191 resultados para Numerical Techniques


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to advances in neonatal intensive care over the last decades, the pattern of brain injury seen in very preterm infants has evolved in more subtle lesions that are still essential to diagnose in regard to neurodevelopmental outcome. While cranial ultrasound is still used at the bedside, magnetic resonance imaging (MRI) is becoming increasingly used in this population for the assessment of brain maturation and white and grey matter lesions. Therefore, MRI provides a better prognostic value for the neurodevelopmental outcome of these preterms. Furthermore, the development of new MRI techniques, such as diffusion tensor imaging, resting state functional connectivity and magnetic resonance spectroscopy, may further increase the prognostic value, helping to counsel parents and allocate early intervention services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the very large amount of data obtained everyday through population surveys, much of the new research again could use this information instead of collecting new samples. Unfortunately, relevant data are often disseminated into different files obtained through different sampling designs. Data fusion is a set of methods used to combine information from different sources into a single dataset. In this article, we are interested in a specific problem: the fusion of two data files, one of which being quite small. We propose a model-based procedure combining a logistic regression with an Expectation-Maximization algorithm. Results show that despite the lack of data, this procedure can perform better than standard matching procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the morphological determination of living individuals of the two sibling species S. araneus and S. coronatus is not possible, we have tested two biochemical methods to determine these shrews in ecological studies. After producing specific antibodies by rabbits, we performed an immunological test on 25 individuals. With this first method, a correct determination was achieved in 76% of the cases only. The second method proved very successful: a polyacrylamide gel electrophoresis showed a systematic difference for albumin (73 individuals analyzed). According to our experience, the necessary blood sampling (10-20 μl) seems harmless for the shrews

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chest physiotherapy (CP) using passive expiratory manoeuvres is widely used in Western Europe for the treatment of bronchiolitis, despite lacking evidence for its efficacy. We undertook an open randomised trial to evaluate the effectiveness of CP in infants hospitalised for bronchiolitis by comparing the time to clinical stability, the daily improvement of a severity score and the occurrence of complications between patients with and without CP. Children <1 year admitted for bronchiolitis in a tertiary hospital during two consecutive respiratory syncytial virus seasons were randomised to group 1 with CP (prolonged slow expiratory technique, slow accelerated expiratory flow, rarely induced cough) or group 2 without CP. All children received standard care (rhinopharyngeal suctioning, minimal handling, oxygen for saturation ≥92%, fractionated meals). Ninety-nine eligible children (mean age, 3.9 months), 50 in group 1 and 49 in group 2, with similar baseline variables and clinical severity at admission. Time to clinical stability, assessed as primary outcome, was similar for both groups (2.9 ± 2.1 vs. 3.2 ± 2.8 days, P = 0.45). The rate of improvement of a clinical and respiratory score, defined as secondary outcome, only showed a slightly faster improvement of the respiratory score in the intervention group when including stethoacoustic properties (P = 0.044). Complications were rare but occurred more frequently, although not significantly (P = 0.21), in the control arm. In conclusion, this study shows the absence of effectiveness of CP using passive expiratory techniques in infants hospitalised for bronchiolitis. It seems justified to recommend against the routine use of CP in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: We are interested in the numerical simulation of the anastomotic region comprised between outflow canula of LVAD and the aorta. Segmenta¬tion, geometry reconstruction and grid generation from patient-specific data remain an issue because of the variable quality of DICOM images, in particular CT-scan (e.g. metallic noise of the device, non-aortic contrast phase). We pro¬pose a general framework to overcome this problem and create suitable grids for numerical simulations.Methods: Preliminary treatment of images is performed by reducing the level window and enhancing the contrast of the greyscale image using contrast-limited adaptive