144 resultados para Federation-Evènements-Performance-Recherche


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Errors in the inferred multiple sequence alignment may lead to false prediction of positive selection. Recently, methods for detecting unreliable alignment regions were developed and were shown to accurately identify incorrectly aligned regions. While removing unreliable alignment regions is expected to increase the accuracy of positive selection inference, such filtering may also significantly decrease the power of the test, as positively selected regions are fast evolving, and those same regions are often those that are difficult to align. Here, we used realistic simulations that mimic sequence evolution of HIV-1 genes to test the hypothesis that the performance of positive selection inference using codon models can be improved by removing unreliable alignment regions. Our study shows that the benefit of removing unreliable regions exceeds the loss of power due to the removal of some of the true positively selected sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the use of in situ implant formation that incorporates superparamagnetic iron oxide nanoparticles (SPIONs) as a form of minimally invasive treatment of cancer lesions by magnetically induced local hyperthermia. We developed injectable formulations that form gels entrapping magnetic particles into a tumor. We used SPIONs embedded in silica microparticles to favor syringeability and incorporated the highest proportion possible to allow large heating capacities. Hydrogel, single-solvent organogel and cosolvent (low-toxicity hydrophilic solvent) organogel formulations were injected into human cancer tumors xenografted in mice. The thermoreversible hydrogels (poloxamer, chitosan), which accommodated 20% w/v of the magnetic microparticles, proved to be inadequate. Alginate hydrogels, however, incorporated 10% w/v of the magnetic microparticles, and the external gelation led to strong implants localizing to the tumor periphery, whereas internal gelation failed in situ. The organogel formulations, which consisted of precipitating polymers dissolved in single organic solvents, displayed various microstructures. A 8% poly(ethylene-vinyl alcohol) in DMSO containing 40% w/v of magnetic microparticles formed the most suitable implants in terms of tumor casting and heat delivery. Importantly, it is of great clinical interest to develop cosolvent formulations with up to 20% w/v of magnetic microparticles that show reduced toxicity and centered tumor implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to investigate whether trainees' performance on a virtual reality angled laparoscope navigation task correlates with scores obtained on a validated conventional test of spatial ability. 56 participants of a surgery workshop performed an angled laparoscope navigation task on the Xitact LS 500 virtual reality Simulator. Performance parameters were correlated with the score of a validated paper-and-pencil test of spatial ability. Performance at the conventional spatial ability test significantly correlated with performance at the virtual reality task for overall task score (p < 0.001), task completion time (p < 0.001) and economy of movement (p = 0.035), not for endoscope travel speed (p = 0.947). In conclusion, trainees' performance in a standardized virtual reality camera navigation task correlates with their innate spatial ability. This VR session holds potential to serve as an assessment tool for trainees.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Falls efficacy, defined as confidence in performing activities without falling, is a measure of fear of falling associated with gait impairment, falls and functional decline in frail older people. This relationship has not been well studied in high-functioning older people. Objective: To evaluate the relationship between falls efficacy and gait performance in a cohort of high-functioning older people. Methods: Subjects (N = 864) were a subsample of communitydwelling older people aged 65 to 70 years, enrolled in the "Lc65+" cohort, who completed gait assessment at baseline. Data were collected on demographics, functional, cognitive, affective, and health status. Falls efficacy was assessed using the Falls Efficacy Scale- International (FES-I) that measures confidence in performing 16 activities of daily life (ADL) without falling (score from 16 to 64, higher score indicates lower confidence). Gait parameters were measured over a 20 m walk at preferred gait speed using Physilog, an ambulatory gait monitoring system. Results: Participants (mean age 68.0 ± 1.4 years, 55.0% women) had excellent physical (92.2% independent in basic ADL, mean gait speed 1.13 ± 0.16 m/sec) and cognitive (98.0% with MMSE 024) performance. Nevertheless, 22.1% reported depressive symptoms and 16.1% one or more fall in the previous year. Mean FES-I score was 18.8 ± 4.1. Falls efficacy was associated with gait speed (Spearman rho -0.23, P <.001) and gait variability (Spearman rho 0.10, P = .006), measured by the coefficient of variation of stride velocity. These associations remained in multivariate analysis for both gait speed (adj [beta] coeff: -0.008, 95%CI -0.005 to -0.010, P <.001) and gait variability (adj [beta] coeff 0.024, 95%CI 0.003 to 0.045, P = .023) independent of gender, falls, functional, affective, cognitive, and frailty (Fried's criteria) status. On average, compared to subjects with poor confidence in performing one ADL without falling, those with full confidence had a 0.02 m/sec (2%) faster gait speed and a 2% decrease in gait variability. Conclusion: Even in high-functioning older people, poor falls efficacy is associated with reduced gait speed and stability, independent of health, functional, and frailty status. The direction of this relationship needs to be investigated prospectively to determine causality and design interventions to improve gait performance, reduce fall risk, and prevent functional decline.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forensic examinations of ink have been performed since the beginning of the 20th century. Since the 1960s, the International Ink Library, maintained by the United States Secret Service, has supported those analyses. Until 2009, the search and identification of inks were essentially performed manually. This paper describes the results of a project designed to improve ink samples' analytical and search processes. The project focused on the development of improved standardization procedures to ensure the best possible reproducibility between analyses run on different HPTLC plates. The successful implementation of this new calibration method enabled the development of mathematical algorithms and of a software package to complement the existing ink library.