77 resultados para antioxidant power
Resumo:
OBJECTIVE: Enteral glutamine supplementation and antioxidants have been shown to be beneficial in some categories of critically ill patients. This study investigated the impact on organ function and clinical outcome of an enteral solution enriched with glutamine and antioxidant micronutrients in patients with trauma and with burns. METHODS: This was a prospective study of a historical control group including critically ill, burned and major trauma patients (n = 86, 40 patients with burns and 46 with trauma, 43 in each group) on admission to an intensive care unit in a university hospital (matching for severity, age, and sex). The intervention aimed to deliver a 500-mL enteral solution containing 30 g of glutamine per day, selenium, zinc, and vitamin E (Gln-AOX) for a maximum of 10 d, in addition to control treatment consisting of enteral nutrition in all patients and intravenous trace elements in all burn patients. RESULTS: Patients were comparable at baseline, except for more inhalation injuries in the burn-Gln-AOX group (P = 0.10) and greater neurologic impairment in the trauma-Gln-AOX group (P = 0.022). Intestinal tolerance was good. The full 500-mL dose was rarely delivered, resulting in a low mean glutamine daily dose (22 g for burn patients and 16 g for trauma patients). In burn patients intravenous trace element delivery was superior to the enteral dose. The evolution of the Sequential Organ Failure Assessment score and other outcome variables did not differ significantly between groups. C-reactive protein decreased faster in the Gln-AOX group. CONCLUSION: The Gln-AOX supplement was well tolerated in critically ill, injured patients, but did not improve outcome significantly. The delivery of glutamine below the 0.5-g/kg recommended dose in association with high intravenous trace element substitution doses in burn patients are likely to have blunted the impact by not reaching an efficient treatment dose. Further trials testing higher doses of Gln are required.
Resumo:
We characterize the value function of maximizing the total discounted utility of dividend payments for a compound Poisson insurance risk model when strictly positive transaction costs are included, leading to an impulse control problem. We illustrate that well known simple strategies can be optimal in the case of exponential claim amounts. Finally we develop a numerical procedure to deal with general claim amount distributions.
Resumo:
INTRODUCTION: To compare the power spectral changes of the voluntary surface electromyogram (sEMG) and of the compound action potential (M wave) in the vastus medialis and vastus lateralis muscles during fatiguing contractions. METHODS: Interference sEMG and force were recorded during 48 intermittent 3-s isometric maximal voluntary contractions (MVC) from 13 young, healthy subjects. M waves and twitches were evoked using supramaximal femoral nerve stimulation between the successive MVCs. Mean frequency (F mean), and median frequency were calculated from the sEMG and M waves. Muscle fiber conduction velocity (MFCV) was computed by cross-correlation. RESULTS: The power spectral shift to lower frequencies was significantly greater for the voluntary sEMG than for the M waves (P < 0.05). Over the fatiguing protocol, the overall average decrease in MFCV (~25 %) was comparable to that of sEMG F mean (~22 %), but significantly greater than that of M-wave F mean (~9 %) (P < 0.001). The mean decline in MFCV was highly correlated with the mean decreases in both sEMG and M-wave F mean. CONCLUSIONS: The present findings indicated that, as fatigue progressed, central mechanisms could enhance the relative weight of the low-frequency components of the voluntary sEMG power spectrum, and/or the end-of-fiber (non-propagating) components could reduce the sensitivity of the M-wave spectrum to changes in conduction velocity.
