161 resultados para SIMPLE ASSAY
Resumo:
Isothermal microcalorimetry (IMC) has been used in the past to monitor metabolic activities in living systems. A few studies have used it on ecological research. In this study, IMC was used to monitor oxalotrophic activity, a widespread bacterial metabolism found in the environment, and particularly in soils. Six model strains were inoculated in solid angle media with K-oxalate as the sole carbon source. Cupriavidus oxalaticus, Cupriavidus necator, and Streptomyces violaceoruber presented the highest activity (91, 40, and 55 μW, respectively) and a maximum growth rate (μmax h(-1) ) of 0.264, 0.185, and 0.199, respectively, among the strains tested. These three strains were selected to test the incidence of different oxalate sources (Ca, Cu, and Fe-oxalate salts) in the metabolic activity. The highest activity was obtained in Ca-oxalate for C. oxalaticus. Similar experiments were carried out with a model soil to test whether this approach can be used to measure oxalotrophic activity in field samples. Although measuring oxalotrophic activity in a soil was challenging, there was a clear effect of the amendment with oxalate on the metabolic activity measured in soil. The correlation between heat flow and growth suggests that IMC analysis is a powerful method to monitor bacterial oxalotrophic activity
Resumo:
In Arabidopsis thaliana, gene expression level polymorphisms (ELPs) between natural accessions that exhibit simple, single locus inheritance are promising quantitative trait locus (QTL) candidates to explain phenotypic variability. It is assumed that such ELPs overwhelmingly represent regulatory element polymorphisms. However, comprehensive genome-wide analyses linking expression level, regulatory sequence and gene structure variation are missing, preventing definite verification of this assumption. Here, we analyzed ELPs observed between the Eil-0 and Lc-0 accessions. Compared with non-variable controls, 5' regulatory sequence variation in the corresponding genes is indeed increased. However, approximately 42% of all the ELP genes also carry major transcription unit deletions in one parent as revealed by genome tiling arrays, representing a >4-fold enrichment over controls. Within the subset of ELPs with simple inheritance, this proportion is even higher and deletions are generally more severe. Similar results were obtained from analyses of the Bay-0 and Sha accessions, using alternative technical approaches. Collectively, our results suggest that drastic structural changes are a major cause for ELPs with simple inheritance, corroborating experimentally observed indel preponderance in cloned Arabidopsis QTL.
Resumo:
Arsenic contamination of natural waters is a worldwide concern, as the drinking water supplies for large populations can have high concentrations of arsenic. Traditional techniques to detect arsenic in natural water samples can be costly and time-consuming; therefore, robust and inexpensive methods to detect arsenic in water are highly desirable. Additionally, methods for detecting arsenic in the field have been greatly sought after. This article focuses on the use of bacteria-based assays as an emerging method that is both robust and inexpensive for the detection of arsenic in groundwater both in the field and in the laboratory. The arsenic detection elements in bacteria-based bioassays are biosensor-reporter strains; genetically modified strains of, e.g., Escherichia coli, Bacillus subtilis, Staphylococcus aureus, and Rhodopseudomonas palustris. In response to the presence of arsenic, such bacteria produce a reporter protein, the amount or activity of which is measured in the bioassay. Some of these bacterial biosensor-reporters have been successfully utilized for comparative in-field analyses through the use of simple solution-based assays, but future methods may concentrate on miniaturization using fiberoptics or microfluidics platforms. Additionally, there are other potential emerging bioassays for the detection of arsenic in natural waters including nematodes and clams.
Resumo:
Successful expansion of haematopoietic cells in ex vivo cultures will have important applications in transplantation, gene therapy, immunotherapy and potentially also in the production of non-haematopoietic cell types. Haematopoietic stem cells (HSC), with their capacity to both self-renew and differentiate into all blood lineages, represent the ideal target for expansion protocols. However, human HSC are rare, poorly characterized phenotypically and genotypically, and difficult to test functionally. Defining optimal culture parameters for ex vivo expansion has been a major challenge. We devised a simple and reproducible stroma-free liquid culture system enabling long-term expansion of putative haematopoietic progenitors contained within frozen human fetal liver (FL) crude cell suspensions. Starting from a small number of total nucleated cells, a massive haematopoietic cell expansion, reaching > 1013-fold the input cell number after approximately 300 d of culture, was consistently achieved. Cells with a primitive phenotype were present throughout the culture and also underwent a continuous expansion. Moreover, the capacity for multilineage lymphomyeloid differentiation, as well as the recloning capacity of primitive myeloid progenitors, was maintained in culture. With its better proliferative potential as compared with adult sources, FL represents a promising alternative source of HSC and the culture system described here should be useful for clinical applications.
