77 resultados para cocoa butter equivalent


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to compare two methods used for determining the proper shielding of computed tomography (CT) rooms while considering recent technological advances in CT scanners. The approaches of the German Institute for Standardisation and the US National Council on Radiation Protection and Measurements were compared and a series of radiation measurements were performed in several CT rooms at the Lausanne University Hospital. The following three-step procedure is proposed for assuring sufficient shielding of rooms hosting new CT units with spiral mode acquisition and various X-ray beam collimation widths: (1) calculate the ambient equivalent dose for a representative average weekly dose length product at the position where shielding is required; (2) from the maximum permissible weekly dose at the location of interest, calculate the transmission factor F that must be taken to ensure proper shielding and (3) convert the transmission factor into a thickness of lead shielding. A similar approach could be adopted to use when designing shielding for fluoroscopy rooms, where the basic quantity would be the dose area product instead of the load of current (milliampere-minute).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BackgroundMutations in TNFRSF13B, the gene encoding transmembrane activator and calcium modulator cyclophilin ligand interactor (TACI), are found in 10% of patients with common variable immunodeficiency. However, the most commonly detected mutation is the heterozygous change C104R, which is also found in 0.5% to 1% of healthy subjects. The contribution of the C104R mutation to the B-cell defects observed in patients with common variable immunodeficiency therefore remains unclear.ObjectiveWe sought to define the functional consequences of the C104R mutation on B-cell function.MethodsWe performed in vitro studies of TACI C104R expression and signaling. A knock-in mouse with the equivalent mutation murine TACI (mTACI) C76R was generated as a physiologically relevant model of human disease. We examined homozygous and heterozygous C76R mutant mice alongside wild-type littermates and studied specific B-cell lineages and antibody responses to T cell-independent and T cell-dependent challenge.ResultsC104R expression and ligand binding are significantly diminished when the mutant protein is expressed in 293T cells or in patients' cell lines. This leads to defective nuclear factor κB activation, which is proportionally restored by reintroduction of wild-type TACI. Mice heterozygous and homozygous for mTACI C76R exhibit significant B-cell dysfunction with splenomegaly, marginal zone B-cell expansion, diminished immunoglobulin production and serological responses to T cell-independent antigen, and abnormal immunoglobulin synthesis.ConclusionsThese data show that the C104R mutation and its murine equivalent, C76R, can significantly disrupt TACI function, probably through haploinsufficiency. Furthermore, the heterozygous C76R mutation alone is sufficient to disturb B-cell function with lymphoproliferation and immunoglobulin production defects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The quantity of interest for high-energy photon beam therapy recommended by most dosimetric protocols is the absorbed dose to water. Thus, ionization chambers are calibrated in absorbed dose to water, which is the same quantity as what is calculated by most treatment planning systems (TPS). However, when measurements are performed in a low-density medium, the presence of the ionization chamber generates a perturbation at the level of the secondary particle range. Therefore, the measured quantity is close to the absorbed dose to a volume of water equivalent to the chamber volume. This quantity is not equivalent to the dose calculated by a TPS, which is the absorbed dose to an infinitesimally small volume of water. This phenomenon can lead to an overestimation of the absorbed dose measured with an ionization chamber of up to 40% in extreme cases. In this paper, we propose a method to calculate correction factors based on the Monte Carlo simulations. These correction factors are obtained by the ratio of the absorbed dose to water in a low-density medium □D(w,Q,V1)(low) averaged over a scoring volume V₁ for a geometry where V₁ is filled with the low-density medium and the absorbed dose to water □D(w,QV2)(low) averaged over a volume V₂ for a geometry where V₂ is filled with water. In the Monte Carlo simulations, □D(w,QV2)(low) is obtained by replacing the volume of the ionization chamber by an equivalent volume of water, according to the definition of the absorbed dose to water. The method is validated in two different configurations which allowed us to study the behavior of this correction factor as a function of depth in phantom, photon beam energy, phantom density and field size.