62 resultados para Implant-supported restoration
Resumo:
OBJECTIVE: To evaluate the safety and efficacy of 2 doses of dexamethasone intravitreal implant (DEX implant) for treatment of noninfectious intermediate or posterior uveitis. METHODS: In this 26-week trial, eyes with noninfectious intermediate or posterior uveitis were randomized to a single treatment with a 0.7-mg DEX implant (n = 77), 0.35-mg DEX implant (n = 76), or sham procedure (n = 76). MAIN OUTCOME MEASURE: The main outcome measure was the proportion of eyes with a vitreous haze score of 0 at week 8. RESULTS: The proportion of eyes with a vitreous haze score of 0 at week 8 was 47% with the 0.7-mg DEX implant, 36% with the 0.35-mg DEX implant, and 12% with the sham (P < .001); this benefit persisted through week 26. A gain of 15 or more letters from baseline best-corrected visual acuity was seen in significantly more eyes in the DEX implant groups than the sham group at all study visits. The percentage of eyes with intraocular pressure of 25 mm Hg or more peaked at 7.1% for the 0.7-mg DEX implant, 8.7% for the 0.35-mg DEX implant, and 4.2% for the sham (P > .05 at any visit). The incidence of cataract reported in the phakic eyes was 9 of 62 (15%) with the 0.7-mg DEX implant, 6 of 51 (12%) with the 0.35-mg DEX implant, and 4 of 55 (7%) with the sham (P > .05). CONCLUSIONS: In patients with noninfectious intermediate or posterior uveitis, a single DEX implant significantly improved intraocular inflammation and visual acuity persisting for 6 months. Application to Clinical Practice Dexamethasone intravitreal implant may be used safely and effectively for treatment of intermediate and posterior uveitis. Trial Registration clinicaltrials.gov Identifier: NCT00333814.
Resumo:
PURPOSE: To study prospectively the success rate and complications of deep sclerectomy with collagen implant (DSCI). SETTING: Glaucoma Unit, Department of Ophthalmology, Hôpital Ophtalmique Jules Gonin, University of Lausanne, Lausanne, Switzerland. METHODS: This nonrandomized prospective trial comprised 105 eyes of 105 patients with medically uncontrolled primary and secondary open-angle glaucoma. Visual acuity, intraocular pressure (IOP), and slitlamp examinations were performed before surgery and after surgery at 1 and 7 days, and 1, 3, 6, 9, 12, 18, 24, 30, 36, 48, 54, 60, 66, 72, 78, 84, 90, and 96 months. Visual field examinations were repeated every 6 months. RESULTS: Mean follow-up period was 64 months +/- 26.6 (SD). Mean preoperative IOP was 26.8 +/- 7.7 mm Hg, and mean postoperative IOP was 5.2 +/- 3.35 mm Hg at day 1 and 12 +/- 3 mm Hg at month 78. At 96 months, the qualified success rate (ie, patients who achieved IOP <21 mm Hg with and without medication) was 91%, and the complete success rate (ie, IOP <21 mm Hg without medication) was 57%. At 96 months, 34% of patients had an IOP <21 mm Hg with medication. Fifty-one patients (49%) achieved an IOP < or =15 mm Hg without medication. Neodymium:YAG goniopuncture was performed in 54 patients (51%); mean time of goniopuncture performance was 21 months, and mean IOP before goniopuncture was 20 mm Hg, dropping to 11 mm Hg after goniopuncture. No shallow or flat anterior chamber, endophthalmitis, or surgery-induced cataract was observed. However, 26 patients (25%) showed a progression of preexisting senile cataract (mean time 26 months; range 18 to 37 months). Injections of 5-fluorouracil were administered to 25 patients (23%) who underwent DSCI to salvage encysted blebs. Mean number of medications per patient was reduced from 2.3 +/- 0.7 to 0.5 +/- 0.7 (signed rank P<.0001). CONCLUSION: Deep sclerectomy with collagen implant appears to provide stable and reasonable control of IOP at long-term follow-up with few immediate postoperative complications.