histogram equalization. A gradient anisotropic diffusion filter is applied to reduce the noise. Then, watershed segmentation algorithms and mathematical morphology filters allow reconstructing the patient geometry. This is done using the InsightToolKit library (www.itk.org). Finally the Vascular Model¬ing ToolKit (www.vmtk.org) and gmsh (www.geuz.org/gmsh) are used to create the meshes for the fluid (blood) and structure (arterial wall, outflow canula) and to a priori identify the boundary layers. The method is tested on five different patients with left ventricular assistance and who underwent a CT-scan exam.Results: This method produced good results in four patients. The anastomosis area is recovered and the generated grids are suitable for numerical simulations. In one patient the method failed to produce a good segmentation because of the small dimension of the aortic arch with respect to the image resolution.Conclusions: The described framework allows the use of data that could not be otherwise segmented by standard automatic segmentation tools. In particular the computational grids that have been generated are suitable for simulations that take into account fluid-structure interactions. Finally the presented method features a good reproducibility and fast application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Echocardiography is the preferred initial test to assess cardiac morphology and ventricular function. Cardiac MRI enables an optimal visualisation of heart muscle without contrast injection, and precise measurement of the ventricular volumes and systolic function. It is therefore an ideal test for patients with poor echocardiographic windows or for the specific evaluation of right heart chambers. Heart CT also remarkably images heart muscle and precisely measures ventricular systolic function after intravenous injection of iodinated contrast. Coronary CT may also, in selected cases, avoid the need for diagnostic coronary angiography. Although very accurate, these imaging modalities are expensive and may be contra-indicated for a particular patient. Their use in clinical practice has to follow the accepted guidelines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Excessive exposure to solar Ultra-Violet (UV) light is the main cause of most skin cancers in humans. Factors such as the increase of solar irradiation at ground level (anthropic pollution), the rise in standard of living (vacation in sunny areas), and (mostly) the development of outdoor activities have contributed to increase exposure. Thus, unsurprisingly, incidence of skin cancers has increased over the last decades more than that of any other cancer. Melanoma is the most lethal cutaneous cancer, while cutaneous carcinomas are the most common cancer type worldwide. UV exposure depends on environmental as well as individual factors related to activity. The influence of individual factors on exposure among building workers was investigated in a previous study. Posture and orientation were found to account for at least 38% of the total variance of relative individual exposure. A high variance of short-term exposure was observed between different body locations, indicating the occurrence of intense, subacute exposures. It was also found that effective short-term exposure ranged between 0 and 200% of ambient irradiation, suggesting that ambient irradiation is a poor predictor of effective exposure. Various dosimetric techniques enable to assess individual effective exposure, but dosimetric measurements remain tedious and tend to be situation-specific. As a matter of facts, individual factors (exposure time, body posture and orientation in the sun) often limit the extrapolation of exposure results to similar activities conducted in other conditions. Objective: The research presented in this paper aims at developing and validating a predictive tool of effective individual exposure to solar UV. Methods: Existing computer graphic techniques (3D rendering) were adapted to reflect solar exposure conditions and calculate short-term anatomical doses. A numerical model, represented as a 3D triangular mesh, is used to represent the exposed body. The amount of solar energy received by each "triangle is calculated, taking into account irradiation intensity, incidence angle and possible shadowing from other body parts. The model take into account the three components of the solar irradiation (direct, diffuse and albedo) as well as the orientation and posture of the body. Field measurements were carried out using a forensic mannequin at the Payerne MeteoSwiss station. Short-term dosimetric measurements were performed in 7 anatomical locations for 5 body postures. Field results were compared to the model prediction obtained from the numerical model. Results: The best match between prediction and