97 resultados para Error Detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

MicroRNAs (miRNAs) are small, non-protein coding transcripts involved in many cellular and physiological mechanisms. Recently, a new class of miRNA called 'circulating miRNAs' was found in cell-free body fluids such as plasma and urine. Circulating miRNAs have been shown to be very stable, specific, and sensitive biomarkers. In this paper, we investigate whether circulating miRNAs can serve as biomarkers for erythropoiesis-stimulating agent abuse. To this end, we analyzed miRNA levels in plasma by miRNA microarrays and quantitative real-time polymerase chain reaction (PCR). Plasma samples are derived from a clinical study with healthy subjects injected with erythropoiesis-stimulating agent (C.E.R.A.). Based on microarray results, we observed a significant difference in the levels of miRNAs in plasma after C.E.R.A. injection. We demonstrated that a specific miRNA, miR-144, exhibit a high increase that lasts 27 days after C.E.R.A. stimulation. Considering the fact that miR-144 is an essential erythropoiesis agent in different organisms, these findings suggest the possibility of using miR-144 as a sensitive and informative biomarker to detect C.E.R.A. abuse. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The common acute lymphoblastic leukemia antigen (CALLA) has been detected in biological fluids using a radioimmunoassay based on the inhibition of binding of 125I-labeled monoclonal anti-CALLA antibody to glutaraldehyde-fixed NALM-1 cells. With this assay, we showed first that CALLA was released in culture fluids from NALM-1 and Daudi cell lines but was absent from culture fluids from CALLA negative cell lines. Then, we found that the sera of 34 out of 42 patients (81%) with untreated common acute lymphoblastic leukemia (c-ALL) contained higher CALLA levels than any of the 42 serum samples from healthy controls. The specificity of these results was further demonstrated by testing in parallel the sera from 48 patients with CALLA negative leukemias, including 26 acute myeloid leukemia (AML), 12 T-cell acute lymphoblastic leukemia (T-ALL), and 10 acute undifferentiated leukemia (AUL). All of these sera gave negative results, except for one patient with AUL, who had a significantly elevated circulating CALLA level, and one patient with AML, who had a borderline CALLA level, 3 SD over the mean of the normal sera. Preliminary results suggest that circulating CALLA is associated with membrane fragments or vesicles, since the total CALLA antigenic activity was recovered in the pellet of the serum samples centrifuged at 100,000 g. In addition, the CALLA-positive pellets contained an enzyme considered as a membrane marker, 5'-nucleotidase. Evaluation of the clinical importance of repeated serum CALLA determinations for the monitoring of c-ALL patients deserves further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Switzerland, individuals exposed to the risk of activity intake are required to perform regular monitoring. Monitoring consists in a screening measurement and is meant to be performed using commonly available laboratory instruments. More particularly, iodine intake is measured using a surface contamination monitor. The goal of the present paper is to report the calibration method developed for thyroid screening instruments. It consists of measuring the instrument response to a known activity located in the thyroid gland of a standard neck phantom. One issue of this procedure remains that the iodine radioisotopes have a short half-life. Therefore, the adequacy and limitations to simulate the short-lived radionuclides with so-called mock radionuclides of longer half-life were also evaluated. In light of the results, it has been decided to use only the appropriate iodine sources to perform the calibration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increase of the body's capacity to transport oxygen is a prime target for doping athletes in all endurance sports. For this pupose, blood transfusions or erythropoiesis stimulating agents (ESA), such as erythropoietin, NESP, and CERA are used. As direct detection of such manipulations is difficult, biomarkers that are connected to the haematopoietic system (haemoglobin concentration, reticulocytes) are monitored over time (Athlete Biological Passport (ABP)) and analyzed using mathematical models to identify patterns suspicious of doping. With this information, athletes can either be sanctioned directly based on their profile or targeted with conventional doping tests. Key issues for the appropriate use of the ABP are correct targeting and use of all available information (e.g. whereabouts, cross sectional population data) in a forensic manner. Future developments of the passport include the correction of all concentration-based variables for shifts in plasma volume, which might considerably increase sensitivity. New passport markers from the genomic, proteomic, and metabolomic level might add further information, but need to be validated before integration into the passport procedure. A first assessment of blood data of federations that have implemented the passport show encouraging signs of a decreased blood-doping prevalence in their athletes, which adds scientific credibility to this innovative concept in the fight against ESA- and blood doping. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection of latent fingermarks on thermal papers proves to be particularly challenging because the application of conventional detection techniques may turn the sample dark grey or black, thus preventing the observation of fingermarks. Various approaches aiming at avoiding or solving this problem have been suggested. However, in view of the many propositions available in the literature, it gets difficult to choose the most advantageous method and to decide which processing sequence should be followed when dealing with a thermal paper. In this study, 19 detection techniques adapted to the processing of thermal papers were assessed individually and then were compared to each other. An updated processing sequence, assessed through a pseudo-operational test, is suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Restriction site-associated DNA sequencing (RADseq) provides researchers with the ability to record genetic polymorphism across thousands of loci for nonmodel organisms, potentially revolutionizing the field of molecular ecology. However, as with other genotyping methods, RADseq is prone to a number of sources of error that may have consequential effects for population genetic inferences, and these have received only limited attention in terms of the estimation and reporting of genotyping error rates. Here we use individual sample replicates, under the expectation of identical genotypes, to quantify genotyping error in the absence of a reference genome. We then use sample replicates to (i) optimize de novo assembly parameters within the program Stacks, by minimizing error and maximizing the retrieval of informative loci; and (ii) quantify error rates for loci, alleles and single-nucleotide polymorphisms. As an empirical example, we use a double-digest RAD data set of a nonmodel plant species, Berberis alpina, collected from high-altitude mountains in Mexico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In vitro aggregating brain cell cultures containing all types of brain cells have been shown to be useful for neurotoxicological investigations. The cultures are used for the detection of nervous system-specific effects of compounds by measuring multiple endpoints, including changes in enzyme activities. Concentration-dependent neurotoxicity is determined at several time points. METHODS: A Markov model was set up to describe the dynamics of brain cell populations exposed to potentially neurotoxic compounds. Brain cells were assumed to be either in a healthy or stressed state, with only stressed cells being susceptible to cell death. Cells may have switched between these states or died with concentration-dependent transition rates. Since cell numbers were not directly measurable, intracellular lactate dehydrogenase (LDH) activity was used as a surrogate. Assuming that changes in cell numbers are proportional to changes in intracellular LDH activity, stochastic enzyme activity models were derived. Maximum likelihood and least squares regression techniques were applied for estimation of the transition rates. Likelihood ratio tests were performed to test hypotheses about the transition rates. Simulation studies were used to investigate the performance of the transition rate estimators and to analyze the error rates of the likelihood ratio tests. The stochastic time-concentration activity model was applied to intracellular LDH activity measurements after 7 and 14 days of continuous exposure to propofol. The model describes transitions from healthy to stressed cells and from stressed cells to death. RESULTS: The model predicted that propofol would affect stressed cells more than healthy cells. Increasing propofol concentration from 10 to 100 μM reduced the mean waiting time for transition to the stressed state by 50%, from 14 to 7 days, whereas the mean duration to cellular death reduced more dramatically from 2.7 days to 6.5 hours. CONCLUSION: The proposed stochastic modeling approach can be used to discriminate between different biological hypotheses regarding the effect of a compound on the transition rates. The effects of different compounds on the transition rate estimates can be quantitatively compared. Data can be extrapolated at late measurement time points to investigate whether costs and time-consuming long-term experiments could possibly be eliminated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Enterovirus (EV) is the most frequent cause of aseptic meningitis (AM). Lack of microbiological documentation results in unnecessary antimicrobial therapy and hospitalization. OBJECTIVES: To assess the impact of rapid EV detection in cerebrospinal fluid (CSF) by a fully-automated PCR (GeneXpert EV assay, GXEA) on the management of AM. STUDY DESIGN: Observational study in adult patients with AM. Three groups were analyzed according to EV documentation in CSF: group A=no PCR or negative PCR (n=17), group B=positive real-time PCR (n=20), and group C=positive GXEA (n=22). Clinical, laboratory and health-care costs data were compared. RESULTS: Clinical characteristics were similar in the 3 groups. Median turn-around time of EV PCR decreased from 60h (IQR (interquartile range) 44-87) in group B to 5h (IQR 4-11) in group C (p<0.0001). Median duration of antibiotics was 1 (IQR 0-6), 1 (0-1.9), and 0.5 days (single dose) in groups A, B, and C, respectively (p<0.001). Median length of hospitalization was 4 days (2.5-7.5), 2 (1-3.7), and 0.5 (0.3-0.7), respectively (p<0.001). Median hospitalization costs were $5458 (2676-6274) in group A, $2796 (2062-5726) in group B, and $921 (765-1230) in group C (p<0.0001). CONCLUSIONS: Rapid EV detection in CSF by a fully-automated PCR improves management of AM by significantly reducing antibiotic use, hospitalization length and costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to identify macrophage-rich atherosclerotic plaque noninvasively by imaging the tissue uptake of long-circulating superparamagnetic nanoparticles with a positive contrast off-resonance imaging sequence (inversion recovery with ON-resonant water suppression [IRON]). BACKGROUND: The sudden rupture of macrophage-rich atherosclerotic plaques can trigger the formation of an occlusive thrombus in coronary vessels, resulting in acute myocardial infarction. Therefore, a noninvasive technique that can identify macrophage-rich plaques and thereby assist with risk stratification of patients with atherosclerosis would be of great potential clinical utility. METHODS: Experiments were conducted on a clinical 3-T magnetic resonance imaging (MRI) scanner in 7 heritable hyperlipidemic and 4 control rabbits. Monocrystalline iron-oxide nanoparticles (MION)-47 were administrated intravenously (2 doses of 250 mumol Fe/kg), and animals underwent serial IRON-MRI before injection of the nanoparticles and serially after 1, 3, and 6 days. RESULTS: After administration of MION-47, a striking signal enhancement was found in areas of plaque only in hyperlipidemic rabbits. The magnitude of enhancement on magnetic resonance images had a high correlation with the number of macrophages determined by histology (p < 0.001) and allowed for the detection of macrophage-rich plaque with high accuracy (area under the curve: 0.92, SE: 0.04, 95% confidence interval: 0.84 to 0.96, p < 0.001). No significant signal enhancement was measured in remote areas without plaque by histology and in control rabbits without atherosclerosis. CONCLUSIONS: Using IRON-MRI in conjunction with superparamagnetic nanoparticles is a promising approach for the noninvasive evaluation of macrophage-rich, vulnerable plaques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse oximetry has been proposed as a noninvasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ultrastructure of the membrane attack complex (MAC) of complement had been described as representing a hollow cylinder of defined dimensions that is composed of the proteins C5b, C6, C7, C8, and C9. After the characteristic cylindrical structure was identified as polymerized C9 [poly(C9)], the question arose as to the ultrastructural identity and topology of the C9-polymerizing complex C5b-8. An electron microscopic analysis of isolated MAC revealed an asymmetry of individual complexes with respect to their length. Whereas the length of one boundary (+/- SEM) was always 16 +/- 1 nm, the length of the other varied between 16 and 32 nm. In contrast, poly(C9), formed spontaneously from isolated C9, had a uniform tubule length (+/- SEM) of 16 +/- 1 nm. On examination of MAC-phospholipid vesicle complexes, an elongated structure was detected that was closely associated with the poly(C9) tubule and that extended 16-18 nm beyond the torus of the tubule and 28-30 nm above the membrane surface. The width of this structure varied depending on its two-dimensional projection in the electron microscope. By using biotinyl C5b-6 in the formation of the MAC and avidin-coated colloidal gold particles for the ultrastructural analysis, this heretofore unrecognized subunit of the MAC could be identified as the tetramolecular C5b-8 complex. Identification also was achieved by using anti-C5 Fab-coated colloidal gold particles. A similar elongated structure of 25 nm length (above the surface of the membrane) was observed on single C5b-8-vesicle complexes. It is concluded that the C5b-8 complex, which catalyzes poly(C9) formation, constitutes a structure of discrete morphology that remains as such identifiable in the fully assembled MAC, in which it is closely associated with the poly(C9) tubule.