167 resultados para Self monitoring blood glycose


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A headspace-gas chromatography-tandem mass spectrometry (HS-GC-MS/MS) method for the trace measurement of perfluorocarbon compounds (PFCs) in blood was developed. Due to oxygen carrying capabilities of PFCs, application to doping and sports misuse is speculated. This study was therefore extended to perform validation methods for F-tert-butylcyclohexane (Oxycyte(®)), perfluoro(methyldecalin) (PFMD) and perfluorodecalin (PFD). The limit of detection of these compounds was established and found to be 1.2µg/mL blood for F-tert-butylcyclohexane, 4.9µg/mL blood for PFMD and 9.6µg/mL blood for PFD. The limit of quantification was assumed to be 12µg/mL blood (F-tert-butylcyclohexane), 48µg/mL blood (PFMD) and 96µg/mL blood (PFD). HS-GC-MS/MS technique allows detection from 1000 to 10,000 times lower than the estimated required dose to ensure a biological effect for the investigated PFCs. Thus, this technique could be used to identify a PFC misuse several hours, maybe days, after the injection or the sporting event. Clinical trials with those compounds are still required to evaluate the validation parameters with the calculated estimations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For many drugs, finding the balance between efficacy and toxicity requires monitoring their concentrations in the patient's blood. Quantifying drug levels at the bedside or at home would have advantages in terms of therapeutic outcome and convenience, but current techniques require the setting of a diagnostic laboratory. We have developed semisynthetic bioluminescent sensors that permit precise measurements of drug concentrations in patient samples by spotting minimal volumes on paper and recording the signal using a simple point-and-shoot camera. Our sensors have a modular design consisting of a protein-based and a synthetic part and can be engineered to selectively recognize a wide range of drugs, including immunosuppressants, antiepileptics, anticancer agents and antiarrhythmics. This low-cost point-of-care method could make therapies safer, increase the convenience of doctors and patients and make therapeutic drug monitoring available in regions with poor infrastructure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The traditional basis for assessing the effect of antihypertensive therapy is the blood pressure reading taken by a physician. However, several recent trials have been designed to evaluate the blood pressure lowering effect of various therapeutic agents during the patients' normal daytime activities, using a portable, semi-automatic blood pressure recorder. The results have shown that in a given patient, blood pressure measured at the physician's office often differs greatly from that prevailing during the rest of the day. This is true both in treated and untreated hypertensive patients. The difference between office and ambulatory recorded pressures cannot be predicted from blood pressure levels measured by the physician. Therefore, a prospective study was carried out in patients with diastolic blood pressures that were uncontrolled at the physician's office despite antihypertensive therapy. The purpose was to evaluate the response of recorded ambulatory blood pressure to treatment adjustments aimed at reducing office blood pressure below a pre-set target level. Only patients with high ambulatory blood pressures at the outset appeared to benefit from further changes in therapy. Thus, ambulatory blood pressure monitoring can be used to identify those patients who remain hypertensive only when facing the physician, despite antihypertensive therapy. Ambulatory monitoring could thus help to evaluate the efficacy of antihypertensive therapy and allow individual treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Therapeutic drug monitoring (TDM) aims to optimize treatments by individualizing dosage regimens based on the measurement of blood concentrations. Dosage individualization to maintain concentrations within a target range requires pharmacokinetic and clinical capabilities. Bayesian calculations currently represent the gold standard TDM approach but require computation assistance. In recent decades computer programs have been developed to assist clinicians in this assignment. The aim of this survey was to assess and compare computer tools designed to support TDM clinical activities. The literature and the Internet were searched to identify software. All programs were tested on personal computers. Each program was scored against a standardized grid covering pharmacokinetic relevance, user friendliness, computing aspects, interfacing and storage. A weighting factor was applied to each criterion of the grid to account for its relative importance. To assess the robustness of the software, six representative clinical vignettes were processed through each of them. Altogether, 12 software tools were identified, tested and ranked, representing a comprehensive review of the available software. Numbers of drugs handled by the software vary widely (from two to 180), and eight programs offer users the possibility of adding new drug models based on population pharmacokinetic analyses. Bayesian computation to predict dosage adaptation from blood concentration (a posteriori adjustment) is performed by ten tools, while nine are also able to propose a priori dosage regimens, based only on individual patient covariates such as age, sex and bodyweight. Among those applying Bayesian