x 50 mm Waters Atlantis-dC18 3 microm analytical column. Chromatographic separations are performed using a gradient program with 2 mM ammonium acetate containing 0.1% formic acid and acetonitrile with 0.1% formic acid. Analytes quantification is performed by electrospray ionisation-triple quadrupole mass spectrometry using the selected reaction monitoring detection in the positive mode. The method has been validated over the clinically relevant concentrations ranging from 12.5 to 5000 ng/ml, 2.5 to 1000 ng/ml, 25 to 10,000 ng/ml, 10 to 4000 ng/ml, and 5 to 2000 ng/ml for RAL, MRV, DRV, ETV and RTV, respectively. The extraction recovery for all antiretroviral drugs is always above 91%. The method is precise, with mean inter-day CV% within 5.1-9.8%, and accurate (range of inter-day deviation from nominal values -3.3 to +5.1%). In addition our method enables the simultaneous assessment of raltegravir-glucuronide. This is the first analytical method allowing the simultaneous assay of antiretroviral agents targeted to four different steps of HIV replication. The proposed method is suitable for the Therapeutic Drug Monitoring Service of these new regimen combinations administered as salvage therapy to patients having experienced treatment failure, and for whom exposure, tolerance and adherence assessments are critical.
Resumo:
Introduction: Blockade of the renin-angiotensin system is one of the major therapeutic strategies in the management of patients with essential hypertension, congestive heart failure and diabetic as well as non-diabetic renal diseases. As the first angiotensin II receptor blocker (ARB) on the market, losartan belongs to the most frequently prescribed ARB. Area covered : The present review examines the pharmacokinetics of losartan with a special discussion on the dose of losartan that should be used in clinical practice to obtain the maximal benefits of the drug. Readers are provided with arguments suggesting that the dose of 50 mg losartan is probably too low and that losartan should preferably be prescribed at the dose of 100 mg/day or higher. Expert opinion : Losartan is an effective antagonist of angiotensin II AT(1) receptors which has been shown to provide important clinical benefits in patients with hypertension, congestive heart failure and renal diseases. Losartan should be prescribed at the dose of 100 mg/day and the use of higher doses should be reconsidered in future studies to improve its clinical efficacy.
Resumo:
Background and Aims: The international EEsAI study group aims to develop, validate and evaluate the first pediatric EoE activity index (ped-EEsAI). We report on results of phase 1, which aims to generate candidate items. Methods: This study involves 3 phases: (1) item generation, (2) index derivation and testing on a first patient cohort, and (3) validation in a second cohort. In phase 1, item generation, weighting and reduction are achieved through a Delphi process with an international EoE expert group. The experts proposed and ranked candidate items on a 7-point Likert scale (0 = no, 6 = perfect relationship with EoE activity). Results: 23 international EoE experts proposed and ranked 39 items (20 clinical, 6 endoscopic, 8 histologic, 5 laboratory items). Rank order for clinical items: dysphagia related to food consistencies (median 5, range 2-6), severity of dysphagia (5, 3-6), frequency of dysphagia episodes (5, 3-6), regurgitation and vomiting (4, 2-5), response to dietary restrictions (4, 1-6); endoscopic items: whitish exudates (5, 3-6), furrowing (4, 3-6), corrugated rings (4, 2-6), linear shearing (4, 2-6), strictures (3, 2-6); histologic items: intraepithelial eosinophil count (5, 4-6), lamina propria fibrosis (3, 2-6), basal layer enlargement (3, 1-5); laboratory items: % blood eosinophils (3, 0-5). Conclusions: These items will now be reduced in further Delphi rounds, tested on a cohort of 100 pediatric EoE patients and validated in a second independent cohort, resulting in a robust, broadly accepted disease activity index for use in clinical trials and daily care.
