57 resultados para Virtual materials
Resumo:
Context: Ovarian tumors (OT) typing is a competency expected from pathologists, with significant clinical implications. OT however come in numerous different types, some rather rare, with the consequence of few opportunities for practice in some departments. Aim: Our aim was to design a tool for pathologists to train in less common OT typing. Method and Results: Representative slides of 20 less common OT were scanned (Nano Zoomer Digital Hamamatsu®) and the diagnostic algorithm proposed by Young and Scully applied to each case (Young RH and Scully RE, Seminars in Diagnostic Pathology 2001, 18: 161-235) to include: recognition of morphological pattern(s); shortlisting of differential diagnosis; proposition of relevant immunohistochemical markers. The next steps of this project will be: evaluation of the tool in several post-graduate training centers in Europe and Québec; improvement of its design based on evaluation results; diffusion to a larger public. Discussion: In clinical medicine, solving many cases is recognized as of utmost importance for a novice to become an expert. This project relies on the virtual slides technology to provide pathologists with a learning tool aimed at increasing their skills in OT typing. After due evaluation, this model might be extended to other uncommon tumors.
Resumo:
BACKGROUND: Several European HIV observational data bases have, over the last decade, accumulated a substantial number of resistance test results and developed large sample repositories, There is a need to link these efforts together, We here describe the development of such a novel tool that allows to bind these data bases together in a distributed fashion for which the control and data remains with the cohorts rather than classic data mergers.METHODS: As proof-of-concept we entered two basic queries into the tool: available resistance tests and available samples. We asked for patients still alive after 1998-01-01, and between 180 and 195 cm of height, and how many samples or resistance tests there would be available for these patients, The queries were uploaded with the tool to a central web server from which each participating cohort downloaded the queries with the tool and ran them against their database, The numbers gathered were then submitted back to the server and we could accumulate the number of available samples and resistance tests.RESULTS: We obtained the following results from the cohorts on available samples/resistance test: EuResist: not availableI11,194; EuroSIDA: 20,71611,992; ICONA: 3,751/500; Rega: 302/302; SHCS: 53,78311,485, In total, 78,552 samples and 15,473 resistance tests were available amongst these five cohorts. Once these data items have been identified, it is trivial to generate lists of relevant samples that would be usefuI for ultra deep sequencing in addition to the already available resistance tests, Saon the tool will include small analysis packages that allow each cohort to pull a report on their cohort profile and also survey emerging resistance trends in their own cohort,CONCLUSIONS: We plan on providing this tool to all cohorts within the Collaborative HIV and Anti-HIV Drug Resistance Network (CHAIN) and will provide the tool free of charge to others for any non-commercial use, The potential of this tool is to ease collaborations, that is, in projects requiring data to speed up identification of novel resistance mutations by increasing the number of observations across multiple cohorts instead of awaiting single cohorts or studies to reach the critical number needed to address such issues.
Resumo:
PURPOSE: Laparoscopic surgery represents specific challenges, such as the reduction of a three-dimensional anatomic environment to two dimensions. The aim of this study was to investigate the impact of the loss of the third dimension on laparoscopic virtual reality (VR) performance. METHODS: We compared a group of examinees with impaired stereopsis (group 1, n = 28) to a group with accurate stereopsis (group 2, n = 29). The primary outcome was the difference between the mean total score (MTS) of all tasks taken together and the performance in task 3 (eye-hand coordination), which was a priori considered to be the most dependent on intact stereopsis. RESULTS: The MTS and performance in task 3 tended to be slightly, but not significantly, better in group 2 than in group 1 [MTS: -0.12 (95 % CI -0.32, 0.08; p = 0.234); task 3: -0.09 (95 % CI -0.29, 0.11; p = 0.385)]. The difference of MTS between simulated impaired stereopsis between group 2 (by attaching an eye patch on the adominant eye in the 2nd run) and the first run of group 1 was not significant (MTS: p = 0.981; task 3: p = 0.527). CONCLUSION: We were unable to demonstrate an impact of impaired examinees' stereopsis on laparoscopic VR performance. Individuals with accurate stereopsis seem to be able to compensate for the loss of the third dimension in laparoscopic VR simulations.
