243 resultados para Fibre comparison
Resumo:
Prepro-RFRP-containing neurons have recently been described in the mammalian brain. These neurons are only found in the tuberal hypothalamus. In this work, we have provided a detailed analysis of the distribution of cells expressing the RFRP mRNA, and found them in seven anatomical structures of the tuberal hypothalamus. No co-expression with melanin-concentrating hormone (MCH) or hypocretin (Hcrt), that are also described in neurons of the tuberal hypothalamus, was observed. Using the BrdU method, we found that all RFRP cell bodies are generated between E13 and E14. Thus, RFRP neurons form a specific cell population with a complex distribution pattern in the tuberal hypothalamus. However, they are generated in one peak. These observations are discussed with data concerning the distribution and genesis of the MCH and Hcrt cell populations that are also distributed in the tuberal hypothalamus.
Resumo:
BACKGROUND: We have previously reported that the expression of circadian clock-genes increases in the cerebral cortex after sleep deprivation (SD) and that the sleep rebound following SD is attenuated in mice deficient for one or more clock-genes. We hypothesized that besides generating circadian rhythms, clock-genes also play a role in the homeostatic regulation of sleep. Here we follow the time course of the forebrain changes in the expression of the clock-genes period (per)-1, per2, and of the clock-controlled gene albumin D-binding protein (dbp) during a 6 h SD and subsequent recovery sleep in three inbred strains of mice for which the homeostatic sleep rebound following SD differs. We reasoned that if clock genes are functionally implicated in sleep homeostasis then the SD-induced changes in gene expression should vary according to the genotypic differences in the sleep rebound. RESULTS: In all three strains per expression was increased when animals were kept awake but the rate of increase during the SD as well as the relative increase in per after 6 h SD were highest in the strain for which the sleep rebound was smallest; i.e., DBA/2J (D2). Moreover, whereas in the other two strains per1 and per2 reverted to control levels with recovery sleep, per2 expression specifically, remained elevated in D2 mice. dbp expression increased during the light period both during baseline and during SD although levels were reduced during the latter condition compared to baseline. In contrast to per2, dbp expression reverted to control levels with recovery sleep in D2 only, whereas in the two other strains expression remained decreased. CONCLUSION: These findings support and extend our previous findings that clock genes in the forebrain are implicated in the homeostatic regulation of sleep and suggest that sustained, high levels of per2 expression may negatively impact recovery sleep.
Resumo:
The feasibility of three-dimensional (3D) whole-heart imaging of the coronary venous (CV) system was investigated. The hypothesis that coronary magnetic resonance venography (CMRV) can be improved by using an intravascular contrast agent (CA) was tested. A simplified model of the contrast in T(2)-prepared steady-state free precession (SSFP) imaging was applied to calculate optimal T(2)-preparation durations for the various deoxygenation levels expected in venous blood. Non-contrast-agent (nCA)- and CA-enhanced images were compared for the delineation of the coronary sinus (CS) and its main tributaries. A quantitative analysis of the resulting contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) in both approaches was performed. Precontrast visualization of the CV system was limited by the poor CNR between large portions of the venous blood and the surrounding tissue. Postcontrast, a significant increase in CNR between the venous blood and the myocardium (Myo) resulted in a clear delineation of the target vessels. The CNR improvement was 347% (P < 0.05) for the CS, 260% (P < 0.01) for the mid cardiac vein (MCV), and 430% (P < 0.05) for the great cardiac vein (GCV). The improvement in SNR was on average 155%, but was not statistically significant for the CS and the MCV. The signal of the Myo could be significantly reduced to about 25% (P < 0.001).
