71 resultados para THERMOLUMINESCENCT DOSIMETRY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Efficacy and tumour selectivity of photodynamic therapy with two clinically approved sensitizers (mTHPC, verteporfin) were assessed for focal intracavitary photodynamic therapy (PDT) in rodents with malignant pleural mesothelioma (MPM) at recommended drug-light conditions and at escalating sensitizer dosages. MPM tumours were generated in 15 Fischer rats by subpleural mediastinal tumour cell injection followed after 5 days by intracavitary PDT with light delivery monitored by in situ dosimetry. Animals were intravenously sensitized either with mTHPC (0.1 mg/kg, n = 3; 0.2 mg/kg, n = 3) followed after 4 days by illumination with 20 J/cm(2) at 652 nm, or with verteporfin (0.6 mg/kg, n = 3; 1.2 mg/kg, n = 3) followed after 20 min by illumination with 100 J/cm(2) at 689 nm. Three untreated tumour-bearing animals served as controls. Histological evaluation of the treated tumour and of adjacent normal organs was performed 10 days after tumour implantation. The extent of PDT-induced tumour necrosis was compared to the non-necrosed area and expressed in percentage. A locally invasive growing MPM tumour (3.1 +/- 1 mm diameter) without spontaneous necrosis diameter was found in all animals. For both sensitizers, focal intracavitary PDT was well tolerated at drug-light conditions recommended for clinical applications. Mediastinal organs were spared for both sensitizers but verteporfin resulted in a higher extent of tumour necrosis (80%) than mTHPC (50%). Drug dose escalation revealed a higher extent of PDT-related tumour necrosis for both sensitizers (mTHPC 55%, verteporfin 88%), however, verteporfin-PDT was associated with a higher toxicity than mTHPC-PDT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was to evaluate the treatment dosimetry, efficacy and toxicity of intensity modulated radiation therapy (IMRT) and fractionated stereotactic radiotherapy (FSRT) in the management of infratentorial ependymoma. Between 1999 and 2007, seven children (median age, 3.1 years) with infratentorial ependymoma were planned with either IMRT (3 patients) or SFRT (4 patients), the latter after conventional posterior fossa irradiation. Two children underwent gross total resection. Median prescribed dose was 59.4 Gy (range, 55.8-60). The median follow-up for surviving patients was 4.8 years (range, 1.3-8). IMRT (median dose, 59.4 Gy) and FSRT (median dose, 55.8 Gy) achieved similar optimal target coverage. Percentages of maximum doses delivered to the cochleae (59.5 vs 85.0% Gy; P = 0.05) were significantly inferior with IMRT, when compared to FSRT planning. Percentages of maximum doses administered to the pituitary gland (38.2 vs 20.1%; P = 0.05) and optic chiasm (38.1 vs 14.1%; P = 0.001) were, however, significantly higher with IMRT, when compared to FSRT planning. No recurrences were observed at the last follow-up. The estimated 3-year progression-free survival and overall survival were 87.5 and 100%, respectively. No grade >1 acute toxicity was observed. Two patients presented late adverse events (grade 2 hypoacousia) during follow-up, without cognitive impairment. IMRT or FSRT for infratentorial ependymomas is effective and associated with a tolerable toxicity level. Both treatment techniques were able to capitalize their intrinsic conformal ability to deliver high-dose radiation. Larger series of patients treated with these two modalities will be necessary to more fully evaluate these delivery techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The number of fluoroscopy-guided procedures in cardiology is increasing over time and it is appropriate to wonder whether technological progress or change of techniques is influencing patient exposure. The aim of this study is to examine whether patient dose has been decreasing over the years. Patient dose data of more than 7700 procedures were collected from two cardiology centres. A steady increase in the patient dose over the years was observed in both the centres for the two cardiological procedures included in this study. Significant increase in dose was also observed after the installation of a flat-panel detector. The increasing use of radial access may lead to an increase in the patient exposure. The monitoring of dose data over time showed a considerable increase in the patient exposure over time. Actions have to be taken towards dose reduction in both the centres.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The optimization of the extremity dosimetry of medical staff in nuclear medicine was the aim of the Work Package 4 (WP4) of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Programme. Hand doses and dose distributions across the hands of medical staff working in nuclear medicine departments were evaluated through an extensive measurement program involving 32 hospitals in Europe and 139 monitored workers. The study included the most frequently used radionuclides, (99m)Tc- and (18)F-labelled radiopharmaceuticals for diagnostic and (90)Y-labelled Zevalin (R) and DOTATOC for therapy. Furthermore, Monte Carlo simulations were performed in different predefined scenarios to evaluate separately the efficacy of different radiation protection measures by comparing hand dose distributions according to various parameters. The present work gives recommendations based on results