82 resultados para Classification, Degeneration, Lumbar intervertebral disc, Reliability, Validity
Resumo:
Mitochondrial (M) and lipid droplet (L) volume density (vd) are often used in exercise research. Vd is the volume of muscle occupied by M and L. The means of calculating these percents are accomplished by applying a grid to a 2D image taken with transmission electron microscopy; however, it is not known which grid best predicts these values. PURPOSE: To determine the grid with the least variability of Mvd and Lvd in human skeletal muscle. METHODS: Muscle biopsies were taken from vastus lateralis of 10 healthy adults, trained (N=6) and untrained (N=4). Samples of 5-10mg were fixed in 2.5% glutaraldehyde and embedded in EPON. Longitudinal sections of 60 nm were cut and 20 images were taken at random at 33,000x magnification. Vd was calculated as the number of times M or L touched two intersecting grid lines (called a point) divided by the total number of points using 3 different sizes of grids with squares of 1000x1000nm sides (corresponding to 1µm2), 500x500nm (0.25µm2) and 250x250nm (0.0625µm2). Statistics included coefficient of variation (CV), 1 way-BS ANOVA and spearman correlations. RESULTS: Mean age was 67 ± 4 yo, mean VO2peak 2.29 ± 0.70 L/min and mean BMI 25.1 ± 3.7 kg/m2. Mean Mvd was 6.39% ± 0.71 for the 1000nm squares, 6.01% ± 0.70 for the 500nm and 6.37% ± 0.80 for the 250nm. Lvd was 1.28% ± 0.03 for the 1000nm, 1.41% ± 0.02 for the 500nm and 1.38% ± 0.02 for the 250nm. The mean CV of the three grids was 6.65% ±1.15 for Mvd with no significant differences between grids (P>0.05). Mean CV for Lvd was 13.83% ± 3.51, with a significant difference between the 1000nm squares and the two other grids (P<0.05). The 500nm squares grid showed the least variability between subjects. Mvd showed a positive correlation with VO2peak (r = 0.89, p < 0.05) but not with weight, height, or age. No correlations were found with Lvd. CONCLUSION: Different size grids have different variability in assessing skeletal muscle Mvd and Lvd. The grid size of 500x500nm (240 points) was more reliable than 1000x1000nm (56 points). 250x250nm (1023 points) did not show better reliability compared with the 500x500nm, but was more time consuming. Thus, choosing a grid with square size of 500x500nm seems the best option. This is particularly relevant as most grids used in the literature are either 100 points or 400 points without clear information on their square size.
Resumo:
Introduction: In order to improve safety of pedicle screw placement several techniques have been developed. More recently robotically assisted pedicle insertion has been introduced aiming at increasing accuracy. The aim of this study was to compare this new technique with the two main pedicle insertion techniques in our unit namely fluoroscopically assisted vs EMG aided insertion. Material and methods: A total of 382 screws (78 thoracic,304 lumbar) were introduced in 64 patients (m/f = 1.37, equally distributed between insertion technique groups) by a single experienced spinal surgeon. From those, 64 (10 thoracic, 54 lumbar) were introduced in 11 patients using a miniature robotic device based on pre operative CT images under fluoroscopic control. 142 (4 thoracic, 138 lumbar) screws were introduced using lateral fluoroscopy in 27 patients while 176 (64 thoracic, 112 lumbar) screws in 26 patients were inserted using both fluoroscopy and EMG monitoring. There was no difference in the distribution of scoliotic spines between the 3 groups (n = 13). Screw position was assessed by an independent observer on CTs in axial, sagittal and coronal planes using the Rampersaud A to D classification. Data of lumbar and thoracic screws were processed separately as well as data obtained from axial, sagittal and coronal CT planes. Results: Intra- and interobserver reliability of the Rampersaud classification was moderate, (0.35 and 0.45 respectively) being the least good on axial plane. The total number of misplaced screws (C&D grades) was generally low (12 thoracic and 12 lumbar screws). Misplacement rates were same in straight and scoliotic spines. The only difference in misplacement rates was observed on axial and coronal images in the EMG assisted thoracic screw group with a higher proportion of C or D grades (p <0.05) in that group. Recorded compound muscle action potentials (CMAP) values of the inserted screws were 30.4 mA for the robot and 24.9mA for the freehand technique with a CI of 3.8 of the mean difference of 5.5 mA. Discussion: Robotic placement did improve the placement of thoracic screws but not that of lumbar screws possibly because our misplacement rates in general near that of published navigation series. Robotically assisted spine surgery might therefore enhance the safety of screw placement in particular in training settings were different users at various stages of their learning curve are involved in pedicle instrumentation.