Resumo:
OBJECTIVE: To study a new technic of laser treatment of macular holes. METHODS: 21 eyes with stage II-IV macular hole were treated with Argon-green laser. Pigment epithelium in the area of the hole was whitened with spots of 100-200 microns, 100-300 mW. We expected this treatment to create a cellular proliferation that could close and contract the hole. Follow-up after treatment ranged from 3 to 24 months (mean: 9.3 months). RESULTS: Within one month after treatment, the macular hole was closed in 7 eyes (33%) and partially closed in 5 eyes (24%). The visual acuity increased from 1 to 5 lignes (ETDRS chart) in 9 eyes (43%), it remained the same in 9 eyes (43%) and decreased from 1 to 2 lignes in 3 eyes (14%). CONCLUSION: Laser treatment of macular holes seems to be effective and could be proposed as an alternative to the patients who cannot be operated on by vitrectomy and gas tamponade.
Resumo:
Cervical cancer, the second leading cause of cancer mortality in women worldwide, results from infection with a subset of human papillomaviruses (HPV), HPV-16 being the most prevalent type. The available prophylactic vaccines are an effective strategy to prevent this cancer in the long term. However, they only target 70-80% of all cervical cancers and cannot control existing HPV infections and associated lesions. Therapeutic vaccines are thus necessary for women who cannot benefit from prophylactic vaccination. Induction of protective immune responses in the genital mucosa (GM) may be crucial for efficacy of HPV therapeutic vaccines. We report here that mice that received a single subcutaneous (s.c.) vaccination of an adjuvanted long synthetic HPV16 E7(1-98) polypeptide showed induction of 100% tumor protection against s.c. TC-1 tumors and that tumor regression was mainly provided by CD8 T cells. In vivo cytotoxic assay revealed high E7-specific cytolytic T lymphocytes activity in spleen and in genital draining lymph nodes (LN), and E7-specific CD8 T cells could be detected in GM by tetramer staining. More importantly, high-avidity E7-specific INF-gamma secreting CD8 T cells were induced not only in blood, spleen and LN but also in GM of vaccinated mice, thus providing evidence that a parenteral vaccination may be sufficient to provide regression of genital tumors. In addition, there was no correlation between the responses measured in blood with those measured in GM, highlighting the necessity and relevance to determine the immune responses in the mucosa where HPV-tumors reside.
Resumo:
OBJECTIVES: To delineate the various factors contributing to failure or delay in decannulation after partial cricotracheal resection (PCTR) in children. STUDY DESIGN: Case series. SETTING: Academic tertiary medical center. SUBJECTS AND METHODS: A retrospective case review of 100 children who underwent PCTR between 1978 and 2008 for severe subglottic stenosis using an ongoing database. RESULTS: Ninety of 100 (90%) patients were decannulated. Six patients needed secondary tracheostomy. The results of the preoperative evaluation showed grade II stenosis in four patients, grade III in 64 patients, and grade IV in 32 patients. The overall decannulation rate was 100 percent in grade II, 95 percent in grade III, and 78 percent in grade IV stenosis. Fourteen (14%) patients required revision open surgery. The most common cause of revision surgery was posterior glottic stenosis. Partial anastomotic dehiscence was seen in four patients. Delayed decannulation (>1 year) occurred in nine patients. Overall mortality rate in the whole series was 6 percent. No deaths were directly related to the surgery. No iatrogenic recurrent laryngeal nerve injury was present in the entire series. CONCLUSION: Comorbidities and associated syndromes should be addressed before PCTR is planned to improve the final postoperative outcome in terms of decannulation. Perioperative morbidity due to anastomotic dehiscence, to a certain extent, can be avoided by intraoperative judgment in the selection of double-stage surgery when more than five tracheal rings need to be resected. Subglottic stenosis with glottic involvement continues to pose a difficult challenge to pediatric otolaryngologists, often necessitating revision procedures.
