144 resultados para Lebesgue and Sobolev spaces with variable exponents
Resumo:
PURPOSE: To objectively compare quantitative parameters related to image quality attained at coronary magnetic resonance (MR) angiography of the right coronary artery (RCA) performed at 7 T and 3 T. MATERIALS AND METHODS: Institutional review board approval was obtained, and volunteers provided signed informed consent. Ten healthy adult volunteers (mean age ± standard deviation, 25 years ± 4; seven men, three women) underwent navigator-gated three-dimensional MR angiography of the RCA at 7 T and 3 T. For 7 T, a custom-built quadrature radiofrequency transmit-receive surface coil was used. At 3 T, a commercial body radiofrequency transmit coil and a cardiac coil array for signal reception were used. Segmented k-space gradient-echo imaging with spectrally selective adiabatic fat suppression was performed, and imaging parameters were similar at both field strengths. Contrast-to-noise ratio between blood and epicardial fat; signal-to-noise ratio of the blood pool; RCA vessel sharpness, diameter, and length; and navigator efficiency were quantified at both field strengths and compared by using a Mann-Whitney U test. RESULTS: The contrast-to-noise ratio between blood and epicardial fat was significantly improved at 7 T when compared with that at 3 T (87 ± 34 versus 52 ± 13; P = .01). Signal-to-noise ratio of the blood pool was increased at 7 T (109 ± 47 versus 67 ± 19; P = .02). Vessel sharpness obtained at 7 T was also higher (58% ± 9 versus 50% ± 5; P = .04). At the same time, RCA vessel diameter and length and navigator efficiency showed no significant field strength-dependent difference. CONCLUSION: In our quantitative and qualitative study comparing in vivo human imaging of the RCA at 7 T and 3 T in young healthy volunteers, parameters related to image quality attained at 7 T equal or surpass those from 3 T.
Resumo:
INTRODUCTION: Several studies have shown an increased risk of type 2 diabetes among smokers. Therefore, the aim of this analysis was to assess the relationship between smoking, cumulative smoking exposure and nicotine dependence with pre-diabetes. METHODS: We performed a cross-sectional analysis of healthy adults aged 25-41 in the Principality of Liechtenstein. Individuals with known diabetes, Body Mass Index (BMI) >35 kg/m² and prevalent cardiovascular disease were excluded. Smoking behaviour was assessed by self-report. Pre-diabetes was defined as glycosylated haemoglobin between 5.7% and 6.4%. Multivariable logistic regression models were done. RESULTS: Of the 2142 participants (median age 37 years), 499 (23.3%) had pre-diabetes. There were 1,168 (55%) never smokers, 503 (23%) past smokers and 471 (22%) current smokers, with a prevalence of pre-diabetes of 21.2%, 20.9% and 31.2%, respectively (p <0.0001). In multivariable regression models, current smokers had an odds ratio (OR) of pre-diabetes of 1.82 (95% confidential interval (CI) 1.39; 2.38, p <0.0001). Individuals with a smoking exposure of <5, 5-10 and >10 pack-years had an OR (95% CI) for pre-diabetes of 1.34 (0.90; 2.00), 1.80 (1.07; 3.01) and 2.51 (1.80; 3.59) (p linear trend <0.0001) compared with never smokers. A Fagerström score of 2, 3-5 and >5 among current smokers was associated with an OR (95% CI) for pre-diabetes of 1.27 (0.89; 1.82), 2.15 (1.48; 3.13) and 3.35 (1.73; 6.48) (p linear trend <0.0001). DISCUSSION: Smoking is strongly associated with pre-diabetes in young adults with a low burden of smoking exposure. Nicotine dependence could be a potential mechanism of this relationship.