Resumo:
Palmer previously proposed a classification system of triangular fibrocartilage complex (TFCC) injuries that proved to be useful in directing clinical management. However, dorsal peripheral tears (variants of class 1C) were not described and have rarely been reported in the literature since. We herewith present a rare case of bucket-handle tear of the TFCC. To our knowledge, this is the first case demonstrating partial separation of both the palmar and dorsal distal radioulnar ligaments (DRULs) from the articular disc. The particular wrist magnetic resonance (MR) arthrographic findings of this unusual complex peripheral TFCC tear (a variant of both class 1B and 1C) were nicely appreciated upon sagittal reformatted images.
Resumo:
The Pulmonary Embolism Severity Index (PESI) is a validated clinical prognostic model for patients with acute pulmonary embolism (PE). Our goal was to assess the PESI's inter-rater reliability in patients diagnosed with PE. We prospectively identified consecutive patients diagnosed with PE in the emergency department of a Swiss teaching hospital. For all patients, resident and attending physician raters independently collected the 11 PESI variables. The raters then calculated the PESI total point score and classified patients into one of five PESI risk classes (I-V) and as low (risk classes I/II) versus higher-risk (risk classes III-V). We examined the inter-rater reliability for each of the 11 PESI variables, the PESI total point score, assignment to each of the five PESI risk classes, and classification of patients as low versus higher-risk using kappa (κ) and intra-class correlation coefficients (ICC). Among 48 consecutive patients with an objective diagnosis of PE, reliability coefficients between resident and attending physician raters were > 0.60 for 10 of the 11 variables comprising the PESI. The inter-rater reliability for the PESI total point score (ICC: 0.89, 95% CI: 0.81-0.94), PESI risk class assignment (κ: 0.81, 95% CI: 0.66-0.94), and the classification of patients as low versus higher-risk (κ: 0.92, 95% CI: 0.72-0.98) was near perfect. Our results demonstrate the high reproducibility of the PESI, supporting the use of the PESI for risk stratification of patients with PE.
Resumo:
The application of support vector machine classification (SVM) to combined information from magnetic resonance imaging (MRI) and [F18]fluorodeoxyglucose positron emission tomography (FDG-PET) has been shown to improve detection and differentiation of Alzheimer's disease dementia (AD) and frontotemporal lobar degeneration. To validate this approach for the most frequent dementia syndrome AD, and to test its applicability to multicenter data, we randomly extracted FDG-PET and MRI data of 28 AD patients and 28 healthy control subjects from the database provided by the Alzheimer's Disease Neuroimaging Initiative (ADNI) and compared them to data of 21 patients with AD and 13 control subjects from our own Leipzig cohort. SVM classification using combined volume-of-interest information from FDG-PET and MRI based on comprehensive quantitative meta-analyses investigating dementia syndromes revealed a higher discrimination accuracy in comparison to single modality classification. For the ADNI dataset accuracy rates of up to 88% and for the Leipzig cohort of up to 100% were obtained. Classifiers trained on the ADNI data discriminated the Leipzig cohorts with an accuracy of 91%. In conclusion, our results suggest SVM classification based on quantitative meta-analyses of multicenter data as a valid method for individual AD diagnosis. Furthermore, combining imaging information from MRI and FDG-PET might substantially improve the accuracy of AD diagnosis.
Resumo:
The purpose of this study was to assess the validity of two common methods used to assess energy intake. A 3-day weighed dietary record and a dietary history were collected and compared with the total daily energy expenditure (TEE) assessed by the heart rate method in a group of 12 obese and 12 nonobese prepubertal children (mean age 9.3 +/- 1.1 years vs 9.3 +/- 0.4 years). The TEE value was higher in obese than in nonobese children (9.89 +/- 1.08 vs 8.13 +/- 1.39 MJ/day; p < 0.01). Energy intake assessed by the dietary record was significantly lower than TEE in the obese children (7.06 +/- 0.98 MJ/day; p < 0.001) but comparable to TEE in the nonobese children (8.03 +/- 0.99 MJ/day; p = not significant). Energy intake assessed by diet history was lower than TEE in the obese children (8.37 +/- 1.35 MJ/day, p < 0.05) but close to TEE in the nonobese children (8.64 +/- 1.54 MJ/day, p = not significant). These results suggest that obese children underreport food intake and that the dietary record and the diet history are not valid means of assessing energy intake in obese prepubertal children.