Resumo:
Recognition by the T-cell receptor (TCR) of immunogenic peptides (p) presented by Class I major histocompatibility complexes (MHC) is the key event in the immune response against virus-infected cells or tumor cells. A study of the 2C TCR/SIYR/H-2K(b) system using a computational alanine scanning and a much faster binding free energy decomposition based on the Molecular Mechanics-Generalized Born Surface Area (MM-GBSA) method is presented. The results show that the TCR-p-MHC binding free energy decomposition using this approach and including entropic terms provides a detailed and reliable description of the interactions between the molecules at an atomistic level. Comparison of the decomposition results with experimentally determined activity differences for alanine mutants yields a correlation of 0.67 when the entropy is neglected and 0.72 when the entropy is taken into account. Similarly, comparison of experimental activities with variations in binding free energies determined by computational alanine scanning yields correlations of 0.72 and 0.74 when the entropy is neglected or taken into account, respectively. Some key interactions for the TCR-p-MHC binding are analyzed and some possible side chains replacements are proposed in the context of TCR protein engineering. In addition, a comparison of the two theoretical approaches for estimating the role of each side chain in the complexation is given, and a new ad hoc approach to decompose the vibrational entropy term into atomic contributions, the linear decomposition of the vibrational entropy (LDVE), is introduced. The latter allows the rapid calculation of the entropic contribution of interesting side chains to the binding. This new method is based on the idea that the most important contributions to the vibrational entropy of a molecule originate from residues that contribute most to the vibrational amplitude of the normal modes. The LDVE approach is shown to provide results very similar to those of the exact but highly computationally demanding method.
Resumo:
Dans cette étude, nous avons testé la performance diagnostique d'une nouvelle technique d'analyse multiplexée qui permet la détection d'anticorps de différentes spécificités dans la même réaction. En l'absence de gold standard, nous avons choisi de comparer la performance diagnostique de l'analyse avec deux méthodes de référance que sont l'IF et EIA, et avec un consensus déterminé selon une règle de majorité entre les trois méthodes.¦393 sérums analysés par IF, conservés par congélation, ont été décongelés pour être analysés par EIA et BBA. Pour chaque sérum, les anticorps recherchés ont été les anti-VCA (Viral Capsid Antigen) IgM, anti-VCA IgG et anti-EBNA (Epstein-Barr Nuclear Associated) IgG. Les échantillons ont été classés en cinq groupes selon les résultats de l'IF : séronégatifs, infections aiguës, infections anciennes et deux types d'indéterminés.¦Pour chaque méthode, le résultat numérique (index ou titre) des analyses est converti en termes de positif, négatif ou douteux. Pour le résultat de chaque type d'anticorps, un consensus est établi selon une règle de majorité entre les trois méthodes, permettant une interprétation du stade de l'infection. Puis l'interprétation de chacune des méthodes a été comparée au consensus. Nous avons également comparé les trois méthodes les unes aux autres concernant la détection des anticorps.¦Globalement, nous observons une bonne corrélation qualitative entre les trois approches pour détecter les anti-VCA IgG et IgM. Pour pour les anti-EBNA IgG, il y a une divergence notable entre l'IF et les deux autres méthodes, l'IF apparaissant moins sensible que les autres méthodes, résultant en un nombre accru d'interprétations indéterminées du stade de l'infection.¦L'origine de cette divergence ne peut être due à une perte d'anticorps liée au stockage de longue durée des échantillons. En effet, EIA et BBA restent plus sensibles que IF, dont l'analyse a été faite sur des sérums frais.¦Cette divergence ne semble pas non plus être due aux différents antigènes utilisés par les trois méthodes. EIA et BBA utilisent le même antigène recombinant EBNA-1, alors que l'IF utilise des "cellules lymphoïdes choisies pour leur production sélective d'antigènes EBNA". Ces cellules sont probablement des cellules infectées par EBV qui devraient exprimer plus d'antigènes de latence que seul EBNA-1. Cette différence devrait donc plutôt en principe résulter en une meilleure sensibilité de l'IF par rapport aux deux autres méthodes.¦Les anti-EBNA IgG peuvent disparaître chez les patients immunocompromis chez qui se produit une réactivation d'EBV. Nous avons donc recherché le status immunitaire des patients du groupe dont les sérums étaient négatifs pour anti-EBNA IgG en IF et positifs par les autres méthodes: seulement 28 des 70 patients étaient immunocompromis.¦Par conséquent, il est probable que dans la majorité de ces résultats discordants, les anticorps anti-EBNA IgG détectés par BBA et EIA sont de vrais positifs non décelés par l'IF.¦En conclusion, BBA est meilleur que la méthode de référance qu'est l'IF, et est égal à EIA en ce qui concerne la performance diagnostique. En outre, ces deux nouvelles méthodes offrent une économie de temps en raison de manipulations moindres, et ne requièrent aucune formation en microscopie à fluorescence. Elles sont également plus économes en échantillons que IF. BBA a l'avantage de n'avoir besoin que de deux analyses pour donner un diagnostique, alors que IF et EIA ont en besoin d'une par anticorps. Enfin, BBA dispose de contrôles internes permettant de reconnaître les liaisons non antigène-spécifiques des anticorps. Par contre, BBA nécessite l'achat d'un lecteur par cytométrie de flux assez coûteux.