Resumo:
Voriconazole (VRC) is a broad-spectrum antifungal triazole with nonlinear pharmacokinetics. The utility of measurement of voriconazole blood levels for optimizing therapy is a matter of debate. Available high-performance liquid chromatography (HPLC) and bioassay methods are technically complex, time-consuming, or have a narrow analytical range. Objectives of the present study were to develop new, simple analytical methods and to assess variability of voriconazole blood levels in patients with invasive mycoses. Acetonitrile precipitation, reverse-phase separation, and UV detection were used for HPLC. A voriconazole-hypersusceptible Candida albicans mutant lacking multidrug efflux transporters (cdr1Delta/cdr1Delta, cdr2Delta/cdr2Delta, flu1Delta/flu1Delta, and mdr1Delta/mdr1Delta) and calcineurin subunit A (cnaDelta/cnaDelta) was used for bioassay. Mean intra-/interrun accuracies over the VRC concentration range from 0.25 to 16 mg/liter were 93.7% +/- 5.0%/96.5% +/- 2.4% (HPLC) and 94.9% +/- 6.1%/94.7% +/- 3.3% (bioassay). Mean intra-/interrun coefficients of variation were 5.2% +/- 1.5%/5.4% +/- 0.9% and 6.5% +/- 2.5%/4.0% +/- 1.6% for HPLC and bioassay, respectively. The coefficient of concordance between HPLC and bioassay was 0.96. Sequential measurements in 10 patients with invasive mycoses showed important inter- and intraindividual variations of estimated voriconazole area under the concentration-time curve (AUC): median, 43.9 mg x h/liter (range, 12.9 to 71.1) on the first and 27.4 mg x h/liter (range, 2.9 to 93.1) on the last day of therapy. During therapy, AUC decreased in five patients, increased in three, and remained unchanged in two. A toxic encephalopathy probably related to the increase of the VRC AUC (from 71.1 to 93.1 mg x h/liter) was observed. The VRC AUC decreased (from 12.9 to 2.9 mg x h/liter) in a patient with persistent signs of invasive aspergillosis. These preliminary observations suggest that voriconazole over- or underexposure resulting from variability of blood levels might have clinical implications. Simple HPLC and bioassay methods offer new tools for monitoring voriconazole therapy.
Comparison of Seegene Anyplex II HPV28 with the PGMY-CHUV Assay for Human Papillomavirus Genotyping.
Resumo:
The Anyplex II HPV28 (H28; Seegene) is a new semiquantitative real-time multiplex PCR assay for screening and genotyping 28 human papillomaviruses (HPV) in only 2 reaction wells. H28 was compared to the PGMY-CHUV assay (PG) with 309 archival DNA samples from cervical smears collected over 8 years in our laboratory. H28 and PG were fully concordant at the genotypic level on 228 (73.8%) out of 309 samples: 27 HPV negative and 201 HPV positive. The 201 fully concordant positive samples corresponded to single infections (n = 145) and to multiple infections (2 genotypes, n = 38; 3 to 5 genotypes, n = 18). The remaining 81 samples (26.2%) were either partially concordant (n = 64, 20.7%) or fully discordant (n = 17, 5.5%). While genotype-specific agreement was nearly perfect (κ = 0.877), HPV51 was significantly less well detected by H28 and the converse was observed for HPV40, -42, -54, and -68. Sequencing of PG amplicons confirmed HPV51 discordants and suggested the involvement of a possibly local HPV51 subtype. Mismatches in the PGMY09 primers to HPV68a explained most of the HPV68 discordants, confirming the specificity of H28 toward HPV68. With PG as a reference, the sensitivity and specificity of H28 were 93.4% and 99.0%, respectively. Considering H28 as a reference, the sensitivity and specificity of PG were 83.8% and 99.6%, respectively. H28 is a very sensitive and specific HPV genotyping assay suitable for research and clinical use as an adjunct to a clinically validated test. H28 semiquantitative readout ought to be evaluated for primary cervical cancer screening.
Resumo:
The performance of the Xpert MRSA polymerase chain reaction (PCR) assay on pooled nose, groin, and throat swabs (three nylon flocked eSwabs into one tube) was compared to culture by analyzing 5,546 samples. The sensitivity [0.78, 95 % confidence interval (CI) 0.73-0.82] and specificity (0.99, 95 % CI 0.98-0.99) were similar to the results from published studies on separated nose or other specimens. Thus, the performance of the Xpert MRSA assay was not affected by pooling the three specimens into one assay, allowing a higher detection rate without increasing laboratory costs, as compared to nose samples alone.
