207 resultados para Massé, Victor, 1822-1884.
Resumo:
Diabetes develops when the insulin needs of peripheral cells exceed the availability or action of the hormone. This situation results from the death of most beta-cells in type 1 diabetes, and from an inability of the beta-cell mass to adapt to increasing insulin needs in type 2 and gestational diabetes. We analyzed several lines of transgenic mice and showed that connexins (Cxs), the transmembrane proteins that form gap junctions, are implicated in the modulation of the beta-cell mass. Specifically, we found that the native Cx36 does not alter islet size or insulin content, whereas the Cx43 isoform increases both parameters, and Cx32 has a similar effect only when combined with GH. These findings open interesting perspectives for the in vitro and in vivo regulation of the beta-cell mass.
Resumo:
Obese persons (those with a body mass index [BMI] ≥30 kg/m2) tend to underestimate their weight, leading to an underestimation of their true (measured) BMI and obesity prevalence.1,2 In contrast, underweight people (BMI <18.5 kg/m2) tend to report themselves heavier, resulting in a higher BMI compared with measured BMI and an underestimation of underweight prevalence.
Resumo:
The treatment of some cancer patients has shifted from traditional, non-specific cytotoxic chemotherapy to chronic treatment with molecular targeted therapies. Imatinib mesylate, a selective inhibitor of tyrosine kinases (TKIs) is the most prominent example of this new era and has opened the way to the development of several additional TKIs, including sunitinib, nilotinib, dasatinib, sorafenib and lapatinib, in the treatment of various hematological malignancies and solid tumors. All these agents are characterized by an important inter-individual pharmacokinetic variability, are at risk for drug interactions, and are not devoid of toxicity. Additionally, they are administered for prolonged periods, anticipating the careful monitoring of their plasma exposure via Therapeutic Drug Monitoring (TDM) to be an important component of patients' follow-up. We have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 100 microL of plasma for the simultaneous determination of the six major TKIs currently in use. Plasma is purified by protein precipitation and the supernatant is diluted in ammonium formate 20 mM (pH 4.0) 1:2. Reverse-phase chromatographic separation of TKIs is obtained using a gradient elution of 20 mM ammonium formate pH 2.2 and acetonitrile containing 1% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 20 min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<9.6%), overall process efficiency (87.1-104.2%), as well as TKIs short- and long-term stability in plasma. The method is precise (inter-day CV%: 1.3-9.4%), accurate (-9.2 to +9.9%) and sensitive (lower limits of quantification comprised between 1 and 10 ng/mL). This is the first broad-range LC-MS/MS assay covering the major currently in-use TKIs. It is an improvement over previous methods in terms of convenience (a single extraction procedure for six major TKIs, reducing significantly the analytical time), sensitivity, selectivity and throughput. It may contribute to filling the current knowledge gaps in the pharmacokinetics/pharmacodynamics relationships of the latest TKIs developed after imatinib and better define their therapeutic ranges in different patient populations in order to evaluate whether a systematic TDM-guided dose adjustment of these anticancer drugs could contribute to minimize the risk of major adverse reactions and to increase the probability of efficient, long lasting, therapeutic response.
Resumo:
Since GHB (gamma-hydroxybutyric acid) is naturally produced in the human body, clinical and forensic toxicologists must be able to discriminate between endogenous levels and a concentration resulting from exposure. To suggest an alternative to the use of interpretative concentration cut-offs, the detection of exogenous GHB in urine specimens was investigated by means of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). GHB was isolated from urinary matrix by successive purification on Oasis MCX and Bond Elute SAX solid-phase extraction (SPE) cartridges prior to high-performance liquid chromatography (HPLC) fractioning using an Atlantis dC18 column eluted with a mixture of formic acid and methanol. Subsequent intramolecular esterification of GHB leading to the formation of gamma-butyrolactone (GBL) was carried out to avoid introduction of additional carbon atoms for carbon isotopic ratio analysis. A precision of 0.3 per thousand was determined using this IRMS method for samples at GHB concentrations of 10 mg/L. The (13)C/(12)C ratios of GHB in samples of subjects exposed to the drug ranged from -32.1 to -42.1 per thousand, whereas the results obtained for samples containing GHB of endogenous origin at concentration levels less than 10 mg/L were in the range -23.5 to -27.0 per thousand. Therefore, these preliminary results show that a possible discrimination between endogenous and exogenous GHB can be made using carbon isotopic ratio analyses.