Resumo:
Objectives: After several years of increasing 'normalisation' of cannabis use in Switzerland at the beginning of the new millennium, a reversed tendency, marked among others by a more stringent law-enforcement, set in. The presentation examines the question of where adolescents and young adults obtained cannabis, within the context of this societal change. In addition, it compares the sources of supply for cannabis with those found in studies of other European countries. Methods: Analyses are based on data from the Swiss Cannabis Monitoring Study. As part of this longitudinal, representative population survey, more than 5000 adolescents and young adults were interviewed by telephone on the topic of cannabis. Within the total sample, 593 (2004) or 554 (2007) respectively, current cannabis users replied to the questions on sources of supply. Changes in law-enforcement and societal climate concerning cannabis are assessed based on relevant literature, media reports and parliamentary discussions. Results: Whereas 22% of cannabis users stated in 2004 that they bought their cannabis from vendors in hemp shops, this proportion drastically decreased to 6% three years later. At the same time, cannabis was obtained increasingly from friends, while the proportion of users who purchased cannabis from dealers in the alleyway, more than doubled from 6% (2004) to 13% (2007). It was male cannabis users, and in particular, young adult and frequent users, who have moved into the alleyways. Generally, users who buy cannabis in the alleyway show more cannabis-related problems than those who mainly name other sources of supply, even when adjusted for sex, age and frequency of cannabis use. Discussion: Possible consequences of these changes in cannabis supply, like the risk of merging a previously cannabis-only market with other 'harder' drugs markets, are discussed.
Resumo:
Hepatitis E virus (HEV) is responsible for many enterically transmitted viral hepatitides around the world. It is currently one of the waterborne diseases of global concern. In industrialized countries, HEV appears to be more common than previously thought, even if it is rarely virulent. In Switzerland, seroprevalence studies revealed that HEV is endemic, but no information was available on its environmental spread. The aim of this study was to investigate -using qPCR- the occurrence and concentration of HEV and three other viruses (norovirus genogroup II, human adenovirus-40 and porcine adenovirus) in influents and effluents of 31 wastewater treatment plants (WWTPs) in Switzerland. Low concentrations of HEV were detected in 40 out of 124 WWTP influent samples, showing that HEV is commonly present in this region. The frequency of HEV occurrence was higher in summer than in winter. No HEV was detected in WWTP effluent samples, which indicates a low risk of environmental contamination. HEV occurrence and concentrations were lower than those of norovirus and adenovirus. The autochthonous HEV genotype 3 was found in all positive samples, but a strain of the non-endemic and highly pathogenic HEV genotype I was isolated in one sample, highlighting the possibility of environmental circulation of this genotype. A porcine fecal marker (porcine adenovirus) was not detected in HEV positive samples, indicating that swine are not the direct source of HEV present in wastewater. Further investigations will be necessary to determine the reservoirs and the routes of dissemination of HEV.
Resumo:
OBJECTIVE: To compare three spin-echo sequences, transverse T1-weighted (T1WI), transverse fat-saturated (FS) T2-weighted (T2WI), and transverse gadolinium-enhanced (Gd) FS T1WI, for the visualisation of normal and abnormal finger A2 pulley with magnetic resonance (MR) imaging at 3 tesla (T). MATERIALS AND METHODS: Sixty-three fingers from 21 patients were consecutively investigated. Two musculoskeletal radiologists retrospectively compared all sequences to assess the visibility of normal and abnormal A2 pulleys and the presence of motion or ghost artefacts. RESULTS: Normal and abnormal A2 pulleys were visible in 94% (59/63) and 95% (60/63) on T1WI sequences, in 63% (40/63) and 60% (38/63) on FS T2WI sequences, and in 87% (55/63) and 73% (46/63) on Gd FS T1WI sequences when read by the first and second observer, respectively. Motion and ghost artefacts were higher on FS T2WI sequences. Seven among eight abnormal A2 pulleys were detected, and were best depicted with Gd FS T1WI sequences in 71% (5/7) and 86% (6/7) by the first and the second observer, respectively. CONCLUSION: In 3-T MRI, the comparison between transverse T1WI, FS T2WI, and Gd FS T1WI sequences shows that transverse T1WI allows excellent depiction of the A2 pulley, that FS T2WI suffers from a higher rate of motion and ghost artefacts, and transverse Gd FS T1WI is the best sequence for the depiction of abnormal A2 pulley.
