78 resultados para VALVES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Transcatheter aortic valve replacement (TAVR) provides good results in selected high-risk patients. However, it is unclear whether this procedure carries advantages in extreme-risk profile patients with logistic EuroSCORE above 35%. METHODS: From January 2009 to July 2011, of a total number of 92 transcatheter aortic valve procedures performed, 40 'extreme-risk' patients underwent transapical TAVR (TA-TAVR) (EuroSCORE above 35%). Variables were analysed as risk factors for hospital and mid-term mortality, and a 2-year follow-up (FU) was obtained. RESULTS: The mean age was: 81 ± 10 years. Twelve patients (30%) had chronic pulmonary disease, 32 (80%) severe peripheral vascular disease, 14 (35%) previous cardiac surgery, 19 (48%) chronic renal failure (2 in dialysis), 7 (17%) previous stroke (1 with disabilities), 3 (7%) a porcelain aorta and 12 (30%) were urgent cases. Mean left ventricle ejection fraction (LVEF) was 49 ± 13%, and mean logistic EuroSCORE was 48 ± 11%. Forty stent-valves were successfully implanted with six Grade-1 and one Grade-2 paravalvular leakages (success rate: 100%). Hospital mortality was 20% (8 patients). Causes of death following the valve academic research consortium (VARC) definitions were: life-threatening haemorrhage (1), myocardial infarction (1), sudden death (1), multiorgan failure (2), stroke (1) and severe respiratory dysfunction (2). Major complications (VARC definitions) were: myocardial infarction for left coronary ostium occlusion (1), life-threatening bleeding (2), stroke (2) and acute kidney injury with dialysis (2). Predictors for hospital mortality were: conversion to sternotomy, life-threatening haemorrhage, postoperative dialysis and long intensive care unit (ICU) stay. Variables associated with hospital mortality were: conversion to sternotomy (P = 0.03), life-threatening bleeding (P = 0.02), acute kidney injury with dialysis (P = 0.03) and prolonged ICU stay (P = 0.02). Mean FU time was 24 months: actuarial survival estimates for all-cause mortality at 6 months, 1 year, 18 months and 2 years were 68, 57, 54 and 54%, respectively. Patients still alive at FU were in good clinical condition, New York Heart Association (NYHA) class 1-2 and were never rehospitalized for cardiac decompensation. CONCLUSIONS: TA-TAVR in extreme-risk patients carries a moderate risk of hospital mortality. Severe comorbidities and presence of residual paravalvular leakages affect the mid-term survival, whereas surviving patients have an acceptable quality of life without rehospitalizations for cardiac decompensation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Little is known about the stent deformability required for optimal stented heart valve bioprosthesis design. Therefore, two bioprosthetic valves with known good long-term clinical results were tested. The strain in the radial direction of the stent posts of these valves was compared with contemporary bioprosthetic valves and a native porcine aortic root. METHODS Medtronic Intact and Carpentier-Edwards Standard (CES), and four contemporary bioprostheses, including one self-expanding prosthesis, were tested with three sonomicrometry probes per valve fixed at commissure attachment points. The mean values from 2400 data points from three measurements of the interprobe distances were used to calculate the radius of the circle circumscribed around the three probes. Changes in the radius of the aortic root at pressures 70-90 and 120-140 mmHg (pressure during diastole and systole) and that of the stent posts at 70-90 and 0-10 mmHg (transvalvular pressure gradient during diastole and systole) were compared. RESULTS An increase in radius by 7.3 ± 2.6, 8.7 ± 0.0 and 3.9 ± 0.0% for the porcine aortic root, CES and Intact valves, respectively, was observed during transition from diastolic to systolic pressure and less for contemporary bioprostheses-mean 2.5 ± 0.9%, lowest 1.2 ± 0.0. CONCLUSIONS The results indicate that the radial deformability of bioprosthetic valve stent posts can be as low as 1.2% for xenoaortic and 3.0% for xenopericardial prostheses with no compromise of valve durability. Although these results suggest that valve stent post-deformability might not be of critical importance, a concrete answer to the question of the significance of stent deformability for valve durability can be obtained only by acquiring long-term follow-up results for valve prostheses with rigid stents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Papillary fibroelastomas (PFE) are benign endocardial masses and generally originate from the cardiac valves, while PFE arising from the ascending thoracic aorta are an uncommon clinical finding. We report the case of a 78-year-old female who presented to the emergency department with an acute ST segment elevation myocardial infarction. Urgent coronary angiography showed no significant coronary artery obstructive disease