52 resultados para Lung volume measurement
Resumo:
Computer-Aided Tomography Angiography (CTA) images are the standard for assessing Peripheral artery disease (PAD). This paper presents a Computer Aided Detection (CAD) and Computer Aided Measurement (CAM) system for PAD. The CAD stage detects the arterial network using a 3D region growing method and a fast 3D morphology operation. The CAM stage aims to accurately measure the artery diameters from the detected vessel centerline, compensating for the partial volume effect using Expectation Maximization (EM) and a Markov Random field (MRF). The system has been evaluated on phantom data and also applied to fifteen (15) CTA datasets, where the detection accuracy of stenosis was 88% and the measurement accuracy was with an 8% error.
Resumo:
BACKGROUND: The impact of abnormal spirometric findings on risk for incident heart failure among older adults without clinically apparent lung disease is not well elucidated.METHODS: We evaluated the association of baseline lung function with incident heart failure, defined as first hospitalization for heart failure, in 2125 participants of the community-based Health, Aging, and Body Composition (Health ABC) Study (age, 73.6 +/- 2.9 years; 50.5% men; 62.3% white; 37.7% black) without prevalent lung disease or heart failure. Abnormal lung function was defined either as forced vital capacity (FVC) or forced expiratory volume in 1(st) second (FEV1) to FVC ratio below lower limit of normal. Percent predicted FVC and FEV1 also were assessed as continuous variables.RESULTS: During follow-up (median, 9.4 years), heart failure developed in 68 of 350 (19.4%) participants with abnormal baseline lung function, as compared with 172 of 1775 (9.7%) participants with normal lung function (hazard ratio [HR] 2.31; 95% confidence interval [CI], 1.74-3.07; P <.001). This increased risk persisted after adjusting for previously identified heart failure risk factors in the Health ABC Study, body mass index, incident coronary heart disease, and inflammatory markers (HR 1.83; 95% CI, 1.33-2.50; P <.001). Percent predicted (%) FVC and FEV 1 had a linear association with heart failure risk (HR 1.21; 95% CI, 1.11-1.32 and 1.18; 95% CI, 1.10-1.26, per 10% lower % FVC and % FEV1, respectively; both P <.001 in fully adjusted models). Findings were consistent in sex and race subgroups and for heart failure with preserved or reduced ejection fraction.CONCLUSIONS: Abnormal spirometric findings in older adults without clinical lung disease are associated with increased heart failure risk. (C) 2011 Elsevier Inc. All rights reserved. The American Journal of Medicine (2011) 124, 334-341
Resumo:
The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.
Resumo:
BACKGROUND: Liver remnant volumes after major hepatic resection and graft volumes for liver transplantation correlate with surgical outcome. The relative contributions of the hepatic segments to total liver volume (TLV) are not well established. METHODS: TLV and hepatic segment volumes were measured with computed tomography (CT) in 102 patients without liver disease who underwent CT for conditions unrelated to the liver or biliary tree. RESULTS: TLV ranged from 911 to 2729 cm(3). On average, the right liver (segments V, VI, VII, and VIII) contributed approximately two thirds of TLV (997+/-279 cm(3)), and the left liver (segments II, III and IV) contributed approximately one third of TLV (493+/-127 cm(3)). Bisegment II+III (left lateral section) contributed about half the volume of the left liver (242+/-79 cm(3)), or 16% of TLV. Liver volumes varied significantly between patients--the right liver varied from 49% to 82% of TLV, the left liver, 17% to 49% of TLV, and bisegment II+III (left lateral section) 5% to 27% of TLV. Bisegment II+III contributed less than 20% of TLV in more than 75% of patients and the left liver contributed 25% or less of TLV in more than 10% of patients. DISCUSSION: There is clinically significant interpatient variation in hepatic volumes. Therefore, in the absence of appreciable hypertrophy, we recommend routine measurement of the future liver remnant before extended right hepatectomy (right trisectionectomy) and in selected patients before right hepatectomy if a small left liver is anticipated.
