186 resultados para FINITE TOTAL CURVATURE
Resumo:
PURPOSE: All kinds of blood manipulations aim to increase the total hemoglobin mass (tHb-mass). To establish tHb-mass as an effective screening parameter for detecting blood doping, the knowledge of its normal variation over time is necessary. The aim of the present study, therefore, was to determine the intraindividual variance of tHb-mass in elite athletes during a training year emphasizing off, training, and race seasons at sea level. METHODS: tHb-mass and hemoglobin concentration ([Hb]) were determined in 24 endurance athletes five times during a year and were compared with a control group (n = 6). An analysis of covariance was used to test the effects of training phases, age, gender, competition level, body mass, and training volume. Three error models, based on 1) a total percentage error of measurement, 2) the combination of a typical percentage error (TE) of analytical origin with an absolute SD of biological origin, and 3) between-subject and within-subject variance components as obtained by an analysis of variance, were tested. RESULTS: In addition to the expected influence of performance status, the main results were that the effects of training volume (P = 0.20) and training phases (P = 0.81) on tHb-mass were not significant. We found that within-subject variations mainly have an analytical origin (TE approximately 1.4%) and a very small SD (7.5 g) of biological origin. CONCLUSION: tHb-mass shows very low individual oscillations during a training year (<6%), and these oscillations are below the expected changes in tHb-mass due to Herythropoetin (EPO) application or blood infusion (approximately 10%). The high stability of tHb-mass over a period of 1 year suggests that it should be included in an athlete's biological passport and analyzed by recently developed probabilistic inference techniques that define subject-based reference ranges.
Resumo:
BACKGROUND: The ideal local anesthetic regime for femoral nerve block that balances analgesia with mobility after total knee arthroplasty (TKA) remains undefined. QUESTIONS/PURPOSES: We compared two volumes and concentrations of a fixed dose of ropivacaine for continuous femoral nerve block after TKA to a single injection femoral nerve block with ropivacaine to determine (1) time to discharge readiness; (2) early pain scores and analgesic consumption; and (3) functional outcomes, including range of motion and WOMAC scores at the time of recovery. METHODS: Ninety-nine patients were allocated to one of three continuous femoral nerve block groups for this randomized, placebo-controlled, double-blind trial: a high concentration group (ropivacaine 0.2% infusion), a low concentration group (ropivacaine 0.1% infusion), or a placebo infusion group (saline 0.9% infusion). Infusions were discontinued on postoperative Day (POD) 2. The primary outcome was time to discharge readiness. Secondary outcomes included opioid consumption, pain, and functional outcomes. Ninety-three patients completed the study protocol; the study was halted early because of unanticipated changes to pain protocols at the host institution, by which time only 61% of the required number of patients had been enrolled. RESULTS: With the numbers available, the mean time to discharge readiness was not different between groups (high concentration group, 62 hours [95% confidence interval [CI], 51-72 hours]; low concentration group, 73 hours [95% CI, 63-83 hours]; placebo infusion group 65 hours [95% CI, 56-75 hours]; p = 0.27). Patients in the low concentration group consumed significantly less morphine during the period of infusion (POD 1, high concentration group, 56 mg [95% CI, 42-70 mg]; low concentration group, 35 mg [95% CI, 27-43 mg]; placebo infusion group, 48 mg [95% CI, 38-59 mg], p = 0.02; POD 2, high concentration group, 50 mg [95% CI, 41-60 mg]; low concentration group, 33 mg [95% CI, 24-42 mg]; placebo infusion group, 39 mg [95% CI, 30-48 mg], p = 0.04); however, there were no important differences in pain scores or opioid-related side effects with the numbers available. Likewise, there were no important differences in functional outcomes between groups. CONCLUSIONS: Based on this study, which was terminated prematurely before the desired sample size could be achieved, we were unable to demonstrate that varying the concentration and volume of a fixed-dose ropivacaine infusion for continuous femoral nerve block influences time to discharge readiness when compared with a conventional single-injection femoral nerve block after TKA. A low concentration of ropivacaine infusion can reduce postoperative opioid consumption but without any important differences in pain scores, side effects, or functional outcomes. These pilot data may be used to inform the statistical power of future randomized trials. LEVEL OF EVIDENCE: Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Resumo:
During episodes of trauma carnitine-free total parenteral nutrition (TPN) may result in a reduction of the total body carnitine pool, leading to a diminished rate of fat oxidation. Sixteen patients undergoing esophagectomy were divided randomly in two equal isonitrogenous groups (0.2 g/kg.day). Both received TPN (35 kcal/kg.day; equally provided as long-chain triglycerides and glucose) over 11 days without (group A) and with (group B) L-carnitine supplementation (12 mg/kg.day = 75 mumol/kg.day). Compared with healthy controls, the total body carnitine pool prior to the operation was significantly reduced in both groups, suggesting a state of semistarvation and muscle wasting. In group A the plasma levels of total carnitine and its subfractions (free carnitine, short- and long-chain acylcarnitine) remained stable during the study whereas in group B the total plasma carnitine concentration rose mainly due to an increase in free carnitine. In group A the cumulative urinary carnitine losses were 11.5 +/- 2.6 mmol (= 15.5 +/- 3.1% of the estimated total body carnitine pool). In group B 3.1 +/- 1.9 mmol (= 11.1 +/- 7.6%) of the infused carnitine was retained in the immediate postoperative phase until day 6, but this amount was completely lost at completion of the study period. No significant differences in the respiratory quotient or in the plasma levels of triglycerides, free fatty acids, and ketone bodies were observed, between or within the groups, before the operation and after 11 days of treatment. It is concluded that the usefulness of carnitine supplementation during postoperative TPN was not apparent in the present patient material.