Resumo:
The increasing number of bomb attacks involving improvised explosive devices, as well as the nature of the explosives, give rise to concern among safety and law enforcement agencies. The substances used in explosive charges are often everyday products diverted from their primary licit applications. Thus, reducing or limiting their accessibility for prevention purposes is difficult. Ammonium nitrate, employed in agriculture as a fertiliser, is used worldwide in small and large homemade bombs. Black powder, dedicated to hunting and shooting sports, is used illegally as a filling in pipe bombs causing extensive damage. If the main developments of instrumental techniques in explosive analysis have been constantly pushing the limits of detection, their actual contribution to the investigation of explosives in terms of source discrimination is limited. Forensic science has seen the emergence of a new technology, isotope ratio mass spectrometry (IRMS), that shows promising results. Its very first application in forensic science dates back to 1979. Liu et al. analysed cannabis plants coming from different countries [Liu et al. 1979]. This preliminary study highlighted its potential to discriminate specimens coming from different sources. Thirty years later, the keen interest in this new technology has given rise to a flourishing number of publications in forensic science. The countless applications of IRMS to a wide range of materials and substances attest to its success and suggest that the technique is ready to be used in forensic science. However, many studies are characterised by a lack of methodology and fundamental data. They have been undertaken in a top-down approach, applying this technique in an exploratory manner on a restricted sampling. This manner of procedure often does not allow the researcher to answer a number of questions, such as: do the specimens come from the same source, what do we mean by source or what is the inherent variability of a substance? The production of positive results has prevailed at the expense of forensic fundamentals. This research focused on the evaluation of the contribution of the information provided by isotopic analysis to the investigation of explosives. More specifically, this evaluation was based on a sampling of black powders and ammonium nitrate fertilisers coming from known sources. Not only has the methodology developed in this work enabled us to highlight crucial elements inherent to the methods themselves, but also to evaluate both the longitudinal and transversal variabilities of the information. First, the study of the variability of the profile over time was undertaken. Secondly, the variability of black powders and ammonium nitrate fertilisers within the same source and between different sources was evaluated. The contribution of this information to the investigation of explosives was then evaluated and discussed. --------------------------------------------------------------------------------------------------- Le nombre croissant d'attentats à la bombe impliquant des engins explosifs artisanaux, ainsi que la nature des charges explosives, constituent une préoccupation majeure pour les autorités d'application de la loi et les organismes de sécurité. Les substances utilisées dans les charges explosives sont souvent des produits du quotidien, détournés de leurs applications licites. Par conséquent, réduire ou limiter l'accessibilité de ces produits dans un but de prévention est difficile. Le nitrate d'ammonium, employé dans l'agriculture comme engrais, est utilisé dans des petits et grands engins explosifs artisanaux. La poudre noire, initialement dédiée à la chasse et au tir sportif, est fréquemment utilisée comme charge explosive dans les pipe bombs, qui causent des dommages importants. Si les développements des techniques d'analyse des explosifs n'ont cessé de repousser les limites de détection, leur contribution réelle à l'investigation des explosifs est limitée en termes de discrimination de sources. Une nouvelle technologie qui donne des résultats prometteurs a fait son apparition en science forensique: la spectrométrie de masse à rapport isotopique (IRMS). Sa première application en science forensique remonte à 1979. Liu et al. ont analysé des plants de cannabis provenant de différents pays [Liu et al. 1979]. Cette étude préliminaire, basée sur quelques analyses, a mis en évidence le potentiel de l'IRMS à discriminer des spécimens provenant de sources différentes. Trente ans plus tard, l'intérêt marqué pour cette nouvelle technologie en science forensique se traduit par un nombre florissant de publications. Les innombrables applications de l'IRMS à une large gamme de matériaux et de substances attestent de son succès et suggèrent que la technique est prête à être utilisée en science forensique. Cependant, de nombreuses études sont caractérisées par un manque de méthodologie et de données fondamentales. Elles ont été menées sans définir les hypothèses de recherche et en appliquant cette technique de façon exploratoire sur un échantillonnage restreint. Cette manière de procéder ne permet souvent pas au chercheur de répondre à un certain nombre de questions, tels que: est-ce que deux spécimens proviennent de la même source, qu'entend-on par source ou encore quelle est l'intravariabilité d'une substance? La production de résultats positifs a prévalu au détriment des fondamentaux de science forensique. Cette recherche s'est attachée à évaluer la contribution réelle de l'information isotopique dans les investigations en matière d'explosifs. Plus particulièrement, cette évaluation s'est basée sur un échantillonnage constitué de poudres noires et d'engrais à base de nitrate d'ammonium provenant de sources connues. La méthodologie développée dans ce travail a permis non seulement de mettre en évidence des éléments cruciaux relatifs à la méthode d'analyse elle-même, mais également d'évaluer la variabilité de l'information isotopique d'un point de vue longitudinal et transversal. Dans un premier temps, l'évolution du profil en fonction du temps a été étudiée. Dans un second temps, la variabilité du profil des poudres noires et des engrais à base de nitrate d'ammonium au sein d'une même source et entre différentes sources a été évaluée. La contribution de cette information dans le cadre des investigations d'explosifs a ensuite été discutée et évaluée.