but left ventriculography revealed the presence of a highly mobile mass located in the proximal portion of the ascending thoracic aorta. We postulated that the clinical symptoms were caused by embolization from the aortic mass and surgical excision of the peduncle was performed. Histopathological examination revealed a PFE with thrombotic material. Nowadays, surgical excision of PFE remains, the treatment of choice for symptomatic patients with excellent short- and long-term results but recurrence of PFE following surgical excision has not been reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lung volume reduction with valves is increasingly used to treat selected patients with severe emphysema. The indications for this procedure have been previously described; however, its contraindications have not yet been conclusively established. This case highlights the potentially severe complications of endobronchial one-way valve placement in the setting of a previous pleurodesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many studies in continental areas have successfully used the oxygen isotope composition of fossil ostracod valves to reconstruct past hydrological conditions associated with large changes in climate. Yet, ostracods are known to crystallise their valves out of isotopic equilibrium for oxygen and they generally have higher 18O contents compared to inorganic calcite grown at equilibrium under the same condi- tions. A review of vital offsets determined for continental ostracods indicates that vital offsets might change from site to site, questioning a potential influence of environmental conditions on oxygen isotope fractionation in ostracods. Results from the literature suggest that pH has no influence on ostracod vital offset. A re-evaluation of results from Li and Liu (J Paleolimnol 43:111-120, 2010) suggests that salin- ity may influence oxygen isotope fractionation in ostracods, with lower vital offsets for higher salinities. Such a relationship was also observed for the vital offsets determined by Chivas et al. (The ostracoda- applications in quaternary research. American Geo- physical Union, Washington, DC, 2002). Yet, when results of all studies are compiled, the correlation between vital offsets and salinity is low while the correlation between vital offsets and host water Mg/Ca is higher, suggesting that ionic composition of water and/or relative abundance of major ions may also control oxygen isotope fractionation in ostracods. Lack of data on host water ionic composition for the different studies precludes more detailed examination at this stage. Further studies such as natural or laboratory cultures done under strictly controlled conditions are needed to better understand the potential influence of varying environmental condi- tions on oxygen isotope compositions of ostracod valves.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The expression of Staphylococcus aureus adhesins in Lactococcus lactis identified clumping factor A (ClfA) and fibronectin-binding protein A (FnBPA) as critical for valve colonization in rats with experimental endocarditis. This study further analyzed their role in disease evolution. Infected animals were followed for 3 d. ClfA-positive lactococci successfully colonized damaged valves, but were spontaneously eradicated over 48 h. In contrast, FnBPA-positive lactococci progressively increased bacterial titers in vegetations and spleens. At imaging, ClfA-positive lactococci were restricted to the vegetations, whereas FnBPA-positive lactococci also invaded the adjacent endothelium. This reflected the capacity of FnBPA to trigger cell internalization in vitro. Because FnBPA carries both fibrinogen- and fibronectin-binding domains, we tested the role of these functionalities by deleting the fibrinogen-binding domain of FnBPA and supplementing it with the fibrinogen-binding domain of ClfA in cis or in trans. Deletion of the fibrinogen-binding domain of FnBPA did not alter fibronectin binding and cell internalization in vitro. However, it totally abrogated valve infectivity in vivo. This ability was restored in cis by inserting the fibrinogen-binding domain of ClfA into truncated FnBPA, and in trans by coexpressing full-length ClfA and truncated FnBPA on two separate plasmids. Thus, fibrinogen and fibronectin binding could cooperate for S. aureus valve colonization and endothelial invasion in vivo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The stable carbon and oxygen isotope compositions of fossil ostracods are powerful tools to estimate past environmental and climatic conditions. The basis for such interpretations is that the calcite of the valves reflects the isotopic composition of water and its temperature of formation. However, calcite of ostracods is known not to form in isotopic equilibrium with water and different species may have different offsets from inorganic precipitates of calcite formed under the same conditions. To