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The number of physical activity measures and indexes used in the human literature is large and may result in some difficulty for the average investigator to choose the most appropriate measure. Accordingly, this review is intended to provide information on the utility and limitations of the various measures. Its primary focus is the objective assessment of free-living physical activity in humans based on physiological and biomechanical methods. The physical activity measures have been classified into three categories: Measures based on energy expenditure or oxygen uptake, such as activity energy expenditure, activity-related time equivalent, physical activity level, physical activity ratio, metabolic equivalent, and a new index of potential interest, daytime physical activity level. Measures based on heart rate monitoring, such as net heart rate, physical activity ratio heart rate, physical activity level heart rate, activity-related time equivalent, and daytime physical activity level heart rate. Measures based on whole-body accelerometry (counts/U time). Quantification of the velocity and duration of displacement in outdoor conditions by satellites using the Differential Global Positioning System may constitute a surrogate for physical activity, because walking is the primary activity of man in free-living conditions. A general outline of the measures and indexes described above is presented in tabular form, along with their respective definition, usual applications, advantages, and shortcomings. A practical example is given with typical values in obese and non-obese subjects. The various factors to be considered in the selection of physical activity methods include experimental goals, sample size, budget, cultural and social/environmental factors, physical burden for the subject, and statistical factors, such as accuracy and precision. It is concluded that no single current technique is able to quantify all aspects of physical activity under free-living conditions, requiring the use of complementary methods. In the future, physical activity sensors, which are of low-cost, small-sized, and convenient for subjects, investigators, and clinicians, are needed to reliably monitor, during extended periods in free-living situations, small changes in movements and grade as well as duration and intensity of typical physical activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Physicians who frequently perform fluoroscopic examinations are exposed to high intensity radiation fields. The exposure monitoring is performed with a regular personal dosimeter under the apron in order to estimate the effective dose. However, large parts of the body are not protected by the apron (e.g. arms, head). Therefore, it is recommended to wear a supplemental dosimeter over the apron to obtain a better representative estimate of the effective dose. The over-apron dosimeter can also be used to estimate the eye lens dose. The goal of this study was to investigate the relevance of double dosimetry in interventional radiology. First the calibration procedure of the dosimeters placed over the apron was tested. Then, results of double dosimetry during the last five years were analyzed. We found that the personal dose equivalent measured over a lead apron was underestimated by ∼20% to ∼40% for X-ray beam qualities used in radiology. Measurements made over five-year period confirm that the use of a single under-apron dosimeter is inadequate for personnel monitoring. Relatively high skin dose (>10 mSv/month) would have remained undetected without a second dosimeter placed on the apron.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: To investigate if two distinct, commercially available embryo culture media have a different effect on birthweight and length of singleton term infants conceived after IVF-ICSI. METHODS: University hospital based cohort study. Between 1 January 2000 and 31 December 2004, patients conceiving through IVF-ICSI at the University Hospital, Lausanne have been allocated to two distinct embryo culture media. Only term singleton pregnancies were analysed (n = 525). Data analysis was performed according to two commercially available culture media: Vitrolife (n = 352) versus Cook (n = 173). Analysis was performed through linear regression adjusted for confounders. Media were considered equivalent if the 95% confidence interval lay between -150 g/+150 g. RESULTS: Length, gestational age and distribution of birthweight percentiles did not differ between groups (for both genders). Analysis of the whole cohort, adjusted for a subset of confounders, resulted in a statistically not different mean birthweight between the two groups (Vitrolife +37 g vs Cook, 95%CI: -46 g to 119 g) suggesting equivalence. Adjustment for an enlarged number of confounders in a subsample of patients (n = 258) also revealed no relevant mean birthweight difference of +71 g (95%CI: -45 g to 187 g) in favour of Vitrolife; however, lacking power to prove equivalence. CONCLUSIONS: Our data suggest that significant differences in birthweight due to these two distinct, commercially available embryo culture media are unlikely.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The circumsporozoite protein (CSP), a major antigen of Plasmodium falciparum, was expressed in the slime mold Dictyostelium discoideum. Fusion of the parasite protein to a leader peptide derived from Dictyostelium contact site A was essential for expression. The natural parasite surface antigen, however, was not detected at the slime mold cell surface as expected but retained intracellularly. Removal of the last 23 amino acids resulted in secretion of CSP, suggesting that the C-terminal segment of the CSP, rather than an ectoplasmic domain, was responsible for retention. Cell surface expression was obtained when the CSP C-terminal segment was replaced by the D. discoideum contact site A glycosyl phosphatidylinositol anchor signal sequence. Mice were immunized with Dictyostelium cells harboring CSP at their surface. The raised antibodies recognized two different regions of the CSP. Anti-sporozoite titers of these sera were equivalent to anti-peptide titers detected by enzyme-linked immunosorbent assay. Thus, cell surface targeting of antigens can be obtained in Dictyostelium, generating sporozoite-like cells having potentials for vaccination, diagnostic tests, or basic studies involving parasite cell surface proteins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Asthma is a chronic inflammatory airway disease, characterised by bronchial hyperresponsiveness causing