192 resultados para Nanoformulierungen, Liposomen, Nanoemulsionen, Kern-Schale Partikel, Orale Verabreichung


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Electroconvulsive therapy (ECT) may be used to treat severe depression and needs a specific general anaesthesia. Important cardiovascular changes occur during the ECT with a parasympathetic induced bradycardia followed by a sympathetic response. A dedicated protocol was designed 6 years ago. The goal of this study was to analyse the management of anaesthesia for ECT in our institution, the adherence to the protocol and the occurrence of adverse events during anaesthesia. Methods: After Institutional Ethics Committee approval, we conducted a retrospective analysis of our anaesthesia protocol for patients scheduled for electroshock therapy during a five years period (2004- 2008). The protocol includes administration of atropine subcutaneously 30 minutes before the procedure, followed by general anaesthesia induced with etomidate (0.2 mg/kg). Suxamethonium (1 mg/kg) is administered after the inflation of a pneumatic tourniquet on the opposite arm, in order to observe the electroshocks convulsive effects. The psychiatrist initiates the convulsive crisis once curarisation is achieved. Face mask ventilation is then applied during the post-ictal phase with closed blood pressure monitoring. : 228 ECT were performed in 25 patients. The median dosage of etomidate was 0.37 mg/kg and suxamethonium 1.20 mg/kg. Hypertension during the ECT procedure was present in 62.7% of cases, tachycardia 23.2% and bradycardia 10.5%. Esmolol was administered in 73.4% of hypertensive patients in a range of 0 to 30 mg. The protocol was followed in half of the cases in regards to atropine administration (50.4%). We observed a significant increase of hypertension (73.9%, p = 0.001) after atropine administration, without effect on heart rate. Conclusions: The management of anaesthesia for ECT is specific and follows a predefined protocol in our institution. Adherence to our protocol was poor. Adverse events are frequent and significant association between the administration of atropine and the incidence of hypertension as well as poor protocol adherence implies reconsideration of our anaesthesia protocol for electroconvulsive therapy and better quality control of the clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We use numerical simulations to investigate how the chain length and topology of freely fluctuating knotted polymer rings affect their various spatial characteristics such as the radius of the smallest sphere enclosing momentary configurations of simulated polymer chains. We describe how the average value of a characteristic changes with the chain size and how this change depends on the topology of the modeled polymers. Although the scaling profiles of a spatial characteristic for distinct knot types do not intersect (at least, in the range of our data), the profiles for nontrivial knots intersect the corresponding profile obtained for phantom polymers, i.e., those that are free to explore all available topological states. For each knot type, this point of intersection defines its equilibrium length with respect to the spatial characteristic. At this chain length, a polymer forming a given knot type will not tend to increase or decrease. on average, the value of the spatial characteristic when the polymer is released from its topological constraint. We show interrelations between equilibrium lengths defined with respect to spatial characteristics of different character and observe that they are related to the lengths of ideal geometric configurations of the corresponding knot types.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Cerebral cholinergic transmission plays a key role in cognitive function, and anticholinergic drugs administered during the perioperative phase are a hypothetical cause of postoperative cognitive dysfunction (POCD). We hypothesized that a perioperative increase in serum anticholinergic activity (SAA) is associated with POCD in elderly patients. METHODS: Seventy-nine patients aged >65 years undergoing elective major surgery under standardized general anesthesia (thiopental, sevoflurane, fentanyl, and atracurium) were investigated. Cognitive functions were assessed preoperatively and 7 days postoperatively using the extended version of the CERAD-Neuropsychological Assessment Battery. POCD was defined as a postoperative decline >1 z-score in at least 2 test variables. SAA was measured preoperatively and 7 days postoperatively at the time of cognitive testing. Hodges-Lehmann median differences and their 95% confidence intervals were calculated for between-group comparisons. RESULTS: Of the patients who completed the study, 46% developed POCD. Patients with POCD were slightly older and less educated than patients without POCD. There were no relevant differences between patients with and without POCD regarding gender, demographically corrected baseline cognitive functions, and duration of anesthesia. There were no large differences between patients with and without POCD regarding SAA preoperatively (pmol/mL, median [interquartile range]/median difference [95% CI], P; 1.14 [0.72, 2.37] vs 1.13 [0.68, 1.68]/0.12 [-0.31, 0.57], P = 0.56), SAA 7 days postoperatively (1.32 [0.68, 2.59] vs 0.97 [0.65, 1.83]/0.25 [-0.26, 0.81], P = 0.37), or changes in SAA (0.08 [-0.50, 0.70] vs -0.02 [-0.53, 0.41]/0.1 [-0.31, 0.52], P = 0.62). There was no significant relationship between changes in SAA and changes in cognitive function (Spearman rank correlation coefficient preoperatively of 0.03 [95% CI, -0.21, 0.26] and postoperatively of -0.002 [95% CI, -0.24, 0.23]). CONCLUSIONS: In this panel of patients with low baseline SAA and clinically insignificant perioperative anticholinergic burden, although a relationship cannot be excluded in some patients, our analysis suggests that POCD is probably not a substantial consequence of anticholinergic medications administered perioperatively but rather due to other mechanisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The last twenty years has witnessed important changes in the field of obstetric analgesia and anesthesia. In 2007, we conducted a survey to obtain information regarding the clinical practice of obstetric anesthesia in our country. The main objective was to ascertain whether recent developments in obstetric anesthesia had been adequately implemented into current clinical practice. Methodology: A confidential questionnaire was sent to 391 identified wiss obstetric anesthetists. The questionnaire included 58 questions on 5 main topics: activity and organization of the obstetric unit, practice of labor analgesia, practice of anesthesia for caesarean section, prevention of aspiration syndrome, and pain treatment after cesarean section. Results: The response rate was 80% (311/391). 