59 resultados para Technical contents
Resumo:
The Jebel Ressas Pb-Zn deposits in North-Eastern Tunisia occur mainly as open-space fillings (lodes, tectonic breccia cements) in bioclastic limestones of the Upper Jurassic Ressas Formation and along the contact of this formation with Triassic rocks. The galena-sphalerite association and their alteration products (cerussite, hemimorphite, hydrozincite) are set within a calcite gangue. The Triassic rocks exhibit enrichments in trace metals, namely Pb, Co and Cd enrichment in clays and Pb, Zn, Cd, Co and Cr enrichment in carbonates, suggesting that the Triassic rocks have interacted with the ore-bearing fluids associated with the Jebel Ressas Pb-Zn deposits. The delta(18)O content of calcite associated with the Pb-Zn mineralization suggests that it is likely to have precipitated from a fluid that was in equilibrium with the Triassic dolostones. The delta(34)S values in galenas from the Pb-Zn deposits range from -1.5 to +11.4%, with an average of 5.9% and standard deviation of 3.9%. These data imply mixing of thermochemically-reduced heavy sulfur carried in geothermal- and fault-stress-driven deep-seated source fluid with bacterially-reduced light sulfur carried in topography-driven meteoric fluid. Lead isotope ratios in galenas from the Pb-Zn deposits are homogenous and indicate a single upper crustal source of base-metals for these deposits. Synthesis of the geochemical data with geological data suggests that the base-metal mineralization at Jebel Ressas was formed during the Serravallian-Tortonian (or Middle-Late Miocene) Alpine compressional tectonics.
Resumo:
INTRODUCTION: Developments in technology, web-based teaching and whole slide imaging have broadened the teaching horizon in anatomic pathology. Creating online learning material including many types of media such as radiologic images, whole slides, videos, clinical and macroscopic photographs, is now accessible to most universities. Unfortunately, a major limiting factor to maintain and update the learning material is the amount of resources needed. In this perspective, a French-national university network was initiated in 2011 to build joint online teaching modules consisting of clinical cases and tests. The network has since expanded internationally to Québec, Switzerland and Ivory Coast. METHOD: One of the first steps of the project was to build a learning module on inflammatory skin pathology for interns and residents in pathology and dermatology. A pathology resident from Québec spent 6 weeks in France and Switzerland to develop the contents and build the module on an e-learning Moodle platform under the supervision of two dermatopathologists. The learning module contains text, interactive clinical cases, tests with feedback, virtual slides, images and clinical photographs. For that module, the virtual slides are decentralized in 2 universities (Bordeaux and Paris 7). Each university is responsible of its own slide scanning, image storage and online display with virtual slide viewers. RESULTS: The module on inflammatory skin pathology includes more than 50 web pages with French original content, tests and clinical cases, links to over 45 virtual images and more than 50 microscopic and clinical photographs. The whole learning module is being revised by four dermatopathologists and two senior pathologists. It will be accessible to interns and residents in the spring of 2014. The experience and knowledge gained from that work will be transferred to the next international resident whose work will be aimed at creating lung and breast pathology learning modules. CONCLUSION: The challenges of sustaining a project of this scope are numerous. The technical aspect of whole-slide imaging and storage needs to be developed by each university or group. The content needs to be regularly updated and its accuracy reviewed by experts in each individual domain. The learning modules also need to be promoted within the academic community to ensure maximal benefit for trainees. A collateral benefit of the project was the establishment of international partnerships between French-speaking universities and pathologists with the common goal of promoting pathology education through the use of multi-media technology including whole slide imaging.
Resumo:
The purpose of this study was to prospectively use a whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography technique specifically adapted for use at 3 T and a parallel imaging technique (sensitivity encoding) to evaluate coronary arterial anomalies and variants (CAAV). This HIPAA-compliant study was approved by the local institutional review board, and informed consent was obtained from all participants. Twenty-two participants (11 men, 11 women; age range, 18-62 years) were included. Ten participants were healthy volunteers, whereas 12 participants were patients suspected of having CAAV. Coronary MR angiography was performed with a 3-T MR imager. A 3D free-breathing navigator-gated and vector electrocardiographically-gated segmented k-space gradient-echo sequence with adiabatic T2 preparation pulse and parallel imaging (sensitivity encoding) was used. Whole-heart acquisitions (repetition time msec/echo time msec, 4/1.35; 20 degrees flip angle; 1 x 1 x 2-mm acquired voxel size) lasted 10-12 minutes. Mean examination time was 41 minutes +/- 14 (standard deviation). Findings included aneurysms, ectasia, arteriovenous fistulas, and anomalous origins. The 3D whole-heart acquisitions developed for use with 3 T are feasible for use in the assessment of CAAV.