Resumo:
Between 1995 and 2005, the number of aortic aneurysms treated annually using endovascular techniques (EVAR) increased from 0 to 50, including all aortic stages. Our organization includes a large team of surgeons, a stock of three complete families of endoprostheses (straight, conical and bifurcated), a mobile trolley with accessories (arterial introducer/introducer sheath, guide wire, catheters, balloons, etc.) and an appliance on wheels for intravascular ultrasound examination (IVUS). This appliance, together with a mobile fluoroscopy device (c-arm), allows endovascular aneurysms analysis of every operating room in our institution, usually without angiography or the use of contrast medium. In general, we are therefore not depending on substantial preoperative imaging in order to identify candidates for endovascular aneurysms repair and can treat abdominal and thoracic aortic ruptures without delay. For endovascular aortic aneurysms repair we distinguish between process steps on the one hand (determining indications, imaging of the access vessels, measurement using IVUS and road mapping via fluoroscopy, selection of implant, implant insertion, positioning, setting the implant, determining success, reconstruction of the access vessel and follow-up) and the level of competence on the other (assistant, senior and directing physicians). Our ultrasound supported technique for endovascular aneurysms repair has been successfully brought to other hospitals using an IVUS transporter and telementoring.
Resumo:
PURPOSE: To evaluate the safety and efficacy of an intravitreal fluocinolone acetonide (FA) implant compared with standard therapy in subjects with noninfectious posterior uveitis (NIPU). DESIGN: Randomized, controlled, phase 2b/3, open-label, multicenter superiority trial. PARTICIPANTS: Subjects with unilateral or bilateral NIPU. METHODS: One hundred forty subjects received either a 0.59-mg FA intravitreal implant (n = 66) or standard of care (SOC; n = 74) with either systemic prednisolone or equivalent corticosteroid as monotherapy (> or =0.2 mg/kg daily) or, if judged necessary by the investigator, combination therapy with an immunosuppressive agent plus a lower dose of prednisolone or equivalent corticosteroid (> or =0.1 mg/kg daily). MAIN OUTCOME MEASURES: Time to first recurrence of uveitis. RESULTS: Eyes that received the FA intravitreal implant experienced delayed onset of observed recurrence of uveitis (P<0.01) and a lower rate of recurrence of uveitis (18.2% vs. 63.5%; P< or =0.01) compared with SOC study eyes. Adverse events frequently observed in implanted eyes included elevated intraocular pressure (IOP) requiring IOP-lowering surgery (occurring in 21.2% of implanted eyes) and cataracts requiring extraction (occurring in 87.8% of phakic implanted eyes). No treatment-related nonocular adverse events were observed in the implant group, whereas such events occurred in 25.7% of subjects in the SOC group. CONCLUSIONS: The FA intravitreal implant provided better control of inflammation in patients with uveitis compared with systemic therapy. Intraocular pressure and lens clarity of implanted eyes need close monitoring in patients receiving the FA intravitreal implant.
Resumo:
Purpose: The aim of this review was to systematically evaluate and compare the frequency of veneer chipping and core fracture of zirconia fixed dental prostheses (FOPS) and porcelain-fused-to-metal (PFM) FDPs and determine possible influencing factors. Materials and Methods: The SCOPUS database and International Association of Dental Research abstracts were searched for clinical studies involving zirconia and PFM FDPs. Furthermore, studies that were integrated into systematic reviews on PFM FDPs were also evaluated. The principle investigators of any clinical studies on zirconia FDPs were contacted to provide additional information. Based on the available information for each FOP, a data file was constructed. Veneer chipping was divided into three grades (grade 1 = polishing, grade 2 = repair, grade 3 = replacement). To assess the frequency of veneer chipping and possible influencing factors, a piecewise exponential model was used to adjust for a study effect. Results: None of the studies on PFM FDPs (reviews and additional searching) sufficiently satisfied the criteria of this review to be included. Thirteen clinical studies on zirconia FDPs and two studies that investigated both zirconia and PFM FDPs were identified. These studies involved 664 zirconia and 134 PFM FDPs at baseline. Follow-up data were available for 595 zirconia and 127 PFM FDPs. The mean observation period was approximately 3 years for both groups. The frequency of core fracture was less than 1% in the