calculation, MM-USC*PACK© uses the non-parametric approach. The top two programs emerging from this benchmark were MwPharm© and TCIWorks. Most other programs evaluated had good potential while being less sophisticated or less user friendly. Programs vary in complexity and might not fit all healthcare settings. Each software tool must therefore be regarded with respect to the individual needs of hospitals or clinicians. Programs should be easy and fast for routine activities, including for non-experienced users. Computer-assisted TDM is gaining growing interest and should further improve, especially in terms of information system interfacing, user friendliness, data storage capability and report generation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many studies based on either an experimental or an epidemiological approach, have shown that the ability to drive is impaired when the driver is under the influence of cannabis. Baseline performances of heavy users remain impaired even after several weeks of abstinence. Symptoms of cannabis abuse and dependence are generally considered incompatible with safe driving. Recently, it has been shown that traffic safety can be increased by reporting the long-term unfit drivers to the driver licensing authorities and referring the cases for further medical assessment. Evaluation of the frequency of cannabis use is a prerequisite for a reliable medical assessment of the fitness to drive. In a previous paper we advocated the use of two thresholds based on 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) concentration in whole blood to help to distinguish occasional cannabis users (≤3μg/L) from heavy regular smokers (≥40μg/L). These criteria were established on the basis of results obtained in a controlled cannabis smoking study with placebo, carried out with two groups of young male volunteers; the first group was characterized by a heavy use (≥10 joints/month) while the second group was made up of occasional users smoking at most 1 joint/week. However, to date, these cutoffs have not been adequately assessed under real conditions. Their validity can now be evaluated and confirmed with 146 traffic offenders' real cases in which the whole blood cannabinoid concentrations and the frequency of cannabis use are known. The two thresholds were not challenged by the presence of ethanol (40% of cases) and of other therapeutic and illegal drugs (24%). Thus, we propose the following procedure that can be very useful in the Swiss context but also in other countries with similar traffic policies: if the whole blood THCCOOH concentration is higher than 40μg/L, traffic offenders must be directed first and foremost toward medical assessment of their fitness to drive. This evaluation is not recommended if the THCCOOH concentration is lower than 3μg/L and if the self-rated frequency of cannabis use is less than 1 time/week. A THCCOOH level between these two thresholds cannot be reliably interpreted. In such a case, further medical assessment and follow-up of the fitness to drive are also suggested, but with lower priority.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE:: To examine the accuracy of brain multimodal monitoring-consisting of intracranial pressure, brain tissue PO2, and cerebral microdialysis-in detecting cerebral hypoperfusion in patients with severe traumatic brain injury. DESIGN:: Prospective single-center study. PATIENTS:: Patients with severe traumatic brain injury. SETTING:: Medico-surgical ICU, university hospital. INTERVENTION:: Intracranial pressure, brain tissue PO2, and cerebral microdialysis monitoring (right frontal lobe, apparently normal tissue) combined with cerebral blood flow measurements using perfusion CT. MEASUREMENTS AND MAIN RESULTS:: Cerebral blood flow was measured using perfusion CT in tissue area around intracranial monitoring (regional cerebral blood flow) and in bilateral supra-ventricular brain areas (global cerebral blood flow) and was matched to cerebral physiologic variables. The accuracy of intracranial monitoring to predict cerebral hypoperfusion (defined as an oligemic regional cerebral blood flow < 35 mL/100 g/min) was examined using area under the receiver-operating characteristic curves. Thirty perfusion CT scans (median, 27 hr [interquartile range, 20-45] after traumatic brain injury) were performed on 27 patients (age, 39 yr [24-54 yr]; Glasgow Coma Scale, 7 [6-8]; 24/27 [89%] with diffuse injury). Regional cerebral blood flow correlated significantly with global cerebral blood flow (Pearson r = 0.70, p < 0.01). Compared with normal regional cerebral blood flow (n = 16), low regional cerebral blood flow (n = 14) measurements had a higher proportion of samples with intracranial pressure more than 20 mm Hg (13% vs 30%), brain tissue PO2 less than 20 mm Hg (9% vs 20%), cerebral microdialysis glucose less than 1 mmol/L (22% vs 57%), and lactate/pyruvate ratio more than 40 (4% vs 14%; all p < 0.05). Compared with intracranial pressure monitoring alone (area under the receiver-operating characteristic curve, 0.74 [95% CI, 0.61-0.87]), monitoring intracranial pressure + brain tissue PO2 (area under the receiver-operating characteristic curve, 0.84 [0.74-0.93]) or intracranial pressure + brain tissue PO2+ cerebral microdialysis (area under the receiver-operating characteristic curve, 0.88 [0.79-0.96]) was significantly more accurate in predicting low regional cerebral blood flow (both p < 0.05). CONCLUSION:: Brain multimodal monitoring-including intracranial pressure, brain tissue PO2, and cerebral microdialysis-is more accurate than intracranial pressure monitoring alone in detecting cerebral hypoperfusion at the bedside in patients with severe traumatic brain injury and predominantly diffuse injury.