obtained with both measurements and simulations. This results in nine practical recommendations regarding the positioning of the dosemeters for an appropriate skin dose monitoring and the best protection means to reduce the personnel exposure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultraviolet (UV) radiation potentially damages the skin, the immune system, and structures of the eye. A useful UV sun protection for the skin has been established. Since a remarkable body of evidence shows an association between UV radiation and damage to structures of the eye, eye protection is important, but a reliable and practical tool to assess and compare the UV-protective properties of lenses has been lacking. Among the general lay public, misconceptions on eye-sun protection have been identified. For example, sun protection is mainly ascribed to sunglasses, but less so to clear lenses. Skin malignancies in the periorbital region are frequent, but usual topical skin protection does not include the lids. Recent research utilized exact dosimetry and demonstrated relevant differences in UV burden to the eye and skin at a given ambient irradiation. Chronic UV effects on the cornea and lens are cumulative, so effective UV protection of the eyes is important for all age groups and should be used systematically. Protection of children's eyes is especially important, because UV transmittance is higher at a very young age, allowing higher levels of UV radiation to reach the crystalline lens and even the retina. Sunglasses as well as clear lenses (plano and prescription) effectively reduce transmittance of UV radiation. However, an important share of the UV burden to the eye is explained by back reflection of radiation from lenses to the eye. UV radiation incident from an angle of 135°-150° behind a lens wearer is reflected from the back side of lenses. The usual antireflective coatings considerably increase reflection of UV radiation. To provide reliable labeling of the protective potential of lenses, an eye-sun protection factor (E-SPF®) has been developed. It integrates UV transmission as well as UV reflectance of lenses. The E-SPF® compares well with established skin-sun protection factors and provides clear messages to eye health care providers and to lay consumers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Objectives: Precursor lesions of oesophagus adenocarcinoma constitute a clinical dilemma. Photodynamic therapy (PDT) is an effective treatment for this indication, but it is difficult to optimise without an appropriate animal model. For this reason, we assessed the sheep model for PDT in the oesophagus with the photosensitiser meta-(tetra-hydroxyphenyl) chlorin (mTHPC). Materials and Methods: Twelve sheep underwent intravenous mTHPC injection, blood sampling and fluorescence measurements. mTHPC's pharmacokinetics was measured in vivo and in plasma by fluorescence spectroscopy. Biopsies of sheep oesophagus were compared to corresponding human tissue, and the mTHPC's biodistribution was studied under fluorescence microscopy. Finally, the sheep oesophageal mucosa was irradiated, 4 days after mTHPC's injection. Results: Histologically, the sheep and human oesophagus were closely comparable, with the exception of additional fatty tissue in the sheep oesophagus. mTHPC's pharmacokinetics in sheep and human plasmas were similar, with a maximum of concentration in the sheep 10 hours after i.v. injection. mTHPC's pharmacokinetics in vivo reached its maximum after 30-50 hours, then decreased to background levels, as in humans under similar conditions. Two days after injection, mTHPC was mainly distributed in the lamina propria, followed by a penetration into the epithelium. The sheep and human tissue sensitivity to mTHPC PDT was similar. Conclusion: In conclusion, this model showed many similarities with humans as to mTHPC's plasma and tissue pharmacokinetics, and for tissue PDT response, making it suitable to optimise oesophagus PDT. Lasers Surg. Med. 41:643-652,2009. (C) 2009Wiley-Liss,Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Whole-body counting is a technique of choice for assessing the intake of gamma-emitting radionuclides. An appropriate calibration is necessary, which is done either by experimental measurement or by Monte Carlo (MC) calculation. The aim of this work was to validate a MC model for calibrating whole-body counters (WBCs) by comparing the results of computations with measurements performed on an anthropomorphic phantom and to investigate the effect of a change in phantom's position on the WBC counting sensitivity. GEANT MC code was used for the calculations, and an IGOR phantom loaded with several types of radionuclides was used for the experimental measurements. The results show a reasonable agreement between measurements and MC computation. A 1-cm error in phantom positioning changes the activity estimation by >2%. Considering that a 5-cm deviation of the positioning of the phantom may occur in a realistic counting scenario, this implies that the uncertainty of the activity measured by a WBC is ∼10-20%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A magnetic resonance imaging (MRI) pulse sequence and a corresponding image processing algorithm to localize prostate brachytherapy seeds during or after therapy are presented. Inversion-Recovery with ON-resonant water suppression (IRON) is an