Resumo:
Introduction: A new ultra congruent, postero-stabilized total knee arthroplasty (TKA) with a mobile bearing, the FIRST knee prosthesis (Free Insert in Rotation Stabilized in Translation, Symbios SA), was designed and expected to significantly reduce polyethylene wear, to improve the range of motion and the overall stability of the knee while ensuring a physiological ligament balance. Gait analysis has proven to give really objective outcome parameters after lower limb surgery. The goal of our study was to compare the subjective and really objective results of this new TKA with two other widespread models of TKA. Methods: A clinical prospective monocentric cohort study of 100 consecutive patients (47-88 yrs) undergoing a FIRST TKA for primary osteoarthritis is currently being done. Pre- and post-operative follow-ups (6 weeks, 4 months and 1 year) were done with well-recognized subjective evaluations (EQ-5D and WOMAC scores) and semi-objective questionnaires (KSS score and radiography evaluation) as well as with a really objective evaluation using gait parameters from 6 walking trials, performed at different speeds (slow, normal and fast) with an ambulatory gait analysis system (Physilog®, BioAGM CH). The outcomes of the first 32 new TKA after one year of follow-up were compared to the results after 1 year of a randomized controlled clinical trial comparing 29 NexGen® postero-stabilized TKA (Zimmer Inc) with a fixed bearing and 26 NexGen® TKA with a mobile bearing using the same methods. Results: Subjective and semi-objective results were similar for the three types of TKA. As for the really objective parameters, the gait cycle time of the FIRST TKA was statistically significantly shorter at normal speed of walk, as well as double-support periods, as compared to both standard models. The extension (in terms of range of motion when walking) of the operated knee was significantly improved for all three types of walk in favour of the FIRST TKAs compared to both NexGen TKAs. The normal walking speed was significantly higher with faster swing speed and stride lengths for the new TKA. Significantly better coordination scores were observed at normal walking speed for the FIRST TKA as compared to the fixed-bearing TKAs. Conclusion: The FIRST TKAs showed statistically significantly better objective outcomes in terms of gait after one year of follow-up with similar subjective and semi-objective results in comparison with widespread TKA designs. These encouraging short-terms results will have to be confirmed at a 5 years follow-up of the FIRST TKAs.
Resumo:
Background: Chemoembolization is used to treat liver malignancies. However recurrence occurs frequently, possibly because of neoangiogenesis triggered by ischemia caused by the embolic agent. In this context, the combination of an embolic agent with an anti-angiogenic drug seems appealing. This study characterizes the in vitro loading and release profile of sunitinib eluting beads of different sizes and their pharmacokinetic profile in a rabbit model. Methods: 70-150 μm and 100-300 μm drug eluting beads (DC Bead, Biocompatibles UK) were loaded by incubation in a sunitinib hydrochloride solution. Drug was quantified by spectrophotometry at 430 nm. Drug release was measured over one-week periods and normalized using an internal standard in 30% ethanol in NaCl 0.9%. New-Zealand white rabbits were used. Eight animals received 0.2 ml of 100-300 μm DC Bead loaded with 6 mg of sunitinib in the hepatic artery (group 1) and 4 animals received 6 mg of sunitinib p.o. (group 2). Half of the animals were sacrificed after 6 hours and half after24 hours. Liver enzymes were measured at 0, 6 and 24 hours in both groups. Plasmatic sunitinib concentration was determined by tandem mass spectroscopy (LC MS/MS) at 0, 1, 2, 3, 4, 5, 6 and 24 hours. At sacrifice, the livers were harvested and sunitinib concentration in liver tissue was assessed by LC MS/MS. Results: High drug loading was obtained for both microsphere bead sizes. Particle shrinking was observed with adsorption of sunitinib. Almost complete release of sunitinib was detected under physiological conditions, with very similar release for 70-150 μm and 100-300 μm (t50%=1.2 h) DC Bead. Conclusions: Sunitinib eluting beads are well tolerated by rabbits when administered in the hepatic artery. No unexpected toxicity was observed. Very high drug concentration can be obtained at the site of embolization with minimal systemic passage.
Resumo:
A simulation model of the effects of hormone replacement therapy (HRT) on hip fractures and their consequences is based on a population of 100,000 post-menopausal women. This cohort is confronted with literature derived probabilities of cancers (endometrium or breast, which are contra-indications to HRT), hip fracture, disability requiring nursing home or home care, and death. Administration of HRT for life prevents 55,5% of hip fractures, 22,6% of years with home care and 4,4% of years in nursing homes. If HRT is administered for 15 years, these results are 15,5%, 10% and 2,2%, respectively. A slight gain in life expectancy is observed for both durations of HRT. The net financial loss in the simulated population is 222 million Swiss Francs (cost/benefit ratio 1.25) for lifelong administration of HRT, and 153 million Swiss Francs (cost/benefit ratio 1.42) if HRT is administered during 15 years.