Resumo:
OBJECTIVES: To determine whether valganciclovir 450 mg every 48 h for cytomegalovirus (CMV) prophylaxis provides appropriate ganciclovir exposure in solid organ transplant recipients during continuous renal replacement therapy (CRRT). PATIENTS AND METHODS: Ganciclovir pharmacokinetics was intensively studied in two lung transplant recipients under valganciclovir 450 mg every 48 h over one dosing interval. In vitro experiments using blank whole blood spiked with ganciclovir further investigated exchanges between plasma and erythrocytes. RESULTS: Ganciclovir disposition was characterized by apparent total body clearance of 3.3 and 5.8 L/h, terminal half-life of 16.9 and 14.1 h, and apparent volume of distribution of 60.3 and 104.9 L in Patients 1 and 2, respectively. The observed sieving coefficient was 1.05 and 0.96, and the haemofiltration clearance was 3.3 and 3.1 L/h. In vitro experiments confirmed rapid efflux of ganciclovir from red blood cells into plasma, increasing the apparent efficacy of haemofiltration. CONCLUSIONS: A valganciclovir dosage of 450 mg every 48 h appears adequate for patients under CRRT requiring prophylaxis for CMV infection, providing concentration levels in the range reported for 900 mg once daily dosing outside renal failure.
Resumo:
BACKGROUND: Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to be normal, although structural lung abnormalities are often detectable. We hypothesized that this discrepancy is due to inadequate algorithms of the available software package. AIM: Our aim was to challenge the validity of these software algorithms. METHODS: We compared multiple breath washout (MBW) results of current software algorithms (automatic modus) to refined algorithms (manual modus) in 17 asymptomatic infants with CF, and 24 matched healthy term-born infants. The main difference between these two analysis methods lies in the calculation of the molar mass differences that the system uses to define the completion of the measurement. RESULTS: In infants with CF the refined manual modus revealed clearly elevated LCI above 9 in 8 out of 35 measurements (23%), all showing LCI values below 8.3 using the automatic modus (paired t-test comparing the means, P < 0.001). Healthy infants showed normal LCI values using both analysis methods (n = 47, paired t-test, P = 0.79). The most relevant reason for false normal LCI values in infants with CF using the automatic modus was the incorrect recognition of the end-of-test too early during the washout. CONCLUSION: We recommend the use of the manual modus for the analysis of MBW outcomes in infants in order to obtain more accurate results. This will allow appropriate use of infant lung function results for clinical and scientific purposes. Pediatr Pulmonol. 2015; 50:970-977. © 2015 Wiley Periodicals, Inc.
Resumo:
OBJECTIVES: The aims of the study were to use cone beam computed tomography (CBCT) images of nasopalatine duct cysts (NPDC) and to calculate the diameter, surface area, and 3D-volume using a custom-made software program. Furthermore, any associations of dimensions of NPDC with age, gender, presence/absence of maxillary incisors/canines (MI/MC), endodontic treatment of MI/MC, presenting symptoms, and postoperative complications were evaluated. MATERIAL AND METHODS: The study comprised 40 patients with a histopathologically confirmed NPDC. On preoperative CBCT scans, curves delineating the cystic borders were drawn in all planes and the widest diameter (in millimeter), surface area (in square millimeter), and volume (in cubic millimeter) were calculated. RESULTS: The overall mean cyst diameter was 15 mm (range 7-47 mm), the mean cyst surface area 566 mm(2) (84-4,516 mm(2)), and the mean cyst volume 1,735 mm(3) (65-25,350 mm(3)). For 22 randomly allocated cases, a second measurement resulted in a mean absolute aberration of ±4.2 % for the volume, ±2.8 % for the surface, and ±4.9 % for the diameter. A statistically significant association was found for the CBCT determined cyst measurements and the need for preoperative endodontic treatment to MI/MC and for postoperative complications. CONCLUSION: In the hands of a single experienced operator, the novel software exhibited high repeatability for measurements of cyst dimensions. Further studies are needed to assess the application of this tool for dimensional analysis of different jaw cysts and lesions including treatment planning. CLINICAL RELEVANCE: Accurate radiographic information of the bone volume lost (osteolysis) due to expansion of a cystic lesion in three dimensions could help in personalized treatment planning.