Resumo:
The effect of acute intravenous dopamine (DA) administration at three sequential (but randomized) infusion rates was studied in eight young male volunteers. DA was infused at 2.5, 5, and 10 micrograms.kg-1.min-1. O2 consumption (VO2) and CO2 production (VCO2) were measured continuously by means of a computerized indirect calorimeter (blood system). In response to the 5- and 10-micrograms.kg-1.min-1 DA infusion rates, a significant increase (P less than 0.01) in VO2 corresponding to a 6% (range, 3-10) and 15% (range, 12-23) increase, respectively, of preinfusion values was observed. In contrast, at the low dose (2.5 micrograms.kg-1.min-1), DA induced no significant change in VO2. Cardiac output (Qc) increased significantly after the three DA administration rates [19% (range, 0-42), 34% (range, 17-71), and 25% (range, -3 to +47)] for the doses 2.5, 5, and 10 micrograms.-kg-1.min-1, respectively. The increase in O2 delivery (QO2) outweighed VO2 at all administration rates despite the relative drop in QO2 at the maximal DA administration rate. These results indicate that in humans DA improves net O2 supply to tissues proportionally more than it increases VO2 at all doses used in the present study.
Resumo:
Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.
Resumo:
Total body irradiation (TBI) has an established role as preparative regimen for bone-marrow transplantation in the treatment of hematological malignancies. Many randomized trials demonstrated that the clinical outcomes obtained from the association of TBI and cyclophosphamide are equivalent, or, sometimes, better than those based on chemotherapeutic agents. Despite the therapeutic progress of the last years, and the consequent improvement in the overall survival, this preparative regimen remains always associated with a relatively high rate of acute and late toxicity. In this article, we review the actual indications of TBI in clinical practice, and analyze the technological progress in this domain. We focus on the hypothesis that a selective irradiation of the hematopoietic or lymphoid organs is actually possible with intensity-modulated radiotherapy. Technical limits and preliminary results in terms of acute and late toxicities of intensity-modulated TBI are analyzed. With these new technologies, treatment-related toxicity is not anymore a major limiting factor in the preparative regimens for bone-marrow transplantation, allowing for a larger spectrum of TBI indications, a possible extension to patients older than 50 years, or a dose escalation. Preliminary results warrant, however, further evaluation in clinical trials to better assess the impact of this new approach on disease control and the long-term toxicity.
Resumo:
The aim of this experimental study is to evaluate the feasibility and the outcome of total endovascular stent implantation in the aortic arch. Indications for this operation-technique would be acute or chronic dissection of the aortic arch (non-A-non-B dissection) or type B dissection with retrograde extension. Four pigs were canulated via the distal abdominal aorta and a retrograde placement of a Djumbodis arch stent (4-9 cm) was controlled by using intravascular ultrasound and intracardiac ultrasound by the inferior cava vein and under radioscopic control. Cerebral perfusion, by using a flow meter placed on one prepared carotid artery, were controlled before, immediate post-procedural (<1 min), and in the early follow-up after aortic arch stent implantation. During the implantation process, especially during balloon inflation and deflation, mean carotid perfusion decreases slightly. A reactive increase of carotid perfusion after stent placements indicates transitory cerebral hypo-perfusion. Non-covered aortic arch stent implantation is technically feasible and could be a potential treatment option in otherwise inoperable arch dissections. The time required for balloon inflation and deflation causes an important risk of cerebral ischemia. The latter can be reduced by transaxillary perfusion.