Sex-specific selective pressures on body mass in the greater white-toothed shrew, Crocidura russula.
Resumo:
The direction, intensity and shape of viability-, sexual- and fecundity selection on body mass were investigated in a natural population of the greater white-toothed shrew (Crocidura russula), combining parentage assignment through molecular techniques and mark-recapture data over several generations. A highly significant stabilizing viability selection was found in both sexes, presumably stemming from the constraints imposed by their insectivorous habits and high metabolic costs. Sexual selection, directional in both sexes, was twice as large in males than in females. Our results suggest that body mass matters in this context by facilitating the acquisition and defense of a breeding territory. No fecundity selection could be detected. The direction of sexual size dimorphism (SSD) was in agreement with the observed pattern of selective pressures: males were heavier than females, because of stronger sexual selection. SSD intensity, however, was low compared with other mammals, because of the low level of polygyny, the active role of females in territory defense and the intensity of stabilizing viability selection.
Resumo:
BACKGROUND: There is concern that surgically-induced weight loss in obese subjects is associated with a disproportionate decrease in lean body mass (LBM) and in skeletal muscle mass (SMM), a major constituent of LBM. To address this issue, 1) we measured total and regional body composition following gastric banding in a group of obese subjects, and 2) we compared these data to those of a non-surgical control group of similar age and body size. METHODS: Body composition was assessed by dual-energy X-ray absorptiometry (DEXA) before and after laparoscopic adjustable silicone gastric banding (LAGB) in 32 women (after 1 year: age 43.7+/-8.4 years, BMI 36.4+/-5.9 kg/m2, mean+/-SD), and in 117 control women (age 44.5+/-7.5 years; BMI 36.7+/-5.5 kg/m2) referred for non-surgical weight management, prior to weight loss. SMM was estimated using a published equation based on LBM of the extremities (appendicular LBM). RESULTS: 1 year after LAGB, body weight loss (-23.7+/-11.6 kg, P<10(-6)) was mainly due to decreased fat mass (-21.2+/-11.2 kg, P<10(-6)), and total LBM was modestly, although significantly, decreased (-2.1+/-4.2 kg, P=0.01). Appendicular LBM (-0.7+/-2.7 kg) and total SMM (-0.9+/-3.0 kg) were not significantly modified. None of the body composition variables was significantly decreased in weight-reduced subjects compared to the control group, especially appendicular LBM and total SMM. CONCLUSIONS: Results provide no evidence for a decrease in appendicular LBM and total SMM with weight loss following LAGB. Follow-up of these obese patients revealed a very favorable pattern of change in total and regional body composition, with preservation of muscle mass.
Resumo:
For doping control, analyses of samples are generally achieved in two steps: a rapid screening and, in the case of a positive result, a confirmatory analysis. A two-step methodology based on ultra-high-pressure liquid chromatography coupled to a quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) was developed to screen and confirm 103 doping agents from various classes (e.g., beta-blockers, stimulants, diuretics, and narcotics). The screening method was presented in a previous article as part I (i.e., Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. Part I: screening analysis). For the confirmatory method, basic, neutral and acidic compounds were extracted by a dedicated solid-phase extraction (SPE) in a 96-well plate format and detected by MS in the tandem mode to obtain precursor and characteristic product ions. The mass accuracy and the elemental composition of precursor and product ions were used for compound identification. After validation including matrix effect determination, the method was considered reliable to confirm suspect results without ambiguity according to the positivity criteria established by the World Anti-Doping Agency (WADA). Moreover, an isocratic method was developed to separate ephedrine from its isomer pseudoephedrine and cathine from phenylpropanolamine in a single run, what allowed their direct quantification in urine.