Resumo:
BACKGROUND: : Thinness in children and adolescents is largely under studied, a contrast with abundant literature on under-nutrition in infants and on overweight in children and adolescents. The aim of this study is to compare the prevalence of thinness using two recently developed growth references, among children and adolescents living in the Seychelles, an economically rapidly developing country in the African region. METHOD: S: Weight and height were measured every year in all children of 4 grades (age range: 5 to 16 years) of all schools in the Seychelles as part of a routine school-based surveillance program. In this study we used data collected in 16,672 boys and 16,668 girls examined from 1998 to 2004. Thinness was estimated according to two growth references: i) an international survey (IS), defining three grades of thinness corresponding to a BMI of 18.5, 17.0 and 16.0 kg/m2 at age 18 and ii) the WHO reference, defined here as three categories of thinness (-1, -2 and -3 SD of BMI for age) with the second and third named "thinness" and "severe thinness", respectively. RESULTS: : The prevalence of thinness was 21.4%, 6.4% and 2.0% based on the three IS cut-offs and 27.7%, 6.7% and 1.2% based on the WHO cut-offs. The prevalence of thinness categories tended to decrease according to age for both sexes for the IS reference and among girls for the WHO reference. CONCLUSION: The prevalence of the first category of thinness was larger with the WHO cut-offs than with the IS cut-offs while the prevalence of thinness of "grade 2" and thinness of "grade 3" (IS cut-offs) was similar to the prevalence of "thinness" and "severe thinness" (WHO cut-offs), respectively.
Resumo:
This study compares the clientele of a Swiss anonymous test centre with the general population tested. Information was obtained through similar questionnaires submitted to two samples of HIV-tested people aged from 17 to 45 years: the first administered in the context of a general population telephone survey (n = 245) and the second completed during face-to-face interviews of the clientele of an anonymous test centre (n = 250). The test centre sample has higher proportions of younger and single people. Attenders for anonymous testing were more likely to have acquired a new regular partner during the year preceding the interview (48.0% versus 14.4%). These differences remain when controlling for age and gender. Decision to test comes mostly from the respondent's own initiative, but suggestion from a doctor is more frequent in the general population (23.8% versus 0.8%), whereas suggestion from partner or friends is more frequent in the anonymous centre (44.4% versus 3.0%). The anonymous test centre clientele is not different from the general population tested except for the relational situation and origin of decision for testing. The test centre has become a place where the general population finds a response to a situation-specific need for HIV testing.
