61 resultados para LEAK DETECTORS
Resumo:
Major burns are characterized by an initial capillary leak which requires fluid resuscitation for hemodynamic stabilisation. While under-resuscitation was the major cause of death until the 80ies, over-resuscitation has become an important source of complications: abdominal compartment syndrome, escharotomies, impaired gas exchange and prolonged mechanical ventilation and hospital stay. The fluid creep started in the 90ies with an increasing proportion of the first 24 hours' fluid delivery above the 4 ml/kg/% BSA Parkland prediction. The first alerts were published under the form of case reports of increased mortality due to abdominal compartment syndrome and respiratory failure. The paper analyses the causes of this fluid creep, and the ways to prevent it, which includes rationing prehospital fluid delivery, avoiding early colloids and permissive hypovolemia.
Resumo:
We developed a semiquantitative job exposure matrix (JEM) for workers exposed to polychlorinated biphenyls (PCBs) at a capacitor manufacturing plant from 1946 to 1977. In a recently updated mortality study, mortality of prostate and stomach cancer increased with increasing levels of cumulative exposure estimated with this JEM (trend p values = 0.003 and 0.04, respectively). Capacitor manufacturing began with winding bales of foil and paper film, which were placed in a metal capacitor box (pre-assembly), and placed in a vacuum chamber for flood-filling (impregnation) with dielectric fluid (PCBs). Capacitors dripping with PCB residues were then transported to sealing stations where ports were soldered shut before degreasing, leak testing, and painting. Using a systematic approach, all 509 unique jobs identified in the work histories were rated by predetermined process- and plant-specific exposure determinants; then categorized based on the jobs' similarities (combination of exposure determinants) into 35 job exposure categories. The job exposure categories were ranked followed by a qualitative PCB exposure rating (baseline, low, medium, and high) for inhalation and dermal intensity. Category differences in other chemical exposures (solvents, etc.) prevented further combining of categories. The mean of all available PCB concentrations (1975 and 1977) for jobs within each intensity rating was regarded as a representative value for that intensity level. Inhalation (in microgram per cubic milligram) and dermal (unitless) exposures were regarded as equally important. Intensity was frequency adjusted for jobs with continuous or intermittent PCB exposures. Era-modifying factors were applied to the earlier time periods (1946-1974) because exposures were considered to have been greater than in later eras (1975-1977). Such interpolations, extrapolations, and modifying factors may introduce non-differential misclassification; however, we do believe our rigorous method minimized misclassification, as shown by the significant exposure-response trends in the epidemiologic analysis.
Resumo:
PURPOSE: Patients with locally advanced rectal carcinoma are at risk for both local recurrence and distant metastases. We demonstrated the efficacy of preoperative hyperfractionated accelerated radiotherapy (HART). In this Phase I trial, we aimed at introducing chemotherapy early in the treatment course with both intrinsic antitumor activity and a radiosensitizer effect. METHODS AND MATERIALS: Twenty-eight patients (19 males; median age 63, range 28-75) with advanced rectal carcinoma (cT3: 24; cT4: 4; cN+: 12; M1: 5) were enrolled, including 8 patients treated at the maximally tolerated dose. Escalating doses of CPT-11 (30-105 mg/m(2)/week) were given on Days 1, 8, and 15, and concomitant HART (41.6 Gy, 1.6 Gy bid x 13 days) started on Day 8. Surgery was to be performed within 1 week after the end of radiochemotherapy. RESULTS: Twenty-six patients completed all preoperative radiochemotherapy as scheduled; all patients underwent surgery. Dose-limiting toxicity was diarrhea Grade 3 occurring at dose level 6 (105 mg/m(2)). Hematotoxicity was mild, with only 1 patient experiencing Grade 3 neutropenia. Postoperative complications (30 days) occurred in 7 patients, with an anastomotic leak rate of 22%. CONCLUSIONS: The recommended Phase II dose of CPT-11 in this setting is 90 mg/m(2)/week. Further Phase II exploration at this dose is warranted.
Resumo:
Objective:This review assesses the presentation,management, and outcome of delayed postpancreatectomy hemorrhage (PPH) and suggests a novel algorithm as possible standard of care.Methods: An electronic search of Medline and Embase databases from January 1990 to February 2010 was undertaken. A random-effect meta-analysis for success rate and mortality of laparotomy vs. interventional radiology after delayed PPH was performed.Results: Fifteen studies including 248 patients with delayed PPH were included. Its incidence was 3?3%. A sentinel bleed heralding a delayed PPH was observed in 45% of cases. Pancreatic leaks or intraabdominal abscesses were found in 62%. Interventional radiology was attempted in 41%, and laparotomy was undertaken in 49%. On meta-analysis comparing laparotomy vs. interventional radiology, no significant difference could be observed in term of complete hemostasis (76% vs. 80%; P = 0?35). A statistically significant difference favored interventional radiology vs. laparotomy in term of mortality (22% vs. 47%; P = 0?02).Conclusion: Proper and early management of postoperative complications, such as pancreatic leak and intraabdominal abscess, minimizes the risk of delayed PPH. Sentinel bleeding needs to be thoroughly investigated. If a pseudoaneurysm is detected, it has to be treated by interventional angiography, in order to prevent a further delayed PPH. Early angiography and embolization or stenting is safe and should be the procedure of choice. Surgery remains a therapeutic option if no interventional radiology is available, or patients cannot be resuscitated for an interventional treatment.