Resumo:
Normal myocardium adapts to increase of nutritional fatty acid supply by upregulation of regulatory proteins of the fatty acid oxidation pathway. Because advanced heart failure is associated with reduction of regulatory proteins of fatty acid oxidation, we hypothesized that failing myocardium may not be able to adapt to increased fatty acid intake and therefore undergo lipid accumulation, potentially aggravating myocardial dysfunction. We determined the effect of high-fat diet in transgenic mice with overexpression of angiotensinogen in the myocardium (TG1306/R1). TG1306/R1 mice develop ANG II-mediated left ventricular hypertrophy, and at one year of age approximately half of the mice present heart failure associated with reduced expression of regulatory proteins of fatty acid oxidation and reduced palmitate oxidation during ex vivo working heart perfusion. Hypertrophied hearts from TG1306/R1 mice without heart failure adapted to high-fat feeding, similarly to hearts from wild-type mice, with upregulation of regulatory proteins of fatty acid oxidation and enhancement of palmitate oxidation. There was no myocardial lipid accumulation or contractile dysfunction. In contrast, hearts from TG1306/R1 mice presenting heart failure were unable to respond to high-fat feeding by upregulation of fatty acid oxidation proteins and enhancement of palmitate oxidation. This resulted in accumulation of triglycerides and ceramide in the myocardium, and aggravation of contractile dysfunction. In conclusion, hearts with ANG II-induced contractile failure have lost the ability to enhance fatty acid oxidation in response to increased fatty acid supply. The ensuing accumulation of lipid compounds may play a role in the observed aggravation of contractile dysfunction.
Resumo:
Rotavirus (RV)-specific secretory immunoglobulin (RV-SIg) has been previously detected in serum of naturally RV infected children and shown to reflect the intestinal Ig immune response. Total plasma SIgA and plasma RV-SIg were evaluated by ELISA in children with gastroenteritis due or not due to RV infection and in 50 children vaccinated with the attenuated RIX4414 human RV vaccine and 62 placebo recipients. RV-SIg was only detected in children with evidence of previous RV infection or with acute RV gastroenteritis. Vaccinees had higher RV-SIg titers than placebo recipients and RV-SIg titers increased after the second vaccine dose. RV-SIg measured after the second dose correlated with protection when vaccinees and placebo recipients were analyzed jointly. RV-SIg may serve as a valuable correlate of protection for RV vaccines.
Resumo:
PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.
Resumo:
OBJECTIVES: The goal was to test 2 hypotheses: first, that coronary endothelial function can be measured noninvasively and abnormal function detected using clinical 3.0-T magnetic resonance imaging (MRI); and second, that the extent of local coronary artery disease (CAD), in a given patient, is related to the degree of local abnormal coronary endothelial function. BACKGROUND: Abnormal endothelial function mediates the initiation and progression of atherosclerosis and predicts cardiovascular events. However, direct measures of coronary endothelial function have required invasive assessment. METHODS: The MRI was performed in 20 healthy adults and 17 patients with CAD. Cross-sectional coronary area and blood flow were quantified before and during isometric handgrip exercise, an endothelial-dependent stressor. In 10 severe, single-vessel CAD patients, paired endothelial function was measured in the artery with severe stenosis and the contralateral artery with minimal disease. RESULTS: In healthy adults, coronary arteries dilated and flow increased with stress. In CAD patients, coronary artery area and blood flow decreased with stress (both p </= 0.02). In the paired study, coronary artery area and blood flow failed to increase during exercise in the mildly diseased vessel, but both area (p = 0.01) and blood flow (p = 0.02) decreased significantly in the severely diseased, contralateral artery. CONCLUSIONS: Endothelial-dependent coronary artery dilation and increased blood flow in healthy subjects, and their absence in CAD patients, can now be directly visualized and quantified noninvasively. Local coronary endothelial function differs between severely and mildly diseased arteries in a given CAD patient. This novel, safe method may offer new insights regarding the importance of local coronary endothelial function and improved risk stratification in patients at risk for and with known CAD.