estimate the fractionation during ostracod valve calcification, the oxygen and carbon isotope compositions of 15 species living in Lake Geneva were related to their autoecology and the environmental parameters measured during their growth. The results indicate that: (1) Oxygen isotope fractionation is similar for all species of Candoninae with an enrichment in 18O of more than 30/00 relative to equilibrium values for inorganic calcite. Oxygen isotope fractionation for Cytheroidea is less discriminative relative to the heavy oxygen, with enrichments in 18O for these species of 1.7 to 2.30/00. Oxygen isotope fractionations for Cyprididae are in-between those of Candoninae and Cytheroidea. The difference in oxygen isotope fractionation between ostracods and inorganic calcite has been interpreted as resulting from a vital effect. (2) Comparison with previous work suggests that oxygen isotope fractionation may depend on the total and relative ion content of water. (3) Carbon isotope compositions of ostracod valves are generally in equilibrium with DIC. The specimens' δ13C values are mainly controlled by seasonal variations in δ13CDIC of bottom water or variation thereof in sediment pore water. (4) Incomplete valve calcification has an effect on carbon and oxygen isotope compositions of ostracod valves. Preferential incorporation of at the beginning of valve calcification may explain this effect. (5) Results presented here as well as results from synthetic carbonate growth indicate that different growth rates or low pH within the calcification site cannot be the cause of oxygen isotope 'vital effects' in ostracods. Two mechanisms that might enrich the 18O of ostracod valves are deprotonation of that may also contribute to valve calcification, and effects comparable to salt effects with high concentrations of Ca and/or Mg within the calcification site that may also cause a higher temperature dependency of oxygen isotope fractionation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transient high-grade bacteremia following invasive procedures carries a risk of infective endocarditis (IE). This is supported by experimental endocarditis. On the other hand, case-control studies showed that IE could be caused by cumulative exposure to low-grade bacteremia occurring during daily activities. However, no experimental demonstration of this latter possibility exists. This study investigated the infectivity in animals of continuous low-grade bacteremia compared to that of brief high-grade bacteremia. Rats with aortic vegetations were inoculated with Streptococcus intermedius, Streptococcus gordonii or Staphylococcus aureus (strains Newman and P8). Animals were challenged with 10(3) to 10(6) CFU. Identical bacterial numbers were given by bolus (1 ml in 1 min) or continuous infusion (0.0017 ml/min over 10 h). Bacteremia was 50 to 1,000 times greater after bolus than during continuous inoculation. Streptococcal bolus inoculation of 10(5) CFU infected 63 to 100% vegetations compared to 30 to 71% infection after continuous infusion (P > 0.05). When increasing the inoculum to 10(6) CFU, bolus inoculation infected 100% vegetations and continuous infusion 70 to 100% (P > 0.05). S. aureus bolus injection of 10(3) CFU infected 46 to 57% valves. This was similar to the 53 to 57% infection rates produced by continuous infusion (P > 0.05). Inoculation of 10(4) CFU of S. aureus infected 80 to 100% vegetations after bolus and 60 to 75% after continuous infusion (P > 0.05). These results show that high-level bacteremia is not required to induce experimental endocarditis and support the hypothesis that cumulative exposure to low-grade bacteremia represents a genuine risk of IE in humans.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The directional flow of lymph is maintained by hundreds of intraluminal lymphatic valves. Lymphatic valves are crucial to prevent lymphedema, accumulation of fluid in the tissues, and to ensure immune surveillance; yet, the mechanisms of valve formation are only beginning to be elucidated. In this chapter, we will discuss the main steps of lymphatic valve morphogenesis, the important role of mechanotransduction in this process, and the genetic program regulated by the transcription factor Foxc2, which is indispensable for all steps of valve development. Failure to form mature collecting lymphatic vessels and valves causes the majority of postsurgical lymphedema, e.g., in breast cancer patients. Therefore, this knowledge will be useful for diagnostics and development of better treatments of secondary lymphedema.