Resumo:
BACKGROUND: The AO comprehensive pediatric longbone fracture classification system describes the localization and morphology of fractures, and considers severity in 3 categories: (1) simple, (2) wedge, and (3) complex. We evaluated the reliability and accuracy of surgeons in using this rating system. MATERIAL AND METHODS: In a first validation phase, 5 experienced pediatric (orthopedic) surgeons reviewed radiographs of 267 prospectively collected pediatric fractures (agreement study A). In a second study (B), 70 surgeons of various levels of experience in 15 clinics classified 275 fractures via internet. Simple fractures comprised about 90%, 99% and 100% of diaphyseal (D), metaphyseal (M), and epiphyseal (E) fractures, respectively. RESULTS: Kappa coefficients for severity coding in D fractures were 0.82 and 0.51 in studies A and B, respectively. The median accuracy of surgeons in classifying simple fractures was above 97% in both studies but was lower, 85% (46-100), for wedge or complex D fractures. INTERPRETATION: While reliability and accuracy estimates were satisfactory as a whole, the ratings of some individual surgeons were inadequate. Our findings suggest that the classification of fracture severity in children should be done in only two categories that distinguish between simple and wedge/complex fractures.
Resumo:
INTRODUCTION: Numerous instruments have been developed to assess spirituality and measure its association with health outcomes. This study's aims were to identify instruments used in clinical research that measure spirituality; to propose a classification of these instruments; and to identify those instruments that could provide information on the need for spiritual intervention. METHODS: A systematic literature search in MEDLINE, CINHAL, PsycINFO, ATLA, and EMBASE databases, using the terms "spirituality" and "adult$," and limited to journal articles was performed to identify clinical studies that used a spiritual assessment instrument. For each instrument identified, measured constructs, intended goals, and data on psychometric properties were retrieved. A conceptual and a functional classification of instruments were developed. RESULTS: Thirty-five instruments were retrieved and classified into measures of general spirituality (N = 22), spiritual well-being (N = 5), spiritual coping (N = 4), and spiritual needs (N = 4) according to the conceptual classification. Instruments most frequently used in clinical research were the FACIT-Sp and the Spiritual Well-Being Scale. Data on psychometric properties were mostly limited to content validity and inter-item reliability. According to the functional classification, 16 instruments were identified that included at least one item measuring a current spiritual state, but only three of those appeared suitable to address the need for spiritual intervention. CONCLUSIONS: Instruments identified in this systematic review assess multiple dimensions of spirituality, and the proposed classifications should help clinical researchers interested in investigating the complex relationship between spirituality and health. Findings underscore the scarcity of instruments specifically designed to measure a patient's current spiritual state. Moreover, the relatively limited data available on psychometric properties of these instruments highlight the need for additional research to determine whether they are suitable in identifying the need for spiritual interventions.
Resumo:
RAPPORT DE SYNTHESE La dégénérescence maculaire liée à l'âge (DMLA) est une maladie très fréquente qui représente la cause principale de cécité légale chez les sujets de plus de 50 ans en Occident. Bien que l'étiologie exacte de cette affection ne soit pas complètement connue, des facteurs environnementaux et génétiques influencent sa survenue et son évolution. A ce sujet, de récentes recherches ont notamment montré une association marquée à une variante du gène CFH, Y402H. Nous ignorons toutefois si le polymorphisme Y402H est associé à un phénotype particulier de la maladie. Cette étude a pour but d'établir si cette variante du gène CFH est associée à certaines caractéristiques phénotypiques précoces. L'étude porte sur quatre cent vingt patients atteints de DMLA qui ont été phénotypés sur la base de photographie du fond d'oeil (International Classification and Grading system for age- related macular degeneration) et génotypés à partir d'ADN leucocytaire à la recherche de la variante Y402H du gène CFH. Ces données ont ensuite fait l'objet d'une analyse statistique de l'association génotype-phénotype (le génotype de 50 sujets-contrôle a été utilisé pour confirmer l'association du polymorphisme avec la DMLA). Les résultats obtenus, corrigés pour l'âge et le sexe, montrent un odds ratio (OR) de développer une DMLA de 2.95 en présence d'au moins un allèle à risque C et de 9.05 pour les homozygotes CC. Par contre, aucune influence n'est observée sur les stades de la maladie (précoce-tardif)? Une association significative entre le génotype CC et la présence de druses périphériques (p=0.028), ainsi que la localisation centrale des druses (p=0,049) a été mise en évidence. Aucune autre tendance n'a été dégagée concernant les critères restants (taille, surface totale recouverte, localisation nasale des druses) ou les changements pigmentaires. Cette étude a permis de confirmer l'association entre la variante Y4G2H et la DMLA dans la population suisse et de conclure que la variante Y402H du gène CFH présente une association géno-phénotypique pour certaines caractéristiques des druses. Il est probable que d'autres facteurs génétiques encore influencent le phénotype de la DMLA. De nouvelles recherches seront nécessaires pour préciser l'influence de ces autres facteurs génétiques ou environnementaux, en vue d'une meilleure compréhension de la pathogenèse de cette affection, et pour développer des mesures thérapeutiques et prophylactiques adaptées.