Resumo:
New high-precision U/Pb geochronology from volcanic ashes shows that the Triassic-Jurassic boundary and end-Triassic biological crisis from two independent marine stratigraphic sections correlate with the onset of terrestrial flood volcanism in the Central Atlantic Magmatic Province to <150 ka. This narrows the correlation between volcanism and mass extinction by an order of magnitude for any such catastrophe in Earth history. We also show that a concomitant drop and rise in sea level and negative delta C-13 spike in the very latest Triassic occurred locally in <290 ka. Such rapid sea-level fluctuations on a global scale require that global cooling and glaciation were closely associated with the end-Triassic extinction and potentially driven by Central Atlantic Magmatic Province volcanism.
Resumo:
BACKGROUND: We sought to improve upon previously published statistical modeling strategies for binary classification of dyslipidemia for general population screening purposes based on the waist-to-hip circumference ratio and body mass index anthropometric measurements. METHODS: Study subjects were participants in WHO-MONICA population-based surveys conducted in two Swiss regions. Outcome variables were based on the total serum cholesterol to high density lipoprotein cholesterol ratio. The other potential predictor variables were gender, age, current cigarette smoking, and hypertension. The models investigated were: (i) linear regression; (ii) logistic classification; (iii) regression trees; (iv) classification trees (iii and iv are collectively known as "CART"). Binary classification performance of the region-specific models was externally validated by classifying the subjects from the other region. RESULTS: Waist-to-hip circumference ratio and body mass index remained modest predictors of dyslipidemia. Correct classification rates for all models were 60-80%, with marked gender differences. Gender-specific models provided only small gains in classification. The external validations provided assurance about the stability of the models. CONCLUSIONS: There were no striking differences between either the algebraic (i, ii) vs. non-algebraic (iii, iv), or the regression (i, iii) vs. classification (ii, iv) modeling approaches. Anticipated advantages of the CART vs. simple additive linear and logistic models were less than expected in this particular application with a relatively small set of predictor variables. CART models may be more useful when considering main effects and interactions between larger sets of predictor variables.
Resumo:
Laser desorption ionisation mass spectrometry (LDI-MS) has demonstrated to be an excellent analytical method for the forensic analysis of inks on a questioned document. The ink can be analysed directly on its substrate (paper) and hence offers a fast method of analysis as sample preparation is kept to a minimum and more importantly, damage to the document is minimised. LDI-MS has also previously been reported to provide a high power of discrimination in the statistical comparison of ink samples and has the potential to be introduced as part of routine ink analysis. This paper looks into the methodology further and evaluates statistically the reproducibility and the influence of paper on black gel pen ink LDI-MS spectra; by comparing spectra of three different black gel pen inks on three different paper substrates. Although generally minimal, the influences of sample homogeneity and paper type were found to be sample dependent. This should be taken into account to avoid the risk of false differentiation of black gel pen ink samples. Other statistical approaches such as principal component analysis (PCA) proved to be a good alternative to correlation coefficients for the comparison of whole mass spectra.
Resumo:
A sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of nicotine, its metabolites cotinine and trans-3'-hydroxycotinine and varenicline in human plasma was developed and validated. Sample preparation was realized by solid phase extraction of the target compounds and of the internal standards (nicotine-d4, cotinine-d3, trans-3'-hydroxycotinine-d3 and CP-533,633, a structural analog of varenicline) from 0.5mL of plasma, using a mixed-mode cation exchange support. Chromatographic separations were performed on a hydrophilic interaction liquid chromatography column (HILIC BEH 2.1×100mm, 1.7μm). A gradient program was used, with a 10mM ammonium formate buffer pH 3/acetonitrile mobile phase at a flow of 0.4mL/min. The compounds were detected on a triple quadrupole mass spectrometer, operated with an electrospray interface in positive ionization mode and quantification was performed using multiple reaction monitoring. Matrix effects were quantitatively evaluated with success, with coefficients of variation inferior to 8%. The procedure was fully validated according to Food and Drug Administration guidelines and to Société Française des Sciences et Techniques Pharmaceutiques. The concentration range was 2-500ng/mL for nicotine, 1-1000ng/mL for cotinine, 2-1000ng/mL for trans-3'-hydroxycotinine and 1-500ng/mL for varenicline, according to levels usually measured in plasma. Trueness (86.2-113.6%), repeatability (1.9-12.3%) and intermediate precision (4.4-15.9%) were found to be satisfactory, as well as stability in plasma. The procedure was successfully used to quantify nicotine, its metabolites and varenicline in more than 400 plasma samples from participants in a clinical study on smoking cessation.