Resumo:
PURPOSE: To analyze outcomes after right portal vein embolization extended to segment IV (right PVE + IV) before extended right hepatectomy, including liver hypertrophy, resection rates, and complications after embolization and resection, and to assess differences in outcomes with two different particulate embolic agents. MATERIALS AND METHODS: Between 1998 and 2004, transhepatic ipsilateral right PVE + IV with particles and coils was performed in 44 patients with malignant hepatobiliary disease, including metastases (n = 24), biliary cancer (n = 14), and hepatocellular carcinoma (n = 6). Right PVE + IV was considered if the future liver remnant (FLR; segments II/III with or without I) was less than 25% of the total estimated liver volume (TELV). Tris-acryl microspheres (100-700 microm; n = 21) or polyvinyl alcohol (PVA) particles (355-1,000 microm; n = 23) were administered in a stepwise fashion. Smaller particles were used to occlude distal branches, followed by larger particles to occlude proximal branches until near-complete stasis. Coils were then placed in secondary portal branches. Computed tomographic volumetry was performed before and 3-4 weeks after right PVE + IV to assess FLR hypertrophy. Liver volumes and postembolization and postoperative outcomes were measured. RESULTS: After right PVE + IV with PVA particles, FLR volume increased 45.5% +/- 40.9% and FLR/TELV ratio increased 6.9% +/- 5.6%. After right PVE + IV with tris-acryl microspheres, FLR volume increased 69.0% +/- 30.7% and FLR/TELV ratio increased 9.7% +/- 3.3%. Differences in FLR volume (P = .0011), FLR/TELV ratio (P = .027), and resection rates (P = .02) were statistically significant. Seventy-one percent of patients underwent extended right hepatectomy (86% after receiving tris-acryl microspheres, 57% after receiving PVA). Thirteen patients (29%) did not undergo resection (extrahepatic spread [n = 9], inadequate hypertrophy [n = 3], other reasons [n = 1]). No patient developed postembolization syndrome or progressive liver insufficiency after embolization or resection. One death after resection occurred as a result of sepsis and hemorrhage. Median hospital stays were 1 day after right PVE + IV and 7 days after resection. CONCLUSION: Transhepatic ipsilateral right PVE + IV with use of particles and coils is a safe, effective method for inducing contralateral hypertrophy before extended right hepatectomy. Embolization with small spherical particles provides improved hypertrophy and resection rates compared with larger, nonspherical particles.
Resumo:
Purpose To characterize in vitro the loadability, physical properties, and release of irinotecan and doxorubicin from two commercially available embolization microspheres. Materials and Methods DC Bead (500-700 μm) and Hepasphere (400-600 μm) microspheres were loaded with either doxorubicin or irinotecan solutions. Drug amount was quantified with spectrophotometry, bead elasticity was measured under compression, and bead size and loading homogeneity were assessed with microscopy image analysis. Drug release was measured over 1-week periods in saline by using a pharmacopeia flow-through method. Results Almost complete drug loading was obtained for both microsphere types and drugs. Doxorubicin-loaded DC Beads maintained their spherical shape throughout the release. In contrast, Hepaspheres showed less homogeneous doxorubicin loading and, after release, some fractured microspheres. Incomplete doxorubicin release was observed in saline over 1 week (27% ± 2 for DC beads and 18% ± 7 for Hepaspheres; P = .013). About 75% of this amount was released within 2.2 hours for both beads. For irinotecan, complete release was obtained for both types of beads, in a sustained manner over 2-3 hours for DC Beads, and in a significantly faster manner as a 7-minute burst for Hepaspheres. Conclusions The two drug-eluting microspheres could be efficiently loaded with both drugs. Incomplete doxorubicin release was attributed to strong drug-bead ionic interactions. Weaker interactions were observed with irinotecan, which led to faster drug release.