zirconia group and 0% in the PFM group. When all studies were included, 142 veneer chippings were recorded for zirconia FDPs (24%) and 43 for PFM FDPs (34%). However, the studies differed extensively with regard to veneer chipping of zirconia: 85% of all chippings occurred in 4 studies, and 43% of all chippings included zirconia FDPs. If only studies that evaluated both types of core materials were included, the frequency of chipping was 54% for the zirconia-supported FDPs and 34% for PFM FDPs. When adjusting the survival rate for the study effect, the difference between zirconia and PFM FDPs was statistically significant for all grades of chippings (P = .001), as well as for chipping grade 3 (P = .02). If all grades of veneer chippings were taken into account, the survival of PFM FDPs was 97%, while the survival rate of the zirconia FDPs was 90% after 3 years for a typical study. For both PFM and zirconia FDPs, the frequency of grades 1 and 2 veneer chippings was considerably higher than grade 3. Veneer chipping was significantly less frequent in pressed materials than in hand-layered materials, both for zirconia and PFM FDPs (P = .04). Conclusions: Since the frequency of veneer chipping was significantly higher in the zirconia FDPs than PFM FDPs, and as refined processing procedures have started to yield better results in the laboratory, new clinical studies with these new procedures must confirm whether the frequency of veneer chipping can be reduced to the level of PFM. Int J Prosthodont 2010;23:493-502
Resumo:
PURPOSE: To evaluate the clinical outcome of patients who received a Baerveldt implant for refractory glaucoma and to identify factors which may influence the outcome. METHODS: Retrospective study including 51 eyes of 51 patients with medically uncontrolled glaucoma who underwent Baerveldt implant surgery between June 1994 and December 1998. Criteria for success were intraocular pressure (IOP) < or = 21 mmHg and > 6 mmHg, necessity of further antiglaucoma medications, absence of additional glaucoma surgery and no loss of light perception. RESULTS: Over a mean follow-up of 37.6 (SD: +/-18.8) months, the mean intraocular pressure decreased from 34.8 (+/-12.5) mmHg to 14.0 (+/-4.3) mmHg at month 60. Qualified success rate, achieved when IOP was below 21 mmHg and higher than 6 mmHg with medications was 25/48 (52%), complete success rate (same IOP limits without medication) was 14/48 (29%). Seven eyes had major complications or lost light perception. Postoperative visual acuity improved or remained within one Snellen line of the preoperative visual acuity in 35 patients (73%). Factors associated with a better prognosis were a preoperative visual acuity better than 20/400 and etiology of glaucoma. CONCLUSION: The Baerveldt implant is effective in lowering intraocular pressure in most patients with refractory glaucoma. Long-term results are promising with satisfactory IOP control.
Resumo:
PURPOSE: To compare the efficacy and safety of T-Flux implant versus Healon GV in deep sclerectomy. METHODS: Randomized prospective trial of 23 eyes of 20 patients with medically uncontrolled open angle glaucoma over a period of 24 months, who underwent deep sclerectomy with either Healon GV or T-Flux implant. RESULTS: Mean postoperative intraocular pressure was 13.2 +/- 3.0 mm Hg with T-Flux implant (group 1) and 12.2 +/- 3.5 mm Hg with Healon GV (group 2), with a pressure reduction of 53.0% in group 1 (13.2 mm Hg vs. 28.1 mm Hg) and of 48.1% in group 2 (12.2 mm Hg vs. 23.5 mm Hg). Qualified and complete successes were 100% and 95.4% respectively. Pressures equal to or less than 15 mm Hg were 81.8% in group 1 and 90.9% in group 2 with or without treatment, and 63.6% in group 1 and 81.8% in group 2 without treatment. The number of glaucoma treatments dropped from 2.5 +/- 0.9 to 0.4 +/- 0.7 in group 1 and from 2.2 +/- 1.0 to 0.2 +/- 0.4 in group 2. The goniopuncture rate was 63.6% in group 1 and 36.4% in group 2, with a mean pressure drop of 6.1 +/- 3.9 mm Hg and 3.25 +/- 1.2 mm Hg respectively. Overall, slit-lamp diagnosed surgery-related complications included positive Seidel (13.6%), hyphaema (22.7%), choroidal detachment, and iris incarceration (4.5% each). At 2 years, ultrasound biomicroscopy showed mainly low reflective (40.1%) and flattened (36.4%) blebs. Principally latter ones were associated with the need for adjunctive treatment. A hypoechoic area in the suprachoroidal space was seen in at least 59.1% of eyes at 2 years and was not associated with lower intraocular pressure. CONCLUSION: Deep sclerectomy is an effective and safe surgery. However, longer follow up and larger study groups are required to assess the additional benefit of nonabsorbable implants.