bronchoconstriction, and thereby provoking typical symptoms (dyspnoea, cough, wheezing). Bronchial hyperres- ponsiveness indicates a temporary airflow limitation when exposed to a bronchoconstricting stimulus. Its measurement by challenge tests can be a valuable tool for confirming or excluding asthma, as well as for evaluating the efficacy of treatment. However, the origin of bronchial hyperresponsiveness is multifactorial and the different challenge tests are not equivalent. Direct challenge tests, like methacholine, mainly reflect chronic airway remo- delling, whereas indirect tests, like mannitol, better reflect bronchial inflammation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Human electrophysiological studies support a model whereby sensitivity to so-called illusory contour stimuli is first seen within the lateral occipital complex. A challenge to this model posits that the lateral occipital complex is a general site for crude region-based segmentation, based on findings of equivalent hemodynamic activations in the lateral occipital complex to illusory contour and so-called salient region stimuli, a stimulus class that lacks the classic bounding contours of illusory contours. Using high-density electrical mapping of visual evoked potentials, we show that early lateral occipital cortex activity is substantially stronger to illusory contour than to salient region stimuli, whereas later lateral occipital complex activity is stronger to salient region than to illusory contour stimuli. Our results suggest that equivalent hemodynamic activity to illusory contour and salient region stimuli probably reflects temporally integrated responses, a result of the poor temporal resolution of hemodynamic imaging. The temporal precision of visual evoked potentials is critical for establishing viable models of completion processes and visual scene analysis. We propose that crude spatial segmentation analyses, which are insensitive to illusory contours, occur first within dorsal visual regions, not the lateral occipital complex, and that initial illusory contour sensitivity is a function of the lateral occipital complex.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Master athletes are often considered to represent the ideal rate of decline of aerobic function; however, most of the studies interested in active elderly people are often limited to people younger than 75. We aimed to determine the physiological adaptations and aerobic fitness in a selected European population of active octogenarians during maximal and submaximal exercise tests. Aerobic capacity was measured during maximal incremental tests on treadmill (TR) and cycle-ergometer (CE) and functional capacity during a 6-minute walk test (6-MWT) in 17 subjects aged 81.2 +/- 0.8 years. Pulmonary gas exchange and heart rate (HR) were continuously measured during the different exercise tests. Maximal oxygen consumption (V.O (2max)) on TR and CE was significantly higher than predicted values (TR: 28.7 +/- 1.2 vs. 17 +/- 0.5 ml . kg (-1) . min (-1); CE: 23 +/- 1.2 vs. 16 +/- 0.6 ml . kg (-1) . min (-1) for measured and predicted values respectively). V.O (2max) and HR (max), as well as V.O (2) and HR at the ventilatory threshold (V.O (2)T (V.E) and HR T (V.E)) were significantly higher on TR than on CE (HR (max): 144 +/- 4 vs. 138 +/- 4 bpm; V.O (2)T (V.E): 22.5 +/- 0.8 vs. 17.7 +/- 0.9 ml . kg (-1) . min (-1) for TR and CE respectively). V.O (2)T (V.E) and HR T (V.E) on TR were equivalent to V.O (2) and HR measured during the 6-MWT. HR T (V.E) on TR and mean HR during the 6-MWT were strongly correlated (R = 0.82, p < 0.01). Maintenance of regular physical activity provides high aerobic fitness, in octogenarians, as was shown by the higher values of our subjects in comparison to predicted values. Moreover, the close relation between the intensity developed at T (V.E) on TR and 6-MWT could support the idea that a walk test is a submaximal test performed at high intensity that could provide a basis for exercise prescription in an individualized manner in active elderly people.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Summary.  The outcome of hepatitis C virus (HCV) infection and the likelihood of a sustained virological response (SVR) to antiviral therapy depends on both viral and host characteristics. In vitro studies demonstrated that bile acids (BA) interfere with antiviral interferon effects. We investigate the influence of plasma BA concentrations and an ABCB11 polymorphism associated with lower transporter expression on viral load and SVR. Four hundred and fifty-one Caucasian HCV-patients treated with PEG-interferon and ribavirin were included in the study. ABCB11 1331T>C was genotyped, and plasma BA levels were determined. The 1331C allele was slightly overrepresented in HCV-patients compared to controls. In HCV-patients, a significant difference between patients achieving SVR vs non-SVR was observed for HCV-2/3 (5 vs 9 μm; P = 0.0001), while median BA levels in HCV-1 were marginally elevated. Normal BA levels <8 μm were significantly associated with SVR (58.3%vs 36.3%; OR 2.48; P = 0.0001). This difference was significant for HCV-2/3 (90.7%vs 67.6%; P = 0.002) but marginal in HCV-1 (38.7%vs 27.8%; P = 0.058). SVR rates were equivalent between ABCB11 genotypes for HCV-1, but increased for HCV-2/3 (TT 100%vs CC 78%; OR 2.01; P = 0.043). IL28B genotype had no influence on these associations. No correlation between BA levels and HCV RNA was detected for any HCV genotype. The higher allelic frequency of ABCB11 1331C in HCV-patients compared to controls may indirectly link increased BA to HCV chronicity. Our data support a role for BA as host factor affecting therapy response in HCV-2/3 patients, whereas a weaker association was found for