Resumo:
Tracheobronchial aspergillosis is a rare entity mainly observed in immune-compromised patients or those who have undergone transplantation. It may cause airway ulcerations or bleeding. We report the case of a 17-year-old patient receiving chemotherapy for acute lymphoblastic leukemia who presented with right-sided tension pneumothorax. Chest tube drainage revealed a massive air leak without reexpansion of the lung, and bronchoscopy showed a 15- × 15-mm defect of the distal trachea related to aspergillosis infection. The defect was closed by an intrathoracic transposition of a pedicled latissimus dorsi muscle flap, which was sutured into the debrided defect followed by temporary endotracheal stenting and antifungal medication.
Resumo:
Mountainous areas are often covered by little evolved soils from which deposited radionuclides can potentially leak into the vadose zone. In the Swiss Jura mountains, we observed unusual isotopic ratios of nuclear weapon test (NWTs) fallout with an apparent loss of NWTs plutonium relative to &supl;³⁷Cs of Chernobyl origin in thinner soils. Here, we studied the karstic watershed of a vauclusian spring to determine the residence times of plutonium, ²⁴&supl;Am, and ⁹⁰Sr deposited by global fallout and their respective mobility in carbonaceous soils. The results show that ⁹⁰Sr is washed most efficiently from the watershed with a residence time of several hundred years. The estimated plutonium residence time is more than 10 times higher (in the range of 5000-10,000 years), and the ²⁴&supl;Am residence time is double that of plutonium. The spring water ²⁴&supl;Am/²³⁹+²⁴⁰Pu isotopic ratio is lower (0.12 - 0.28) than found in watershed soils (0.382 ± 0.077). Similar differences are found in aquatic mosses (²⁴&supl;Am/²³⁹+²⁴⁰Pu isotopic ratio 0.05-0.12), which are permanently submerged in spring waters. In contrast to plutonium, ⁹⁰Sr is leached from these mosses with 0.5M HCl, demonstrating that strontium is probably associated with calcium carbonate precipitations on the mosses. The higher plutonium to americium isotopic ratio found in the samples of spring water and mosses at the outlet of the karst shows that plutonium mobility is enhanced.
Resumo:
PURPOSE: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. METHODS: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectors and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). RESULTS: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. CONCLUSIONS: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.
Resumo:
BACKGROUND AND AIM OF THE STUDY: Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS: A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS: Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION: Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.
Resumo:
Five selective serotonin reuptake inhibitors (SSRIs) have been introduced recently: citalopram, fluoxetine, fluvoxamine, paroxetine and sertraline. Although no therapeutic window has been defined for SSRIs, in contrast to tricyclic antidepressants, analytical methods for therapeutic drug monitoring of SSRIs are useful in several instances. SSRIs differ widely in their chemical structure and in their metabolism. The fact that some of them have N-demethylated metabolites, which are also SSRIs, requires that methods be available which allow therapeutic drug monitoring of the parent compounds and of these active metabolites. most procedures are based on prepurification of the SSRIs by liquid-liquid extraction before they are submitted to separation by chromatographic procedures (high-performance liquid chromatography, gas chromatography, thin layer chromatography) and detection by various detectors (UV, fluorescence, electrochemical detector, nitrogen-phosphorus detector, mass spectrometry). This literature review shows that most methods allow quantitative determination of SSRIs in plasma, in the lower ng/ml range, and that they are, therefore, suitable for therapeutic drug monitoring purposes of this category of drugs.
Resumo:
Evaluation of image quality (IQ) in Computed Tomography (CT) is important to ensure that diagnostic questions are correctly answered, whilst keeping radiation dose to the patient as low as is reasonably possible. The assessment of individual aspects of IQ is already a key component of routine quality control of medical x-ray devices. These values together with standard dose indicators can be used to give rise to 'figures of merit' (FOM) to characterise the dose efficiency of the CT scanners operating in certain modes. The demand for clinically relevant IQ characterisation has naturally increased with the development of CT technology (detectors efficiency, image reconstruction and processing), resulting in the adaptation and evolution of assessment methods. The purpose of this review is to present the spectrum of various methods that have been used to characterise image quality in CT: from objective measurements of physical parameters to clinically task-based approaches (i.e. model observer (MO) approach) including pure human observer approach. When combined together with a dose indicator, a generalised dose efficiency index can be explored in a framework of system and patient dose optimisation. We will focus on the IQ methodologies that are required for dealing with standard reconstruction, but also for iterative reconstruction algorithms. With this concept the previously used FOM will be presented with a proposal to update them in order to make them relevant and up to date with technological progress. The MO that objectively assesses IQ for clinically relevant tasks represents the most promising method in terms of radiologist sensitivity performance and therefore of most relevance in the clinical environment.