Resumo:
PURPOSE: Self-administered questionnaires continue to be the most widely used type of physical activity assessment in epidemiological studies. However, test-retest reliability and validity of physical activity questionnaires have to be determined. In this study, three short physical activity questionnaires already used in Switzerland and the International Physical Activity Questionnaire (IPAQ) were validated. METHODS: Test-retest reliability was assessed by repeated administration of all questionnaires within 3 wk in 178 volunteers (77 women, 46.1+/-14.8 yr; 101 men 46.8+/-13.2 yr). Validity of categorical and continuous data was studied in a subsample of 35 persons in relation to 7-d accelerometer readings, percent body fat, and cardiorespiratory fitness. RESULTS: Reliability was fair to good with a Spearman correlation coefficient range of 0.43-0.68 for measures of continuous data and moderate to fair with Kappa values between 0.32 and 0.46 for dichotomous measures active/inactive. Total physical activity reported in the IPAQ and the Office in Motion Questionnaire (OIMQ) correlated with accelerometry readings (r=0.39 and 0.44, respectively). In contrast, correlations of self-reported physical data with percent body fat and cardiorespiratory fitness were low (r=-0.26-0.29). Participants categorized as active by the Swiss HEPA Survey 1999 instrument (HEPA99) accumulated significantly more days of the recommended physical activities than their inactive counterparts (4.4 and 2.7 d.wk, respectively, P<0.05). However, compared with accelerometer data, vigorous physical activities were overreported in investigated questionnaires. CONCLUSION: Collecting valid data on physical activity remains a challenging issue for questionnaire surveys. The IPAQ and the three other questionnaires are characterized to inform decisions about their appropriate use.
Resumo:
Abstract Purpose: Age-related macular degeneration (AMD) has been associated with a number of polymorphisms in genes in the complement pathway. We examined the potential genotype-phenotype correlation of complement factor B (CFB) (R32Q) polymorphisms in Caucasian patients with AMD. Methods: Data from a Central European cohort of 349 patients with early AMD in at least one eye were analyzed for potential associations of the CFB (R32Q/rs641153) polymorphism with phenotypic features of early AMD. Early AMD was classified according to the International Classification and Grading System into predominant drusen size, largest drusen, drusen covered surface, central or ring-like location, peripheral drusen, and pigmentary changes. The potential association with single nucleotide polymorphisms on CFB (R32Q/rs641153) was evaluated for all patients, corrected for age, sex, and the polymorphisms of CFH (Y402H) and ARMS2 (A69S). Results: CFB (R32Q) polymorphisms showed a significant association with smaller drusen size (largest drusen ≤250 µm, p = 0.021, predominant drusen ≤125 µm, p = 0.016), with smaller surface covered by drusen (≤10%; p = 0.02), and with more frequent occurrence of peripheral drusen (p = 0.007). No association was found for pigmentary changes. Conclusions: The CFB (R32Q) polymorphism was associated with AMD characterized by small drusen only, and appeared to be protective of large drusen (OR 0.48/0.45) and of larger drusen covered area (OR 0.34). Furthermore, peripheral drusen were more frequently found (OR 2.27). This result supports the role of complement components and their polymorphisms in drusen formation and may enable a better understanding of AMD pathogenesis.