66% of the surveyed anesthetists worked in intermediate size obstetric units (500-1500 deliveries per year). An anesthetist was on site 24/24 hours in only 53% of the obstetric units. Epidural labor analgesia with low dose local anesthetics combined with opioids was used by 87% but only 30% used patient controlled epidural analgesia (PCEA). Spinal anesthesia was the first choice for elective and urgent cesarean section for 95% of the responders. Adequate prevention of aspiration syndrome was prescribed by 78%. After cesarean section, a multimodal analgesic regimen was prescribed by 74%. Conclusion: When comparing these results with those of the two previous Swiss surveys [1, 2], it clearly appears that Swiss obstetric anesthetists have progressively adapted their practice to current clinical recommendations. But this survey also revealed some insufficiencies: 1. Of the public health system: a. Insufficient number of obstetric anesthetists on site 24 hours/24. b. Lack of budget in some hospitals to purchase PCEA pumps. 2. Of individual medical practice: a. Frequent excessive dosage of hyperbaric bupivacaine during spinal anesthesia for cesarean section. b. Frequent use of cristalloid preload before spinal anesthesia for cesarean section. c. Frequent systematic use of opioids when inducing general anesthesia for cesarean section. d. Fentanyl as the first choice opioid during induction of general anesthesia for severe preeclampsia. In the future, wider and more systematic information campaigns by the mean of the Swiss Association of Obstetric Anesthesia (SAOA) should be able to correct these points.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Application of cervical collars may reduce cervical spine movements but render tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesised that despite the presence of a Philadelphia Patriot (R) cervical collar and with the patient's head taped to the trolley, tracheal intubation would be possible in 50 adult patients using the GlideScope (R) and its dedicated stylet. Laryngoscopy was attempted using a Macintosh laryngoscope with a size 4 blade, and the modified Cormack-Lehane grade was scored. Subsequently, laryngoscopy with the GlideScope was graded and followed by tracheal intubation. All patients' tracheas were successfully intubated with the GlideScope. The median (IQR) intubation time was 50 s (43-61 s). The modified Cormack-Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScope (p < 0.0001), reaching grade 2a in most patients. Tracheal intubation in patients wearing a semi-rigid collar and having their head taped to the trolley is possible with the help of the GlideScope.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nanopartikel sind sehr kleine Partikel, die gezielt so hergestellt sind, dass ihr Durchmesser kleiner als etwa 100 nm ist. Sie werden in der Industrie eingesetzt, weil Materialien mit solch kleinen Dimensionen oft neue Eigenschaften aufweisen, die sie vom Ursprungsmaterial unterscheidet. Das Potenzial für mögliche Gesundheits- und Umwelteffekte von Nanomaterialien wird zurzeit intensiv diskutiert, denn die möglichen Effekte der neuen Eigenschaften auf Umwelt und Gesundheit sind erst unvollständig geklärt. Für die Abklärung der Risiken ist es wichtig, Informationen über die möglichen Expositionen und mögliche Freisetzungen in die Umwelt zu haben. Bisher wurden aber Daten über eingesetzte Stoffmengen und Materialarten selten systematisch erhoben. Wir haben in der Schweiz eine repräsentative Studie durchgeführt, um den Einsatz von Nanopartikeln im gesamten Industriesektor abschätzen zu können. Diese Studie ist unseres Wissens weltweit die erste solche Studie. Sie verwendete die Definition von Nanopartikeln, welche Nanofasern und Agglomerate von Nanopartikeln mit einschließt. Geschätzte 1.300 Arbeiter in 600 Firmen sind direkt an einer Nanopartikelanwendung beteiligt und könnten somit exponiert werden. Dies sind etwa 0,6% der Firmen und etwa 0,08% der Arbeiter des Schweizer Produktionssektors. Um nun zu bestimmen, ob solche Arbeiter mit Nanopartikel in Kontakt kommen oder nicht, stehen verschiedene Messmethoden zur Verfügung. Die aktuelle Technik erlaubt eine quantitative Messung der Anzahl der Partikel in der Luft, deren Masse oder auch Oberfläche. Diese Messgrößen allein geben zwar Hinweise auf die Präsenz von Nanopartikeln, die möglichen Gesundheitseffekte einer Exposition sind aber erst unvollständig abgeklärt und erlauben keine abschließende Risikoanalyse für den Arbeitsplatz. Mehrere Aktionspläne für die Entwicklung eines sicheren und nachhaltigen Umgangs mit Nanomaterialien wurden in den letzten Jahren gestartet (EU, Schweiz). Internationale und nationale Organisationen entwickelten Guidelines und Empfehlungen für industrielle Anwendungen (Internationale Organisation für Normung - ISO, Schweizerische Unfallversicherungsanstalt - SUVA, Bundesanstalt für Arbeitsschutz und Arbeitsmedizin - BAuA, zusammen mit dem Verband der Chemischen Industrie - VCI). Diese generellen Informationen müssen nun in die Industrie transferiert und an die spezifischen Bedürfnisse der betroffenen Unternehmen angepasst werden. Die aufgezeigte, relativ geringe Verbreitung von Nanopartikelanwendungen in der Industrie weist darauf hin, dass heute Schutzmaßnahmen noch proaktiv und kostengünstig entwickelt und eingeführt werden können. Aber sollte die vorhergesagte "Nano-Revolution" wirklich eintreten, ist die Zeit gekommen, jetzt aktiv zu werden. [Autoren]