Resumo:
Postmortem MRI (PMMR) examinations are seldom performed in legal medicine due to long examination times, unfamiliarity with the technique, and high costs. Furthermore, it is difficult to obtain access to an MRI device used for patients in clinical settings to image an entire human body. An alternative is available: ex situ organ examination. To our knowledge, there is no standardized protocol that includes ex situ organ preparation and scanning parameters for postmortem MRI. Thus, our objective was to develop a standard procedure for ex situ heart PMMR examinations. We also tested the oily contrast agent Angiofil® commonly used for PMCT angiography, for its applicability in MRI. We worked with a 3 Tesla MRI device and 32-channel head coils. Twelve porcine hearts were used to test different materials to find the best way to prepare and place organs in the device and to test scanning parameters. For coronary MR angiography, we tested different mixtures of Angiofil® and different injection materials. In a second step, 17 human hearts were examined to test the procedure and its applicability to human organs. We established two standardized protocols: one for preparation of the heart and another for scanning parameters based on experience in clinical practice. The established protocols enabled a standardized technical procedure with comparable radiological images, allowing for easy radiological reading. The performance of coronary MR angiography enabled detailed coronary assessment and revealed the utility of Angiofil® as a contrast agent for PMMR. Our simple, reproducible method for performing heart examinations ex situ yields high quality images and visualization of the coronary arteries.
Resumo:
In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been used successfully in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits; to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles.
Resumo:
In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been successfully used in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits, to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles.
Resumo:
Neurophysiology is an essential tool for clinicians dealing with patients in the intensive care unit. Because of consciousness disorders, clinical examination is frequently limited. In this setting, neurophysiological examination provides valuable information about seizure detection, treatment guidance, and neurological outcome. However, to acquire reliable signals, some technical precautions need to be known. EEG is prone to artifacts, and the intensive care unit environment is rich in artifact sources (electrical devices including mechanical ventilation, dialysis, and sedative medications, and frequent noise, etc.). This review will discuss and summarize the current technical guidelines for EEG acquisition and also some practical pitfalls specific for the intensive care unit.
Resumo:
This article examines how Samuelson defined his own role as an economist as a technical expert, who walked what he called the "middle of the road" to-seemingly-stay out of the realm of politics. As point of entry I discuss the highly tempting offers made by Theodore M. Schultz in the 1940s to come over to Chicago, which Schultz persistently repeated over three years and despite strong Chicago faculty resistance. A contrast between Schultz's own experiences as an economic expert at Iowa State, Samuelson's work as an external consultant for the National Resources Planning Board during the Second World War, and the firm support of the MIT administration for Samuelson's research serves to pinpoint the meaning of being technical for Samuelson, and the relation of the technical economic expert to the realm of politics.
Resumo:
Early warning systems (EWSs) rely on the capacity to forecast a dangerous event with a certain amount of advance by defining warning criteria on which the safety of the population will depend. Monitoring of landslides is facilitated by new technologies, decreasing prices and easier data processing. At the same time, predicting the onset of a rapid failure or the sudden transition from slow to rapid failure and subsequent collapse, and its consequences is challenging for scientists that must deal with uncertainties and have limited tools to do so. Furthermore, EWS and warning criteria are becoming more and more a subject of concern between technical experts, researchers, stakeholders and decision makers responsible for the activation, enforcement and approval of civil protection actions. EWSs imply also a sharing of responsibilities which is often averted by technical staff, managers of technical offices and governing institutions. We organized the First International Workshop on Warning Criteria for Active Slides (IWWCAS) to promote sharing and networking among members from specialized institutions and relevant experts of EWS. In this paper, we summarize the event to stimulate discussion and collaboration between organizations dealing with the complex task of managing hazard and risk related to active slides.