Resumo:
Thegoalofthepresentreviewistoexplainhowimmersivevirtualenvironmenttechnology(IVET)canbeusedforthestudyofsocialinteractionsandhowtheuseofvirtualhumansinimmersivevirtualenvironmentscanadvanceresearchandapplicationinmanydifferentfields.Researchersstudyingindividualdifferencesinsocialinteractionsaretypicallyinterestedinkeepingthebehaviorandtheappearanceoftheinteractionpartnerconstantacrossparticipants.WithIVETresearchershavefullcontrolovertheinteractionpartners,canstandardizethemwhilestillkeepingthesimulationrealistic.Virtualsimulationsarevalid:growingevidenceshowsthatindeedstudiesconductedwithIVETcanreplicatesomewell-knownfindingsofsocialpsychology.Moreover,IVETallowsresearcherstosubtlymanipulatecharacteristicsoftheenvironment(e.g.,visualcuestoprimeparticipants)orofthesocialpartner(e.g.,his/herrace)toinvestigatetheirinfluencesonparticipants'behaviorandcognition.Furthermore,manipulationsthatwouldbedifficultorimpossibleinreallife(e.g.,changingparticipants'height)canbeeasilyobtainedwithIVET.Besidetheadvantagesfortheoreticalresearch,weexplorethemostrecenttrainingandclinicalapplicationsofIVET,itsintegrationwithothertechnologies(e.g.,socialsensing)andfuturechallengesforresearchers(e.g.,makingthecommunicationbetweenvirtualhumansandparticipantssmoother).
Resumo:
Understanding molecular recognition is one major requirement for drug discovery and design. Physicochemical and shape complementarity between two binding partners is the driving force during complex formation. In this study, the impact of shape within this process is analyzed. Protein binding pockets and co-crystallized ligands are represented by normalized principal moments of inertia ratios (NPRs). The corresponding descriptor space is triangular, with its corners occupied by spherical, discoid, and elongated shapes. An analysis of a selected set of sc-PDB complexes suggests that pockets and bound ligands avoid spherical shapes, which are, however, prevalent in small unoccupied pockets. Furthermore, a direct shape comparison confirms previous studies that on average only one third of a pocket is filled by its bound ligand, supplemented by a 50 % subpocket coverage. In this study, we found that shape complementary is expressed by low pairwise shape distances in NPR space, short distances between the centers-of-mass, and small deviations in the angle between the first principal ellipsoid axes. Furthermore, it is assessed how different binding pocket parameters are related to bioactivity and binding efficiency of the co-crystallized ligand. In addition, the performance of different shape and size parameters of pockets and ligands is evaluated in a virtual screening scenario performed on four representative targets.
Resumo:
In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been used successfully in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits; to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles.
Resumo:
In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been successfully used in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits, to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles.
Resumo:
Background Virtual reality (VR) simulation is increasingly used in surgical disciplines. Since VR simulators measure multiple outcomes, standardized reporting is needed. Methods We present an algorithm for combining multiple VR outcomes into dimension summary measures, which are then integrated into a meaningful total score. We reanalyzed the data of two VR studies applying the algorithm. Results The proposed algorithm was successfully applied to both VR studies. Conclusions The algorithm contributes to standardized and transparent reporting in VR-related research.
Resumo:
This study aimed at comparing the efficiency of various sampling materials for the collection and subsequent analysis of organic gunshot residues (OGSR). To the best of our knowledge, it is the first time that sampling devices were investigated in detail for further quantitation of OGSR by LC-MS. Seven sampling materials, namely two "swab"-type and five "stub"-type collection materials, were tested. The investigation started with the development of a simple and robust LC-MS method able to separate and quantify molecules typically found in gunpowders, such as diphenylamine or ethylcentralite. The evaluation of sampling materials was then systematically carried out by first analysing blank extracts of the materials to check for potential interferences and determining matrix effects. Based on these results, the best four materials, namely cotton buds, polyester swabs, a tape from 3M and PTFE were compared in terms of collection efficiency during shooting experiments using a set of 9 mm Luger ammunition. It was found that the tape was capable of recovering the highest amounts of OGSR. As tape-lifting is the technique currently used in routine for inorganic GSR, OGSR analysis might be implemented without modifying IGSR sampling and analysis procedure.