MRI methodology that generates positive contrast in regions of magnetic field susceptibility, as created by prostate brachytherapy seeds. Phantoms comprising of several materials found in brachytherapy seeds were created to assess the usability of the IRON pulse sequence for imaging seeds. Resulting images show that seed materials are clearly visible with high contrast using IRON, agreeing with theoretical predictions. A seed localization algorithm to process IRON images demonstrates the potential of this imaging technique for seed localization and dosimetry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this work is to develop a method to objectively compare the performance of a digital and a screen-film mammography system in terms of image quality. The method takes into account the dynamic range of the image detector, the detection of high and low contrast structures, the visualisation of the images and the observer response. A test object, designed to represent a compressed breast, was constructed from various tissue equivalent materials ranging from purely adipose to purely glandular composition. Different areas within the test object permitted the evaluation of low and high contrast detection, spatial resolution and image noise. All the images (digital and conventional) were captured using a CCD camera to include the visualisation process in the image quality assessment. A mathematical model observer (non-prewhitening matched filter), that calculates the detectability of high and low contrast structures using spatial resolution, noise and contrast, was used to compare the two technologies. Our results show that for a given patient dose, the detection of high and low contrast structures is significantly better for the digital system than for the conventional screen-film system studied. The method of using a test object with a large tissue composition range combined with a camera to compare conventional and digital imaging modalities can be applied to other radiological imaging techniques. In particular it could be used to optimise the process of radiographic reading of soft copy images.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Radiosurgery (RS) is gaining increasing acceptance in the upfront management of brain metastases (BM). It was initially used in so-called radioresistant metastases (melanoma, renal cell, sarcoma) because it allowed delivering higher dose to the tumor. Now, RS is also used for BM of other cancers. The risk of high incidence of new BM questions the need for associated whole-brain radiotherapy (WBRT). Recent evidence suggests that RS alone allows avoiding cognitive impairment related to WBRT, and the latter should be upheld for salvage therapy. Thus the increase use of RS for single and multiple BM raises new technical challenges for treatment delivery and dosimetry. We present our single institution experience focusing on the criteria that led to patients' selection for RS treatment with Gamma Knife (GK) in lieu of Linac. METHODS: Leksell Gamma Knife Perfexion (Elekta, Sweden) was installed in July 2010. Currently, the Swiss federal health care supports the costs of RS for BM with Linac but not with GK. Therefore, in our center, we always consider first the possibility to use Linac for this indication, and only select patients for GK in specific situations. All cases of BM treated with GK were retrospectively reviewed for criteria yielding to GK indication, clinical information, and treatment data. Further work in progress includes a posteriori dosimetry comparison with our Linac planning system (Brainscan V.5.3, Brainlab, Germany). RESULTS: From July 2010 to March 2012, 20 patients had RS for BM with GK (7 patients with single BM, and 13 with multiple BM). During the same period, 31 had Linac-based RS. Primary tumor was melanoma in 9, lung in 7, renal in 2, and gastrointestinal tract in 2 patients. In single BM, the reason for choosing of GK was the anatomical location close to, or in highly functional areas (1 motor cortex, 1 thalamic, 1 ventricular, 1 mesio-temporal, 3 deep cerebellar close to the brainstem), especially since most of these tumors were intended to be treated with high-dose RS (24 Gy at margin) because of their histology (3 melanomas, 1 renal cell). In multiple BM, the reason for choosing GK in relation with the anatomical location of the lesions was either technical (limitations of Linac movements, especially in lower posterior fossa locations) or closeness of multiple lesions to highly functional areas (typically, multiple posterior fossa BM close to the brainstem), precluding optimal dosimetry with Linac. Again, this was made more critical for multiple BM needing high-dose RS (6 melanoma, 2 hypernephroma). CONCLUSION: Radiosurgery for BM may represent some technical challenge in relation with the anatomical location and multiplicity of the lesions. These considerations may be accentuated for so-called radioresistant BM, when higher dose RS in needed. In our experience, Leksell Gamma Knife Perfexion proves to be useful in addressing these challenges for the treatment of BM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Depth-dose curves in LiF detectors of different effective thicknesses, together with their responses, were calculated for typical nuclear medicine radiation fields with 99mTc, 18F and 90Y sources. Responses were analysed in function of