measurements was obtained for upper body parts such as shoulders (Ratio Modelled/Measured; Mean = 1.21, SD = 0.34) and neck (Mean = 0.81, SD = 0.32). Small curved body parts such as forehead (Mean = 6.48, SD = 9.61) exhibited a lower matching. The prediction is less accurate for complex postures such as kneeling (Mean = 4.13, SD = 8.38) compared to standing up (Mean = 0.85, SD = 0.48). The values obtained from the dosimeters and the ones computed from the model are globally consistent. Conclusion: Although further development and validation are required, these results suggest that effective exposure could be predicted for a given activity (work or leisure) in various ambient irradiation conditions. Using a generic modelling approach is of high interest in terms of implementation costs as well as predictive and retrospective capabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ECTIFS: Analyser les mouvements de patients entre cantons et selon les pathologies principales. Présentation du contexte, des enjeux et de l'interprétation des données. MÉTHODOLOGIE: Analyse, faite à partir de la base de données de la Statistique Hospitalière Suisse, de tous les transferts survenus entre 1998 et 2008 selon les variables suivantes : le sexe, l'âge, le canton d'hospitalisation, le canton de domicile du sujet et la pathologie. RÉSULTATS: Les transferts inter-cantonaux représentaient entre 2.7% (Genève) et 81.6% (Appenzell Rhodes intérieur) de la totalité des transferts entre hôpitaux. La majorité des transferts concerne les pathologies suivantes : cardiovasculaire (20.1%), ostéo-articulaire (9.3%), troubles mentaux (6.5%), oncologique (4.6%) et troubles respiratoires (2.6%). Les facteurs influençant la santé (28.7%) et les causes externes (12%) n'ont pas été inclus dans l'analyse. Le flux des transferts est orienté selon les tendances suivantes : attraction des cantons possédant un hôpital universitaire, l'accessibilité géographique (distances/obstacles), diversité des mouvements selon les pathologies et l'influence linguistique. L'attractivité des cantons est associée au nombre d'hôpitaux (r=0.82, p<0.001) ou de lits (r=0.85, p<0.001) qu'ils possèdent ainsi qu'à leur densité de lits (r=0.51, p<0.01), mais pas à leur densité hospitalière (r=0.08, p<0.7). CONCLUSION: Les cantons universitaires jouent leur rôle de pôle de compétences. Ce phénomène confirme que les transferts se font selon une logique de rationalisation des moyens techniques. Les mouvements de patients sont plus importants dans les cantons alémaniques. On constate une tendance moins forte parmi les cantons latins à " exporter " des patients. Les accords inter-cantonaux de transferts jouent un rôle dans le flux des patients en Suisse. [Auteur]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In European countries and North America, people spend 80 to 90% of time inside buildings and thus breathe indoor air. In Switzerland, special attention has been devoted to the 16 stations of the national network of observation of atmospheric pollutants (NABEL). The results indicate a reduction in outdoor pollution over the last ten years. With such a decrease in pollution over these ten years the question becomes: how can we explain an increase of diseases? Indoor pollution can be the cause. Indoor contaminants that may create indoor air quality (IAQ) problems come from a variety of sources. These can include inadequate ventilation, temperature and humidity dysfunction, and volatile organic compounds (VOCs). The health effects from these contaminants are varied and can range from discomfort, irritation and respiratory diseases to cancer. Among such contaminants, environmental tobacco smoke (ETS) could be considered the most important in terms of both health effects and engineering controls of ventilation. To perform indoor pollution monitoring, several selected ETS tracers can be used including carbon monoxide (CO), carbon dioxide (CO2), respirable particles (RSP), condensate, nicotine, polycyclic aromatic hydrocarbons (PAHs), nitrosamines, etc. In this paper, some examples are presented of IAQ problems that have occurred following the renewal of buildings and energy saving concerns. Using industrial hygiene sampling techniques and focussing on selected priority pollutants used as tracers, various problems have been identified and solutions proposed. [Author]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous ablative procedures allow curative treatment of stage BCLC 0 or BCLC A hepatocellular carcinoma, as well as liver metastases of colorectal cancer. Several methods exist including radiofrequency ablation, the most commonly used. These techniques can be used in combination with surgical excision or alone if surgery is contraindicated. They are associated with significantly reduced mortality as compared to surgery.