Resumo:
OBJECTIVE: Evaluation of a French translation of the Addiction Severity Index (ASI) in 100 (78 male) alcoholic patients. METHOD: Validity of the instrument was assessed by measuring test-retest and interrater reliability, internal consistency and convergence and discrimination between items and scales. Concurrent validity was assessed by comparing the scores from the ASI with those obtained from three other clinimetric instruments. RESULTS: Test-retest reliability of ASI scores (after a 10-day interval) was good (r = 0.63 to r = 0.95). Interrater reliability was evaluated using six video recordings of patient interviews. Severity ratings assigned by six rates were significantly different (p < .05), but 72% of the ratings assigned by those who viewed the videos were within two points of the interviewer's severity ratings. Cronbach alpha coefficient of internal consistency varied from 0.58 to 0.81 across scales. The average item-to-scale convergent validity (r value) was 0.49 (range 0.0 to 0.84) for composite scores and 0.35 (range 0.00 to 0.68) for severity ratings, whereas discriminant validity was 0.11 on average (range-0.19 to 0.46) for composite scores and 0.12 (range-0.20 to 0.52) for severity ratings. Finally, concurrent validity with the following instruments was assessed: Severity of Alcoholism Dependence Questionnaire (40% shared variance with ASI alcohol scale), Michigan Alcoholism Screening Test (2% shared variance with ASI alcohol scale) and Hamilton Depression Rating Scale (31% shared variance with ASI psychiatric scale). CONCLUSIONS: The Addiction Severity Index covers a large scope of problems encountered among alcoholics and quantifies need for treatment. This French version presents acceptable criteria of reliability and validity.
Resumo:
OBJECTIVE: To demonstrate the validity and reliability of volumetric quantitative computed tomography (vQCT) with multi-slice computed tomography (MSCT) and dual energy X-ray absorptiometry (DXA) for hip bone mineral density (BMD) measurements, and to compare the differences between the two techniques in discriminating postmenopausal women with osteoporosis-related vertebral fractures from those without. METHODS: Ninety subjects were enrolled and divided into three groups based on the BMD values of the lumbar spine and/or the femoral neck by DXA. Groups 1 and 2 consisted of postmenopausal women with BMD changes <-2SD, with and without radiographically confirmed vertebral fracture (n=11 and 33, respectively). Group 3 comprised normal controls with BMD changes > or =-1SD (n=46). Post-MSCT (GE, LightSpeed16) scan reconstructed images of the abdominal-pelvic region, 1.25 mm thick per slice, were processed by OsteoCAD software to calculate the following parameters: volumetric BMD values of trabecular bone (TRAB), cortical bone (CORT), and integral bone (INTGL) of the left femoral neck, femoral neck axis length (NAL), and minimum cross-section area (mCSA). DXA BMD measurements of the lumbar spine (AP-SPINE) and the left femoral neck (NECK) also were performed for each subject. RESULTS: The values of all seven parameters were significantly lower in subjects of Groups 1 and 2 than in normal postmenopausal women (P<0.05, respectively). Comparing Groups 1 and 2, 3D-TRAB and 3D-INTGL were significantly lower in postmenopausal women with vertebral fracture(s) [(109.8+/-9.61) and (243.3+/-33.0) mg/cm3, respectively] than in those without [(148.9+/-7.47) and (285.4+/-17.8) mg/cm(3), respectively] (P<0.05, respectively), but no significant differences were evident in AP-SPINE or NECK BMD. CONCLUSION: the femoral neck-derived volumetric BMD parameters using vQCT appeared better than the DXA-derived ones in discriminating osteoporotic postmenopausal women with vertebral fractures from those without. vQCT might be useful to evaluate the effect of osteoporotic vertebral fracture status on changes in bone mass in the femoral neck.
Resumo:
The first AO comprehensive pediatric long-bone fracture classification system has been proposed following a structured path of development and validation with experienced pediatric surgeons. A Web-based multicenter agreement study involving 70 surgeons in 15 clinics and 5 countries was conducted to assess the reliability and accuracy of this classification when used by a wide range of surgeons with various levels of experience. Training was provided at each clinic before the session. Using the Internet, participants could log in at any time and classify 275 supracondylar, radius, and tibia fractures at their own pace. The fracture diagnosis was made following the hierarchy of the classification system using both clinical terminology and codes. kappa coefficients for the single-surgeon diagnosis of epiphyseal, metaphyseal, or diaphyseal fracture type were 0.66, 0.80, and 0.91, respectively. Median accuracy estimates for each bone and type were all greater than 80%. Depending on their experience and specialization, surgeons greatly varied in their ability to classify fractures. Pediatric training and at least 2 years of experience were associated with significant improvement in reliability and accuracy. Kappa coefficients for diagnosis of specific child patterns were 0.51, 0.63, and 0.48 for epiphyseal, metaphyseal, and diaphyseal fractures, respectively. Identified reasons for coding discrepancies were related to different understandings of terminology and definitions, as well as poor quality radiographic images. Results supported some minor adjustments in the coding of fracture type and child patterns. This classification system received wide acceptance and support among the surgeons involved. As long as appropriate training could be performed, the system classification was reliable, especially among surgeons with a minimum of 2 years of clinical experience. We encourage broad-based consultation between surgeons' international societies and the use of this classification system in the context of clinical practice as well as prospectively for clinical studies.