Resumo:
There is increasing evidence that the clinical efficacy of tamoxifen, the first and most widely used targeted therapy for estrogen-sensitive breast cancer, depends on the formation of the active metabolites 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen (endoxifen). Large inter-individual variability in endoxifen plasma concentrations has been observed and related both to genetic and environmental (i.e. drug-induced) factors altering CYP450s metabolizing enzymes activity. In this context, we have developed an ultra performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) requiring 100 μL of plasma for the quantification of tamoxifen and three of its major metabolites in breast cancer patients. Plasma is purified by a combination of protein precipitation, evaporation at room temperature under nitrogen, and reconstitution in methanol/20 mM ammonium formate 1:1 (v/v), adjusted to pH 2.9 with formic acid. Reverse-phase chromatographic separation of tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen is performed within 13 min using elution with a gradient of 10 mM ammonium formate and acetonitrile, both containing 0.1% formic acid. Analytes quantification, using matrix-matched calibration samples spiked with their respective deuterated internal standards, is performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection in the positive mode. The method was validated according to FDA recommendations, including assessment of relative matrix effects variability, as well as tamoxifen and metabolites short-term stability in plasma and whole blood. The method is precise (inter-day CV%: 2.5-7.8%), accurate (-1.4 to +5.8%) and sensitive (lower limits of quantification comprised between 0.4 and 2.0 ng/mL). Application of this method to patients' samples has made possible the identification of two further metabolites, 4'-hydroxy-tamoxifen and 4'-hydroxy-N-desmethyl-tamoxifen, described for the first time in breast cancer patients. This UPLC-MS/MS assay is currently applied for monitoring plasma levels of tamoxifen and its metabolites in breast cancer patients within the frame of a clinical trial aiming to assess the impact of dose increase on tamoxifen and endoxifen exposure.
Resumo:
Introduction: Oseltamivir phosphate (OP), the prodrug of oseltamivir carboxylate (OC; active metabolite), is marketed since 10 years for the treatment of seasonal influenza flu. It has recently received renewed attention because of the threat of avian flu H5N1 in 2006-7 and the 2009-10 A/H1N1 pandemic. However, relatively few studies have been published on OP and OC clinical pharmacokinetics. The disposition of OC and the dosage adaptation of OP in specific populations, such as young children or patients undergoing extrarenal epuration, have also received poor attention. An analytical method was thus developed to assess OP and OC plasma concentrations in patients receiving OP and presenting with comorbidities or requiring intensive care. Methods: A high performance liquid chromatography coupled to tandem mass spectrometry method (HPLC-MS/MS) requiring 100-µL aliquot of plasma for quantification within 6 min of OP and OC was developed. A combination of protein precipitation with acetonitrile, followed by dilution of supernant in suitable buffered solvent was used as an extraction procedure. After reverse phase chromatographic separation, quantification was performed by electro-spray ionization-triple quadrupole mass spectrometry. Deuterated isotopic compounds of OP and OC were used as internal standards. Results: The method is sensitive (lower limit of quantification: 5 ng/mL for OP and OC), accurate (intra-/inter-assay bias for OP and OC: 8.5%/5.5% and 3.7/0.7%, respectively) and precise (intra-/inter-assay CV%: 5.2%/6.5% and 6.3%/9.2%, respectively) over the clinically relevant concentration range (upper limits of quantification 5000 ng/mL). Of importance, OP, as in other previous reports, was found not to be stable ex vivo in plasma on standard anticoagulants (i.e. EDTA, heparin or citrate). This poor stability of OP has been prevented by collecting blood samples on commercial fluoride/oxalate tubes. Conclusions: This new simple, rapid and robust HPLC-MS/MS assay for quantification of OP and OC plasma concentrations offers an efficient tool for concentration monitoring of OC. Its exposure can probably be controlled with sufficient accuracy by thorough dosage adjustment according to patient characteristics (e.g. renal clearance). The usefulness of systematic therapeutic drug monitoring in patients appears therefore questionable. However, pharmacokinetic studies are still needed to extend knowledge to particular subgroups of patients or dosage regimens.
Resumo:
The pericentric inversion on chromosome 16 [inv(16)(p13q22)] and related t(16;16)(p13;q22) are recurrent aberrations associated with acute myeloid leukemia (AML) M4 Eo. Both abberations result in a fusion of the core binding factor beta (CBFB) and smooth muscle myosin heavy chain gene (MYH11). A selected genomic 6.9-kb BamHl probe detects MYH11 DNA rearrangements in 18 of 19 inv(16)/t(16;16) patients tested using HindIII digested DNA. The rearranged fragments were not detectable after remission in two cases tested, while they were present after relapse in one of these two cases tested.