the radionuclide, detector effective thickness and irradiation geometry. On the other hand the results of the nuclear medicine measurement campaign of the ORAMED project were presented focussing on the dose distribution across the hand and on the appropriate position to wear the dosimeter.According to the results, thin LiF detectors provide better responses in all cases. Its use is essential for 18F, since thick dosimeters can underestimate Hp(0.07) up to a 50% because of the very inhomogeneous dose deposition on the active layer. The preliminary results of the measurement campaign showed that the index tip of the non-dominant hand is usually the most exposed position among the 22 monitored positions. It was also found that, in average, wrist dosimeters are likely to underestimate the maximum skin dose by a factor of the order of 20. This factor is reduced to around 6 for a ring dosimeter worn on the base of the index of the non-dominant hand. Thus, for typical nuclear medicine procedures, the base of the index of the non-dominant hand is recommended as the best monitoring option.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A joint project between the Paul Scherrer Institut (PSI) and the Institute of Radiation Physics was initiated to characterise the PSI whole body counter in detail through measurements and Monte Carlo simulation. Accurate knowledge of the detector geometry is essential for reliable simulations of human body phantoms filled with known activity concentrations. Unfortunately, the technical drawings provided by the manufacturer are often not detailed enough and sometimes the specifications do not agree with the actual set-up. Therefore, the exact detector geometry and the position of the detector crystal inside the housing were determined through radiographic images. X-rays were used to analyse the structure of the detector, and (60)Co radiography was employed to measure the core of the germanium crystal. Moreover, the precise axial alignment of the detector within its housing was determined through a series of radiographic images with different incident angles. The hence obtained information enables us to optimise the Monte Carlo geometry model and to perform much more accurate and reliable simulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Experimental assessment of photodynamic therapy (PDT) for malignant pleural mesothelioma using a polyethylene glycol conjugate of meta-tetrahydroxyphenylchlorin (PEG-mTHPC). STUDY DESIGN/MATERIALS AND METHODS: (a) PDT was tested on H-meso-1 xenografts (652 nm laser light; fluence 10 J/cm(2); 0.93, 9.3, or 27.8 mg/kg of PEG-mTHPC; drug-light intervals 3-8 days). (b) Intraoperative PDT with similar treatment conditions was performed in the chest cavity of minipigs (n = 18) following extrapleural pneumonectomy (EPP) using an optical integrating balloon device combined with in situ light dosimetry. RESULTS: (a) PDT using PEG-mTHPC resulted in larger extent of tumor necrosis than in untreated tumors (P < or = 0.01) without causing damage to normal tissue. (b) Intraoperative PDT following EPP was well tolerated in 17 of 18 animals. Mean fluence and fluence rates measured at four sites of the chest cavity ranged from 10.2 +/- 0.2 to 13.2 +/- 2.3 J/cm(2) and 5.5 +/- 1.2 to 7.9 +/- 1.7 mW/cm(2) (mean +/- SD). Histology 3 months after light delivery revealed no PDT related tissue injury in all but one animal. CONCLUSIONS: PEG-mTHPC mediated PDT showed selective destruction of mesothelioma xenografts without causing damage to intrathoracic organs in pigs at similar treatment conditions. The light delivery system afforded regular light distribution to different parts of the chest cavity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Intensity-modulated radiotherapy (IMRT) credentialing for a EORTC study was performed using an anthropomorphic head phantom from the Radiological Physics Center (RPC; RPCPH). Institutions were retrospectively requested to irradiate their institutional phantom (INSTPH) using the same treatment plan in the framework of a Virtual Phantom Project (VPP) for IMRT credentialing. MATERIALS AND METHODS: CT data set of the institutional phantom and measured 2D dose matrices were requested from centers and sent to a dedicated secure EORTC uploader. Data from the RPCPH and INSTPH were thereafter centrally analyzed and inter-compared by the QA team using commercially available software (RIT; ver.5.2; Colorado Springs, USA). RESULTS: Eighteen institutions participated to the VPP. The measurements of 6 (33%) institutions could not be analyzed centrally. All other centers passed both the VPP and the RPC ±7%/4 mm credentialing criteria. At the 5%/5 mm gamma criteria (90% of pixels passing), 11(92%) as compared to 12 (100%) centers pass the credentialing process with RPCPH and INSTPH (p = 0.29), respectively. The corresponding pass rate for the 3%/3 mm gamma criteria (90% of pixels passing) was 2 (17%) and 9 (75%; p = 0.01), respectively. CONCLUSIONS: IMRT dosimetry gamma evaluations in a single plane for a H&N prospective trial using the INSTPH measurements showed agreement at the gamma index criteria of ±5%/5 mm (90% of pixels passing) for a small number of VPP measurements. Using more stringent, criteria, the RPCPH and INSTPH comparison showed disagreement. More data is warranted and urgently required within the framework of prospective studies.