Resumo:
Skin exposures to chemicals may lead, through percutaneous permeation, to a significant increase in systemic circulation. Skin is the primary route of entry during some occupational activities, especially in agriculture. To reduce skin exposures, the use of personal protective equipment (PPE) is recommended. PPE efficiency is characterized as the time until products permeate through material (lag time, Tlag). Both skin and PPE permeations are assessed using similar in vitro methods; the diffusion cell system. Flow-through diffusion cells were used in this study to assess the permeation of two herbicides, bentazon and isoproturon, as well as four related commercial formulations (Basagran(®), Basamais(®), Arelon(®) and Matara(®)). Permeation was measured through fresh excised human skin, protective clothing suits (suits) (Microchem(®) 3000, AgriSafe Pro(®), Proshield(®) and Microgard(®) 2000 Plus Green), and a combination of skin and suits. Both herbicides, tested by itself or as an active ingredient in formulations, permeated readily through human skin and tested suits (Tlag < 2 h). High permeation coefficients were obtained regardless of formulations or tested membranes, except for Microchem(®) 3000. Short Tlag, were observed even when skin was covered with suits, except for Microchem(®) 3000. Kp values tended to decrease when suits covered the skin (except when Arelon(®) was applied to skin covered with AgriSafe Pro and Microgard(®) 2000), suggesting that Tlag alone is insufficient in characterizing suits. To better estimate human skin permeations, in vitro experiments should not only use human skin but also consider the intended use of the suit, i.e., the active ingredient concentrations and type of formulations, which significantly affect skin permeation.
Resumo:
Screening for colorectal cancer (CRC) is associated with reduced CRC mortality, but low screening rates have been reported in several settings. The aim of the study was to assess predictors of low CRC screening in Switzerland. A retrospective cohort of a random sample of 940 patients aged 50-80 years followed for 2 years from four Swiss University primary care settings was used. Patients with illegal residency status and a history of CRC or colorectal polyps were excluded. We abstracted sociodemographic data of patients and physicians, patient health status, and indicators derived from RAND's Quality Assessment Tools from medical charts. We defined CRC screening as colonoscopy in the last 10 years, flexible sigmoidoscopy in the last 5 years, or fecal occult blood testing in the last 2 years. We used bivariate and multivariate logistic regression analyses. Of 940 patients (mean age 63.9 years, 42.7% women), 316 (33.6%) had undergone CRC screening. In multivariate analysis, birthplace in a country outside of Western Europe and North America [odds ratio (OR) 0.65, 95% confidence interval (CI) 0.45-0.97], male sex of the physician in charge (OR 0.67, 95% CI 0.50-0.91), BMI 25.0-29.9 kg/m (OR 0.66, CI 0.46-0.96) and at least 30.0 kg/m (OR 0.61, CI 0.40-0.90) were associated with lower CRC screening rates. Obesity, overweight, birthplace outside of Western Europe and North America, and male sex of the physician in charge were associated with lower CRC screening rates in Swiss University primary care settings. Physician perception of obesity and its impact on their recommendation for CRC screening might be a target for further research.
Higher-order expansions for compound distributions and ruin probabilities with subexponential claims
Resumo:
The aim of this study was to compare the diagnostic efficiency of plain film and spiral CT examinations with 3D reconstructions of 42 tibial plateau fractures and to assess the accuracy of these two techniques in the pre-operative surgical plan in 22 cases. Forty-two tibial plateau fractures were examined with plain film (anteroposterior, lateral, two obliques) and spiral CT with surface-shaded-display 3D reconstructions. The Swiss AO-ASIF classification system of bone fracture from Muller was used. In 22 cases the surgical plans and the sequence of reconstruction of the fragments were prospectively determined with both techniques, successively, and then correlated with the surgical reports and post-operative plain film. The fractures were underestimated with plain film in 18 of 42 cases (43%). Due to the spiral CT 3D reconstructions, and precise pre-operative information, the surgical plans based on plain film were modified and adjusted in 13 cases among 22 (59%). Spiral CT 3D reconstructions give a better and more accurate demonstration of the tibial plateau fracture and allows a more precise pre-operative surgical plan.