Resumo:
Capillary zone electrophoresis (CZE) with UV detection has been widely used for the determination of carbohydrate-deficient transferrin (CDT), an indirect marker of the chronic alcohol consumption (≥60-80g/day). A commercially available method (CEofix? CDT kit), containing a bilayer anionic coating, allows for the analysis of CDT with a high resolution between transferrin (Tf) glycoforms with reduced protein adsorption onto the capillary wall. Although widely used in routine analysis, this procedure presents some limitations in terms of selectivity and sensitivity which may be overcome with mass spectrometry (MS). However, the available method is not MS-compatible due to the non-volatile coating as well as the phosphate and borate buffers present in the background electrolyte (BGE). This study firstly consisted in developing MS-compatible separation conditions, i.e., coating and BGE compositions. Numerous cationic, neutral, and anionic coatings were evaluated in combination with BGEs covering a broad range of pH values. A bilayer coating composed of a cationic layer of 10% polybrene (m/v) and an anionic layer of 10% dextran sulfate (m/v) combined with a BGE composed of 20mM ammonium acetate at pH 8.5 provided the best results in terms of glycoforms' resolution, efficiency, adsorption reduction, migration times' repeatability, and coating stability. The method was then transferred to CZE-MS after investigations of the electrospray ionization (ESI) source, equipped with a sheath-flow interface, and the time-of-flight (TOF/MS) parameters. A successful MS detection of tetrasialo-Tf was obtained during infusion, while the experiments highlighted the challenges and issues encountered with intact glycoprotein analysis by CZE-ESI-MS.
Resumo:
Consumption of nicotine in the form of smokeless tobacco (snus, snuff, chewing tobacco) or nicotine-containing medication (gum, patch) may benefit sport practice. Indeed, use of snus seems to be a growing trend and investigating nicotine consumption amongst professional athletes is of major interest to sport authorities. Thus, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection and quantification of nicotine and its principal metabolites cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide in urine was developed. Sample preparation was performed by liquid-liquid extraction followed by hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS) operated in electrospray positive ionization (ESI) mode with selective reaction monitoring (SRM) data acquisition. The method was validated and calibration curves were linear over the selected concentration ranges of 10-10,000 ng/mL for nicotine, cotinine, trans-3-hydroxycotinine and 10-5000 ng/mL for nicotine-N'-oxide and cotinine-N-oxide, with calculated coefficients of determination (R(2)) greater than 0.95. The total extraction efficiency (%) was concentration dependent and ranged between 70.4 and 100.4%. The lower limit of quantification (LLOQ) for all analytes was 10 ng/mL. Repeatability and intermediate precision were ?9.4 and ?9.9%, respectively. In order to measure the prevalence of nicotine exposure during the 2009 Ice Hockey World Championships, 72 samples were collected and analyzed after the minimum of 3 months storage period and complete removal of identification means as required by the 2009 International Standards for Laboratories (ISL). Nicotine and/or metabolites were detected in every urine sample, while concentration measurements indicated an exposure within the last 3 days for eight specimens out of ten. Concentrations of nicotine, cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide were found to range between 11 and 19,750, 13 and 10,475, 10 and 8217, 11 and 3396, and 13 and 1640 ng/mL, respectively. When proposing conservative concentration limits for nicotine consumption prior and/or during the games (50 ng/mL for nicotine, cotinine and trans-3-hydroxycotinine and 25 ng/mL for nicotine-N'-oxide and cotinine-N-oxide), about half of the hockey players were qualified as consumers. These findings significantly support the likelihood of extensive smokeless nicotine consumption. However, since such conclusions can only be hypothesized, the potential use of smokeless tobacco as a doping agent in ice hockey requires further investigation.