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zero correlation between measurement error and model error has been assumed in existing panel data models dealing specifically with measurement error. We extend this literature and propose a simple model where one regressor is mismeasured, allowing the measurement error to correlate with model error. Zero correlation between measurement error and model error is a special case in our model where correlated measurement error equals zero. We ask two research questions. First, we wonder if the correlated measurement error can be identified in the context of panel data. Second, we wonder if classical instrumental variables in panel data need to be adjusted when correlation between measurement error and model error cannot be ignored. Under some regularity conditions the answer is yes to both questions. We then propose a two-step estimation corresponding to the two questions. The first step estimates correlated measurement error from a reverse regression; and the second step estimates usual coefficients of interest using adjusted instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Microbiological diagnostic procedures have changed significantly over the last decade. Initially the implementation of the polymerase chain reaction (PCR) resulted in improved detection tests for microbes that were difficult or even impossible to detect by conventional methods such as culture and serology, especially in community-acquired respiratory tract infections (CA-RTI). A further improvement was the development of real-time PCR, which allows end point detection and quantification, and many diagnostic laboratories have now implemented this powerful method. Objective: At present, new performant and convenient molecular tests have emerged targeting in parallel many viruses and bacteria responsible for lower and/or upper respiratory tract infections. The range of test formats and microbial agents detected is evolving very quickly and the added value of these new tests needs to be studied in terms of better use of antibiotics, better patient management, duration of hospitalization and overall costs. Conclusions: Molecular tools for a better microbial documentation of CA-RTI are now available. Controlled studies are now required to address the relevance issue of these new methods, such as, for example, the role of some newly detected respiratory viruses or of the microbial DNA load in a particular patient at a particular time. The future challenge for molecular diagnosis will be to become easy to handle, highly efficient and cost-effective, delivering rapid results with a direct impact on clinical management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the diagnostic value of the intravascular contrast agent gadocoletic acid (B-22956) in three-dimensional, free breathing coronary magnetic resonance angiography (MRA) for stenosis detection in patients with suspected or known coronary artery disease. METHODS: Eighteen patients underwent three-dimensional, free breathing coronary MRA of the left and right coronary system before and after intravenous application of a single dose of gadocoletic acid (B-22956) using three different dose regimens (group A 0.050 mmol/kg; group B 0.075 mmol/kg; group C 0.100 mmol/kg). Precontrast scanning followed a coronary MRA standard non-contrast T2 preparation/turbo-gradient echo sequence (T2Prep); for postcontrast scanning an inversion-recovery gradient echo sequence was used (real-time navigator correction for both scans). In pre- and postcontrast scans quantitative analysis of coronary MRA data was performed to determine the number of visible side branches, vessel length and vessel sharpness of each of the three coronary arteries (LAD, LCX, RCA). The number of assessable coronary artery segments was determined to calculate sensitivity and specificity for detection of stenosis > or = 50% on a segment-to-segment basis (16-segment-model) in pre- and postcontrast scans with x-ray coronary angiography as the standard of reference. RESULTS: Dose group B (0.075 mmol/kg) was preferable with regard to improvement of MR angiographic parameters: in postcontrast scans all MR angiographic parameters increased significantly except for the number of visible side branches of the left circumflex artery. In addition, assessability of coronary artery segments significantly improved postcontrast in this dose group (67 versus 88%, p < 0.01). Diagnostic performance (sensitivity, specificity, accuracy) was 83, 77 and 78% for precontrast and 86, 95 and 94% for postcontrast scans. CONCLUSIONS: The use of gadocoletic acid (B-22956) results in an improvement of MR angiographic parameters, asssessability of coronary segments and detection of coronary stenoses > or = 50%.