Resumo:
Introduction Lesion detection in multiple sclerosis (MS) is an essential part of its clinical diagnosis. In addition, radiological characterisation of MS lesions is an important research field that aims at distinguishing different MS types, monitoring drug response and prognosis. To date, various MR protocols have been proposed to obtain optimal lesion contrast for early and comprehensive diagnosis of the MS disease. In this study, we compare the sensitivity of five different MR contrasts for lesion detection: (i) the DIR sequence (Double Inversion Recovery, [4]), (ii) the Dark-fluid SPACE acquisition schemes, a 3D variant of a 2D FLAIR sequence [1], (iii) the MP2RAGE [2], an MP-RAGE variant that provides homogeneous T1 contrast and quantitative T1-values, and the sequences currently used for clinical MS diagnosis (2D FLAIR, MP-RAGE). Furthermore, we investigate the T1 relaxation times of cortical and sub-cortical regions in the brain hemispheres and the cerebellum at 3T. Methods 10 early-stage female MS patients (age: 31.64.7y; disease duration: 3.81.9y; disability score, EDSS: 1.80.4) and 10 healthy controls (age and gender-matched: 31.25.8y) were included in the study after obtaining informed written consent according to the local ethic protocol. All experiments were performed at 3T (Magnetom Trio a Tim System, Siemens, Germany) using a 32-channel head coil [5]. The imaging protocol included the following sequences, (all except for axial FLAIR 2D with 1x1x1.2 mm3 voxel and 256x256x160 matrix): DIR (TI1/TI2/TR XX/3652/10000 ms, iPAT=2, TA 12:02 min), MP-RAGE (TI/TR 900/2300 ms, iPAT=3, TA 3:47 min); MP2RAGE (TI1/TI2/TR 700/2500/5000 ms, iPAT=3, TA 8:22 min, cf. [2]); 3D FLAIR SPACE (only for patient 4-6, TI/TR 1800/5000 ms, iPAT=2, TA=5;52 min, cf. [1]); Axial FLAIR (0.9x0.9x2.5 mm3, 256x256x44 matrix, TI/TR 2500/9000 ms, iPAT=2, TA 4:05 min). Lesions were identified by two experienced neurologist and radiologist, manually contoured and assigned to regional locations (s. table 1). Regional lesion masks (RLM) from each contrast were compared for number and volumes of lesions. In addition, RLM were merged in a single "master" mask, which represented the sum of the lesions of all contrasts. T1 values were derived for each location from this mask for patients 5-10 (3D FLAIR contrast was missing for patient 1-4). Results & Discussion The DIR sequence appears the most sensitive for total lesions count, followed by the MP2RAGE (table 1). The 3D FLAIR SPACE sequence turns out to be more sensitive than the 2D FLAIR, presumably due to reduced partial volume effects. Looking for sub-cortical hemispheric lesions, the DIR contrast appears to be equally sensitive to the MP2RAGE and SPACE, but most sensitive for cerebellar MS plaques. The DIR sequence is also the one that reveals cortical hemispheric lesions best. T1 relaxation times at 3T in the WM and GM of the hemispheres and the cerebellum, as obtained with the MP2RAGE sequence, are shown in table 2. Extending previous studies, we confirm overall longer T1-values in lesion tissue and higher standard deviations compared to the non-lesion tissue and control tissue in healthy controls. We hypothesize a biological (different degree of axonal loss and demyelination) rather than technical origin. Conclusion In this study, we applied 5 MR contrasts including two novel sequences to investigate the contrast of highest sensitivity for early MS diagnosis. In addition, we characterized for the first time the T1 relaxation time in cortical and sub-cortical regions of the hemispheres and the cerebellum. Results are in agreement with previous publications and meaningful biological interpretation of the data.
Resumo:
OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.
Resumo:
The response of Arabidopsis to stress caused by mechanical wounding was chosen as a model to compare the performances of high resolution quadrupole-time-of-flight (Q-TOF) and single stage Orbitrap (Exactive Plus) mass spectrometers in untargeted metabolomics. Both instruments were coupled to ultra-high pressure liquid chromatography (UHPLC) systems set under identical conditions. The experiment was divided in two steps: the first analyses involved sixteen unwounded plants, half of which were spiked with pure standards that are not present in Arabidopsis. The second analyses compared the metabolomes of mechanically wounded plants to unwounded plants. Data from both systems were extracted using the same feature detection software and submitted to unsupervised and supervised multivariate analysis methods. Both mass spectrometers were compared in terms of number and identity of detected features, capacity to discriminate between samples, repeatability and sensitivity. Although analytical variability was lower for the UHPLC-Q-TOF, generally the results for the two detectors were quite similar, both of them proving to be highly efficient at detecting even subtle differences between plant groups. Overall, sensitivity was found to be comparable, although the Exactive Plus Orbitrap provided slightly lower detection limits for specific compounds. Finally, to evaluate the potential of the two mass spectrometers for the identification of unknown markers, mass and spectral accuracies were calculated on selected identified compounds. While both instruments showed excellent mass accuracy (<2.5ppm for all measured compounds), better spectral accuracy was recorded on the Q-TOF. Taken together, our results demonstrate that comparable performances can be obtained at acquisition frequencies compatible with UHPLC on Q-TOF and Exactive Plus MS, which may thus be equivalently used for plant metabolomics.