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reviews: 1) some of the results of drug eluting stents (SYNTAX and FAME); 2) the questionnable benefit of physical training in heart failure patients (HF-ACTION); 3) the benefit on cardiac remodelling of cardiac resynchronisation in heart failure patients (REVERSE study) and 4) the role of rate over rhythm control in patients with atrial fibrillation and heart failure (AF-CHF study); this article also reports the encouraging evolution of new technology allowing percutaneous implantation of stents-valves. Finally, this article address the screening of athletes for cardiac diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Infective endocarditis (IE) mostly occurs after spontaneous low-grade bacteremia. Thus, IE cannot be prevented by circumstantial antibiotic prophylaxis. Platelet activation following bacterial-fibrinogen interaction or thrombin-mediated fibrinogen-fibrin polymerization is a critical step in vegetation formation. We tested the efficacy of antiplatelet and antithrombin to prevent experimental IE. METHODS: A rat model of experimental IE following prolonged low-grade bacteremia mimicking smoldering bacteremia in humans was used. Prophylaxis with antiplatelets (aspirin, ticlopidine [alone or in combination], eptifibatide, or abciximab) or anticoagulants (antithrombin dabigatran etexilate or anti-vitamin K acenocoumarol) was started 2 days before inoculation with Streptococcus gordonii or Staphylococcus aureus. Valve infection was assessed 24 hours later. RESULTS: Aspirin plus ticlopidine, as well as abciximab, protected 45%-88% of animals against S. gordonii and S. aureus IE (P < .05). Dabigatran etexilate protected 75% of rats against IE due to S. aureus (P < .005) but failed to protect against S. gordonii (<30% protection). Acenocoumarol was ineffective. CONCLUSIONS: Antiplatelet and direct antithrombin agents may be useful in the prophylaxis of IE in humans. In particular, the potential dual benefit of dabigatran etexilate might be reconsidered for patients with prosthetic valves, who require life-long anticoagulation and in whom S. aureus IE is associated with high mortality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The transapical transcatheter aortic valve implantation (TA-TAVI) in degenerated aortic bioprosthesis is an emerging therapy for surgically non-amenable patients. However, the presence of different types of aortic bioprostheses (stented and stentless), available in different sizes (19-27 mm), can be at the origin of important mismatches between the malfunctioning, degenerated aortic valves and the inner stent-valves implanted through transapical accesses (23 and 26 mm Edwards Sapien transcatheter stent-valves). We report an emergency TA-TAVI treatment of a severely regurgitant degenerated 23 mm Mitroflow aortic bioprosthesis (Sorin Group, Milano, Italy) implanted seven years earlier in an 80-year-old lady, and we reviewed the current available literature about transapical 'valve-in-valve' procedures to analyze the hemodynamic results and the ideal 'prosthesis-to-prosthesis' match.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The combination of fluconazole (FLC) and cyclosporine (CY) is fungicidal in FLC-susceptible C. albicans (O. Marchetti, P. Moreillon, M. P. Glauser, J. Bille, and D. Sanglard, Antimicrob. Agents Chemother. 44:2373-2381, 2000). The mechanism of this synergism is unknown. CY has several cellular targets including multidrug efflux transporters. The hypothesis that CY might inhibit FLC efflux was investigated by comparing the effect of FLC-CY in FLC-susceptible parent CAF2-1 (FLC MIC, 0.25 mg/liter) and in FLC-hypersusceptible mutant DSY1024 (FLC MIC, 0.03 mg/liter), in which the CDR1, CDR2, CaMDR1, and FLU1 transporter genes have been selectively deleted. We postulated that a loss of the fungicidal effect of FLC-CY in DSY1024 would confirm the roles of these efflux pumps. Time-kill curve studies showed a more potent fungistatic effect of FLC (P = 0.05 at 48 h with an inoculum of 10(3) CFU/ml) and a more rapid fungicidal effect of FLC-CY (P = 0.05 at 24 h with an inoculum of 10(3) CFU/ml) in the FLC-hypersusceptible mutant compared to those in the parent. Rats with experimental endocarditis were treated for 2 or 5 days with high-dose FLC, high-dose CY, or both drugs combined. FLC monotherapy for 5 days was more effective against the hypersusceptible mutant than against the parent. However, the addition of CY to FLC still conferred a therapeutic advantage in animals infected with mutant DSY1024, as indicated by better survival (P = 0.04 versus the results obtained with FLC) and sterilization of valves and kidneys after a very short (2-day) treatment (P = 0.009 and 0.002, respectively, versus the results obtained with FLC). Both in vitro and in vivo experiments consistently showed that the deletion of the four membrane transporters in DSY1024 did not result in loss of the fungicidal effect of FLC-CY. Yet, the accelerated killing in the mutant suggested a "dual-hit" mechanism involving FLC hypersusceptibility due to the efflux pump elimination and fungicidal activity conferred by CY. Thus, inhibition of multidrug efflux transporters encoded by CDR1, CDR2, CaMDR1, and FLU1 genes is not responsible for the fungicidal synergism of FLC-CY. Other cellular targets must be considered.