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The correlation between noninvasive markers with endoscopic activity according to the modified Baron Index in patients with ulcerative colitis (UC) is unknown. We aimed to evaluate the correlation between endoscopic activity and fecal calprotectin (FC), C-reactive protein (CRP), hemoglobin, platelets, blood leukocytes, and the Lichtiger Index (clinical score). METHODS: UC patients undergoing complete colonoscopy were prospectively enrolled and scored clinically and endoscopically. Samples from feces and blood were analyzed in UC patients and controls. RESULTS: We enrolled 228 UC patients and 52 healthy controls. Endoscopic disease activity correlated best with FC (Spearman's rank correlation coefficient r = 0.821), followed by the Lichtiger Index (r = 0.682), CRP (r = 0.556), platelets (r = 0.488), blood leukocytes (r = 0.401), and hemoglobin (r = -0.388). FC was the only marker that could discriminate between different grades of endoscopic activity (grade 0, 16 [10-30] μg/g; grade 1, 35 [25-48] μg/g; grade 2, 102 [44-159] μg/g; grade 3, 235 [176-319] μg/g; grade 4, 611 [406-868] μg/g; P < 0.001 for discriminating the different grades). FC with a cutoff of 57 μg/g had a sensitivity of 91% and a specificity of 90% to detect endoscopically active disease (modified Baron Index ≥ 2). CONCLUSIONS: FC correlated better with endoscopic disease activity than clinical activity, CRP, platelets, hemoglobin, and blood leukocytes. The strong correlation with endoscopic disease activity suggests that FC represents a useful biomarker for noninvasive monitoring of disease activity in UC patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Elevated plasma cholesterol, high blood pressure and cigarette smoking are three major risk factors for coronary heart disease. Within the framework of Switzerland's participation in the multicenter study MONICA (MONItoring of trends and determinants in CArdiovascular disease), proposed by the WHO, a first risk factor survey was conducted in a representative sample of the population (25-74 years) of two reporting units (cantons of Vaud and Fribourg, canton of Tessin). A high blood cholesterol level (>6,7 mmol/l) is the most common risk factor for coronary heart disease among the studied population. Among men, about 13% have elevated blood pressure, the proportion being about one in ten among women; these proportions increase with age and are slightly above these values in Tessin. Cigarette smoking is still a common behavior; between 25 and 45 years one third of the population (male and female) regularly smoke cigarettes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Le don de sang représente un acte solidaire. Il est le plus souvent bénévole et, selon les pays et les circonstances, non rémunéré. Les éléments de la réflexion éthique sont, entre autres, l'augmentation des besoins, les critères d'exclusion de plus en plus nombreux, l'exigence sécuritaire et les modifications des structures de nos sociétés. Compte tenu de cela, les acteurs de la chaîne transfusionnelle doivent s'interroger sur certains paramètres : la valeur du don, le sens du bénévolat, l'opportunité de rémunérer l'acte de livrer une partie de soi, non plus comme un don et comme une expression d'altruisme et de solidarité, mais comme une prestation commerciale définie par des règles économiques. Blood donation is an act of solidarity. Most often, this act is done on a volunteer basis and, depending on countries and circumstances, is not remunerated. The increase in need, the always-greater number of deferral criteria, the safety issues and the changes in the structures of our societies are among the many subjects for ethical debates. Taking these into account, the actors of the transfusion must analyze certain parameters: the value of a donation, the meaning of volunteering, the appropriateness of remunerating the act of giving a part of one's self, no longer as a donation or an expression of altruism and solidarity, but as a commercial act regimented by economic laws.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The FIFA has implemented an important antidoping programme for the 2014 FIFA World Cup. AIM: To perform the analyses before and during the World Cup with biological monitoring of blood and urine samples. METHODS: All qualified players from the 32 teams participating in the World Cup were tested out-of-competition. During the World Cup, 2-8 players per match were tested. Over 1000 samples were collected in total and analysed in the WADA accredited Laboratory of Lausanne. RESULTS: The quality of the analyses was at the required level as described in the WADA technical documents. The urinary steroid profiles of the players were stable and consistent with previously published papers on football players. During the competition, amphetamine was detected in a sample collected on a player who had a therapeutic use exemption for attention deficit hyperactivity disorder. The blood passport data showed no significant difference in haemoglobin values between out-of-competition and postmatch samples. CONCLUSIONS: Logistical issues linked to biological samples collection, and the overseas shipment during the World Cup did not impair the quality of the analyses, especially when used as the biological passport of football players.