Resumo:
BACKGROUND: One of the most frequent complications of pancreaticoduodenectomy (PD) is delayed gastric emptying (DGE). The study aim was to evaluate the impact of the type of gastro/duodenojejunal reconstruction (antecolic vs. retrocolic) after PD on DGE incidence. METHODS: A systematic review was made according to the PRISMA guidelines. Randomized controlled trials (RCTs) comparing antecolic vs. retrocolic reconstruction were included irrespective of the PD techniques. A meta-analysis was then performed. RESULTS: Six RCTs were included for a total of 588 patients. The overall quality was good. General risk of bias was low. DGE was not statistically significantly different between the antecolic and retrocolic group (OR 0.6, 95% CI 0.31-1.16, p = 0.13). The other main surgery-related complications (pancreatic fistula, hemorrhage, intra-abdominal abscess, bile leak and wound infection) were not dependent on the reconstruction route (OR 0.84, 95% CI 0.41-1.70, p = 0.63). No statistically significant difference in terms of length of hospital stay was found between the 2 groups. There was also no difference of DGE incidence if only pylorus-preserving PD was considered and between the DGE grades A, B or C. CONCLUSION: This meta-analysis shows that antecolic reconstruction after PD is not superior to retrocolic reconstruction in terms of DGE.
Resumo:
Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity aortic valve and mitral ring implantation.
Resumo:
NlmCategory="UNASSIGNED">Rapid deployment aortic valve replacement (RDAVR) with the use of rapid deployment valve systems represents a smart alternative to the use of standard aortic bioprosthesis for aortic valve replacement. Nevertheless, its use is still debatable in patients with pure aortic valve regurgitation or true bicuspid aortic valve because of the risk of postoperative paravalvular leak. To address this issue, an optimal annulus-valve size match seems to be the ideal surgical strategy. This article describes a new technique developed to stabilize the aortic annulus and prevent paravalvular leak after RDAVR. To confirm the feasibility, this technique was performed in six patients with severe symptomatic aortic stenosis who were scheduled to undergo aortic valve replacement at our center. All patients survived surgery and were discharged from the hospital. There were no new intracardiac conduction system disturbances observed, and a permanent pacemaker implantation was not required in any of the patients. The intraoperative and postoperative echocardiogram confirmed successful positioning of the valve, and no paravalvular leak was observed. In this preliminary experience, RDAVR through a full sternotomy or an upper hemisternotomy approach with the use of aortic annulus stabilization technique was safe, and no leak was observed. Future studies on large series of patients are necessary to confirm the safety and effectiveness of this technique in preventing paravalvular leak in patients with true bicuspid aortic valves or pure aortic regurgitation.
Resumo:
Bacterial programmed cell death and quorum sensing are direct examples of prokaryote group behaviors, wherein cells coordinate their actions to function cooperatively like one organism for the benefit of the whole culture. We demonstrate here that 2-n-heptyl-4-hydroxyquinoline-N-oxide (HQNO), a Pseudomonas aeruginosa quorum-sensing-regulated low-molecular-weight excreted molecule, triggers autolysis by self-perturbing the electron transfer reactions of the cytochrome bc1 complex. HQNO induces specific self-poisoning by disrupting the flow of electrons through the respiratory chain at the cytochrome bc1 complex, causing a leak of reducing equivalents to O2 whereby electrons that would normally be passed to cytochrome c are donated directly to O2. The subsequent mass production of reactive oxygen species (ROS) reduces membrane potential and disrupts membrane integrity, causing bacterial cell autolysis and DNA release. DNA subsequently promotes biofilm formation and increases antibiotic tolerance to beta-lactams, suggesting that HQNO-dependent cell autolysis is advantageous to the bacterial populations. These data identify both a new programmed cell death system and a novel role for HQNO as a critical inducer of biofilm formation and antibiotic tolerance. This newly identified pathway suggests intriguing mechanistic similarities with the initial mitochondrial-mediated steps of eukaryotic apoptosis.
Resumo:
Gram-negative bacteria represent a major group of pathogens that infect all eukaryotes from plants to mammals. Gram-negative microbe-associated molecular patterns include lipopolysaccharides and peptidoglycans, major immunostimulatory determinants across phyla. Recent advances have furthered our understanding of Gram-negative detection beyond the well-defined pattern recognition receptors such as TLR4. A B-type lectin receptor for LPS and Lysine-motif containing receptors for peptidoglycans were recently added to the plant arsenal. Caspases join the ranks of mammalian cytosolic immune detectors by binding LPS, and make TLR4 redundant for septic shock. Fascinating bacterial evasion mechanisms lure the host into tolerance or promote inter-bacterial competition. Our review aims to cover recent advances on bacterial messages and host decoding systems across phyla, and highlight evolutionarily recurrent strategies.