Resumo:
PURPOSE: This descriptive article illustrates the application of Global Positioning System (GPS) professional receivers in the field of locomotion studies. The technological challenge was to assess the external mechanical work in outdoor walking. METHODS: Five subjects walked five times during 5 min on an athletic track at different imposed stride frequency (from 70-130 steps x min(-1)). A differential GPS system (carrier phase analysis) measured the variation of the position of the trunk at 5 Hz. A portable indirect calorimeter recorded breath-by-breath energy expenditure. RESULTS: For a walking speed of 1.05 +/- 0.11 m x s(-1), the vertical lift of the trunk (43 +/- 14 mm) induced a power of 46.0 +/- 20.4 W. The average speed variation per step (0.15 +/- 0.03 m x s(-1)) produced a kinetic power of 16.9 +/- 7.2 W. As compared with commonly admitted values, the energy exchange (recovery) between the two energy components was low (39.1 +/- 10.0%), which induced an overestimated mechanical power (38.9 +/- 18.3 W or 0.60 W x kg(-1) body mass) and a high net mechanical efficiency (26.9 +/- 5.8%). CONCLUSION: We assumed that the cause of the overestimation was an unwanted oscillation of the GPS antenna. It is concluded that GPS (in phase mode) is now able to record small body movements during human locomotion, and constitutes a promising tool for gait analysis of outdoor unrestrained walking. However, the design of the receiver and the antenna must be adapted to human experiments and a thorough validation study remains to be conducted.
Resumo:
The noise power spectrum (NPS) is the reference metric for understanding the noise content in computed tomography (CT) images. To evaluate the noise properties of clinical multidetector (MDCT) scanners, local 2D and 3D NPSs were computed for different acquisition reconstruction parameters.A 64- and a 128-MDCT scanners were employed. Measurements were performed on a water phantom in axial and helical acquisition modes. CT dose index was identical for both installations. Influence of parameters such as the pitch, the reconstruction filter (soft, standard and bone) and the reconstruction algorithm (filtered-back projection (FBP), adaptive statistical iterative reconstruction (ASIR)) were investigated. Images were also reconstructed in the coronal plane using a reformat process. Then 2D and 3D NPS methods were computed.In axial acquisition mode, the 2D axial NPS showed an important magnitude variation as a function of the z-direction when measured at the phantom center. In helical mode, a directional dependency with lobular shape was observed while the magnitude of the NPS was kept constant. Important effects of the reconstruction filter, pitch and reconstruction algorithm were observed on 3D NPS results for both MDCTs. With ASIR, a reduction of the NPS magnitude and a shift of the NPS peak to the low frequency range were visible. 2D coronal NPS obtained from the reformat images was impacted by the interpolation when compared to 2D coronal NPS obtained from 3D measurements.The noise properties of volume measured in last generation MDCTs was studied using local 3D NPS metric. However, impact of the non-stationarity noise effect may need further investigations.
Resumo:
Migration partnerships (MPs) have become a key instrument in global migration governance. In contrast to traditional unilateral approaches, MPs emphasize a more comprehensive and inclusive tackling of migration issues between countries of origin, transit, and destination. Due to this cooperation-oriented concept, most of the existing studies on MPs neglect power questions within partnerships in line with the official discourse, reflecting a broader trend in the international migration governance literature. Others take an instrumentalist view in analysing the power of partnerships or focus on soft power. Illustrated with the examples of the European Mobility Partnerships (EU MPs) and the Swiss Migration Partnerships (CH MPs), we conduct an analysis based on a concept of productive power drawing on post-structural and post-colonial insights. Our main argument is that in contrast to their seemingly consent-oriented and technical character, MPs are sites of intense (discursive) struggles, and (re-)produce meanings, subjects, and resistances. A productive power analysis allows us to move beyond the dichotomy in the literature between coercion and cooperation, as well as between power and resistance more broadly.
Resumo:
When decommissioning a nuclear facility it is important to be able to estimate activity levels of potentially radioactive samples and compare with clearance values defined by regulatory authorities. This paper presents a method of calibrating a clearance box monitor based on practical experimental measurements and Monte Carlo simulations. Adjusting the simulation for experimental data obtained using a simple point source permits the computation of absolute calibration factors for more complex geometries with an accuracy of a bit more than 20%. The uncertainty of the calibration factor can be improved to about 10% when the simulation is used relatively, in direct comparison with a measurement performed in the same geometry but with another nuclide. The simulation can also be used to validate the experimental calibration procedure when the sample is supposed to be homogeneous but the calibration factor is derived from a plate phantom. For more realistic geometries, like a small gravel dumpster, Monte Carlo simulation shows that the calibration factor obtained with a larger homogeneous phantom is correct within about 20%, if sample density is taken as the influencing parameter. Finally, simulation can be used to estimate the effect of a contamination hotspot. The research supporting this paper shows that activity could be largely underestimated in the event of a centrally-located hotspot and overestimated for a peripherally-located hotspot if the sample is assumed to be homogeneously contaminated. This demonstrates the usefulness of being able to complement experimental methods with Monte Carlo simulations in order to estimate calibration factors that cannot be directly measured because of a lack of available material or specific geometries.