Resumo:
In a multicenter study a new, fully automated Roche Diagnostics Elecsys HBsAg II screening assay with improved sensitivity to HBsAg mutant detection was compared to well-established HBsAg tests: AxSYM HBsAg V2 (Abbott), Architect HBsAg (Abbott), Advia Centaur HBsAg (Bayer) Enzygnost HBsAg 5.0 (Dade-Behring), and Vitros Eci HBsAg (Ortho). A total of 16 seroconversion panels, samples of 60 HBsAg native mutants, and 31 HBsAg recombinant mutants, dilution series of NIBSC and PEI standards, 156 HBV positive samples comprising genotypes A to G, 686 preselected HBsAg positive samples from different stages of infection, 3,593 samples from daily routine, and 6,360 unselected blood donations were tested to evaluate the analytical and clinical sensitivity, the detection of mutants, and the specificity of the new assay. Elecsys HBsAg II showed a statistically significant better sensitivity in seroconversion panels to the compared tests. Fifty-seven out of 60 native mutants and all recombinant mutants were found positive. Among 156 HBV samples with different genotypes and 696 preselected HBsAg positive samples Elecsys HBsAg II achieved a sensitivity of 100%. The lower detection limit for NIBSC standard was calculated to be 0.025 IU/ml and for the PEI standards ad and ay it was <0.001 and <0.005 U/ml, respectively. Within 2,724 daily routine specimens and 6.360 unselected blood donations Elecsys HBsAg II showed a specificity of 99.97 and 99.88%, respectively. In conclusion the new Elecsys HBsAg II shows a high sensitivity for the detection of all stages of HBV infection and HBsAg mutants paired together with a high specificity in blood donors, daily routine samples, and potentially interfering sera.
Resumo:
OBJECTIVE: (1) To quantify wear of two different denture tooth materials in vivo with two study designs, (2) to relate tooth variables to vertical loss. METHODS: Two different denture tooth materials had been used (experimental material=test; DCL=control). In study 1 (split-mouth, 6 test centers) 60 subjects received complete dentures, in study 2 (two-arm, 1 test center) 29 subjects. In study 1 the mandibular dentures were supported by implants in 33% of the subjects, in study 2 only in 3% of the subjects. Impressions of the dentures were taken and poured with improved stone at baseline and after 6, 12, 18 and 24 months. Each operator evaluated the wear subjectively. Wear analysis was carried out with a laser scanning device. Maximal vertical loss of the attrition zones was calculated for each tooth cusp and tooth. A mixed linear model was used to statistically analyse the logarithmically transformed wear data. RESULTS: Due to drop-outs and unmatchable casts, only 47 subjects of study 1 and 14 of study 2 completed the 2-year recall. Overall, 75% of all teeth present could be analysed. There was no statistically difference in the overall wear between the test and control material for either study 1 or study 2. The relative increase in wear over time was similar in both study designs. However, a strong subject effect and center effect were observed. The fixed factors included in the model (time, tooth, center, etc.) accounted for 43% of the variability, whereas the random subject effect accounted for another 30% of the variability, leaving about 28% of unexplained variability. More wear was consistently recorded in the maxillary teeth compared to the mandibular teeth and in the first molar teeth compared to the premolar teeth and the second molars. Likewise, the supporting cusps showed more wear than the non-supporting cusps. The amount of wear did not depend on whether or not the lower dentures were supported by implants. The subjective wear was correct in about 67% of the cases if it is postulated that a wear difference of 100μm should be subjectively detectable. SIGNIFICANCE: The clinical wear of denture teeth is highly variable with a strong patient effect. More wear can be expected in maxillary denture teeth compared to mandibular teeth, first molars compared to premolars and supported cusps compared to non-supported cusps. Laboratory data on the wear of denture tooth materials may not be confirmed in well-structured clinical trials probably due to the large inter-individual variability.