HCV-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article seeks to explain the pattern of delegation to independent regulatory agencies in Western Europe. Two types of arguments are advanced to explain variations in the formal independence of regulators. Firstly, the need for governments to increase their credible commitment capacity may lead them to delegate regulation to an agency that is partly beyond their direct control. Secondly, delegation may be a response to the political uncertainty problem, which arises when governments are afraid of being replaced by another coalition with different preferences, which could decide to change existing policy choices. In addition, veto players may constitute a functional equivalent of delegation, since they influence policy stability and therefore tend to mitigate both the credibility and the political uncertainty problems. These arguments are consistent with the results of the empirical analysis of the formal independence of regulators in seventeen countries and seven sectors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose:To report the functional, anatomic outcome and safety profile of 23-gauge pars plana vitrectomy (PPV) combined with peeling and intravitreal injection of triamcinolone acetonide (TA) in eyes with idiopathic epiretinal membranes (ERM). Methods:Retrospective, nonrandomized study of consecutive patients who underwent 23-gauge transconjunctival sutureless PPV with subsequent membrane peeling and intravitreal TA injection for an idiopathic ERM. All patients were operated between February 2007 and February 2008 at the Jules Gonin University Eye Hospital. The minimum follow-up was 6-months. Results:Thirty-nine eyes of 39 patients were included. The mean follow-up was 7 months (SD: 2.2, range: 6-15 months). Twenty-two (56%) eyes were pseudophakic and 17 (44%) were phakic at the time of surgery. Mean preoperative intraocular pressure (IOP) was 14 mmHg (SD: 3.5). At the final follow-up mean IOP was 14.5 (SD: 2.7) that did not differ significantly from the IOP at baseline (P: 0.14- 2-tailed t test). Five patients (13%) needed temporary topical anti-glaucoma treatment.Mean preoperative BCVA was 0.28 decimal equivalent (logMAR 0.54, SD: 0.2, range: 1.0 - 0.2). and improved significantly (P <0.0001, 2-tailed t test) to a mean of 0.6 decimal equivalent (logMAR 0.22, SD: 0.16, range: 0.6 - 0) at the final follow-up. The visual acuity improved by a mean of 3.2 lines (SD 2.1, range 0- 8). Twenty-nine patients (74%) demonstrated a gain of 3 or more lines.Mean central macular thickness (CMT) was 456 µm (SD: 77) at the baseline that reduced significantly (P <0.0001, 2-tailed t test) at the final follow-up to 327µm (SD: 79). Average CMT reduction was 131µm (SD: 77, range: 36- 380 µm). A subgroup analysis of 15 selected cases that had CMT measurement 1 week after surgery demonstrated that 84% of the total final reduction in CMT occurred during the first week. Conclusions:23-gauge sutureless transconjunctival vitrectomy with the concomitant administration of intravitreal TA is a safe and effective technique for the treatment of idiopathic ERM and may speed up anatomical recovery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A solution of (18)F was standardised with a 4pibeta-4pigamma coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this (18)F solution were also measured using 4pigamma NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Système International de Référence through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The (18)F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The geometry and connectivity of fractures exert a strong influence on the flow and transport properties of fracture networks. We present a novel approach to stochastically generate three-dimensional discrete networks of connected fractures that are conditioned to hydrological and geophysical data. A hierarchical rejection sampling algorithm is used to draw realizations from the posterior probability density function at different conditioning levels. The method is applied to a well-studied granitic formation using data acquired within two boreholes located 6 m apart. The prior models include 27 fractures with their geometry (position and orientation) bounded by information derived from single-hole ground-penetrating radar (GPR) data acquired during saline tracer tests and optical televiewer logs. Eleven cross-hole hydraulic connections between fractures in neighboring boreholes and the order in which the tracer arrives at different fractures are used for conditioning. Furthermore, the networks are conditioned to the observed relative hydraulic importance of the different hydraulic connections by numerically simulating the flow response. Among the conditioning data considered, constraints on the relative flow contributions were the most effective in determining the variability among the network realizations. Nevertheless, we find that the posterior model space is strongly determined by the imposed prior bounds. Strong prior bounds were derived from GPR measurements and helped to make the approach computationally feasible. We analyze a set of 230 posterior realizations that reproduce all data given their uncertainties assuming the same uniform transmissivity in all fractures. The posterior models provide valuable statistics on length scales and density of connected fractures, as well as their connectivity. In an additional analysis, effective transmissivity estimates of the posterior realizations indicate a strong influence of the DFN structure, in that it induces large variations of equivalent transmissivities between realizations. The transmissivity estimates agree well with previous estimates at the site based on pumping, flowmeter and temperature data.