Resumo:
An increased oxidative stress and alteration of the antioxidant systems have been observed in schizophrenia. Glutathione (GSH), a major redox regulator, is decreased in patients' cerebrospinal fluid, prefrontal cortex in vivo and striatum post-mortem tissue. Most importantly, there is genetic and functional evidence for the implication of the gene of the glutamate cysteine ligase (GCL) catalytic subunit, the key GSH-synthesizing enzyme. We have developed animal models for a GSH deficit to study the consequences of such deficit on the brain development. A GSH deficit combined with elevated dopamine (DA) during development leads to reduced parvalbumin (PV) expression in a subclass of GABA interneurons in rat anterior cingulate cortex (ACC). Similar changes are observed in postmortem brain tissue of schizophrenic patients. GSH dysregulation increases vulnerability to oxidative stress, that in turn could lead to cortical circuit anomalies in the schizophrenic brain. In the present study, we use a GCL modulatory subunit (GCLM) knock-out (KO) mouse model that presents up to 80% decreased brain GSH levels. During postnatal development, a subgroup of animals from each genotype is exposed to elevated oxidative stress induced by treatment with the DA reuptake inhibitor GBR12909. Results reveal a significant genotype-specific delay International Congress on Schizophrenia Research 136 10. 10. Neuroanatomy, Animal Downloaded from http://schizophreniabulletin.oxfordjournals.org at Bibliotheque Cantonale et Universitaire on June 18, 2010 in cortical PV expression at postnatal day P10 in GCLM-KO mice, as compared to wild-type. This effect seems to be further exaggerated in animals treated with GBR12909 from P5 to P10. At P20, PV expression is no longer significantly reduced in GCLM-KO ACC without GBR but is reduced if GBR is applied from P10 to P20. However, our result show that GCLM-KO mice exhibit increased oxidative stress, cortical altered myelin development as shown by MBP marker, and more specifically impairment of the peri-neuronal net known to modulate PV connectivity. In addition, we also observe a reduced PV expression in the ventro-temporal hippocampus of adult GCLM-KO mice, suggesting that anomalies of the PV interneurons prevail at least in some brain regions throughout the adulthood. Interestingly, the power of kainate-induced gamma oscillations, known to be dependent on proper activation of PV interneuron's, is also lower in hippocampal slices of adult GCLM KO mice. These results suggest that the PV positive GABA interneurons is particularly vulnerable to increased oxidative stress
Resumo:
Positive selection is widely estimated from protein coding sequence alignments by the nonsynonymous-to-synonymous ratio omega. Increasingly elaborate codon models are used in a likelihood framework for this estimation. Although there is widespread concern about the robustness of the estimation of the omega ratio, more efforts are needed to estimate this robustness, especially in the context of complex models. Here, we focused on the branch-site codon model. We investigated its robustness on a large set of simulated data. First, we investigated the impact of sequence divergence. We found evidence of underestimation of the synonymous substitution rate for values as small as 0.5, with a slight increase in false positives for the branch-site test. When dS increases further, underestimation of dS is worse, but false positives decrease. Interestingly, the detection of true positives follows a similar distribution, with a maximum for intermediary values of dS. Thus, high dS is more of a concern for a loss of power (false negatives) than for false positives of the test. Second, we investigated the impact of GC content. We showed that there is no significant difference of false positives between high GC (up to similar to 80%) and low GC (similar to 30%) genes. Moreover, neither shifts of GC content on a specific branch nor major shifts in GC along the gene sequence generate many false positives. Our results confirm that the branch-site is a very conservative test.