Resumo:
River restoration can enhance river dynamics, environmental heterogeneity and biodiversity, but the underlying processes governing the dynamic changes need to be understood to ensure that restoration projects meet their goals, and adverse effects are prevented. In particular, we need to comprehend how hydromorphological variability quantitatively relates to ecosystem functioning and services, biodiversity as well as ground-and surface water quality in restored river corridors. This involves (i) physical processes and structural properties, determining erosion and sedimentation, as well as solute and heat transport behavior in surface water and within the subsurface; (ii) biogeochemical processes and characteristics, including the turnover of nutrients and natural water constituents; and (iii) ecological processes and indicators related to biodiversity and ecological functioning. All these aspects are interlinked, requiring an interdisciplinary investigation approach. Here, we present an overview of the recently completed RECORD (REstored CORridor Dynamics) project in which we combined physical, chemical, and biological observations with modeling at a restored river corridor of the perialpine Thur River in Switzerland. Our results show that river restoration, beyond inducing morphologic changes that reshape the river bed and banks, triggered complex spatial patterns of bank infiltration, and affected habitat type, biotic communities and biogeochemical processes. We adopted an interdisciplinary approach of monitoring the continuing changes due to restoration measures to address the following questions: How stable is the morphological variability established by restoration? Does morphological variability guarantee an improvement in biodiversity? How does morphological variability affect biogeochemical transformations in the river corridor? What are some potential adverse effects of river restoration? How is river restoration influenced by catchment-scale hydraulics [GRAPHICS] and which feedbacks exist on the large scale? Beyond summarizing the major results of individual studies within the project, we show that these overarching questions could only be addressed in an interdisciplinary framework.
Resumo:
Diabetic macular edema (DME) is a frequent complication of diabetic retinopathy and may cause severe visual loss. In this article, we examine the pathophysiology of DME and review various treatment options, such as laser photocoagulation, anti-vascular endothelial growth factor (VEGF) receptor antibodies, and steroids including ILUVIEN(®), which is a new sustained-release, non biodegradable, injectable, intravitreal micro-implant containing fluocinolone acetonide. The results of the FAME (Fluocinolone Acetonide in Diabetic Macular Edema) studies, conducted to evaluate the efficacy and safety of ILUVIEN(®) in DME, are discussed.
Resumo:
BACKGROUND: ALK-negative anaplastic large cell lymphoma associated with breast implant (i-ALCL) has been recently recognized as a distinct entity. Among 43 830 lymphomas registered in the French Lymphopath network since 2010, 300 breast lymphomas comprising 25 peripheral T-cell lymphomas (PTCL) were reviewed. Among PTCL, ALK-negative ALCL was the most frequent and all of them were associated with breast implants. PATIENTS AND METHODS: Since 2010, all i-ALCL cases were collected from different institutions through Lymphopath. Immuno-morphologic features, molecular data and clinical outcome of 19 i-ALCLs have been retrospectively analyzed. RESULTS: The median age of the patients was 61 years and the median length between breast implant and i-ALCL was 9 years. Most implants were silicone-filled and textured. Implant removal was performed in 17 out of 19 patients with additional treatment based on mostly CHOP or CHOP-like chemotherapy regimens (n = 10/19) or irradiation (n = 1/19). CHOP alone or ABVD following radiation without implant removal have been given in two patients. The two clinical presentations, i.e. effusion and less frequently tumor mass correlated with distinct histopathologic features: in situ i-ALCL (anaplastic cell proliferation confined to the fibrous capsule) and infiltrative i-ALCL (pleomorphic cells massively infiltrating adjacent tissue with eosinophils and sometimes Reed-Sternberg-like cells mimicking Hodgkin lymphoma). Malignant cells were CD30-positive, showed a variable staining for EMA and were ALK negative. Most cases had a cytotoxic T-cell immunophenotype with variable T-cell antigen loss and pSTAT3 nuclear expression. T-cell receptor genes were clonally rearranged in 13 out of 13 tested cases. After 18 months of median follow-up, the 2-year overall survival for in situ and infiltrative i-ALCL was 100% and 52.5%, respectively. CONCLUSIONS: In situ i-ALCLs have an indolent clinical course and generally remain free of disease after implant removal. However, infiltrative i-ALCLs could have a more aggressive clinical course that might require additional therapy to implant removal.